TABLE 5 - Motor Vehicle Air Conditioning Substitutes for CFC-12 (Reviewed Under EPA’s SNAP Program as of March 29, 2006)
Acceptable Subject to Use Conditions*
Name (1)
Date
Manufacturer
Components
HCFC-
HCFC-
HCFC-
HFC-Butane
Isobutane
22
124
142b
134a
(R-600)
(R-600a) (3)
(3)
HFC-134a
3/18/94Several
-
-
-
100
-
-
Intercool
FRIGC
6/13/95
Distribution
-
39
-
59
2
-
FR-12
800-555-1442
Free Zone/
Hi Tech
RB-276 (4)
5/22/96
Refrigerants, LLC
-
-
19
79
-
-
800-530-4805
Ikon-12
5/22/96
Ikon Corp.Composition claimed as confidential business information
601-868-0755
R-406A/
10/16/96
People’s Welding
55
-
41
-
-
4
GHG(5)
800-382-9006
GHG-HP (5)
10/16/96
People’s Welding
65
-
31
-
-
4
800-382-9006
People’s Welding
GHG-HP
800-382-9006
Autofrost
10/16/96
McMullen Oil 51
28.5
16.5
-
-
4
Chill-It (5)
Products
800-669-5730
Hot Shot/
10/16/96
ICOR
50
39
9.5
-
-
1.5
Kar Kool (5)
800-357-4062
Technical
Freeze 12
10/16/96Chemical
-
-
20
80
-
-
800-527-0885
GHG-X5
6/3/97
People’s Welding
41
-
15
-
-
4
800-382-9006
SP34E
12/18/00SolpowerComposition claimed as confidential business information
888-289-8866
RS-24
12/20/02
RefrigerantComposition claimed as confidential business information
Products Ltd
R420-A
3/29/06
RMS of Georgia
-
-
12
88
-
-
HFC
227ea
-
-
40
-
Unacceptable Substitutes
Name (1)
Date
Manufacturer
Reason
OZ-12®
3/18/94OZ TechnologyFlammable blend of hydrocarbons. insufficient data to demonstrate safety
R-176
3/18/94Arctic ChillContain CFC-12, which is inappropriate in a CFC-12 substitute
HC-12a©
6/13/95OZ TechnologyFlammable blend of hydrocarbons. insufficient data to demonstrate safety
Duracool 12a
6/13/95
Duracool This blend is identical to HC12a© in composition but is manufactured by a different company
Limited
R405A
6/13/95
GreencoolContains a perfluorocarbon, which has extremely high global warming
potential and lifetime
*USE CONDITIONS:
1. Many refrigerants, including R401A (made by DuPont), R401B (DuPont), R409A (Elf Atochem), Care 30 (Calor Gas), Adak-29/Adak-12 (TACIP Int’l), MT-31 (Millennia Tech), and ES-12R
(Intervest), have not been submitted for review in motor vehicle air conditioning, and it is therefore illegal to use these refrigerants in such systems as an alternative to CFC-12.
2. Acceptable Subject to Use Conditions regarding fittings, labeling, no drop-in, and compressor shutoff switches.
Unacceptable; illegal for use as a CFC-12 substitute in motor vehicle air conditioners
3. Although some blends contain flammable components, all blends that are Acceptable Subject to Use Conditions are nonflammable as blended.
4. Freezone contains 2% of a lubricant
5. HCFC-22 content results in an additional use condition: must be used with barrier hoses
© 2008 Mobile Air Conditioning Society Worldwide