14. Install the four tightening tools with four tightening clamps that hold the EGR cooler to the
cooler support bracket. Apply 10 N·m (8 lb·ft) clamping force to clamps. See Figure 7-33.
1. EGR Cooler
3. Clamps (4 Qty.)
2. Tightening Tool for Clamps
4. Clamp Bolts
Figure 7-33
Installing Tightening Clamps on the Cooler