Download Electronics and HWH
Transcript
Circuit breakers can be reset automatically or manually. The use of automatic circuit breakers is not recommended. Poly fuses are unique in the fact they don’t have to be replaced or reset after “tripping”. As the current rating of the poly fuse is exceeded, the heat will cause the material of the poly fuse to totally resist the flow of current. The poly fuse will remain “open” until current is removed from the supply side of the fuse or the overload or short is removed from the load side of the fuse. Fuse size is very important. Something that is quite often overlooked is the traces on pc boards. Fuses are also sized to protect these traces. Correct fuse size must always be maintained. When too large a fuse is used, the wiring or traces are put in jeopardy. Traces can easily be burnt when fuses are oversized and this usually is an expensive repair. Wiring can overheat which can cause a fire. This is an even more expensive repair. Too small of a fuse will not usually cause damage but will certainly affect the performance of the system by causing a break in the circuit even though the circuit is operating well within its rated capacities. The main thing to remember about fuses when diagnosing fuse issues is; only an overload or short on the load side of a fuse will cause a fuse to open or trip. No issue on the voltage/current supply side of the fuse can cause a fuse to open or trip. FUSE 200 AMP PUMP RELAY PUMP MOTOR M +12 VOLTS NOT PROTECTED PROTECTED Fig. 8 2-5 DIODES are electronic devices used to control the direction current can flow. A diode will only allow current to pass through in one direction. The directions are referred to as forward and reverse bias. A diode installed into a circuit with a forward bias will allow the current to flow through. A diode installed with a reverse bias will block the flow of current. There are different types of diodes including LEDs which are “light emitting diodes”. We use many diodes and LEDs in our systems, but most of them are mounted on pc boards or installed in a component such as the large solenoid valves and are not serviceable in the field. It is not even important to be able to diagnose diode issues when they are part of component. But sometimes when necessary, a diode may be used in a harness. When there is a diode in a harness, the harness will have a “DIODE” label at the point where the diode is installed. One way to check a diode with a meter is to set the meter to “DIODE CHECK”. When checked in the forward bias, the meter should read approximately .5 volts. When checked in the reverse bias, the meter should read OL or open. FORWARD BIAS CHECK .512 DIODE SYMBOL NOTE: Some styles of diodes when checked CURRENT FLOW in the forward bias mode will DIODE read a different Power for the circuit voltage. must be off to use the "diode" check. Meter could be damaged if power is on. +12 VOLTS RED BLACK REVERSE BIAS CHECK OL +12 VOLTS BLACK RED Fig. 9 If the reading in both directions is “OL”, the diode is open. It the reading in both directions is 0.00, the diode is shorted. If there is a diode in a harness wire, a continuity check of that wire cannot be performed. 7