Download Goodman GPC/GPH 13 M R

Transcript
WIRING DIAGRAMS
PACKAGE SYSTEM WIRING DIAGRAM - 1 STAGE ELECTRIC HEAT
TYPICAL HP
ROOM THERMOSTAT
SEE NOTE 1
#18 GAUGE 7 WIRE
REQUIRED FOR
HEAT PUMPS
Y
O
C
W1
G
R
PACKAGE UNIT
LOW VOLTAGE
JUNCTION BOX
E
R
R
RED
Y
Y
YELLOW
G
G
GREEN
O
O
ORANGE
BR
W
WHITE
BL
BLUE
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
R
BL
BL
2
1
OUTDOOR THERMOSTAT
CLOSE ON TEMPERATURE FALL
PACKAGE SYSTEM WIRING DIAGRAM - 2 STAGE ELECTRIC HEAT
ABOVE 10 KW
TYPICAL HP
ROOM THERMOSTAT
SEE NOTE 1
#18 GAUGE 8 WIRE
FOR HEAT PUMPS
W2
Y
O
C
W1
G
R
PACKAGE UNIT
LOW VOLTAGE
JUNCTION BOX
E
RED
R
R
Y
Y
YELLOW
G
G
GREEN
O
O
ORANGE
BR
W
WHITE
R
BR
BROWN
BL
BL
BLUE
SEE NOTE 2
W
2
1
OUTDOOR THERMOSTAT
CLOSE ON TEMPERATURE FALL
NOTES:
1) "O" and "E" used on heat pumps only.
2) Connect wire from terminal #1 on outdoor thermostat to the white
wire on package units if single stage indoor thermostat is used.
Color Codes
R - Red
Y - Yellow
BL - Blue
BR - Brown
O - Orange
W - White
G - Green
OT18-60A OUTDOOR THERMOSTAT
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
49