Download Operating Instr
Transcript
Model 8000 Computron 2-3. SPECIAL PROGRAM MODE (Continued) Amps Reading High Limit (SP-14) This is the percentage above the Nominal Amp Reading in which the controls senses a too high amperage warning (E25). Preset at 110%, but can be changed (101 to 150%): a. Follows steps 1 and 2 above. b. Press until "SP-14" and "AMPS RDG, HIGH LIMIT" shows in display, along with the preset percentage. c. Press and release to change percentage. Program Code Change (SP-15) This allows the operator to change the program code (factory set at 1, 2, 3) used to access Product Programming, Special Programming, Clock Set, Data Comm, and Heat Control modes. a. Follows steps 1 and 2 above. b. Press until "SP-15" and "CHANGE, MGR CODE, 1=YES” shows in display, along with “CODE”. c. Press . “ENTER NEW CODE, P=DONE, I=QUIT” shows in display. Press Product buttons with new code. d. If satisfied with code, press . “REPEAT NEW CODE, P=DONE, I=QUIT, shows in display. Press same code buttons in step c. e. If satisfied with code, press shows in display. . *CODE CHANGE* f. If not satisfied with code, press and *CANCELLED* shows in display, then reverts back to "SP-15" and "CHANGE, MGR CODE, 1=YES”. Then the above steps can be repeated. Press and hold Mode. 602 at any time to exit Special Program 2-15