Download TK-2212L
Transcript
TK-2212L ADJUSTMENT Receiver Section Item 1.BPF Wave Adjust Measurement Test equipment Terminal (1)Center frequency Spectrum ANT Spectrum analyzer setting analyzer BPF Center-f : 155MHz Span : 100MHz RBW : 30kHz VBW : 30kHz ATT : 5dB (2)High-edge frequency Spectrum analyzer setting Center-f : 174MHz Condition Adjustment Parts Method Programming Adjust the Software: waveform as KPG-100D shown to the right. Specifications/ Remarks REF -20.0 dBm MKR 155 MHz 10 dB/ A_View Norm B_Blank Norm -32.43 dBm MARKER 155 MHz CENTER 155 MHz SPAN 100.0 MHz VBW 30 kHz SWP 230 ms ATT 5 dB ∗RBW 30 kHz REF -20.0 dBm MKR 174 MHz 10 dB/ A_View Norm B_Blank Norm -30.70 dBm MARKER 174 MHz CENTER 174 MHz SPAN 100.0 MHz VBW 30 kHz SWP 230 ms ATT 5 dB ∗RBW 30 kHz (3)Low-edge frequency Spectrum analyzer setting Center-f : 136MHz REF -20.0 dBm MKR 136 MHz 10 dB/ A_View Norm B_Blank Norm -30.73 dBm MARKER 136 MHz CENTER 136 MHz SPAN 100.0 MHz VBW 30 kHz SWP 230 ms ATT 5 dB ∗RBW 30 kHz 2.Sensitivity Check [Wide] [Narrow] 3.SQL1 (Threshold) Writing [Wide] [Narrow] 4.SQL9 (Tight) Writing [Wide] [Narrow] 5.BATT detection Writing TEST CH: Low Center High SSG output:–117 dBm(0.3µV) SSG MOD:3.0kHz TEST CH: Center SSG output:–115 dBm(0.4µV) SSG MOD:1.5kHz TEST CH: Center Low High SSG output:–123 dBm(0.16µV) SSG MOD:3.0kHz TEST CH: Center SSG output:–122 dBm(0.18µV) SSG MOD:1.5kHz TEST CH: Center Low High SSG output:–117 dBm(0.3µV) SSG MOD:3.0kHz TEST CH:Center SSG output:–116 dBm(0.35µV) SSG MOD:1.5kHz BATT terminal voltage:5.9V SSG DVM Oscilloscope AF VTVM ANT Programming Software: KPG-100D DVM ANT BATT terminal Check 12dB SINAD or more Write Squelch open BATT terminal voltage:5.9V 21