17.0 Fault Finding Fault Finding Solutions Sections A Is there 230V at: 1. Main terminals L and N 2. Main terminal fuse 3. B NO Check electrical supply NO Replace fuse NO Check wiring PCB - X1 connector terminals 1,2 NO Display illuminated Is there 230V at: 1. X3 Connection Pump PCB NO Check incoming wiring YES X2 Connection Pump PCB NO Replace Pump PCB YES NO X1 Control PCB Check wiring YES X3 Control PCB, T3, T4 NO Replace Control PCB YES NO X1 Pump PCB Replace Pump PCB YES Replace Pump C 1. YES CH system pressure less than 0.5 bar NO 2. D 1. Check the tap of the automatic air vent is opened Fan connections correct at fan. PCB X2 connector, is 230V AC across terminals 3 & 4 Re-pressurise system Check connection water pressure switch terminal COM - NO and PCB connector X400 terminals 3,4 NO YES Fan jammed or faulty winding Replace PCB © Baxi Heating UK Ltd 2015 Replace water pressure switch Open the automatic air vent NO 50 YES YES Replace fan Replace PCB