Download Electronics and HWH

Transcript
Circuit breakers can be reset automatically or manually. The use of automatic circuit breakers is not
recommended. Poly fuses are unique in the fact they don’t have to be replaced or reset after “tripping”. As the
current rating of the poly fuse is exceeded, the heat will cause the material of the poly fuse to totally resist the
flow of current. The poly fuse will remain “open” until current is removed from the supply side of the fuse or
the overload or short is removed from the load side of the fuse. Fuse size is very important. Something that is
quite often overlooked is the traces on pc boards. Fuses are also sized to protect these traces. Correct fuse size
must always be maintained. When too large a fuse is used, the wiring or traces are put in jeopardy. Traces can
easily be burnt when fuses are oversized and this usually is an expensive repair. Wiring can overheat which can
cause a fire. This is an even more expensive repair. Too small of a fuse will not usually cause damage but will
certainly affect the performance of the system by causing a break in the circuit even though the circuit is
operating well within its rated capacities. The main thing to remember about fuses when diagnosing fuse issues
is; only an overload or short on the load side of a fuse will cause a fuse to open or trip. No issue on the
voltage/current supply side of the fuse can cause a fuse to open or trip.
FUSE
200 AMP
PUMP
RELAY
PUMP
MOTOR
M
+12
VOLTS
NOT
PROTECTED
PROTECTED
Fig. 8
2-5 DIODES are electronic devices used to control the direction current can flow. A diode will only allow
current to pass through in one direction. The directions are referred to as forward and reverse bias. A diode
installed into a circuit with a forward bias will allow the current to flow through. A diode installed with a
reverse bias will block the flow of current. There are different types of diodes including LEDs which are “light
emitting diodes”. We use many diodes and LEDs in our systems, but most of them are mounted on pc boards or
installed in a component such as the large solenoid valves and are not serviceable in the field. It is not even
important to be able to diagnose diode issues when they are part of component. But sometimes when necessary,
a diode may be used in a harness. When there is a diode in a harness, the harness will have a “DIODE” label at
the point where the diode is installed. One way to check a diode with a meter is to set the meter to “DIODE
CHECK”. When checked in the forward bias, the meter should read approximately .5 volts. When checked in
the reverse bias, the meter should read OL or open.
FORWARD BIAS CHECK
.512
DIODE SYMBOL
NOTE: Some
styles of diodes
when checked CURRENT FLOW
in the forward
bias mode will
DIODE
read a different
Power for the circuit
voltage.
must be off to use
the "diode" check.
Meter could be
damaged if power is on.
+12
VOLTS
RED
BLACK
REVERSE BIAS CHECK
OL
+12
VOLTS
BLACK
RED
Fig. 9
If the reading in both directions is “OL”, the diode is open.
It the reading in both directions is 0.00, the diode is shorted.
If there is a diode in a harness wire, a continuity check of that wire cannot be performed.
7