Download SERVICE MANUAL
Transcript
KV-ES29M31/ES29M61 RM-916 6. SELF-DIAGNOSTIC CIRCUIT IC4301 RGB JUNGLE OVP OCP FROM CRT (IK) IC001 SYSTEM 3 IC003 MEMORY SDA 25 IKIN 5 6 [H] IC6801 20 XRAY LED 54 [V] D6806/D6801 16 V PROT SDA 5 CXA2100Q IC004 MEMORY [+B overcurrent ªOCPº] Occurs when an overcurrent on the +B(135) line is detected by Q6610 and Q6609. If Q6610 and Q6609 go to ON, the voltage to the pin3 of IC001 go to UP. The unit will automatically turn off. [+B overvoltage ªOVPº] Occurs when an overvoltage on the +B(135) line is detected by D6635, Q6611 and Q6612. If Q6611 and Q6612 go to ON, the voltage to pin6 of IC001 go to UP. The unit will automatically turn off. [Vertical deflection failure] Occurs when an absence of the vertical deflection pulse is detected by Q6811, Q6819, Q6820, Q6821 and D6801. Shut down the power supply. [White balance failure] If the RGB levels do not balance or become low level within 5 seconds. This error will be detected by IC4301. TV will stay on, but there will be no picture. [High voltage protector of Horizontal Deflection] Occurs when an overvoltage of horizontal pulse is detected by D6809 and IC6801. If the voltage of 7 pin of IC6801 goes to High, the voltage to pin20 of IC4301 go to UP. The unit will automatically turn off. –7– http://cxema.ru