Download Goodman Mfg RT6332013r1 User's Manual

Transcript
TECHNICAL MANU
AL
MANUAL
GPH 13 M Series Multi Position
Package Heat Pump Units
with R410A
• Refer to Service Manual RS6300008 for installation, operation, and troubleshooting information.
• All safety information must be followed as provided in the Service Manual.
• Refer to the appropriate Parts Catalog for part number information.
• Models listed on page 3.
This manual is to be used by qualified, professionally trained HVAC technicians only.
Goodman does not assume any responsibility for property damage or personal injury due to
improper service procedures or services performed by an unqualified person.
Copyright © 2010 Goodman Manufacturing Company, L.P.
RT6332013r1
November 2010
PRODUCT IDENTIFICATION
The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please
use these numbers when requesting service or parts information.
G
P
BRAND:
G: Goodman®
Brand
A: Amana®
Brand
H
13
36
A
A
REFRIGERANT:
4: R-410A
PRODUCT
SERIES:
13: Up to 13 SEER
MAJOR REVISION:
A: Initial Release
CONFIGURATION:
M: Mult-position
VOLTAGE:
1: 208-230v/1ph/60Hz
3. 208-230v/3ph/60Hz
4. 460V/3ph/60Hz
HIGH VOLTAGE!
Disconnect ALL power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal
injury or death.
Goodman will not be responsible
for any injury or property damage
arising from improper service or service procedures. If
you install or perform service on this unit, you assume
responsibility for any personal injury or property damage
which may result. Many jurisdictions require a license to
install or service heating and air conditioning equipment.
2
1
PRODUCT
FAMILY:
H: Heat Pump
NOMINAL
CAPACITY:
24: 24,000 BTUH
30: 30,000 BTUH
36: 36,000 BTUH
42: 42,000 BTUH
48: 48,000 BTUH
60: 60,000 BTUH
WARNING
4
MINOR REVISION:
A: Initial Release
PRODUCT
TYPE:
Package Unit
WARNING
M
Installation and repair of this unit
should be performed ONLY by individuals meeting (at a minimum)
the requirements of an "entry level technician" as specified by the Air-Conditioning, Heating, and Refrigeration
Institute (AHRI). Attempting to install or repair this unit
without such background may result in product damage,
personal injury or death.
WARNING
PRODUCT IDENTIFICATION
The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please
use these numbers when requesting service or parts information.
GPH1324M41AB
GPH1330M41AB
GPH1336M41AB
GPH1342M41AB
GPH1348M41AB
GPH1360M41AB
WARNING
The United States Environmental Protection Agency (“EPA”) has issued various regulations regarding the introduction and disposal of refrigerants introduced into this unit. Failure to follow
these regulations may harm the environment and can lead to the imposition of substantial fines.
These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office.
Do not connect or use any device
that is not design certified by
Goodman for use with this unit.
Serious property damage, personal injury, reduced unit
performance and/or hazardous conditions may result
from the use of such non-approved devices.
WARNING
To prevent the risk of property
damage, personal injury, or death,
do not store combustible materials or use gasoline or
other flammable liquids or vapors in the vicinity of this
appliance.
WARNING
3
PRODUCT DESIGN
GPH13 (M Series) Package Units are designed for outdoor
installations only in either residential or light commercial applications and are available in 2, 2.5, 3, 3.5, 4 & 5 ton sizes.
They are designed for 208/230 volt single phase applications.
The connecting ductwork (Supply and Return) can be connected for either horizontal or vertical airflow. In the vertical
application, a matching Roof Curb is recommended and a
horizontal duct cover kit is required.
A return air filter must be installed behind the return air grille(s)
or provision must be made for a filter in an accessible location within the return air duct. The minimum filter area should
not be less than those sizes listed in the Specification Section. Under no circumstances should the unit be operated
without return air filters.
A 3/4" pipe is provided for removal of condensate water from
the indoor coil. A trap must be provided to have proper condensate drainage. (Do not reduce the drain line size).
Refrigerant flow control is achieved by use of restrictor orifices.
All heat pump models also have a suction line accumulator
installed between the reversing valve and the compressor.
The object of the accumulator is to:
1. Provide a liquid refrigerant storage vessel during prolonged
system off cycles.
2. Store excess liquid refrigerant not needed by the system
while running.
3. Return oil and saturated vapor to the compressor at a
controlled rate.
4. Retain stored excess refrigerant during a sudden system
pressure fluctuation such as seen in defrost cycles.
Refrigerant flow control is achieved by use of restrictor
orifices. These models use the FasTest Access Fitting
System, with a saddle that is either soldered to the suction
and liquid lines or is fastened with a locking nut to the access
fitting box (core) and then screwed into the saddle. Do not
remove the core from the saddle until the refrigerant
charge has been removed. Failure to do so could result
in property damage or personal injury.
The single phase units use permanent split capacitor (PSC)
design compressors. Starting components are not required
for these units. A low microfarad run capacitor assists the
compressor to start and remains in the circuit during operation.
The outdoor fan motors are single phase capacitor type motors. Some models use PSC type indoor blower motors while
others use EEM type blower motors. EEM motors are energized by a 24V signal from the thermostat and are constant
torque motors with very low power consumption.
The EEM features an integral control module.
4
Air for condensing (cooling cycle) or evaporation (heating
cycle) is drawn through the outdoor coil by a propeller fan,
and is discharged vertically out the top of the unit. The outdoor coil is designed for .0 static. No additional restriction
(ductwork) shall be applied.
Conditioned air is drawn through the filter(s), field installed,
across the coil and back into the conditioned space by the
indoor blower.
Package Heat Pump indoor sections are designed to accept
optional components such as auxiliary electric heaters and
circuit breakers. Provisions for these components have been
made at time of manufacture.
GPH13 series package units use the Compliant Scroll compressor; there are a number of design characteristics which
are different from the traditional reciprocating compressor.
- Due to their design Scroll compressors are inherently more
tolerant of liquid refrigerant. NOTE: Even though the compressor section of a Scroll compressor is more tolerant of
liquid refrigerant, continued flood back or flooded start conditions may wash oil from the bearing surfaces causing premature bearing failure.
- These Scroll compressors use "POE" or polyolester oil which
is NOT compatible with mineral oil based lubricants like 3GS.
"POE" oil must be used if additional oil is required.
- Compliant scroll compressors perform “quiet” shutdowns
that allow the compressor to restart immediately without the
need for a time delay. This compressor will restart even if the
system has not equalized.
- Operating pressures and amp draws may differ from standard reciprocating compressors. This information may be
found in the “Cooling Performance Data” section.
Location and Clearances
NOTE: To ensure proper condensate drainage, unit must be
installed in a level position.
PRODUCT DESIGN
In installations where the unit is installed above ground level
and not serviceable from the ground (Example: roof top installations) the installer must provide service platform for service person with rails or guards in accordance with local codes
or ordinances, or, in their absence, with the latest edition of
the Uniform Mechanical Code Section 305.
NOTE: Unit can also use roof curb (and platform for leveling,
where necessary) to utilize bottom discharge.
WARNING
TO PREVENT POSSIBLE PROPERTY DAMAGE, THE
UNIT SHOULD REMAIN IN AN UPRIGHT POSITION
DURING ALL RIGGING AND MOVING OPERATIONS.
TO FACILITATE LIFTING AND MOVING IF A CRANE IS
USED, PLACE THE UNIT IN AN ADEQUATE CABLE
SLING.
Outside Slab Installation -Multi-positional (M)
NOTE: Roof overhang should be no more than 36" and provisions made to deflect the warm discharge air out from the
overhang.
Minimum clearances are required to avoid air recirculation
and keep the unit operating at peak efficiency.
IMPORTANT: If using bottom discharge with roof curb,
ductwork should be attached to the curb prior to installing
the unit.
NOTE: Single phase models require installation of horizontal
duct kit #20464501PDGK (medium chassis) and
#20464502PDGK (large chassis) when using bottom discharge.
Refer to Roof curb Installation Instructions for proper curb
installation. Curbing must be installed in compliance with the
National Roofing Contractors Association Manual.
Roof Curb
Rooftop Installation - -Multi-positional (M)
NOTE: To ensure proper condensate drainage, unit must be
installed in a level position.
5
PRODUCT DESIGN
GPH13[24-60]M41*
HKR ELECTRICAL DATA
Circuit #1
Circuit #2
Minimum Circuit
Ampacity
at 208 / 240V
Maximum
Overcurrent
Protection (amps)
at 208 / 240V
Minimum Circuit
Ampacity
at 208 / 240V
Maximum
Overcurrent
Protection (amps)
at 208 / 240V
Actual
kW & BTU
at 240V
GPH1324M41*
HKR05A,CA
HKR08A,CA
HKR10A,CA
24 / 27
33 / 28
45 / 51
30 / 30
40 / 40
60 / 60
----------
----------
4.75 / 16,200
7.00 / 23,800
9.50 / 32,400
GPH1330M41*
HKR05A,CA
HKR08A,CA
HKR10A,CA
HKR15A,CA
24 / 27
34 / 39
45 / 52
45 / 52
30 / 30
40 / 40
60 / 60
60 / 60
---22 / 25
---30 / 30
4.75 / 16,200
7.0 / 23,800
9.5 / 32,400
14.25 / 48,600
GPH1336M41*
HKR05A,CA
HKR08A,CA
HKR10A,CA
HKR15A,CA
24 / 27
34 / 39
45 / 52
45 / 52
30 / 30
40 / 40
60 / 60
60 / 60
---------22 / 25
---------30 / 30
4.75 / 16,200
7.00 / 23,800
9.50 / 32,400
14.25 / 48,600
GPH1342M41*
HKR05A,CA
HKR08A,CA
HKR10A,CA
HKR15A,CA
24 / 27
34 / 39
45 / 52
45 / 52
30 / 30
40 / 40
60 / 60
60 / 60
---22 / 25
---30 / 30
4.75 / 16,200
7.0 / 23,800
9.5 / 32,400
14.25 / 48,600
25 / 28
30 / 30
----
----
4.75 / 16,200
34 / 40
46 / 53
46 / 52
46 / 52
40 / 40
60 / 60
60 / 60
60 / 60
------22 / 25
43 / 49
------30 / 30
60 / 60
7.00 / 23,800
9.50 / 32,400
14.25 / 48,600
19.50 / 66,500
26 / 30
36 / 40
48 / 54
48 / 54
48 / 54
30 / 30
40 / 40
60 / 60
60 / 60
60 / 60
---------22 / 25
43 / 49
---------30 / 30
60 / 60
4.75 / 16,200
7.00 / 23,800
9.50 / 32,400
14.25 / 48,600
19.50 / 66,500
GPH1348M41*
HKR05A,CA
HKR08A,CA
HKR10A,CA
HKR15A,CA
HKR20A,CA
GPH1360M41*
HKR05A,CA
HKR08A,CA
HKR10A,CA
HKR15A,CA
HKR20A,CA
IMPORTANT NOTE: A separate power supply is required for the HKR heater kit.
Heating kW Correction Factor
Supply Votage
240
230
220
210
208
Correction Factor
1.0
0.93
0.85
0.78
0.76
Multiply rated kW by correction factor to get actual kW
WARNING
6
All wires and overcurrent protection devices are sized for use with electric heaters only and without
refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See
PACKAGE UNIT SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent protection during refrigeration cycle.
PRODUCT DIMENSIONS
GPH13[24-60]M41*
47
51
POWER
WIRE
ENTRANCE
4 1/8
2 1/8
16
1 3/8
A?
5½
16
6½
B
8
2 34
RETURN
B?
SUCTION/LIQUID
PRESSURE PORT
SUPPLY
3
CONDENSATE
DRAIN
CONNECTION
3/4” NPT FEMALE
18 7/8
CONTROL
WIRE
ENTRANCE
BLOWER
ACCESS PANEL
MEDIUM CHASSIS
GPH1324M41*
GPH1330M41*
GPH1336M41*
GPH1342M41*
LARGE CHASSIS
GPH1348M41*
GPH1360M41*
7
PACKAGE HEAT PUMP SPECIFICATIONS GPH13[24-36]M41AB
GPH1324M41*
GPH1330M41*
GPH1336M41*
COOLING
COOLING CAPACITY, BTUH
24,000
29,000
34600
CAPACITY
SEER / EER
13/11
13/10.8
13/10.9
HEATING
BTU/h (47°)
23000
28800
34200
RATING
BTU/h (17°)
12600
17000
19000
HSPF
7.7
7.7
7.7
208/230-60-1
208/230-60-1
208/230-60-1
15.8
19.0
21.3
19.0
23.0
25.4
30
35
40
SCROLL
SCROLL
SCROLL
RATED LOAD AMPS
12.8
16.0
16.7
LOCKED ROTOR AMPS
58.3
77
79
CONDENSER
HORSEPOWER
1/4
1/4
1/4
FAN MOTOR
RPM
830
830
830
FULL LOAD AMPS
1.5
1.5
1.5
3
3
3
22/3
22/3
22/4
17.02
17.02
16.83
UNIT
VOLTAGE (NAMEPLATE)
ELECTRICAL
AMPS
SPECIFICATION
MIN CIRCUIT AMPACITY
MAX OVERCURRENT PROTECTION
COMPRESSOR
(1 )
TYPE
LOCKED ROTOR AMPS
CONDENSER FAN
BLADE DIAMETER (INCHES)
NUMBER OF BLADES
CONDENSER
FACE AREA (SQ. FT.)
COIL
NUMBER OF ROWS
1
1
1
FINS PER INCH
24
24
22
1/4 - 3
1/3 - 3
1/3 - 3
EVAPORATOR
HORSEPOWER - NUMBER OF SPEEDS
BLOWER
FULL LOAD AMPS
1.5
1.5
3.06
MOTOR
LOCKED ROTOR AMPS
2.13
3.2
4.1
MOTOR SPEED TAP - COOLING X-13
High
High
High
RPM
952
869
910
10 x 9
10 x 9
10 x 9
1150
EVAPORATOR
DIAMETER X WIDTH (INCHES)
BLOWER
RATED SCFM COOLING
825
1050
MAX EXTERNAL STATIC PRESS ("w.c.)
0.5
0.5
0.5
EVAPORATOR
FACE AREA (SQ. FT.)
4.52
4.52
4.52
COIL
NUMBER OF ROWS
4
4
4
FINS PER INCH
16
16
14
25 x 25 x 1
25 x 25 x 1
25 x 25 x 1
3/4"
3/4"
3/4"
0.057/0.045
0.070/0.055
0.071/0.057
REFRIGERANT CHARGE R410A (OZS.)
110
115
135
POWER SUPPLY
CONDUIT KNOCKOUT SIZE (INCHES)
3/4, 1, 1-1/4
3/4, 1, 1-1/4
3/4, 1, 1-1/4
LOW VOLTAGE
CONDUIT KNOCKOUT SIZE (INCHES)
1/2
1/2
1/2
22 / 50
22 / 50
22 / 50
GENERAL
FILTER SIZE *
INFORMATION
DRAIN SIZE (INCHES)
EXPANSION DEVICE (ID/OD)
LO PRESSURE SWITCH
OPENS / CLOSES PSIG
HI PRESSURE SWITCH - OPENS PSIG
660 / 420
660 / 420
660 / 420
SHIPPING WEIGHT (LBS.)
OPENS / CLOSES PSIG
405
410
435
OPERATING WEIGHT (LBS.)
395
400
425
(1)
*
Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.
Calculated external filter size based on air velocity of 300 ft/min.
Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information.
IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers
in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters.
8
PACKAGE HEAT PUMP SPECIFICATIONS GPH13[42-60]M41AB
GPH1342M41*
GPH1348M41*
GPH1360M41*
COOLING
COOLING CAPACITY, BTUH
40000
46500
56000
CAPACITY
SEER / EER
13/11
13/11
13/10.9
HEATING
BTU/h (47°)
40000
45500
55500
RATING
BTU/h (17°)
21000
26000
31200
HSPF
7.7
8.0
8.0
208/230-60-1
208/230-60-1
208/230-60-1
AMPS
22.4
29.0
35.4
MIN CIRCUIT AMPACITY
26.8
34.5
42.0
UNIT
VOLTAGE (NAMEPLATE)
ELECTRICAL
SPECIFICATION
(1)
40
50
60
SCROLL
SCROLL
SCROLL
RATED LOAD AMPS
17.9
21.8
26.4
LOCKED ROTOR AMPS
112
117
134
CONDENSER
HORSEPOWER
1/4
1/4
1/4
FAN MOTOR
RPM
MAX OVERCURRENT PROTECTION
COMPRESSOR
TYPE
1075
1075
1075
FULL LOAD AMPS
1.4
1.4
1.4
LOCKED ROTOR AMPS
2.9
2.9
2.9
CONDENSER FAN
BLADE DIAMETER (INCHES)
NUMBER OF BLADES
22/3
22/3
22/3
CONDENSER
FACE AREA (SQ. FT.)
16.83
19.24
21.04
COIL
NUMBER OF ROWS
2
2
2
FINS PER INCH
16
16
16
1/3 - 3
3/4 - 5
1- 5
7.6
EVAPORATOR
HORSEPOWER - NUMBER OF SPEEDS
BLOWER
FULL LOAD AMPS
3.06
5.8
MOTOR
LOCKED ROTOR AMPS
4.1
---
---
High
T2/T3
T2/T3
MOTOR SPEED TAP - COOLING X-13
910
1050
1050
EVAPORATOR
RPM
DIAMETER X WIDTH (INCHES)
10 x 9
10 x 9
10 x 9
BLOWER
RATED SCFM COOLING
1800
1300
1720
MAX EXTERNAL STATIC PRESS ("w.c.)
0.5
0.5
0.5
EVAPORATOR
FACE AREA (SQ. FT.)
4.52
6.17
6.17
COIL
NUMBER OF ROWS
4
4
4
FINS PER INCH
14
14
14
25 x 25 x 1
(2) 20 x 20 x 1
(2) 20 x 20 x 1
GENERAL
FILTER SIZE *
INFORMATION
DRAIN SIZE (INCHES)
3/4"
3/4"
3/4"
0.072/0.063
0.080/0.065
0.084/0.076
REFRIGERANT CHARGE R410A (OZS.)
180
190
220
POWER SUPPLY
CONDUIT KNOCKOUT SIZE (INCHES)
3/4, 1, 1-1/4
3/4, 1, 1-1/4
3/4, 1, 1-1/4
LOW VOLTAGE
CONDUIT KNOCKOUT SIZE (INCHES)
1/2
1/2
1/2
22 / 50
22 / 50
22 / 50
660 / 420
660 / 420
660 / 420
SHIPPING WEIGHT (LBS.)
440
520
533
OPERATING WEIGHT (LBS.)
430
510
523
EXPANSION DEVICE (ID/OD)
LO PRESSURE SWITCH
OPENS / CLOSES PSIG
HI PRESSURE SWITCH - OPENS PSIG
OPENS / CLOSES PSIG
(1)
*
Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.
Calculated external filter size based on air velocity of 300 ft/min.
Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information.
IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers
in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters.
9
ACCESSORIES
GPH13[24-60]M41*
ACCESSORIES - GPC/GPH****M MODELS
Part Number
Description
OT18-60A
Outdoor Thermostat Kit w/Lockout Stat
OT/EHR18-60
Emergency Heat Relay Kit
HKR
Electric Heat Kit
PGC101/102/103
Roof Curb
PEHH101/102
Horizontal Economizer For Heat Pump, Small and Medium Chassis
PEHH103
Horizontal Economizer For Heat Pump, Large Chassis
PEHC101/102
Horizontal Economizer For A/C, Small and Medium Chassis
PEHC103
Horizontal Economizer For A/C, Large Chassis
PGMDD101/102
Manual 25% Fresh Air Damper Downflow Application, Small and Medium Chassis
PGMDD103
Manual 25% Fresh Air Damper Downflow Application, Large Chassis
PGMDH102
Manual 25% Fresh Air Damper Horizontal Application, Medium Chassis
PGMDH103
Manual 25% Fresh Air Damper Horizontal Application, Large Chassis
PGMDMD101/102
Motorized 25% Fresh Air Damper Downflow Application,Small and Medium Chassis
PGMDMD103
Motorized 25% Fresh Air Downflow Application, Large Chassis
PGMDMH102
Motorized 25% Fresh Air Damper Horizontal Application, Medium Chassis
PGMDMH103
Motorized 25% Fresh Air Damper Horizontal Application, Large Chassis
GPC13MED102
Downflow Economizer For A/C, Medium Chassis
GPC13MED103
Downflow Economizer For A/C, Large Chassis
GPH13MED102
Downflow Economizer For Heat Pump, Medium Chassis
GPH13MED103
Downflow Economizer For Heat Pump, Large Chassis
GPH13MFR102
Internal Filter Rack, Medium Chassis
GPH13MFR103
Internal Filter Rack, Large Chassis
GPGHFR101-103
External Horizontal Filter Rack for Goodman/Amana Gas/Electric and Multi-position Package Units All Chassis
SQRPG101/102
Square to Round Adapter w/ 16" Round Downflow Application, Medium Chassis
SQRPG103
Square to Round Adapter w/ 18" Round Downflow Application, Large Chassis
SQRPGH101/102
Square to Round Adapter w/ 16" Round Horizontal Application, Medium Chassis
SQRPGH103
Square to Round Adapter w/ 18" Round Horizontal Application, Large Chassis
CDK36
Flush Mount Concentric Duct Kit
CDK36515
Flush Mount Concentric Duct Kit w/ Filter
CDK36530
Step Down Concentric Duct Kit
CDK36535
Step Down Concentric Duct Kit w/ Filter
CDK4872
Flush Mount Concentric Duct Kit
CDK4872515
Flush Mount Concentric Duct Kit w/ Filter
CDK4872530
Step Down Concentric Duct Kit
CDK4872535
Step Down Concentric Duct Kit w/ Filter
NOTE: Complete lineup of thermostats can be found in the Thermostat Specification Sheets.
10
GPH13[24-60]M41*
BLOWER PERFORMANCE DATA
Speed
Low
230
Med
230
High
230
Low
230
Med
230
High
230
Low
230
Med
230
High
230
Low
230
Med
230
High
230
T1 (G)
230
T2 / T3
(W 2)
230
T4 / T5
(Y)
230
T1 (G)
230
T2 / T3
W2
230
T4 / T5
Y
230
GPH1360M41*
GPH1348M41*
GPH1342M41*
GPH1336M41*
GPH1330M41*
Model
GPH1324M41*
Dry Coil Data
Volts
E.S.P (In. of H 2O)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
667
153
897
233
1242
373
1097
337
1253
397
596
150
841
229
1181
364
1059
330
1204
388
--------------784
224
1122
354
1016
324
1148
379
--------------713
217
1057
344
959
315
1097
369
--------------610
207
982
333
901
305
1033
356
----- ------- ------- ------- --883
318
818
290
952
342
----- ------- ------- ------- --719
298
648
271
777
313
--- ------- ------- ------- ----617
284
562
257
670
297
CFM
WATTS
CFM
WATTS
1448
499
1122
338
1380
483
1078
330
1323
472
1032
321
1258
459
972
310
1194
446
915
300
1106
427
804
283
1008
410
687
264
864
382
558
250
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
1387
456
1521
534
1122
338
1387
456
1521
534
1,440
1331
440
1454
521
1078
330
1331
440
1454
521
1,395
1264
428
1388
510
1032
321
1264
428
1388
510
1,360
1209
412
1311
490
972
310
1209
412
1311
490
1,310
1119
399
1230
477
915
300
1119
399
1230
477
1,265
1041
382
1144
461
804
283
1041
382
1144
461
1,235
935
363
1055
442
687
264
935
363
1055
442
1,190
748
330
939
420
558
250
748
330
939
420
1,130
275
1,795
475
1,860
285
1,765
490
1,820
295
1,715
505
1,785
315
1,695
520
1,745
325
1,650
530
1,700
335
1,600
535
1,625
345
1,500
510
1,515
355
1,375
475
1,395
515
1,755
420
1,850
480
2,180
770
530
1,720
435
1,820
500
2,125
755
545
1,685
455
1,775
515
2,050
725
565
1,645
460
1,735
525
1,975
700
570
1,615
475
1,705
535
1,875
675
550
1,570
490
1,675
555
1,800
640
535
1,530
500
1,610
545
1,655
575
485
1,465
500
1,495
520
1,530
540
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
NOTES:
•
•
•
•
Data shown is Dry Coil. Wet Coil Pressure Drop is approximate. 0.1" H2O, for 2 row indoor coil; 0.2” H2O, for 3 row indoor
coil; and 0.3” H2O, for 4 row indoor coil.
Data shown does not include filter pressure drop, approx. 0.08” H2O.
ALL MODELS SHOULD RUN NO LESS THAN 350 CFM / TON.
Reduce airflow by 2% for 208V operation.
11
12
10
20
30
40
50
60
70
30
80
90
100
40
50
60
700
600 CFM
90
100
2000
2200
2400 CFM
1800
1600
1400
OUTPUT BTU/HR x 1000
80
1200
1100
1000
900
70
800
FORMULAS
110
120
130
140
BTU OUTPUT = CFM x 1.08 x RISE
BTU OUTPUT
RISE =
÷ CFM
1.08
BTU OUTPUT vs TEMPERATURE RISE CHART
150
BLOWER PERFORMANCE DATA
TEMPERATURE RISE
EXPANDED PERFORMANCE DATA
*
75
70
22.8
0.74
19
1.68
7.3
229
111
21.1
0.71
19
1.64
7.1
222
108
23.9
0.88
21
1.71
7.4
233
114
23.2
0.84
22
1.70
7.4
231
113
21.4
0.81
22
1.66
7.2
224
109
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
825
723
22.1
0.72
20
1.69
7.3
241
116
24.6
0.78
19
1.74
7.6
251
121
23.9
0.75
20
1.73
7.5
249
120
21.8
0.59
16
1.68
7.3
239
115
23.7
0.61
16
1.72
7.4
246
119
24.4
0.64
16
1.73
7.5
249
120
23.9
0.55
17
1.74
7.5
255
127
26.7
0.59
16
1.79
7.7
265
132
25.9
0.57
16
1.78
7.7
263
131
23.9
0.41
12
1.73
7.5
252
126
25.9
0.43
12
1.77
7.6
260
129
26.7
0.45
12
1.78
7.7
263
131
25.6
0.35
11
1.79
7.7
266
135
28.6
0.38
11
1.85
8.0
277
141
27.8
0.36
11
1.83
7.9
274
139
-
-
-
20.9
0.84
22
1.78
7.7
252
115
23.4
0.91
21
1.83
7.9
262
120
22.7
0.87
22
1.82
7.8
259
119
20.6
0.73
19
1.76
7.6
249
114
22.3
0.76
19
1.80
7.8
257
118
23.0
0.80
18
1.82
7.8
259
119
21.6
0.75
20
1.81
7.8
271
123
24.1
0.81
19
1.87
8.0
282
128
23.4
0.77
20
1.85
8.0
279
127
21.3
0.61
17
1.80
7.7
268
122
23.1
0.64
16
1.84
7.9
276
125
23.8
0.67
16
1.85
8.0
279
127
23.3
0.57
17
1.87
8.0
286
134
26.0
0.61
16
1.93
8.3
298
140
25.3
0.59
17
1.91
8.2
295
138
23.4
0.43
13
1.85
8.0
283
133
25.3
0.44
12
1.90
8.1
292
137
26.1
0.46
12
1.91
8.2
295
138
25.0
0.36
12
1.92
8.3
298
143
27.9
0.40
11
1.99
8.5
310
149
27.1
0.38
11
1.97
8.4
307
147
-
-
-
20.4
0.86
22
1.88
8.2
286
120
22.8
0.93
21
1.94
8.4
298
125
22.1
0.89
22
1.93
8.4
295
124
20.1
0.75
19
1.87
8.1
283
119
21.8
0.78
19
1.91
8.3
292
122
22.4
0.82
18
1.93
8.4
295
124
21.0
0.77
21
1.92
8.4
308
128
23.5
0.83
19
1.98
8.6
321
133
22.8
0.79
20
1.97
8.5
317
132
20.8
0.63
17
1.90
8.3
305
126
22.6
0.65
16
1.95
8.5
314
130
23.2
0.68
16
1.97
8.5
317
132
22.8
0.58
17
1.98
8.6
325
139
25.4
0.63
16
2.04
8.8
338
145
24.7
0.60
17
2.03
8.8
335
144
22.8
0.44
13
1.96
8.5
322
138
24.7
0.45
12
2.01
8.7
332
142
25.5
0.47
12
2.03
8.8
335
144
Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is ACCA (TVA) conditions
High and low pressures are measured at the liquid and suction access fittings.
723
825
927
927
23.5
0.77
18
1.69
7.4
231
113
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
24.4
0.37
12
2.04
8.8
339
148
27.3
0.41
11
2.11
9.1
353
154
26.5
0.39
11
2.09
9.1
350
153
-
-
-
19.9
0.88
22
1.97
8.6
326
126
22.2
0.96
21
2.04
8.9
339
131
21.6
0.92
22
2.02
8.8
336
130
19.6
0.78
19
1.96
8.6
323
125
21.2
0.81
19
2.00
8.8
333
129
21.9
0.85
18
2.02
8.8
336
130
20.5
0.79
21
2.01
8.8
351
134
22.9
0.86
20
2.08
9.1
365
140
22.2
0.82
20
2.06
9.0
361
138
20.3
0.65
17
2.00
8.8
347
133
22.0
0.67
17
2.05
9.0
358
137
22.7
0.71
16
2.06
9.0
361
138
22.2
0.60
17
2.08
9.1
370
146
24.8
0.65
16
2.14
9.4
386
152
24.1
0.62
17
2.13
9.3
382
151
22.3
0.45
13
2.06
9.0
367
145
24.1
0.47
13
2.11
9.2
378
149
24.8
0.49
12
2.13
9.3
382
151
18.9
0.92
22
2.05
9.1
367
132
21.1
1.00
21
2.12
9.4
382
138
20.5
0.95
22
2.10
9.3
378
136
18.6
0.81
19
2.04
9.0
363
131
20.2
0.84
19
2.09
9.2
374
135
20.8
0.88
18
2.10
9.3
378
136
19.5
0.82
20
2.10
9.3
394
140
21.8
0.89
19
2.16
9.6
411
146
21.1
0.85
20
2.15
9.5
407
145
19.3
0.67
17
2.08
9.2
390
139
20.9
0.70
16
2.13
9.4
403
143
21.5
0.73
16
2.15
9.5
407
145
21.1
0.62
17
2.16
9.6
417
153
23.6
0.68
16
2.23
9.9
434
160
22.9
0.64
16
2.21
9.8
429
158
21.1
0.47
13
2.14
9.5
412
152
22.9
0.48
12
2.20
9.7
425
157
23.6
0.51
12
2.21
9.8
429
158
22.7
0.40
12
2.23
9.9
434
163
25.3
0.43
11
2.30
10.2
452
170
24.5
0.41
11
2.29
10.1
448
168
-
-
-
17.5
0.93
21
2.12
9.6
405
137
19.6
1.00
19
2.19
9.9
422
142
19.0
0.96
20
2.17
9.8
418
141
17.3
0.81
18
2.10
9.5
401
135
18.7
0.84
18
2.15
9.7
413
139
19.3
0.89
17
2.17
9.8
417
141
63
18.1
0.83
19
2.16
9.8
436
145
20.2
0.90
18
2.24
10.1
454
151
19.6
0.86
19
2.22
10.0
449
150
17.9
0.68
15
2.15
9.7
431
144
19.4
0.71
15
2.20
9.9
445
148
20.0
0.74
15
2.22
10.0
449
150
67
19.6
0.63
16
2.23
10.0
460
159
21.8
0.68
15
2.31
10.4
479
165
21.2
0.65
15
2.29
10.3
474
164
19.6
0.47
12
2.22
10.0
456
157
21.2
0.49
12
2.27
10.2
470
162
21.9
0.51
11
2.29
10.3
474
164
21.0
0.40
11
2.31
10.4
480
169
23.4
0.44
10
2.38
10.7
500
176
22.7
0.42
11
2.36
10.6
495
174
-
-
-
71
KW = Total system power
AMPS: Unit amps (comp.+ evaporator + condenser fan motors)
23.8
0.39
12
2.14
9.4
386
156
26.6
0.42
11
2.21
9.7
402
162
25.8
0.40
11
2.20
9.6
398
161
-
-
-
115
COOLING OPERATION
Design Subcooling, 10 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 10 +/- 2 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65
75
85
95
105
Entering Indoor Wet Bulb Temperature
IDB* Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
MODEL: GPH1324M41*
COOLING PERFORMANCE DATA
GPH1324M41*
13
14
EXPANDED PERFORMANCE DATA
*
85
24.0
0.96
26
1.72
7.5
236
115
22.2
0.93
26
1.68
7.3
229
111
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
825
723
22.6
0.89
26
1.72
7.4
246
119
24.5
0.93
25
1.76
7.6
254
122
25.2
0.97
24
1.77
7.7
256
123
23.7
0.81
24
1.77
7.6
260
129
25.7
0.84
24
1.81
7.8
268
133
26.4
0.88
23
1.82
7.9
271
135
25.3
0.65
21
1.82
7.9
271
138
27.4
0.68
21
1.86
8.0
279
142
28.2
0.71
20
1.88
8.1
282
144
21.7
0.96
26
1.80
7.8
257
118
23.5
1.00
26
1.85
7.9
265
121
24.2
1.00
24
1.86
8.0
267
123
22.1
0.93
26
1.84
7.9
276
125
23.9
0.96
26
1.88
8.1
285
129
24.7
1.00
24
1.90
8.2
288
130
23.1
0.84
25
1.90
8.1
292
137
25.1
0.87
24
1.94
8.3
301
141
25.8
0.91
23
1.96
8.4
304
142
24.7
0.68
21
1.95
8.4
304
146
26.8
0.70
21
2.00
8.6
314
150
27.6
0.74
20
2.02
8.6
317
152
21.2
0.98
27
1.91
8.3
292
122
22.9
1.00
26
1.96
8.5
301
126
23.6
1.00
23
1.97
8.6
304
127
21.6
0.95
26
1.95
8.5
314
130
23.4
0.99
26
2.00
8.7
324
134
24.1
1.00
24
2.01
8.7
327
136
22.6
0.86
25
2.01
8.7
332
142
24.5
0.89
24
2.06
8.9
342
147
25.2
0.93
23
2.07
9.0
345
148
Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is AHRI Rating Conditions
High and low pressures are measured at the liquid and suction access fittings.
927
24.8
1.00
25
1.73
7.5
238
116
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
24.1
0.70
21
2.07
9.0
346
151
26.1
0.72
21
2.12
9.2
357
156
26.9
0.76
20
2.14
9.3
360
158
20.6
1.00
26
2.00
8.8
332
129
22.4
1.00
25
2.05
9.0
343
133
23.0
1.00
23
2.07
9.1
346
134
21.0
0.98
26
2.05
9.0
358
137
22.8
1.00
25
2.10
9.2
369
141
23.5
1.00
23
2.11
9.2
372
142
22.0
0.89
25
2.11
9.2
378
149
23.9
0.92
24
2.16
9.4
389
154
24.6
0.96
23
2.18
9.5
393
155
19.6
1.00
25
2.08
9.2
374
135
21.2
1.00
24
2.14
9.5
386
139
21.9
1.00
22
2.15
9.5
389
140
20.0
1.00
25
2.13
9.4
402
143
21.7
1.00
24
2.18
9.7
415
148
22.3
1.00
22
2.20
9.7
419
149
20.9
0.92
24
2.20
9.7
425
156
22.7
0.95
24
2.25
9.9
438
161
23.4
1.00
23
2.27
10.0
442
163
22.3
0.75
21
2.27
10.0
443
167
24.2
0.77
21
2.32
10.3
457
172
24.9
0.81
20
2.34
10.3
462
174
18.2
1.00
23
2.15
9.7
413
139
19.7
1.00
22
2.21
9.9
426
144
20.3
1.00
20
2.22
10.0
430
145
18.5
1.00
24
2.20
9.9
445
148
20.1
1.00
22
2.25
10.2
458
153
20.7
1.00
20
2.27
10.2
463
154
19.4
0.93
23
2.27
10.2
470
162
21.0
0.96
23
2.33
10.4
484
167
21.6
1.00
21
2.35
10.5
489
169
67
21.8
0.84
18
2.33
10.4
484
167
21.1
0.80
19
2.31
10.4
479
165
19.5
0.77
19
2.25
10.1
465
160
20.7
0.75
20
2.34
10.5
490
172
22.4
0.78
19
2.40
10.8
505
178
23.1
0.82
19
2.42
10.9
510
179
71
23.3
0.63
15
2.40
10.8
505
178
22.6
0.60
15
2.38
10.7
500
176
20.8
0.58
15
2.32
10.4
485
171
KW = Total system power
AMPS: Unit amps (comp.+ evaporator + condenser fan motors)
23.5
0.72
21
2.18
9.5
394
159
25.5
0.74
21
2.23
9.7
406
164
26.2
0.78
20
2.25
9.8
410
166
63
20.4
1.00
20
2.25
10.2
458
153
19.8
0.99
22
2.24
10.1
454
151
18.2
0.95
22
2.18
9.8
440
147
115
COOLING OPERATION
Design Subcooling, 10 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 10 +/- 2 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65
75
85
95
105
Entering Indoor Wet Bulb Temperature
IDB* Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
MBh
24.3 24.9 26.6 28.4 23.8 24.3 26.0 27.7 23.2
23.7
25.3 27.1 22.6
23.1
24.7
26.4 21.5 22.0 23.5 25.1 19.9
S/T
0.96 0.90 0.73 0.55 1.00 0.93 0.76 0.57 1.00
0.96
0.78 0.58 1.00
1.00
0.80
0.60 1.00 1.00 0.84 0.62 1.00
Delta T 23
22
19
15
24
23
20
16
23
23
20
16
22
23
20
16
21
22
19
16
20
927
KW
1.72 1.76 1.81 1.86 1.85 1.88 1.94 2.00 1.96
2.00
2.06 2.12 2.05
2.10
2.16
2.23 2.14 2.18 2.25 2.32 2.21
AMPS 7.5
7.6
7.8
8.0
7.9
8.1
8.3
8.6
8.5
8.7
8.9
9.2
9.0
9.2
9.4
9.7
9.5
9.7
9.9
10.3
9.9
HI PR 236
254
268
279
265
285
301
314
301
324
342
357
343
369
389
406
386
415
438
457
426
LO PR 115
122
133
142
121
129
141
150
126
134
147
156
133
141
154
164
139
148
161
172
144
MBh
23.6 24.1 25.8 27.6 23.1 23.6 25.2 26.9 22.5
23.0
24.6 26.3 22.0
22.5
25.7 20.9 21.3 22.8 24.4 19.3
24.0
S/T
0.92 0.86 0.70 0.52 0.95 0.89 0.73 0.54 0.97
0.91
0.74 0.56 1.00
0.94
0.57 1.00 0.98 0.80 0.60 1.00
0.77
Delta T 24
23
20
16
24
23
20
16
24
23
20
16
24
24
16
23
23
20
16
22
21
2.15
80
825
KW
1.71 1.74 1.79 1.85 1.83 1.87 1.93 1.99 1.94
1.98
2.04 2.11 2.04
2.08
2.21 2.12 2.16 2.23 2.30 2.19
9.4
AMPS 7.4
7.6
7.7
8.0
7.9
8.0
8.3
8.5
8.4
8.6
8.8
9.1
8.9
9.1
9.7
9.4
9.6
9.9
10.2
9.9
HI PR 233
251
265
277
262
282
298
310
298
321
339
353
339
365
402
382
411
434
452
422
386
LO PR 114
121
132
141
120
128
140
149
125
133
145
155
131
140
162
138
146
160
170
142
152
MBh
21.8 22.3 23.8 25.5 21.3 21.8 23.3 24.9 20.8
21.3
22.7 24.3 20.3
20.7
22.2
23.7 19.3 19.7 21.0 22.5 17.9
S/T
0.88 0.83 0.67 0.50 0.92 0.86 0.70 0.52 0.94
0.88
0.72 0.54 0.97
0.91
0.74
0.55 1.01 0.94 0.77 0.57 1.01
Delta T 25
24
20
16
25
24
21
17
25
24
21
17
25
24
21
17
25
24
21
16
23
723
KW
1.67 1.70 1.75 1.81 1.79 1.83 1.88 1.94 1.90
1.93
1.99 2.06 1.99
2.03
2.09
2.16 2.07 2.11 2.18 2.25 2.14
AMPS 7.3
7.4
7.6
7.8
7.7
7.9
8.1
8.3
8.3
8.4
8.6
8.9
8.7
8.9
9.1
9.4
9.2
9.4
9.6
9.9
9.6
HI PR 226
244
257
268
254
273
289
301
289
311
328
342
329
354
374
390
370
398
421
439
409
LO PR 110
117
128
136
117
124
135
144
121
129
141
150
127
135
148
157
133
142
155
165
138
MODEL: GPH1324M41*
COOLING PERFORMANCE DATA
GPH1324M41*
EXPANDED PERFORMANCE DATA
*
75
70
27.6
0.74
18
2.18
9.4
229
108
25.5
0.71
18
2.14
9.2
223
105
28.9
0.88
20
2.22
9.6
234
110
28.1
0.84
21
2.20
9.5
232
109
25.9
0.81
21
2.15
9.3
225
106
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1050
920
1180
28.9
0.75
19
2.24
9.7
249
116
26.7
0.72
19
2.19
9.5
242
112
29.8
0.78
18
2.26
9.8
252
117
26.4
0.59
16
2.18
9.4
240
111
28.6
0.61
15
2.23
9.6
247
115
29.5
0.64
15
2.24
9.7
249
116
31.3
0.57
15
2.31
9.9
263
126
28.9
0.55
16
2.26
9.7
256
123
32.2
0.59
15
2.33
10.0
266
128
28.9
0.41
12
2.24
9.7
253
121
31.3
0.43
12
2.29
9.9
261
125
32.3
0.45
11
2.31
9.9
263
126
33.6
0.36
11
2.38
10.3
275
135
31.0
0.35
11
2.33
10.0
267
131
34.6
0.38
10
2.40
10.3
277
136
-
-
-
27.4
0.87
21
2.36
10.1
260
115
25.3
0.83
21
2.31
9.9
252
112
28.2
0.91
20
2.38
10.2
263
116
24.9
0.73
18
2.29
9.8
250
110
26.9
0.76
18
2.34
10.1
257
114
27.8
0.80
17
2.36
10.1
260
115
28.2
0.77
19
2.41
10.3
280
122
26.0
0.75
19
2.35
10.1
272
119
29.1
0.81
18
2.43
10.4
283
124
25.8
0.61
16
2.33
10.0
269
117
27.9
0.64
16
2.39
10.3
277
121
28.8
0.67
15
2.41
10.3
280
122
30.5
0.59
16
2.48
10.6
296
134
28.2
0.57
16
2.42
10.4
287
130
31.5
0.61
15
2.50
10.7
299
135
28.2
0.42
12
2.41
10.3
284
128
30.6
0.44
12
2.46
10.5
293
132
31.5
0.46
11
2.48
10.6
296
134
32.8
0.38
11
2.56
10.9
308
142
30.3
0.36
11
2.50
10.7
299
138
33.8
0.40
10
2.58
11.0
311
144
-
-
-
26.8
0.89
21
2.50
10.9
296
120
24.7
0.86
21
2.44
10.6
287
116
27.6
0.93
20
2.52
10.9
299
121
24.3
0.75
18
2.42
10.5
284
115
26.3
0.78
18
2.48
10.8
293
118
27.1
0.82
17
2.50
10.9
296
120
27.5
0.79
19
2.55
11.1
318
127
25.4
0.77
19
2.49
10.8
309
123
28.4
0.83
18
2.57
11.2
322
128
25.2
0.63
16
2.47
10.7
306
122
27.3
0.65
16
2.53
11.0
315
126
28.1
0.68
15
2.55
11.1
318
127
29.8
0.60
16
2.63
11.4
336
139
27.5
0.58
16
2.57
11.1
326
135
30.7
0.63
15
2.65
11.5
340
140
27.6
0.44
12
2.55
11.0
323
133
29.9
0.45
12
2.61
11.3
333
137
30.8
0.47
11
2.63
11.4
336
139
Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is ACCA (TVA) conditions
High and low pressures are measured at the liquid and suction access fittings.
920
1050
1180
28.4
0.77
17
2.20
9.5
232
109
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
32.0
0.39
11
2.72
11.7
351
148
29.5
0.37
11
2.65
11.5
340
143
33.0
0.41
10
2.74
11.8
354
149
-
-
-
26.1
0.92
21
2.63
11.5
337
126
24.1
0.88
21
2.56
11.2
327
122
26.9
0.96
20
2.65
11.6
340
127
23.7
0.78
18
2.54
11.1
324
121
25.7
0.81
18
2.60
11.4
334
124
26.4
0.85
17
2.63
11.5
337
126
24.8
0.79
20
2.62
11.4
352
130
26.9
0.82
19
2.68
11.7
363
134
27.7
0.86
19
2.70
11.8
366
135
24.6
0.65
16
2.60
11.4
348
128
26.6
0.67
16
2.66
11.6
359
132
27.4
0.71
15
2.68
11.7
363
134
29.1
0.62
16
2.76
12.0
383
146
26.8
0.60
16
2.70
11.8
371
141
30.0
0.65
15
2.79
12.1
387
147
26.9
0.45
12
2.68
11.7
368
140
29.1
0.47
12
2.74
12.0
379
144
30.0
0.49
11
2.76
12.0
383
146
24.8
0.95
21
2.73
12.1
379
132
22.9
0.92
21
2.67
11.8
368
128
25.5
1.00
20
2.75
12.2
383
133
22.5
0.81
18
2.64
11.7
364
126
24.4
0.84
18
2.71
12.0
375
130
25.1
0.88
17
2.73
12.1
379
132
25.5
0.85
19
2.79
12.4
408
140
23.6
0.82
19
2.72
12.1
396
136
26.3
0.89
18
2.81
12.5
412
141
23.3
0.67
16
2.70
12.0
392
134
25.3
0.70
15
2.77
12.3
404
139
26.0
0.73
15
2.79
12.4
408
140
27.6
0.64
16
2.88
12.7
431
153
25.5
0.62
16
2.81
12.4
418
148
28.5
0.68
15
2.90
12.8
435
154
25.6
0.47
12
2.78
12.3
414
147
27.7
0.48
12
2.85
12.6
426
151
28.5
0.51
11
2.88
12.7
431
153
29.7
0.41
11
2.97
13.1
449
163
27.4
0.40
11
2.90
12.8
436
158
30.5
0.43
10
2.99
13.2
454
164
-
-
-
23.0
0.96
19
2.82
12.7
419
136
21.2
0.92
20
2.75
12.4
406
132
23.7
1.00
18
2.84
12.8
423
137
20.8
0.81
17
2.73
12.3
402
131
22.6
0.84
17
2.80
12.6
415
135
23.3
0.88
16
2.82
12.7
419
136
63
23.6
0.86
18
2.88
13.0
451
145
21.8
0.83
18
2.81
12.7
437
140
24.4
0.90
17
2.91
13.1
455
146
21.6
0.68
15
2.79
12.6
433
139
23.4
0.70
14
2.86
12.9
446
143
24.1
0.74
14
2.88
13.0
451
145
67
25.6
0.65
15
2.97
13.4
476
158
23.6
0.63
15
2.90
13.0
462
153
26.4
0.68
14
3.00
13.5
481
160
23.7
0.47
11
2.88
12.9
457
152
25.6
0.49
11
2.95
13.3
471
156
26.4
0.51
11
2.97
13.4
476
158
27.5
0.42
10
3.07
13.8
496
168
25.4
0.40
10
3.00
13.5
481
163
28.3
0.44
10
3.10
13.9
501
170
-
-
-
71
KW = Total system power
AMPS: Unit amps (comp.+ evaporator + condenser fan motors)
31.2
0.40
11
2.85
12.4
399
155
28.8
0.38
11
2.78
12.1
387
151
32.2
0.42
10
2.88
12.5
403
157
-
-
-
115
COOLING OPERATION
Design Subcooling, 10 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 10 +/- 2 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65
75
85
95
105
Entering Indoor Wet Bulb Temperature
IDB* Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
MODEL: GPH1330M41*
COOLING PERFORMANCE DATA
GPH1330M41*
15
16
EXPANDED PERFORMANCE DATA
*
85
29.9
1.00
23
2.25
9.7
239
112
29.1
0.96
24
2.23
9.6
236
111
26.8
0.93
25
2.18
9.4
229
108
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
920
1180
29.6
0.93
24
2.28
9.8
255
118
27.3
0.89
24
2.23
9.6
247
115
30.5
0.97
23
2.30
9.9
257
119
26.9
0.83
22
2.21
9.5
244
113
31.0
0.84
23
2.35
10.1
269
129
28.6
0.81
23
2.29
9.9
261
125
31.9
0.88
22
2.37
10.2
271
130
28.8
0.67
19
2.28
9.8
258
124
33.1
0.68
20
2.42
10.4
280
137
30.5
0.65
20
2.36
10.2
272
133
34.1
0.71
19
2.44
10.5
283
139
30.8
0.50
15
2.34
10.1
269
132
28.4
1.00
25
2.40
10.3
265
117
26.2
0.96
25
2.34
10.0
257
114
29.2
1.00
23
2.42
10.4
268
119
25.7
0.92
24
2.32
10.0
255
113
28.9
0.96
24
2.45
10.5
286
125
26.7
0.93
25
2.39
10.2
277
121
29.8
1.00
23
2.46
10.6
288
126
26.3
0.86
23
2.37
10.2
274
120
30.3
0.87
23
2.52
10.8
302
136
28.0
0.84
23
2.46
10.5
293
132
31.2
0.91
22
2.54
10.9
305
138
28.1
0.70
20
2.44
10.5
290
131
32.3
0.70
20
2.60
11.1
315
145
29.8
0.68
20
2.54
10.9
305
141
33.3
0.74
19
2.62
11.2
318
147
30.0
0.52
16
2.52
10.8
302
139
27.7
1.00
24
2.54
11.0
302
122
25.6
0.98
25
2.48
10.8
293
118
28.5
1.00
22
2.56
11.1
305
123
25.1
0.94
24
2.46
10.7
290
117
28.2
0.99
24
2.59
11.2
325
130
26.1
0.95
25
2.53
11.0
315
126
29.1
1.00
23
2.61
11.3
328
131
25.7
0.88
23
2.51
10.9
312
125
29.6
0.89
23
2.67
11.6
343
142
27.3
0.86
23
2.61
11.3
333
137
30.5
0.93
22
2.70
11.7
346
143
27.4
0.72
20
2.59
11.2
329
136
Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is AHRI Rating Conditions
High and low pressures are measured at the liquid and suction access fittings.
920
1050
26.4
0.88
23
2.17
9.4
227
107
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
31.6
0.72
20
2.76
11.9
358
151
29.1
0.70
20
2.69
11.7
347
146
32.5
0.76
19
2.78
12.0
361
152
29.3
0.54
16
2.67
11.6
344
145
27.0
1.00
24
2.67
11.7
344
128
24.9
1.00
25
2.60
11.4
333
124
27.8
1.00
22
2.69
11.8
347
129
24.5
0.97
24
2.58
11.3
330
123
27.6
1.00
24
2.72
11.9
370
136
25.4
0.98
25
2.66
11.6
359
132
28.4
1.00
22
2.75
12.0
374
138
25.1
0.91
23
2.64
11.5
355
131
28.9
0.92
23
2.81
12.2
391
149
26.6
0.88
24
2.74
12.0
379
144
29.7
0.96
22
2.83
12.3
395
150
26.8
0.74
20
2.72
11.9
375
143
25.7
1.00
22
2.78
12.3
387
134
23.7
1.00
24
2.71
12.0
375
130
26.4
1.00
21
2.80
12.4
391
136
23.3
1.01
23
2.69
11.9
371
129
26.2
1.00
23
2.83
12.6
416
143
24.2
1.00
24
2.77
12.3
404
139
27.0
1.00
21
2.86
12.7
420
144
23.8
0.94
22
2.74
12.2
400
137
27.4
0.95
23
2.92
12.9
439
156
25.3
0.92
23
2.85
12.6
426
151
28.2
1.00
22
2.95
13.0
444
157
25.4
0.77
20
2.83
12.5
422
150
29.2
0.77
20
3.02
13.3
458
166
27.0
0.75
20
2.95
13.0
445
161
30.1
0.81
19
3.04
13.5
463
168
27.2
0.57
16
2.92
12.9
440
159
23.8
1.00
21
2.87
12.9
427
139
22.0
1.00
22
2.80
12.6
414
135
24.5
1.00
19
2.89
13.0
432
140
21.6
1.01
22
2.78
12.5
410
133
24.2
1.00
21
2.93
13.2
460
148
22.4
1.00
22
2.86
12.9
446
143
25.0
1.00
19
2.95
13.3
464
149
22.0
0.95
21
2.84
12.8
442
142
25.4
0.96
21
3.02
13.6
486
161
23.4
0.93
22
2.95
13.3
471
156
26.2
1.00
20
3.05
13.7
490
163
23.6
0.77
18
2.93
13.2
466
155
67
26.3
0.84
17
3.02
13.6
486
161
25.5
0.80
18
3.00
13.5
481
160
27.1
0.78
18
3.12
14.0
506
172
25.0
0.75
19
3.05
13.7
491
167
27.9
0.82
18
3.15
14.2
511
173
25.2
0.58
15
3.02
13.6
486
165
71
28.1
0.63
14
3.12
14.0
506
172
27.3
0.60
14
3.10
13.9
501
170
KW = Total system power
AMPS: Unit amps (comp.+ evaporator + condenser fan motors)
30.8
0.74
20
2.90
12.6
407
158
28.4
0.72
20
2.83
12.3
395
154
31.7
0.78
19
2.92
12.7
411
160
28.6
0.55
16
2.81
12.2
391
152
63
24.6
1.00
19
2.93
13.2
460
148
23.9
0.99
21
2.91
13.1
455
146
115
COOLING OPERATION
Design Subcooling, 10 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 10 +/- 2 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65
75
85
95
105
Entering Indoor Wet Bulb Temperature
IDB* Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
MBh
29.4 30.1 32.1 34.3 28.7 29.4 31.4 33.5 28.0
28.7
30.6 32.7 27.4
28.0
29.9
31.9 26.0 26.6 28.4 30.3 24.1
S/T
0.96 0.90 0.73 0.55 1.00 0.93 0.76 0.57 1.00
0.96
0.78 0.58 1.00
1.00
0.80
0.60 1.00 1.00 0.83 0.62 1.00
Delta T 22
21
18
15
22
21
19
15
22
21
19
15
21
22
19
15
20
21
18
15
19
1180
KW
2.23 2.28 2.35 2.42 2.40 2.45 2.52 2.60 2.54
2.59
2.67 2.76 2.67
2.72
2.81
2.90 2.78 2.83 2.92 3.02 2.87
AMPS 9.6
9.8
10.1 10.4 10.3 10.5 10.8 11.1 11.0
11.2
11.6 11.9 11.7
11.9
12.2
12.6 12.3 12.6 12.9 13.3 12.9
HI PR 236
255
269
280
265
286
302
315
302
325
343
358
344
370
391
407
387
416
439
458
427
LO PR 111
118
129
137
117
125
136
145
122
130
142
151
128
136
149
158
134
143
156
166
139
MBh
28.6 29.2 31.2 33.3 27.9 28.5 30.5 32.6 27.2
27.8
29.7 31.8 26.6
27.1
31.0 25.2 25.8 27.6 29.5 23.4
29.0
S/T
0.92 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.97
0.91
0.74 0.56 1.00
0.94
0.57 1.00 0.98 0.80 0.60 1.00
0.77
Delta T 23
22
19
15
23
22
19
15
23
22
19
15
23
22
16
22
22
19
15
20
19
2.79
80
1050
KW
2.22 2.26 2.33 2.40 2.38 2.43 2.50 2.58 2.52
2.57
2.65 2.74 2.65
2.70
2.88 2.75 2.81 2.90 2.99 2.85
12.1
AMPS 9.6
9.8
10.0 10.3 10.2 10.4 10.7 11.0 10.9
11.2
11.5 11.8 11.6
11.8
12.5 12.2 12.5 12.8 13.2 12.8
HI PR 234
252
266
278
263
283
299
311
299
322
340
354
340
366
403
383
412
435
454
423
387
LO PR 110
117
128
136
116
124
135
144
121
128
140
149
127
135
157
133
141
154
164
137
147
MODEL: GPH1330M41*
COOLING PERFORMANCE DATA
GPH1330M41*
EXPANDED PERFORMANCE DATA
*
75
70
32.9
0.70
19
2.50
10.5
235
111
30.4
0.68
19
2.45
10.3
228
107
34.5
0.84
21
2.54
10.7
240
113
33.5
0.80
21
2.52
10.6
237
112
30.9
0.77
22
2.46
10.3
230
108
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1150
1008
1292
1150
1008
31.8
0.69
20
2.51
10.5
248
115
34.5
0.72
20
2.57
10.8
255
119
35.5
0.75
19
2.59
10.9
258
120
31.5
0.57
16
2.49
10.5
245
114
34.1
0.59
16
2.55
10.7
253
118
35.1
0.62
15
2.57
10.8
255
119
34.4
0.52
16
2.59
10.8
262
126
37.3
0.54
16
2.65
11.1
270
130
38.4
0.57
16
2.67
11.2
272
131
34.5
0.39
12
2.57
10.8
259
125
37.4
0.41
12
2.63
11.0
267
129
38.5
0.43
12
2.65
11.1
270
130
37.0
0.34
11
2.67
11.2
273
134
40.0
0.35
11
2.73
11.4
281
138
41.2
0.37
11
2.75
11.5
284
140
-
-
-
30.2
0.80
22
2.64
11.0
258
115
32.7
0.83
22
2.70
11.3
266
118
33.7
0.87
21
2.72
11.4
269
119
29.7
0.70
19
2.62
11.0
256
113
32.2
0.73
19
2.68
11.2
264
117
33.1
0.76
18
2.70
11.3
266
118
31.1
0.71
20
2.70
11.3
278
122
33.7
0.74
20
2.76
11.5
287
126
34.7
0.78
19
2.78
11.6
289
127
30.8
0.59
16
2.67
11.2
275
121
33.3
0.61
16
2.74
11.4
284
124
34.3
0.64
16
2.76
11.5
287
126
33.6
0.54
17
2.78
11.6
294
133
36.4
0.56
16
2.84
11.9
303
137
37.5
0.59
16
2.86
12.0
306
139
33.7
0.41
13
2.75
11.5
291
132
36.5
0.42
12
2.82
11.8
300
136
37.6
0.44
12
2.84
11.9
303
137
36.1
0.35
11
2.86
11.9
306
142
39.1
0.36
11
2.93
12.2
316
146
40.3
0.38
11
2.95
12.3
319
148
-
-
-
29.5
0.82
22
2.80
11.8
294
119
31.9
0.85
22
2.86
12.1
303
123
32.9
0.89
21
2.89
12.2
306
124
29.0
0.72
19
2.78
11.8
291
118
31.4
0.75
19
2.84
12.0
300
122
32.3
0.78
18
2.86
12.1
303
123
30.3
0.73
20
2.86
12.1
316
127
32.9
0.76
20
2.92
12.4
326
131
33.8
0.80
19
2.95
12.5
329
132
30.0
0.60
16
2.83
12.0
313
125
32.5
0.62
16
2.90
12.3
323
129
33.5
0.65
16
2.92
12.4
326
131
32.8
0.55
17
2.94
12.4
334
138
35.6
0.58
16
3.01
12.7
344
143
36.6
0.60
16
3.04
12.8
348
144
32.9
0.42
13
2.92
12.3
330
137
35.6
0.43
12
2.99
12.6
341
141
36.7
0.45
12
3.01
12.7
344
143
Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is ACCA (TVA) conditions
High and low pressures are measured at the liquid and suction access fittings.
1292
33.9
0.74
18
2.52
10.6
237
112
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
35.2
0.36
11
3.04
12.8
348
147
38.2
0.37
11
3.11
13.2
359
152
39.3
0.39
11
3.13
13.3
363
153
-
-
-
28.7
0.85
22
2.94
12.5
335
125
31.1
0.88
22
3.01
12.9
345
129
32.1
0.92
21
3.03
13.0
348
130
28.3
0.74
19
2.91
12.4
331
124
30.6
0.77
19
2.98
12.8
341
128
31.5
0.81
18
3.01
12.9
345
129
29.6
0.76
20
3.00
12.8
360
133
32.1
0.78
20
3.07
13.1
371
137
33.0
0.82
19
3.09
13.2
375
139
29.3
0.62
17
2.97
12.7
356
132
31.7
0.64
16
3.05
13.0
367
136
32.7
0.68
16
3.07
13.1
371
137
32.0
0.57
17
3.09
13.2
380
145
34.7
0.59
16
3.17
13.5
392
150
35.7
0.62
16
3.19
13.6
396
151
32.1
0.43
13
3.07
13.1
376
144
34.8
0.45
12
3.14
13.4
388
148
35.8
0.47
12
3.17
13.5
392
150
27.3
0.88
22
3.05
13.2
376
131
29.6
0.91
22
3.13
13.6
388
135
30.5
0.95
21
3.15
13.7
392
137
26.9
0.77
19
3.03
13.1
373
130
29.1
0.80
19
3.10
13.5
384
134
30.0
0.84
18
3.13
13.6
388
135
28.1
0.79
20
3.12
13.5
405
139
30.5
0.81
20
3.19
13.9
418
144
31.4
0.85
19
3.22
14.0
422
145
27.8
0.65
16
3.09
13.4
401
138
30.2
0.67
16
3.17
13.8
413
142
31.1
0.70
15
3.19
13.9
418
144
30.4
0.59
16
3.22
13.9
428
152
33.0
0.62
16
3.30
14.3
441
157
34.0
0.65
16
3.32
14.4
445
159
30.5
0.45
12
3.19
13.8
423
151
33.0
0.46
12
3.27
14.2
437
155
34.0
0.49
12
3.29
14.3
441
157
32.7
0.38
11
3.32
14.4
446
162
35.4
0.40
11
3.40
14.8
460
167
36.4
0.42
11
3.43
14.9
465
169
-
-
-
25.3
0.89
20
3.15
13.9
416
136
27.4
0.92
20
3.23
14.3
429
140
28.2
0.96
19
3.26
14.4
433
141
24.9
0.78
18
3.13
13.8
412
134
26.9
0.81
17
3.21
14.2
424
138
27.8
0.85
17
3.23
14.3
429
140
63
26.0
0.79
19
3.22
14.2
448
144
28.2
0.82
19
3.30
14.6
461
149
29.1
0.86
18
3.33
14.7
466
150
25.8
0.65
15
3.20
14.1
443
143
27.9
0.67
15
3.27
14.5
457
147
28.8
0.71
14
3.30
14.6
461
149
67
28.2
0.60
15
3.32
14.7
473
157
30.5
0.62
15
3.41
15.0
487
162
31.5
0.65
15
3.43
15.2
492
164
28.2
0.45
12
3.30
14.5
468
156
30.6
0.47
11
3.38
14.9
482
161
31.5
0.49
11
3.41
15.0
487
162
30.3
0.39
11
3.43
15.2
493
168
32.8
0.40
10
3.52
15.5
508
173
33.8
0.42
10
3.55
15.7
513
175
-
-
-
71
KW = Total system power
AMPS: Unit amps (comp.+ evaporator + condenser fan motors)
34.4
0.37
12
3.19
13.6
397
155
37.2
0.38
11
3.27
14.0
409
160
38.4
0.40
11
3.29
14.1
413
161
-
-
-
115
COOLING OPERATION
Design Subcooling, 9 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 7+/-2 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65
75
85
95
105
Entering Indoor Wet Bulb Temperature
IDB* Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
MODEL: GPH1336M41*
COOLING PERFORMANCE DATA
GPH1336M41*
17
18
EXPANDED PERFORMANCE DATA
*
85
80
37.0
0.80
24
2.69
11.3
275
132
39.5
0.65
21
2.77
11.6
287
141
40.7
0.68
20
2.79
11.7
290
143
33.9
0.95
26
2.75
11.5
272
121
34.9
1.00
25
2.77
11.6
274
122
33.3
0.91
24
2.72
11.4
269
119
30.7
0.88
25
2.66
11.1
261
116
34.5
0.92
25
2.80
11.7
292
128
35.6
0.96
24
2.82
11.8
295
130
34.0
0.85
23
2.78
11.6
289
127
31.4
0.82
24
2.72
11.4
281
123
36.1
0.83
24
2.89
12.0
309
140
37.2
0.87
23
2.91
12.1
312
141
36.3
0.69
20
2.86
12.0
306
139
33.5
0.67
20
2.80
11.7
297
134
38.6
0.67
21
2.98
12.4
322
149
39.7
0.71
20
3.00
12.5
325
151
38.8
0.52
16
2.95
12.3
319
148
35.8
0.50
16
2.88
12.0
309
143
33.1
0.98
26
2.91
12.3
309
125
34.0
1.00
24
2.93
12.4
312
127
32.5
0.93
24
2.89
12.2
306
124
30.0
0.90
25
2.82
11.9
297
120
33.7
0.94
25
2.97
12.6
333
133
34.7
0.99
24
2.99
12.7
336
135
33.2
0.87
23
2.95
12.5
329
132
30.6
0.84
24
2.88
12.2
319
128
35.3
0.85
24
3.06
12.9
351
145
36.3
0.89
23
3.09
13.1
355
147
35.5
0.71
20
3.04
12.8
348
144
32.7
0.69
20
2.97
12.5
337
140
38.8
0.72
20
3.18
13.5
370
156
37.9
0.53
16
3.13
13.3
363
153
35.0
0.51
16
3.06
12.9
352
149
33.2
1.00
24
3.08
13.2
355
133
31.7
0.96
24
3.03
13.0
348
130
29.3
0.93
25
2.96
12.6
338
126
29.8
0.97
26
2.98
12.7
341
128
1150
35.3
0.89
25
2.61
11.0
261
121
38.1
0.84
23
2.71
11.4
278
134
39.8
0.50
16
2.75
11.5
284
140
36.7
0.48
16
2.69
11.3
276
136
MBh 32.0 32.6 34.2 36.4 31.3 31.9 33.4 35.6 30.5
31.1
32.6 34.7
S/T
0.89 0.86 0.77 0.63 0.92 0.89 0.80 0.65 0.94
0.91
0.82 0.67
Delta T 26
25
24
21
26
26
24
21
26
26
24
21
1008
KW
2.50 2.55 2.63 2.71 2.68 2.74 2.82 2.91 2.84
2.90
2.99 3.08
AMPS 10.5 10.7 11.0 11.4 11.2 11.4 11.8 12.1 12.0
12.3
12.6 13.1
HI PR 235
253
267
278
264
284
299
312 300
323
341
355
LO PR 111
118
129
137
117
124
136
145 121
129
141
150
Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is AHRI Rating Conditions
High and low pressures are measured at the liquid and suction access fittings.
34.7
0.92
25
2.56
10.7
242
114
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
36.4
0.93
24
2.63
11.0
263
123
37.2
0.67
20
2.67
11.2
272
131
34.3
0.65
20
2.61
10.9
264
127
32.2
1.00
26
3.05
13.1
352
132
35.7
0.96
24
2.58
10.8
245
115
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
34.8
0.82
23
2.59
10.9
258
120
32.1
0.79
23
2.53
10.6
250
117
37.6
0.69
21
3.16
13.4
366
155
1292
1008
1150
34.1
0.88
24
2.54
10.7
240
113
31.4
0.85
24
2.48
10.4
233
110
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
30.3
0.94
26
3.04
13.0
367
136
32.9
0.97
26
3.12
13.3
379
140
33.9
1.00
24
3.14
13.4
383
141
32.4
0.90
23
3.09
13.2
375
139
29.9
0.87
24
3.02
12.9
364
134
31.8
0.85
25
3.14
13.4
388
148
34.4
0.88
24
3.22
13.7
400
153
35.5
0.92
23
3.24
13.8
404
154
34.6
0.73
20
3.19
13.6
396
151
31.9
0.71
21
3.12
13.3
384
147
30.6
1.00
24
3.18
13.8
396
138
31.6
1.00
22
3.20
13.9
400
139
30.1
1.00
24
3.15
13.7
392
137
27.8
0.96
24
3.08
13.4
380
132
31.2
1.00
25
3.25
14.1
426
147
32.2
1.00
23
3.27
14.2
430
148
30.8
0.94
23
3.22
14.0
422
145
28.4
0.90
23
3.14
13.6
409
141
32.7
0.91
24
3.35
14.5
450
160
33.7
0.96
23
3.38
14.6
454
162
32.9
0.76
20
3.32
14.4
445
159
30.3
0.74
20
3.24
14.0
432
154
34.9
0.74
21
3.46
15.0
469
171
35.9
0.78
20
3.49
15.1
474
172
35.1
0.57
16
3.43
14.9
465
169
32.4
0.55
16
3.35
14.5
451
164
28.4
1.00
23
3.28
14.5
437
143
29.2
1.00
21
3.31
14.6
442
144
27.9
1.00
22
3.26
14.4
433
141
25.7
0.97
23
3.18
14.0
420
137
28.9
1.00
23
3.36
14.8
471
152
29.8
1.00
21
3.38
15.0
475
153
28.5
0.94
22
3.33
14.7
466
150
26.3
0.91
22
3.25
14.4
452
146
30.3
0.92
22
3.46
15.3
497
166
31.2
0.96
21
3.49
15.4
502
167
30.4
0.77
19
3.43
15.2
492
164
28.1
0.74
19
3.35
14.8
477
159
67
31.4
0.81
18
3.46
15.3
497
166
32.3
0.75
19
3.58
15.8
518
176
33.3
0.78
19
3.61
15.9
524
178
32.5
0.57
15
3.55
15.7
513
175
30.0
0.55
15
3.46
15.3
498
169
71
33.5
0.60
14
3.58
15.8
518
176
33.9 28.3 28.8 30.2 32.2 26.2 26.7 28.0 29.8
0.69 1.00 0.97 0.88 0.71 1.00 0.98 0.89 0.72
21
26
26
24
21
24
24
23
20
3.24 3.10 3.17 3.27 3.37 3.21 3.27 3.38 3.49
13.8 13.5 13.7 14.2 14.6 14.2 14.5 14.9 15.4
405
384 413
436
455
424
457
482
503
158
134 142
155
165
138
147
161
171
KW = Total system power
AMPS: Unit amps (comp.+ evaporator + condenser fan motors)
36.7
0.71
21
3.32
14.2
417
163
37.8
0.75
20
3.35
14.3
421
164
37.0
0.55
16
3.29
14.1
413
161
34.1
0.53
16
3.21
13.7
401
156
63
29.4
1.00
21
3.36
14.8
471
152
115
COOLING OPERATION
Design Subcooling, 9 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 7+/-2 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65
75
85
95
105
Entering Indoor Wet Bulb Temperature
IDB* Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
MBh 35.1 35.9 38.3 41.0 34.3 35.0 37.4 40.0 33.5
34.2
36.5 39.0 32.6
33.4
35.6
38.1 31.0 31.7 33.9 36.2 28.7
S/T
0.92 0.86 0.70 0.52 0.95 0.89 0.73 0.54 1.00
0.92
0.75 0.56 1.00
0.95
0.77
0.58 1.00 1.00 0.80 0.60 1.00
Delta T 23
22
19
15
23
22
19
15
24
22
19
15
23
22
20
16
22
23
19
15
20
1292
KW
2.56 2.61 2.69 2.77 2.75 2.80 2.89 2.98 2.91
2.97
3.06 3.16 3.05
3.12
3.22
3.32 3.18 3.25 3.35 3.46 3.28
AMPS 10.7 11.0 11.3 11.6 11.5 11.7 12.0 12.4 12.3
12.6
12.9 13.4 13.1
13.3
13.7
14.2 13.8 14.1 14.5 15.0 14.5
HI PR 242
261
275
287
272
292
309
322 309
333
351
366
352
379
400
417
396 426
450
469
437
LO PR 114
121
132
141
121
128
140
149 125
133
145
155
132
140
153
163
138 147
160
171
143
MODEL: GPH1336M41*
COOLING PERFORMANCE DATA
GPH1336M41*
EXPANDED PERFORMANCE DATA
*
75
70
38.1
0.70
19
2.84
12.4
225
105
35.1
0.67
19
2.77
12.2
218
102
39.9
0.83
21
2.88
12.6
229
107
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
41.0
0.74
19
2.94
12.9
247
114
39.4
0.58
16
2.89
12.7
242
111
36.4
0.56
17
2.83
12.4
234
108
40.6
0.61
16
2.91
12.8
244
113
44.4
0.56
16
3.02
13.2
260
124
43.2
0.40
12
2.98
13.0
255
122
39.9
0.39
13
2.91
12.7
248
118
44.5
0.42
12
3.00
13.1
258
123
47.7
0.36
11
3.11
13.6
272
132
-
-
38.9
0.86
21
3.09
13.5
257
113
37.2
0.72
19
3.04
13.3
252
111
34.3
0.70
19
2.97
13.0
244
107
38.3
0.76
18
3.06
13.4
255
112
40.1
0.77
19
3.15
13.8
277
120
38.5
0.60
16
3.10
13.5
271
118
35.6
0.58
17
3.03
13.2
263
114
39.7
0.63
16
3.12
13.7
274
119
43.4
0.58
16
3.24
14.1
292
131
42.2
0.42
13
3.19
13.9
286
129
39.0
0.40
13
3.12
13.6
278
125
43.5
0.44
12
3.22
14.0
289
130
46.6
0.38
11
3.34
14.6
305
140
-
-
38.0
0.88
21
3.27
14.5
292
117
36.3
0.74
19
3.22
14.2
287
115
33.5
0.72
19
3.14
13.9
278
112
37.4
0.78
18
3.24
14.4
290
116
MBh
38.7 39.8 43.1 46.3 37.8 38.9 42.1 45.2 36.9
S/T
0.79 0.71 0.54 0.35 0.82 0.74 0.56 0.36 0.84
Delta T 22
20
16
11
22
20
17
11
22
1300
KW
2.86 2.92 3.00 3.09 3.06 3.12 3.22 3.32 3.24
AMPS 12.5 12.8 13.1 13.5 13.4 13.7 14.0 14.5 14.4
HI PR 227
244
258
269
255
274
289
302
290
LO PR 106
113
123
131
112
119
130
138
116
MBh
35.7 36.8 39.8 42.7 34.9 35.9 38.9 41.7 34.1
S/T
0.77 0.68 0.52 0.33 0.79 0.71 0.54 0.35 0.81
Delta T 22
20
17
11
22
21
17
12
22
1139
KW
2.80 2.85 2.93 3.02 2.99 3.05 3.14 3.24 3.17
AMPS 12.3 12.5 12.8 13.2 13.1 13.3 13.7 14.1 14.0
HI PR 220
237
250
261
247
266
281
293
281
LO PR 103
109
119
127
108
115
126
134
113
Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is ACCA
High and low pressures are measured at the liquid and suction access fittings.
1461
1139
1300
1461
39.2
0.73
18
2.86
12.5
227
106
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
42.4
0.60
16
3.44
15.2
332
136
41.2
0.43
13
3.38
15.0
326
134
38.0
0.41
13
3.31
14.6
316
130
42.4
0.45
12
3.41
15.1
329
135
38.0
41.1
0.75
0.57
20
17
3.31
3.41
14.7
15.1
312
329
124
135
35.1
38.0
0.73
0.55
21
17
3.23
3.33
14.3
14.7
302
319
120
131
(TVA) conditions
39.1
0.79
19
3.34
14.8
315
125
37.6
0.62
16
3.28
14.5
308
122
34.7
0.60
17
3.21
14.2
299
119
38.7
0.65
16
3.31
14.7
312
124
44.1
0.37
11
3.52
15.6
343
144
40.7
0.35
12
3.43
15.2
333
139
45.5
0.39
11
3.55
15.7
347
145
-
-
36.0
0.87
22
3.40
15.2
330
122
33.2
0.84
23
3.32
14.8
320
118
37.1
0.91
21
3.43
15.3
333
123
35.4
0.77
19
3.38
15.1
327
121
32.7
0.74
19
3.30
14.7
317
117
36.5
0.80
18
3.40
15.2
330
122
34.2
0.75
21
3.39
15.2
344
126
37.1
0.78
20
3.47
15.5
355
130
38.2
0.82
20
3.50
15.6
358
131
36.7
0.64
17
3.45
15.4
351
129
33.9
0.62
17
3.37
15.0
341
125
37.8
0.67
16
3.47
15.5
355
130
40.1
0.59
17
3.58
16.0
375
142
37.0
0.57
17
3.50
15.6
364
137
41.3
0.62
16
3.61
16.1
379
143
40.2
0.44
13
3.55
15.8
371
140
37.1
0.43
13
3.47
15.5
360
136
41.4
0.46
12
3.58
16.0
375
142
35.2
0.95
21
3.57
16.2
375
129
33.6
0.80
19
3.51
15.9
367
127
31.0
0.77
19
3.43
15.5
356
123
34.6
0.83
18
3.54
16.0
371
128
36.3
0.85
19
3.64
16.5
403
137
34.9
0.66
16
3.58
16.3
395
135
32.2
0.64
17
3.50
15.9
383
131
35.9
0.70
16
3.61
16.4
399
136
39.3
0.64
16
3.76
17.0
426
150
38.2
0.46
12
3.70
16.7
417
147
35.2
0.44
13
3.61
16.3
405
143
39.3
0.48
12
3.73
16.9
422
148
42.1
0.41
11
3.88
17.6
444
160
-
-
32.6
0.96
20
3.68
17.0
414
134
31.2
0.80
18
3.63
16.7
406
131
28.8
0.77
18
3.54
16.3
394
127
32.1
0.84
17
3.65
16.9
410
132
63
33.6
0.86
18
3.76
17.4
446
142
32.3
0.67
15
3.70
17.1
437
139
29.8
0.65
16
3.61
16.7
424
135
33.3
0.70
15
3.73
17.2
441
141
67
36.4
0.65
15
3.88
17.9
471
155
35.4
0.46
12
3.82
17.6
461
152
32.7
0.45
12
3.73
17.2
447
148
36.4
0.49
11
3.85
17.8
466
154
39.0
0.42
10
4.01
18.5
491
165
-
-
71
43.1 34.2 35.2 38.1 40.9 31.7 32.6 35.3 37.9
0.38 0.90 0.81 0.61 0.39 0.91 0.82 0.62 0.40
12
22
20
16
11
20
19
15
11
3.69 3.54 3.61 3.73 3.84 3.66 3.73 3.85 3.97
16.5 16.0 16.4 16.9 17.4 16.9 17.2 17.8 18.4
391
371
399
422
440
410
441
466
486
151
128
136
149
158
132
141
154
164
39.7 31.6 32.5 35.2 37.8 29.2 30.1 32.6 35.0
0.37 0.87 0.78 0.59 0.38 0.88 0.79 0.60 0.38
12
22
20
17
12
21
19
16
11
3.61 3.45 3.53 3.64 3.75 3.57 3.64 3.76 3.88
16.1 15.7 16.0 16.5 17.0 16.5 16.8 17.3 17.9
379
360
387
409
427
398
428
452
471
146
124
132
144
153
128
136
149
159
KW = Total system power
AMPS: Unit amps (comp.+ evaporator + condenser fan motors)
44.4
0.40
11
3.72
16.6
395
152
-
-
115
COOLING OPERATION
Design Subcooling, 10 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 10 +/-2 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65
75
85
95
105
Entering Indoor Wet Bulb Temperature
IDB* Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
MODEL: GPH1342M41*
COOLING PERFORMANCE DATA
GPH1342M41*
19
20
EXPANDED PERFORMANCE DATA
*
85
40.1
0.91
26
2.90
12.7
232
108
37.0
0.88
26
2.84
12.4
225
105
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1300
1139
37.7
0.85
26
2.89
12.7
242
111
40.9
0.88
25
2.96
13.0
249
115
42.1
0.92
24
2.98
13.1
252
116
39.5
0.77
24
2.98
13.0
255
122
42.8
0.80
24
3.05
13.3
263
125
44.1
0.83
23
3.07
13.4
266
127
42.1
0.62
21
3.07
13.4
266
129
45.6
0.65
21
3.14
13.8
274
134
47.0
0.68
20
3.16
13.9
277
135
36.1
0.91
27
3.04
13.3
252
111
39.1
0.95
26
3.11
13.6
260
114
40.3
0.99
25
3.13
13.7
262
115
36.8
0.88
26
3.10
13.5
271
118
39.9
0.91
26
3.17
13.9
280
121
41.1
0.96
25
3.20
14.0
282
123
38.6
0.79
25
3.19
13.9
286
128
41.8
0.82
24
3.27
14.3
295
132
43.0
0.86
23
3.29
14.4
298
134
41.2
0.64
21
3.29
14.4
299
137
44.6
0.67
21
3.37
14.7
308
141
45.9
0.70
20
3.40
14.8
311
142
35.3
0.94
27
3.22
14.2
287
115
38.2
0.97
26
3.29
14.6
295
119
39.4
1.00
25
3.32
14.7
298
120
36.0
0.90
26
3.28
14.5
308
122
39.0
0.94
26
3.36
14.9
318
126
40.1
0.98
25
3.39
15.0
321
127
37.7
0.81
25
3.38
14.9
326
134
40.8
0.84
24
3.47
15.3
336
138
42.0
0.89
23
3.49
15.4
339
139
Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is AHRI Rating Conditions
High and low pressures are measured at the liquid and suction access fittings.
1461
41.3
0.96
25
2.92
12.8
234
109
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
40.2
0.66
21
3.49
15.4
340
142
43.5
0.69
21
3.57
15.8
350
147
44.8
0.72
20
3.60
15.9
354
148
34.4
0.97
27
3.38
15.1
326
121
37.3
1.00
26
3.46
15.4
336
124
38.4
1.00
24
3.48
15.6
340
126
35.1
0.93
26
3.45
15.4
351
128
38.0
0.97
26
3.53
15.8
362
132
39.1
1.00
25
3.56
15.9
366
134
36.7
0.84
25
3.55
15.8
371
140
39.8
0.87
25
3.64
16.2
382
145
41.0
0.91
24
3.67
16.4
386
146
32.7
1.00
26
3.51
15.9
367
127
35.4
1.00
25
3.59
16.3
379
130
36.5
1.00
23
3.62
16.4
382
132
33.3
0.97
26
3.58
16.3
395
135
36.1
1.00
26
3.67
16.7
407
139
37.2
1.00
23
3.70
16.8
411
140
34.9
0.87
25
3.69
16.7
417
147
37.8
0.91
24
3.79
17.1
430
152
38.9
0.95
23
3.82
17.3
434
153
37.2
0.71
21
3.81
17.3
435
157
40.3
0.73
21
3.91
17.7
449
161
41.5
0.77
20
3.94
17.9
453
163
30.3
1.00
24
3.62
16.7
406
131
32.8
1.00
23
3.71
17.2
418
135
33.8
1.00
21
3.74
17.3
422
136
30.9
0.98
24
3.70
17.1
437
139
33.4
1.00
24
3.79
17.5
450
144
34.4
1.00
22
3.82
17.7
455
145
32.3
0.88
23
3.82
17.6
461
152
35.0
0.91
23
3.91
18.0
475
157
36.1
0.96
22
3.94
18.2
480
158
67
36.3
0.80
18
3.91
18.0
475
157
35.2
0.76
19
3.88
17.9
471
155
32.5
0.74
19
3.79
17.5
456
151
34.5
0.71
20
3.94
18.2
481
162
37.4
0.74
20
4.04
18.7
496
167
38.5
0.78
19
4.07
18.8
501
169
71
38.8
0.60
15
4.04
18.7
496
167
37.6
0.57
15
4.01
18.5
491
165
34.7
0.55
15
3.91
18.0
476
160
KW = Total system power
AMPS: Unit amps (comp.+ evaporator + condenser fan motors)
39.2
0.68
22
3.66
16.4
387
149
42.5
0.71
21
3.75
16.8
399
154
43.7
0.74
20
3.78
16.9
403
156
63
33.9
1.00
21
3.79
17.5
450
144
32.9
0.94
22
3.76
17.4
446
142
30.4
0.90
22
3.67
17.0
432
138
115
COOLING OPERATION
Design Subcooling, 10 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 10 +/-2 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65
75
85
95
105
Entering Indoor Wet Bulb Temperature
IDB* Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
MBh
40.6 41.5 44.3 47.3 39.6 40.5 43.3 46.2 38.7
39.5
42.2 45.1 37.7
38.6
41.2
44.0 35.9 36.6 39.1 41.8 33.2
S/T
0.91 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.97
0.91
0.74 0.55 1.00
0.94
0.76
0.57 1.00 1.00 0.79 0.59 1.00
Delta T 23
22
19
16
24
23
20
16
24
23
20
16
24
23
20
16
23
23
20
16
21
1461
KW
2.90 2.96 3.05 3.14 3.11 3.17 3.27 3.37 3.29
3.36
3.47 3.57 3.46
3.53
3.64
3.75 3.59 3.67 3.79 3.91 3.71
AMPS 12.7 13.0 13.3 13.8 13.6 13.9 14.3 14.7 14.6
14.9
15.3 15.8 15.4
15.8
16.2
16.8 16.3 16.7 17.1 17.7 17.2
HI PR 232
249
263
274
260
280
295
308
295
318
336
350
336
362
382
399
379
407
430
449
418
LO PR 108
115
125
134
114
121
132
141
119
126
138
147
124
132
145
154
130
139
152
161
135
MBh
39.4 40.2 43.0 46.0 38.5 39.3 42.0 44.9 37.6
38.4
41.0 43.8 36.6
37.4
42.8 34.8 35.6 38.0 40.6 32.2
40.0
S/T
0.87 0.82 0.66 0.50 0.90 0.85 0.69 0.51 0.93
0.87
0.71 0.53 0.96
0.90
0.55 0.99 0.93 0.76 0.57 1.00
0.73
Delta T 24
23
20
16
25
24
20
16
25
24
20
16
25
24
16
24
23
20
16
23
21
3.61
80
1300
KW
2.88 2.94 3.02 3.11 3.09 3.15 3.24 3.34 3.27
3.34
3.44 3.55 3.43
3.50
3.72 3.57 3.64 3.76 3.88 3.68
16.1
AMPS 12.6 12.9 13.2 13.7 13.5 13.8 14.1 14.6 14.5
14.8
15.2 15.7 15.3
15.6
16.6 16.2 16.5 17.0 17.6 17.0
HI PR 229
247
260
272
257
277
292
305
293
315
332
347
333
359
395
375
403
426
444
414
379
LO PR 107
114
124
132
113
120
131
140
117
125
136
145
123
131
152
129
137
150
160
134
143
MBh
36.4 37.1 39.7 42.4 35.5 36.3 38.8 41.4 34.7
35.4
37.8 40.5 33.8
34.6
36.9
39.5 32.1 32.8 35.1 37.5 29.8
S/T
0.84 0.79 0.64 0.48 0.87 0.82 0.66 0.50 0.89
0.84
0.68 0.51 0.92
0.86
0.70
0.53 0.96 0.90 0.73 0.55 0.96
Delta T 25
24
21
16
25
24
21
17
25
24
21
17
25
24
21
17
25
24
21
17
23
1139
KW
2.82 2.87 2.96 3.04 3.02 3.08 3.17 3.27 3.19
3.26
3.36 3.46 3.35
3.42
3.52
3.64 3.48 3.55 3.67 3.78 3.60
AMPS 12.3 12.6 12.9 13.3 13.2 13.4 13.8 14.3 14.1
14.4
14.8 15.3 15.0
15.3
15.7
16.2 15.8 16.1 16.6 17.1 16.6
HI PR 222
239
253
264
249
268
284
296
284
305
322
336
323
348
367
383
364
391
413
431
402
LO PR 104
110
120
128
110
117
127
135
114
121
132
141
120
127
139
148
125
133
146
155
130
MODEL: GPH1342M41*
COOLING PERFORMANCE DATA
GPH1342M41*
EXPANDED PERFORMANCE DATA
*
75
70
44.2
0.76
18
3.26
13.6
238
108
40.8
0.73
18
3.19
13.3
231
104
46.3
0.90
20
3.31
13.8
243
110
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
47.7
0.81
18
3.38
14.1
261
117
45.9
0.63
16
3.33
13.8
256
114
42.3
0.61
16
3.25
13.5
249
111
47.2
0.66
15
3.36
14.0
259
116
51.6
0.61
15
3.49
14.5
276
127
50.2
0.44
12
3.43
14.2
271
125
46.4
0.42
12
3.35
13.9
262
121
51.7
0.46
11
3.46
14.4
273
126
55.4
0.39
10
3.60
14.9
288
136
-
-
45.3
0.94
20
3.56
14.7
273
116
43.2
0.79
18
3.51
14.5
267
114
39.9
0.76
18
3.42
14.2
259
110
44.5
0.82
17
3.53
14.6
270
115
46.6
0.84
19
3.64
15.1
293
123
44.8
0.66
16
3.58
14.8
288
121
41.3
0.63
16
3.50
14.5
279
117
46.1
0.69
15
3.61
14.9
290
122
50.4
0.63
15
3.75
15.5
310
135
49.1
0.45
12
3.69
15.2
304
132
45.3
0.44
12
3.60
14.9
294
128
50.5
0.48
11
3.72
15.4
307
133
54.1
0.41
11
3.87
16.0
323
143
-
-
44.2
0.96
20
3.78
15.9
310
121
42.2
0.81
18
3.72
15.6
304
118
38.9
0.78
18
3.63
15.2
295
115
43.4
0.85
17
3.75
15.7
307
119
MBh
45.0 46.3 50.1 53.8 43.9 45.2 49.0 52.6 42.9
S/T
0.86 0.77 0.58 0.38 0.89 0.80 0.60 0.39 0.92
Delta T 21
19
16
11
21
19
16
11
21
1720
KW
3.29 3.36 3.46 3.57 3.53 3.61 3.72 3.84 3.75
AMPS 13.7 14.0 14.4 14.8 14.6 14.9 15.4 15.9 15.7
HI PR 241
259
273
285
270
290
307
320
307
LO PR 109
116
126
134
115
122
133
142
119
MBh
41.5 42.8 46.3 49.7 40.6 41.8 45.2 48.5 39.6
S/T
0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.38 0.88
Delta T 21
19
16
11
21
20
16
11
21
1507
KW
3.21 3.28 3.38 3.48 3.45 3.52 3.63 3.75 3.66
AMPS 13.4 13.6 14.0 14.5 14.3 14.6 15.0 15.5 15.4
HI PR 233
251
265
277
262
282
298
310
298
LO PR 105
112
122
130
111
118
129
138
116
Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is ACCA
High and low pressures are measured at the liquid and suction access fittings.
1933
1507
1720
1933
45.6
0.80
17
3.29
13.7
240
109
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
49.2
0.65
15
3.99
16.7
352
140
47.9
0.47
12
3.92
16.4
345
137
44.2
0.45
12
3.83
16.0
335
133
49.3
0.49
11
3.95
16.5
349
139
44.2
47.8
0.82
0.62
19
16
3.83
3.95
16.1
16.6
330
349
127
139
40.8
44.1
0.79
0.60
20
16
3.74
3.86
15.7
16.1
320
338
123
134
(TVA) conditions
45.5
0.86
19
3.86
16.2
334
128
43.7
0.67
16
3.80
15.9
327
126
40.4
0.65
16
3.71
15.6
317
122
45.0
0.71
15
3.83
16.1
330
127
51.3
0.40
11
4.08
17.1
364
148
47.4
0.38
11
3.98
16.7
353
143
52.8
0.42
11
4.12
17.2
367
149
-
-
41.9
0.95
21
3.94
16.7
350
125
38.6
0.91
21
3.85
16.3
339
122
43.1
0.99
20
3.98
16.8
353
127
41.2
0.83
18
3.91
16.6
346
124
38.0
0.80
19
3.82
16.2
336
120
42.4
0.87
18
3.94
16.7
350
125
39.8
0.82
20
3.93
16.6
365
129
43.1
0.85
19
4.03
17.1
376
133
44.4
0.89
19
4.06
17.2
380
135
42.7
0.69
16
4.00
16.9
372
132
39.4
0.67
16
3.90
16.5
361
128
43.9
0.73
15
4.03
17.1
376
133
46.6
0.64
16
4.16
17.6
397
146
43.0
0.62
16
4.06
17.1
385
141
48.0
0.67
15
4.19
17.7
401
147
46.7
0.48
12
4.12
17.4
393
144
43.1
0.46
12
4.02
17.0
381
140
48.1
0.50
12
4.16
17.6
397
146
41.0
1.00
19
4.14
17.8
397
133
39.1
0.86
18
4.07
17.5
389
130
36.1
0.83
18
3.97
17.1
378
126
40.3
0.91
17
4.11
17.6
393
131
42.2
0.92
18
4.23
18.2
427
141
40.5
0.72
16
4.16
17.9
419
138
37.4
0.70
16
4.06
17.4
406
134
41.7
0.76
15
4.20
18.0
423
140
45.6
0.70
15
4.37
18.7
451
154
44.4
0.50
12
4.30
18.4
442
151
41.0
0.48
12
4.19
18.0
429
146
45.7
0.52
11
4.33
18.6
447
153
49.0
0.45
10
4.51
19.4
471
164
-
-
37.9
1.00
18
4.28
18.8
439
137
36.2
0.87
17
4.21
18.4
430
135
33.4
0.84
17
4.11
18.0
417
130
37.3
0.91
16
4.25
18.6
434
136
63
39.1
0.93
17
4.38
19.2
472
146
37.5
0.73
15
4.30
18.8
463
143
34.6
0.70
15
4.20
18.4
449
139
38.7
0.76
14
4.34
19.0
468
145
67
42.3
0.70
14
4.52
19.8
499
159
41.1
0.50
11
4.44
19.4
489
156
38.0
0.49
11
4.33
18.9
474
152
42.4
0.53
11
4.48
19.6
494
158
45.4
0.45
10
4.67
20.4
520
170
-
-
71
50.1 39.8 40.9 44.3 47.6 36.8 37.9 41.0 44.0
0.41 0.98 0.88 0.66 0.43 0.99 0.89 0.67 0.43
11
21
19
16
11
19
18
15
10
4.29 4.11 4.20 4.33 4.48 4.25 4.34 4.48 4.63
18.2 17.7 18.0 18.6 19.2 18.6 19.0 19.6 20.3
414
393
423
447
466
435
468
494
515
155
131
140
153
162
136
145
158
168
46.2 36.7 37.8 40.9 43.9 34.0 35.0 37.9 40.7
0.40 0.95 0.85 0.64 0.41 0.95 0.85 0.65 0.42
11
21
20
16
11
20
18
15
10
4.19 4.01 4.09 4.22 4.36 4.14 4.23 4.37 4.52
17.7 17.2 17.6 18.1 18.7 18.1 18.5 19.1 19.8
402
382
411
434
452
422
454
479
500
150
127
136
148
158
132
140
153
163
KW = Total system power
AMPS: Unit amps (comp.+ evaporator + condenser fan motors)
51.6
0.43
11
4.33
18.3
419
157
-
-
115
COOLING OPERATION
Design Subcooling, 12 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 9 +/-2 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65
75
85
95
105
Entering Indoor Wet Bulb Temperature
IDB* Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
MODEL: GPH1348M41*
COOLING PERFORMANCE DATA
GPH1348M41*
21
22
EXPANDED PERFORMANCE DATA
*
85
54.7
0.73
19
3.65
15.2
294
139
46.9
1.00
22
3.62
15.0
278
118
47.8
1.00
23
3.70
15.3
299
126
50.0
0.94
22
3.81
15.7
316
137
53.4
0.76
19
3.93
16.3
330
146
45.8
1.00
22
3.84
16.1
316
123
46.6
1.00
22
3.93
16.5
340
131
48.8
0.96
22
4.05
17.0
359
143
43.3
1.00
23
4.01
17.0
357
128
40.0
1.00
24
3.91
16.6
346
124
51.2
0.91
22
3.54
14.7
282
130
MBh
46.6 47.5 49.7 53.1 45.5 46.4 48.6 51.8 44.4
45.3
47.4 50.6
S/T
0.99 0.96 0.86 0.70 1.00 0.99 0.89 0.73 1.00
1.00
0.92 0.74
Delta T 25
24
23
20
24
25
23
20
24
24
23
20
1720
KW
3.34 3.41 3.51 3.62 3.59 3.67 3.78 3.90 3.81
3.89
4.02 4.15
AMPS 13.9 14.2 14.6 15.1 14.9 15.2 15.6 16.1 16.0
16.3
16.8 17.4
HI PR 245
264 279
291
275
296
313
326 313
337
356
371
LO PR 111
118 129
137
117
125
136
145 122
130
141
151
MBh
43.0 43.8 45.9 49.0 42.0 42.8 44.8 47.8 41.0
41.8
43.8 46.7
S/T
0.96 0.92 0.83 0.68 0.99 0.96 0.86 0.70 1.00
0.98
0.88 0.72
Delta T 25
25
23
20
25
25
24
20
25
25
24
20
1507
KW
3.26 3.33 3.43 3.54 3.51 3.58 3.69 3.81 3.72
3.80
3.92 4.05
AMPS 13.6 13.8 14.2 14.7 14.5 14.8 15.2 15.7 15.6
15.9
16.4 17.0
HI PR 238
256 270
282
267
287
304
317 304
327
345
360
LO PR 108
114 125
133
114
121
132
141 118
126
137
146
Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is AHRI Rating Conditions
High and low pressures are measured at the liquid and suction access fittings.
1933
48.9
1.00
23
3.44
14.3
267
119
44.6
1.00
21
4.04
17.1
360
129
48.0
1.00
23
3.37
14.0
248
112
52.1
0.78
19
4.18
17.5
375
152
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
44.2
1.00
24
4.10
17.3
384
136
40.8
1.00
25
3.99
16.9
372
132
45.5
1.00
22
4.13
17.5
388
137
46.3
0.95
23
4.23
17.9
405
149
42.7
0.91
24
4.12
17.4
393
144
47.7
0.99
23
4.26
18.0
409
150
42.4
1.00
20
4.21
18.1
405
135
43.2
1.00
21
4.30
18.5
436
144
45.3
1.00
22
4.44
19.1
461
157
48.3
0.84
19
4.59
19.7
480
167
39.3
1.00
19
4.35
19.1
448
140
40.0
1.00
19
4.45
19.5
482
149
41.9
1.00
20
4.60
20.1
509
163
67
42.1
0.87
17
4.56
19.9
504
161
40.9
0.83
18
4.52
19.8
499
159
37.8
0.80
18
4.41
19.3
484
155
44.7
0.84
18
4.75
20.8
531
173
71
45.1
0.65
14
4.71
20.6
525
171
43.7
0.62
14
4.67
20.4
520
170
40.4
0.60
15
4.55
19.9
505
165
49.4 41.2 42.0 44.0 46.9 38.1 38.9 40.7 43.4
0.77 1.00 1.00 0.98 0.80 1.00 1.00 0.99 0.80
20
22
22
23
20
20
21
22
19
4.37 4.17 4.27 4.40 4.55 4.32 4.41 4.56 4.71
18.5 17.9 18.3 18.9 19.6 18.9 19.3 19.9 20.6
423
401 432
456 476
443
477
504
525
158
134 143
156 166
139
147
161
171
45.6 38.0 38.7 40.6 43.3 35.2 35.9 37.6 40.1
0.74 1.00 1.00 0.95 0.77 1.00 1.00 0.96 0.78
21
23
24
23
20
21
22
22
19
4.26 4.07 4.16 4.30 4.44 4.21 4.30 4.44 4.59
18.0 17.5 17.9 18.4 19.1 18.4 18.8 19.4 20.1
410
389 419
442 461
430
463
489
510
153
130 138
151 161
134
143
156
166
KW = Total system power
AMPS: Unit amps (comp.+ evaporator + condenser fan motors)
50.8
0.81
19
4.40
18.6
427
160
63
39.5
1.00
19
4.41
19.3
477
147
38.3
1.00
20
4.38
19.2
472
146
35.4
0.98
21
4.27
18.7
458
142
115
COOLING OPERATION
Design Subcooling, 12 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 9 +/-2 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65
75
85
95
105
Entering Indoor Wet Bulb Temperature
IDB* Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
MBh
47.2 48.2 51.5 55.0 46.1 47.1 50.3 53.8 45.0
46.0
49.1 52.5 43.9
44.8
47.9
51.2 41.7 42.6 45.5 48.6 38.6
S/T
1.00 0.93 0.76 0.57 1.00 0.96 0.78 0.59 1.00
1.00
0.80 0.60 1.00
1.00
0.83
0.62 1.00 1.00 0.86 0.64 1.00
Delta T 22
21
19
15
22
22
19
15
21
22
19
15
21
21
19
15
20
20
19
15
18
1933
KW
3.34 3.41 3.51 3.62 3.59 3.67 3.78 3.90 3.81
3.89
4.02 4.15 4.01
4.10
4.23
4.37 4.17 4.27 4.40 4.55 4.32
AMPS 13.9 14.2 14.6 15.1 14.9 15.2 15.6 16.1 16.0
16.3
16.8 17.4 17.0
17.3
17.9
18.5 17.9 18.3 18.9 19.6 18.9
HI PR 245
264 279
291
275
296
313
326 313
337
356
371
357
384
405
423
401 432
456 476
443
LO PR 111
118 129
137
117
125
136
145 122
130
141
151
128
136
149
158
134 143
156 166
139
MBh
45.8 46.8 50.0 53.4 44.7 45.7 48.8 52.2 43.7
44.6
47.7 51.0 42.6
43.5
49.7 40.5 41.3 44.2 47.2 37.5
46.5
S/T
0.95 0.89 0.72 0.54 0.98 0.92 0.75 0.56 1.00
0.94
0.77 0.57 1.00
0.97
0.59 1.00 1.00 0.82 0.61 1.00
0.79
Delta T 23
22
19
15
23
22
20
16
23
22
20
16
23
23
16
22
22
19
16
20
20
4.19
80
1720
KW
3.31 3.38 3.49 3.60 3.56 3.64 3.75 3.87 3.78
3.86
3.99 4.12 3.98
4.06
4.33 4.14 4.23 4.37 4.51 4.28
17.7
AMPS 13.8 14.1 14.5 14.9 14.7 15.1 15.5 16.0 15.9
16.2
16.7 17.2 16.8
17.2
18.3 17.8 18.2 18.7 19.4 18.8
HI PR 243
261 276
288
273
293
310
323 310
334
352
367
353
380
419
397 428
451 471
439
401
LO PR 110
117 127
136
116
123
135
143 121
128
140
149
127
135
157
133 141
154 164
137
147
MBh
42.3 43.2 46.1 49.3 41.3 42.2 45.1 48.2 40.3
41.2
44.0 47.0 39.3
40.2
42.9
45.9 37.3 38.2 40.8 43.6 34.6
S/T
0.91 0.86 0.70 0.52 0.94 0.89 0.72 0.54 0.97
0.91
0.74 0.55 1.00
0.94
0.76
0.57 1.04 0.97 0.79 0.59 1.05
Delta T 24
23
20
16
24
23
20
16
24
23
20
16
24
23
20
16
24
23
20
16
22
1507
KW
3.24 3.30 3.40 3.51 3.48 3.55 3.66 3.78 3.69
3.77
3.89 4.01 3.88
3.96
4.09
4.22 4.04 4.13 4.26 4.40 4.18
AMPS 13.5 13.7 14.1 14.6 14.4 14.7 15.1 15.6 15.5
15.8
16.3 16.8 16.4
16.8
17.3
17.9 17.4 17.7 18.3 18.9 18.3
HI PR 236
254 268
279
264
285
301
313 301
324
342
356
343
369
389
406
385 415
438 457
426
LO PR 106
113 124
132
112
120
131
139 117
124
136
145
123
131
143
152
129 137
149 159
133
MODEL: GPH1348M41*
COOLING PERFORMANCE DATA
GPH1348M41*
EXPANDED PERFORMANCE DATA
*
75
70
53.3
0.70
19
4.01
16.9
239
105
49.2
0.67
19
3.92
16.5
232
101
55.8
0.83
21
4.07
17.1
244
107
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1800
1577
2023
57.5
0.74
19
4.15
17.5
262
113
51.0
0.56
17
4.00
16.8
249
108
55.2
0.58
16
4.09
17.2
257
111
56.9
0.61
16
4.12
17.3
260
112
62.2
0.56
16
4.28
18.0
277
124
55.8
0.39
13
4.12
17.3
263
118
60.5
0.40
12
4.21
17.7
272
121
62.3
0.42
12
4.25
17.8
274
123
66.7
0.36
11
4.41
18.6
289
132
-
-
-
54.5
0.86
21
4.37
18.3
274
113
48.0
0.70
20
4.20
17.6
260
107
52.0
0.72
19
4.30
18.0
268
110
53.6
0.76
18
4.34
18.2
271
112
56.1
0.77
20
4.46
18.7
294
120
49.8
0.58
17
4.29
18.0
280
114
53.9
0.60
17
4.39
18.4
289
118
55.6
0.63
16
4.43
18.6
291
119
60.7
0.58
16
4.60
19.3
311
131
54.5
0.40
13
4.42
18.5
296
124
59.1
0.42
13
4.53
19.0
305
128
60.9
0.44
12
4.56
19.1
308
130
65.2
0.38
11
4.75
19.9
324
139
-
-
-
53.2
0.88
21
4.64
19.7
311
117
46.9
0.72
20
4.46
18.9
296
111
50.8
0.74
19
4.56
19.4
305
115
52.3
0.78
19
4.60
19.6
308
116
MBh
54.2 55.8 60.4 64.8 52.9 54.5 59.0 63.3 51.7
S/T
0.79 0.71 0.54 0.35 0.82 0.74 0.56 0.36 0.84
Delta T 22
20
17
11
22
20
17
12
22
1800
KW
4.04 4.12 4.25 4.38 4.34 4.43 4.56 4.71 4.60
AMPS 17.0 17.3 17.8 18.4 18.2 18.6 19.1 19.7 19.6
HI PR 241
260
274
286
271
291
308
321
308
LO PR 106
112
123
131
112
119
130
138
116
MBh
50.0 51.5 55.7 59.8 48.8 50.3 54.4 58.4 47.7
S/T
0.77 0.68 0.52 0.33 0.79 0.71 0.54 0.35 0.81
Delta T 22
21
17
12
23
21
17
12
23
1577
KW
3.95 4.03 4.15 4.28 4.24 4.32 4.46 4.60 4.49
AMPS 16.6 16.9 17.4 18.0 17.8 18.1 18.7 19.3 19.1
HI PR 234
252
266
277
263
283
299
311
299
LO PR 102
109
119
127
108
115
126
134
112
Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is ACCA
High and low pressures are measured at the liquid and suction access fittings.
2023
54.9
0.73
18
4.04
17.0
241
106
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
59.3
0.60
16
4.88
20.8
354
136
53.2
0.41
13
4.69
19.9
336
129
57.7
0.43
13
4.81
20.4
346
133
59.4
0.45
12
4.84
20.6
350
135
53.2
57.6
0.75
0.57
20
17
4.70
4.85
20.0
20.6
331
350
123
135
49.1
53.1
0.73
0.55
21
17
4.59
4.73
19.5
20.1
322
340
120
131
(TVA) conditions
54.8
0.79
20
4.74
20.2
335
125
48.6
0.60
17
4.55
19.3
318
118
52.7
0.62
17
4.66
19.8
328
122
54.2
0.65
16
4.70
20.0
331
123
61.8
0.37
12
5.00
21.3
365
143
57.0
0.35
12
4.88
20.8
354
139
63.6
0.39
11
5.04
21.5
369
145
-
-
-
50.4
0.87
22
4.83
20.8
351
122
46.5
0.84
23
4.72
20.3
340
118
51.9
0.91
22
4.87
20.9
354
123
45.7
0.74
20
4.68
20.1
337
117
49.6
0.77
19
4.79
20.6
347
121
51.0
0.80
19
4.83
20.8
351
122
47.9
0.75
21
4.82
20.7
366
126
51.9
0.78
21
4.94
21.2
378
130
53.4
0.82
20
4.98
21.4
381
131
47.4
0.62
17
4.78
20.5
363
124
51.4
0.64
17
4.90
21.0
374
128
52.9
0.67
16
4.94
21.2
377
130
56.2
0.59
17
5.09
21.9
399
141
51.8
0.57
17
4.97
21.3
387
137
57.9
0.62
16
5.13
22.0
403
143
51.9
0.43
13
4.93
21.1
383
136
56.3
0.44
13
5.05
21.7
395
140
58.0
0.46
12
5.09
21.9
399
141
49.3
0.95
21
5.07
22.1
399
129
43.5
0.77
19
4.87
21.2
379
123
47.1
0.80
19
4.99
21.8
391
126
48.5
0.83
18
5.03
22.0
395
128
50.8
0.85
20
5.18
22.6
429
137
45.0
0.64
17
4.97
21.7
408
130
48.8
0.66
17
5.10
22.3
420
134
50.3
0.70
16
5.14
22.4
425
136
55.0
0.64
16
5.35
23.3
453
150
49.3
0.44
13
5.13
22.4
431
142
53.5
0.46
13
5.26
22.9
444
147
55.1
0.48
12
5.30
23.1
448
148
59.0
0.41
11
5.52
24.1
472
159
-
-
-
45.7
0.96
20
5.24
23.3
440
133
40.3
0.77
18
5.03
22.4
419
127
43.6
0.80
18
5.16
22.9
432
131
44.9
0.84
17
5.20
23.1
436
132
63
47.0
0.85
18
5.36
23.9
474
142
41.7
0.65
16
5.14
22.9
451
135
45.2
0.67
15
5.27
23.5
465
139
46.6
0.70
15
5.31
23.7
469
140
67
50.9
0.65
15
5.53
24.6
501
155
45.7
0.45
12
5.31
23.6
476
147
49.5
0.46
12
5.44
24.2
491
152
51.0
0.49
11
5.48
24.4
495
153
54.6
0.42
10
5.71
25.5
522
165
-
-
-
71
60.3 47.9 49.3 53.4 57.3 44.4 45.7 49.4 53.0
0.38 0.90 0.81 0.61 0.39 0.91 0.82 0.62 0.40
12
22
20
17
12
21
19
16
11
5.26 5.03 5.14 5.30 5.48 5.20 5.31 5.49 5.67
22.6 22.0 22.5 23.1 23.9 23.1 23.7 24.4 25.2
416
395
425
449
468
436
469
496
517
151
128
136
148
158
132
140
153
163
55.6 44.2 45.5 49.3 52.9 40.9 42.1 45.6 49.0
0.37 0.87 0.78 0.59 0.38 0.88 0.79 0.59 0.38
12
22
21
17
12
21
19
16
11
5.13 4.91 5.01 5.17 5.34 5.07 5.18 5.35 5.53
22.0 21.4 21.9 22.6 23.3 22.6 23.1 23.8 24.6
403
383
412
435
454
423
455
481
501
146
124
132
144
153
128
136
149
158
KW = Total system power
AMPS: Unit amps (comp.+ evaporator + condenser fan motors)
62.1
0.40
11
5.30
22.8
420
152
-
-
-
115
COOLING OPERATION
Design Subcooling, 9 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 7 +/-2 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65
75
85
95
105
Entering Indoor Wet Bulb Temperature
IDB* Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
MODEL: GPH1360M41*
COOLING PERFORMANCE DATA
GPH1360M41*
23
24
EXPANDED PERFORMANCE DATA
*
85
57.8
0.96
25
4.13
17.4
249
109
56.1
0.91
26
4.10
17.3
246
108
51.8
0.88
27
4.01
16.9
239
105
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1577
2023
1800
1577
52.8
0.85
26
4.09
17.2
257
111
57.2
0.88
26
4.19
17.6
265
115
58.9
0.92
25
4.22
17.8
268
116
52.0
0.79
24
4.06
17.1
255
110
55.3
0.77
25
4.21
17.7
271
121
59.9
0.79
24
4.31
18.1
280
125
61.7
0.83
23
4.35
18.3
283
126
55.6
0.64
21
4.18
17.6
269
120
59.0
0.62
21
4.34
18.3
283
129
63.9
0.64
21
4.45
18.7
292
133
65.8
0.68
20
4.48
18.9
295
135
59.4
0.48
17
4.31
18.1
280
128
50.6
0.91
27
4.30
18.0
268
110
54.8
0.95
26
4.41
18.5
276
114
56.4
0.99
25
4.44
18.6
279
115
49.7
0.87
25
4.27
17.9
265
109
51.6
0.88
26
4.39
18.4
288
117
55.9
0.91
26
4.50
18.9
297
121
57.5
0.96
25
4.53
19.0
300
122
50.8
0.82
24
4.36
18.3
286
116
54.0
0.79
25
4.53
19.0
305
128
58.5
0.82
25
4.64
19.4
314
132
60.3
0.86
24
4.67
19.6
317
134
54.3
0.66
21
4.49
18.8
302
127
57.6
0.64
22
4.67
19.6
318
137
62.4
0.67
21
4.78
20.1
327
141
64.3
0.70
20
4.82
20.2
331
142
58.0
0.50
17
4.63
19.4
315
135
49.4
0.94
27
4.56
19.4
305
115
53.5
0.97
27
4.67
19.9
314
118
55.1
1.00
25
4.71
20.1
317
119
48.5
0.89
25
4.53
19.3
302
114
50.3
0.90
26
4.66
19.8
328
122
54.5
0.94
26
4.77
20.3
338
126
56.2
0.98
25
4.81
20.5
342
127
49.6
0.84
24
4.62
19.7
325
121
52.7
0.81
25
4.81
20.4
346
133
57.1
0.84
25
4.92
20.9
357
137
58.8
0.89
24
4.96
21.1
361
139
53.0
0.68
21
4.77
20.2
343
132
Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is AHRI Rating Conditions
High and low pressures are measured at the liquid and suction access fittings.
50.9
0.84
25
3.98
16.7
236
103
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
56.2
0.66
22
4.96
21.1
361
142
60.9
0.69
21
5.08
21.6
372
146
62.8
0.72
20
5.12
21.8
376
148
56.6
0.51
17
4.92
20.9
358
141
48.2
0.97
27
4.79
20.6
347
121
52.2
1.00
27
4.91
21.1
358
124
53.8
1.00
24
4.95
21.3
361
126
47.3
0.92
25
4.75
20.4
344
119
49.1
0.93
27
4.89
21.0
374
128
53.2
0.97
26
5.02
21.6
385
132
54.8
1.00
25
5.06
21.8
389
134
48.4
0.86
24
4.86
20.9
370
127
51.4
0.84
25
5.05
21.7
395
140
55.7
0.87
25
5.18
22.2
407
144
57.4
0.91
24
5.22
22.4
411
146
51.7
0.70
21
5.01
21.5
391
139
45.8
1.00
27
4.99
21.8
391
126
49.6
1.00
25
5.11
22.3
403
130
51.1
1.00
23
5.15
22.5
407
132
45.0
0.96
25
4.95
21.6
387
125
46.7
0.97
26
5.10
22.3
420
134
50.5
1.00
26
5.22
22.8
433
139
52.1
1.00
24
5.27
23.0
438
140
46.0
0.90
24
5.05
22.1
416
133
48.9
0.87
25
5.26
22.9
444
147
52.9
0.90
24
5.39
23.5
458
151
54.5
0.95
24
5.44
23.7
462
153
49.1
0.73
21
5.22
22.7
439
145
52.1
0.71
22
5.43
23.7
463
156
56.5
0.73
21
5.57
24.3
477
161
58.2
0.77
20
5.61
24.5
482
163
52.5
0.55
17
5.39
23.5
458
155
42.4
1.00
25
5.16
22.9
432
131
45.9
1.00
23
5.29
23.5
445
135
47.3
1.00
21
5.33
23.7
449
136
41.7
0.96
23
5.12
22.8
427
129
43.2
0.98
25
5.27
23.5
464
139
46.8
1.00
24
5.40
24.1
479
143
48.2
1.00
22
5.45
24.3
484
145
42.6
0.90
22
5.23
23.3
460
138
45.3
0.88
23
5.44
24.2
490
152
49.0
0.91
23
5.58
24.8
506
156
50.5
0.96
22
5.62
25.0
511
158
45.5
0.74
20
5.39
24.0
486
150
67
50.8
0.80
18
5.58
24.8
506
156
49.3
0.76
19
5.53
24.6
501
155
48.3
0.71
20
5.62
25.0
511
162
52.3
0.74
20
5.76
25.7
527
167
53.9
0.78
19
5.81
25.9
533
168
48.6
0.55
16
5.57
24.8
506
160
71
54.3
0.60
15
5.76
25.7
527
167
52.7
0.57
15
5.71
25.5
522
165
KW = Total system power
AMPS: Unit amps (comp.+ evaporator + condenser fan motors)
54.9
0.68
22
5.21
22.4
411
149
59.4
0.71
21
5.35
23.0
424
154
61.2
0.74
21
5.39
23.2
428
155
55.3
0.53
17
5.17
22.2
407
148
63
47.5
1.00
22
5.40
24.1
479
143
46.1
0.94
22
5.36
23.9
474
142
115
COOLING OPERATION
Design Subcooling, 9 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 7 +/-2 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65
75
85
95
105
Entering Indoor Wet Bulb Temperature
IDB* Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
MBh
56.8 58.0 62.0 66.3 55.5 56.7 60.6 64.7 54.2
55.3
59.1 63.2 52.8
54.0
57.7
61.7 50.2 51.3 54.8 58.6 46.5
S/T
0.91 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.97
0.91
0.74 0.55 1.00
0.94
0.76
0.57 1.00 1.00 0.79 0.59 1.00
Delta T 24
23
20
16
24
23
20
16
24
23
20
16
24
23
20
16
23
23
20
16
21
2023
KW
4.10 4.19 4.31 4.45 4.41 4.50 4.64 4.78 4.67
4.77
4.92 5.08 4.91
5.02
5.18
5.35 5.11 5.22 5.39 5.57 5.29
AMPS 17.3 17.6 18.1 18.7 18.5 18.9 19.4 20.1 19.9
20.3
20.9 21.6 21.1
21.6
22.2
23.0 22.3 22.8 23.5 24.3 23.5
HI PR 246
265
280
292
276
297
314
327
314
338
357
372
358
385
407
424
403
433
458
477
445
LO PR 108
115
125
133
114
121
132
141
118
126
137
146
124
132
144
154
130
139
151
161
135
MBh
55.1 56.3 60.2 64.4 53.9 55.0 58.8 62.9 52.6
53.7
57.4 61.4 51.3
52.4
59.9 48.7 49.8 53.2 56.9 45.1
56.0
S/T
0.87 0.82 0.66 0.50 0.90 0.85 0.69 0.51 0.93
0.87
0.71 0.53 0.96
0.90
0.54 0.99 0.93 0.76 0.57 1.00
0.73
Delta T 25
24
20
16
25
24
21
17
25
24
21
17
25
24
17
25
24
21
16
23
21
5.14
80
1800
KW
4.07 4.15 4.28 4.41 4.37 4.46 4.60 4.75 4.64
4.74
4.88 5.04 4.87
4.98
5.30 5.07 5.18 5.35 5.52 5.24
22.0
AMPS 17.1 17.5 18.0 18.6 18.3 18.7 19.3 19.9 19.7
20.2
20.8 21.5 20.9
21.4
22.8 22.2 22.6 23.3 24.1 23.3
HI PR 244
262
277
289
274
294
311
324
311
335
354
369
354
381
420
399
429
453
473
440
403
LO PR 107
113
124
132
113
120
131
139
117
125
136
145
123
131
152
129
137
150
159
133
143
MODEL: GPH1360M41*
COOLING PERFORMANCE DATA
GPH1360M41*
HEATING PERFORMANCE DATA
GPH13[24-42]M41*
EXPANDED PERFORMANCE DATA
MODEL: GPH1324M41*
HEATING OPERATION
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
MBh
28.9
27.4
25.8
24.1
23.0
22.3
20.7
19.1
16.7
15.4
14.2
Delta T
32.4
30.7
28.9
27.0
25.8
25.0
23.2
21.4
18.8
17.3
15.9
KW
2.14
2.10
2.06
2.01
1.99
1.97
1.94
1.89
2.32
2.26
2.21
AMPS
10.4
9.8
9.2
8.8
8.5
8.4
8.0
7.7
7.4
7.1
6.9
COP
3.96
3.82
3.67
3.50
3.38
3.30
3.13
2.95
2.11
1.99
1.88
EER
13.5
13.1
12.5
12.0
11.5
11.3
10.7
10.1
7.2
6.8
6.4
HI PR
379
364
350
334
326
320
308
295
283
270
260
LO PR
135
126
118
108
102
98
90
80
73
65
57
Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.
17
13.4
15.1
2.18
6.7
1.80
6.2
253
53
15
12.9
14.5
2.16
6.7
1.75
6.0
249
51
10
11.6
13.0
2.10
6.4
1.61
5.5
239
43
MODEL: GPH1330M41*
MBh
Delta T
KW
AMPS
COP
EER
HI PR
LO PR
65
36.2
31.9
2.74
13.6
3.87
13.2
375
131
60
34.3
30.2
2.68
12.7
3.74
12.8
359
122
5
10.3
11.5
2.05
6.1
1.47
5.0
230
37
0
9.0
10.1
2.00
5.8
1.31
4.5
221
31
-5
7.6
8.6
1.95
5.5
1.15
3.9
213
27
-10
6.3
7.0
1.89
5.1
0.97
3.3
205
22
HEATING OPERATION
55
32.3
28.4
2.63
12.0
3.59
12.3
346
114
50
30.2
26.6
2.58
11.4
3.42
11.7
330
105
47
28.8
25.4
2.55
11.1
3.30
11.3
323
99
45
27.9
24.6
2.53
10.9
3.23
11.0
316
95
Outdoor Ambient Temperature
40
35
30
25
25.9
23.9
21.2
19.6
22.9
21.1
18.7
17.3
2.48
2.43
2.29
2.24
10.4
9.9
9.6
9.2
3.06
2.88
2.71
2.55
10.5
9.8
9.2
8.7
304
292
280
267
88
78
70
63
20
18.0
15.9
2.19
8.9
2.40
8.2
256
55
17
17.0
15.0
2.17
8.7
2.30
7.9
250
51
15
16.4
14.4
2.15
8.6
2.23
7.6
246
49
10
14.7
13.0
2.10
8.2
2.05
7.0
236
42
5
13.0
11.5
2.05
7.8
1.86
6.4
227
36
0
11.4
10.0
2.00
7.5
1.66
5.7
218
30
-5
9.7
8.6
1.95
7.0
1.46
5.0
210
27
-10
7.9
7.0
1.90
6.5
1.22
4.2
203
21
Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.
MODEL: GPH1336M41*
HEATING OPERATION
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
MBh
43.0
40.7
38.3
35.8
34.2
33.1
30.8
28.4
24.4
22.6
20.8
Delta T
34.6
32.8
30.8
28.8
27.5
26.7
24.8
22.9
19.7
18.2
16.7
KW
3.10
3.04
2.98
2.92
2.89
2.86
2.81
2.75
2.36
2.31
2.26
AMPS
15.4
14.4
13.6
12.9
12.5
12.3
11.7
11.1
10.7
10.3
9.9
COP
4.06
3.92
3.76
3.58
3.46
3.39
3.21
3.02
3.03
2.86
2.69
EER
13.9
13.4
12.8
12.2
11.8
11.6
11.0
10.3
10.4
9.8
9.2
HI PR
403
386
371
355
347
340
327
314
300
287
276
LO PR
137
127
119
109
103
99
91
81
73
66
58
Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.
17
19.6
15.8
2.24
9.7
2.57
8.8
269
54
15
18.9
15.2
2.22
9.6
2.50
8.5
264
52
10
17.0
13.6
2.17
9.2
2.29
7.8
254
44
MODEL: GPH1342M41*
5
15.0
12.1
2.12
8.7
2.08
7.1
244
38
0
13.1
10.6
2.07
8.3
1.85
6.3
234
32
-5
11.2
9.0
2.02
7.8
1.62
5.5
226
28
-10
9.2
7.4
1.97
7.2
1.36
4.6
218
22
HEATING OPERATION
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
MBh
50.3
47.6
44.8
41.9
40.0
38.8
36.0
33.2
27.5
25.4
23.4
28.5
27.6
25.6
23.6
19.6
18.1
16.7
Delta T
35.8
33.9
31.9
29.8
3.45
3.38
3.34
3.31
3.25
3.18
2.31
2.27
2.23
KW
3.58
3.52
AMPS
17.6
16.5
15.6
14.8
14.3
14.1
13.4
12.8
12.3
11.9
11.4
3.50
3.42
3.24
3.05
3.48
3.27
3.07
COP
4.11
3.96
3.80
3.62
14.0
13.5
13.0
12.4
12.0
11.7
11.1
10.4
11.9
11.2
10.5
EER
323
310
298
285
278
273
262
252
241
230
221
HI PR
LO PR
141
131
122
112
106
102
94
84
75
67
59
Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.
17
22.1
15.7
2.20
11.2
2.94
10.0
216
55
15
21.3
15.1
2.18
11.1
2.85
9.7
212
53
10
19.1
13.6
2.14
10.6
2.61
8.9
204
45
5
16.9
12.0
2.09
10.0
2.36
8.1
196
39
14.8
10.5
2.05
9.6
2.11
7.2
188
33
-5
12.6
9.0
2.01
9.0
1.84
6.3
181
29
-10
10.3
7.3
1.96
8.3
1.54
5.3
175
22
PERFORMANCE TEST
All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor
air cubic feet per minute (CFM) as listed in the Performance Data Sheets:
If conditions vary from this, results will change as follows:
1. As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low
and high side pressures and power will not change.
2. As indoor CFM decreases, a slight increase will occur in indoor temperature drop (Delta T). A slight decrease will
occur in low and high side pressures and power.
A properly operating unit should be within plus or minus 3 degrees of the typical (Delta T) value shown.
A properly operating unit should be within plus or minus 7 PSIG of the HI PR shown.
A properly operating unit should be within plus or minus 3 PSIG of the LO PR shown.
A properly operating unit should be within plus or minus 3 Amps of the typical value shown.
25
HEATING PERFORMANCE DATA
GPH13[48-60]M41*
EXPANDED PERFORMANCE DATA
MODEL: GPH1348M41*
HEATING OPERATION
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
MBh
57.2
54.1
51.0
47.6
45.5
44.1
41.0
37.8
32.8
30.2
27.8
Delta T
30.8
29.1
27.4
25.6
24.5
23.7
22.0
20.3
17.6
16.3
15.0
KW
3.90
3.83
3.75
3.68
3.63
3.60
3.53
3.46
2.48
2.43
2.38
AMPS
19.0
17.7
16.7
15.8
15.3
15.0
14.3
13.7
13.1
12.6
12.1
COP
4.29
4.14
3.97
3.79
3.66
3.58
3.39
3.20
3.86
3.64
3.42
EER
14.7
14.1
13.6
13.0
12.5
12.2
11.6
10.9
13.2
12.4
11.7
HI PR
372
357
343
328
320
314
302
290
278
265
255
LO PR
130
121
113
104
98
95
87
77
70
62
55
Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.
17
26.3
14.2
2.36
11.9
3.27
11.2
249
51
15
25.3
13.6
2.34
11.8
3.17
10.8
244
49
10
22.7
12.2
2.29
11.2
2.91
9.9
235
42
MODEL: GPH1360M41*
5
20.1
10.8
2.24
10.6
2.63
9.0
226
36
17.6
9.5
2.19
10.1
2.35
8.0
217
30
-5
15.0
8.1
2.14
9.5
2.05
7.0
209
26
-10
12.3
6.6
2.09
8.7
1.72
5.9
202
21
HEATING OPERATION
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
MBh
69.8
66.0
62.2
58.1
55.5
53.8
50.0
46.1
39.1
36.1
33.3
Delta T
35.9
34.0
32.0
29.9
28.5
27.7
25.7
23.7
20.1
18.6
17.1
KW
4.80
4.71
4.62
4.53
4.47
4.44
4.35
4.26
2.41
2.36
2.32
AMPS
24.1
22.5
21.2
20.1
19.4
19.1
18.1
17.3
16.7
16.0
15.4
COP
4.25
4.10
3.94
3.76
3.63
3.55
3.36
3.17
4.76
4.47
4.19
EER
14.5
14.0
13.5
12.8
12.4
12.1
11.5
10.8
16.3
15.3
14.3
HI PR
385
369
354
339
331
325
312
300
287
274
263
LO PR
134
124
116
107
101
97
89
80
72
64
56
Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.
17
31.4
16.2
2.30
15.0
4.00
13.7
257
52
15
30.3
15.6
2.28
14.9
3.88
13.2
252
50
10
27.1
14.0
2.24
14.2
3.54
12.1
243
43
5
24.1
12.4
2.20
13.4
3.20
10.9
233
37
21.0
10.8
2.16
12.8
2.84
9.7
224
31
-5
17.9
9.2
2.12
12.0
2.47
8.4
216
27
-10
14.7
7.5
2.08
11.0
2.06
7.1
208
21
PERFORMANCE TEST
All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor
air cubic feet per minute (CFM) as listed in the Performance Data Sheets:
If conditions vary from this, results will change as follows:
1. As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low
and high side pressures and power will not change.
2. As indoor CFM decreases, a slight increase will occur in indoor temperature drop (Delta T). A slight decrease will
occur in low and high side pressures and power.
A properly operating unit should be within plus or minus 3 degrees of the typical (Delta T) value shown.
A properly operating unit should be within plus or minus 7 PSIG of the HI PR shown.
A properly operating unit should be within plus or minus 3 PSIG of the LO PR shown.
A properly operating unit should be within plus or minus 3 Amps of the typical value shown.
26
WIRING DIAGRAMS
GPH13[24-42]M41AB
LPS
SEE NOTE #8
SEE NOTE #7
YL/PK
BK
1
RD
G
YL
BL
EBTDR
R
XFMR-R
YL
C
SPEED
UP
BL
K1
NO
K1
COM
M1
NC
M2
2
PU
3
BL
24V
BK
RD
PU
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
C
YL
LVJB
PU
WH
YL
H
C
3
F
R-DFT
RD
DFT
RCCF
SA
RD
PLF
6
9
2
5
8
1
4
7
PU
RD
RD
BL
BK
GR
S C R
2 SPEED
OPTIONAL
COMP
CHS
FC
RVC
C
COMPONENT LEGEND
C
COMP
C
C
S
2 POLE ONLY
SEE NOTE 7
HVDR
RCCF
H
F
S.A.
CM
SEE NOTE 5
EBTDR
M2
BR
1
3
2
4
N
O
P 3
L
F 1
SEE
NOTE 2
M1
BR
C
CCR
CH
CHS
CM
COMP
DC
DFT
EBTDR
EM
FC
GND
HPS
HVDR
LPS
LVDR
LVJB
PLF
RVC
RCCF
R
T1
EBTDR
NC
COM
EM
FC
208-240
SEE NOTE 4
SA
TR
2
1
BK
BK
L2
CH
T2
WARNING
SEE NOTE #3
SUPPLY VOLTAGE
208-240/1/60
SEE NOTE 3
CHS
RD
CM
FC
L1
RD
EM
BR
BK
CH
BK
YL
BR
HIGH
BR
DFT
SEE NOTE #3
RD
T
H
E
R
M
O
S
T
A
T
CONTROL
BOX
PU
BK
LOW
BK
3 SPEED
++
BK
PU
(COM) BK
Y
R
G
W1
O
W2
C
BR
PU
(TRANS240V)
PU (M1) RD
RD
EM
BR
BR
BL
SEE NOTE #5
HPS
YL
RD
GR
WH
OR
BR
BL
RD
R
PU
BL/PK
BR
WH
HVDR
BK
BL/PK
PU
RD
BK
R
DF1
RD
YL
W
DF2
RD
BK
PU
BK
RD
SEE NOTE
#6
C
PU
O-RV
LVDR
L1
2
0
8
2
4
0
/
1
/
6
0
GND
O
CCR
PU
T1
BK
OR
BK
OR
CNT
PS2
L2
PU
BK
C-RV
R-PS1 DC
BK
BK
4
BR
PU
C C
Y
PU
T2
3
2
RD
BK
Y
RD
RD
1
BL
BL
BL
208 240
C
RD
GR
PU
SEE NOTE 4
PU
BK
YL/PK
BLOWER INTERLOCK RELAY
CONTACTOR
COMPRESSOR CONTACTOR RELAY
CRANKCASE HEATER
CRANKCASE HEATER SWITCH
CONDENSER MOTOR
COMPRESSOR
DEFROST CONTROL
DEFROST THERMOSTAT
ELECTRONIC BLOWER TIME DELAY RELAY
EVAPORATOR MOTOR
FAN CAPACITOR
EQUIPMENT GROUND
HIGH PRESSURE SWITCH
HIGH VOLTAGE DEFROST RELAY
LOW PRESSURE SWITCH
LOW VOLTAGE DEFROST RELAY
LOW VOLTAGE JUNCTION BOX
FEMALE PLUG / CONNECTOR
REVERSING VALVE COIL
RUN CAPACITOR FOR
COMPRESSOR AND FAN
START ASSIST
TRANSFORMER
FACTORY WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH
VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
BK
BL
BR
GR
OR
PU
RD
WH
YL
WIRE CODE
BLACK
BLUE
BROWN
GREEN
ORANGE
PURPLE
RED
WHITE
YELLOW
3
TR
24V
EBTDR
NOTES:
R
C
G
DFT
RVC
R
C-RV
O-RV
R
O
W
R-DFT
DC
Y
R-PS1
DFT
PS2
C
CNT
LPS
4
P
L 5
F
6
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS
ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED REPLACE LEAD ON EBTDR
"COM" WITH LEAD ON EBTDR "M1" OR "M2".
3. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY
EQUIPPED WHEN REQUIRED.
4. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES
FROM TERMINAL 3 TERMINAL 2 ON TRANSFORMER.
5. START ASSIST FACTORY EQUIPPED WHEN REQUIRED.
6. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE.
7. DOUBLE POLE CONTACTOR SHOWN. SINGLE POLE CONTACTOR
COULD BE FACTORY EQUIPPED AS AN ALTERNATE CONFIGURATION.
8. COMMON SIDE OF CONTACTOR CAN NOT BE GROUNDED OR
CONNECTED TO ANY OTHER COMMON (24V).
C
HPS
SEE UNIT RATING PLATE FOR TYPE AND SIZE
OF OVER CURRENT PROTECTION
R
W2
O
W1
Y
THERMOSTAT
G
C
208-240/1/60 0140G01745-A
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
27
WIRING DIAGRAMS
GPH13[48-60]M41AB
SEE NOTE 8
SEE NOTE 3
PU
LPS
SEE NOTE 7
BK
PU
PU
YL/PK
1
2
3
C
208
240
YL/PK
PU
BL
24V
YL
BK
BL
RD
C
BL
BL
BK
BK
YL
2
0
8
2
4
0
/
1
/
L2
T2
RD
BL
SEE NOTE 5
L1
T1
PU
BK
BL
BK
PU
RD
PU
GR
GND
GR
60
Y C C C
Y
C-RV
PU
WARNING
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
OR
RD
O
PS2
CCR
YL
BK
O-RV
LVDR
RD
PU
CNT
R-PS1 DC
PU
OR
RD
RD
BR
WH
PU
GR
WH
W
LVJB
R
YL
BL
BL
DF2
WH
H
C
F
YL
RD
GR
WH
OR
BR
BL
PLF
BK
R
HVDR
GR
3
6
9
2
5
8
1
4
7
R-DFT
DF1
DFT
RD YL
RCCF
RD
BR
RD
BR
PU
YL
RD
BL/PK
CONTROL
BOX
RD RD
++
BK
BK
PU
SA
SEE NOTE 4
WH
GR
R
G
W1
O
W2
C
YL
PU
RD
PU BR BK
BL/PK
C L G N
1 2 3 4 5
SEE
NOTE 6
PU
CH
BK
YL
RD
RD
BK
CHS
S C R
DFT
T
H
E
R
M
O
S
T
A
T
WH
RD
GR
CM
BK BK
HPS
EM
BK
COMP
RVC
BK
SEE NOTE 6
SEE NOTE 2
L1
L2
SUPPLY VOLTAGE
208-240/1/60
T2
C
R
T1
C
COMP
C
S
2 POLE ONLY
SEE NOTE 7
COMPONENT LEGEND
C
CCR
CH
CHS
CM
COMP
DC
DFT
EM
GND
HVDR
LPS
LVDR
LVJB
PLF
RVC
RCCF
C
H
HVDR
RCCF
F
S.A.
CM
SEE NOTE 4
SEE NOTE 6
CHS
CH
SEE NOTE 2
N
L
EM
3
G
1
SA
TR
HPS
2
SEE NOTE 3
1
2
O-RV
C-RV
W
WIRE CODE
BK BLACK
BL BLUE
BR BROW N
GR GREEN
OR ORANGE
PU PURPLE
RD RED
WH W HITE
YL YELLOW
NOTES:
DFT
RVC
O
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
3
TR
R
FACT ORY WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTINAL HIGH
VOLTAGE
208-240
24V
R
CONTACTOR
COMPRESSOR CONTACTOR RELAY
CRANKCASE HEATER
CRANKCASE HEATER SWITCH
CONDENSER MOTOR
COMPRESSOR
DEFROST CONTROL
DEFROST THERMOSTAT
EVAPORATOR MOTOR
EQUIPMENT GROUND
HIGH VOLTAGE DEFROST RELAY
LOW PRESSURE SW ITCH
LOW VOLTAGE DEFROST RELAY
LOW VOLTAGE JUNCTION BOX
FEMALE PLUG / CONNECTOR
REVERSING VAVLE COIL
RUN CAPACITOR FOR
COMPRESSOR AND FAN
START ASSIST
TRANSFORMER
HIGH PRESSURE SWITCH
DFT
R-DFT
DC
Y
R-PS1
PS2
C
CNT
LPS
HPS
2
3
1 EM C
4
5
SEE NOTE 2
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS
ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTO R SPEED MOVE W HITE AND YELLOW
LEADS FROM EM"2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE
ENERGIZED, THE HIGHER SPEED SETTING IS USED.
3 FOR 208 VOLT TRANSFORMER O PERATION MOVE PURPLE WIRES FROM
TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
4. START ASSIST FACTORY EQUIPPED W HEN REQUIRED
5. USE COPPER CONDUCTORS ONLY
++ USE N.E.C. CLASS 2 WIRE
6. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY
EQUIPPED WHEN REQUIRED.
7. DOUBLE POLE CONTACTOR SHOWN. SINGLE POLE CONTACTOR
COULD BE FACTORY EQUIPPED AS AN ALTERNATE CONFIGURATION.
8. COMMON SIDE OF CONTACTOR CAN NOT BE GROUNDED OR
CONNECTED TO ANY OTHER COMMON (24V).
6
PLF
C
R W2 O W1 Y
THERMOSTAT
G
SEE UNIT RATING PLATE FOR TYPE AND SIZE
OF OVER CURRENT PROTECTION
C
208-240/1/60 0140G01640-A
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
28