Download Certification Training Manual - Mac`s
Transcript
Certification Training Manual TABLE 5 - Motor Vehicle Air Conditioning Substitutes for CFC-12 (Reviewed Under EPA’s SNAP Program as of March 29, 2006) Acceptable Subject to Use Conditions* Name (1) Date Manufacturer Components HCFC- HCFC- HCFC- HFC-Butane Isobutane 22 124 142b 134a (R-600) (R-600a) (3) (3) HFC-134a 3/18/94Several - - - 100 - - Intercool FRIGC 6/13/95 Distribution - 39 - 59 2 - FR-12 800-555-1442 Free Zone/ Hi Tech RB-276 (4) 5/22/96 Refrigerants, LLC - - 19 79 - - 800-530-4805 Ikon-12 5/22/96 Ikon Corp.Composition claimed as confidential business information 601-868-0755 R-406A/ 10/16/96 People’s Welding 55 - 41 - - 4 GHG(5) 800-382-9006 GHG-HP (5) 10/16/96 People’s Welding 65 - 31 - - 4 800-382-9006 People’s Welding GHG-HP 800-382-9006 Autofrost 10/16/96 McMullen Oil 51 28.5 16.5 - - 4 Chill-It (5) Products 800-669-5730 Hot Shot/ 10/16/96 ICOR 50 39 9.5 - - 1.5 Kar Kool (5) 800-357-4062 Technical Freeze 12 10/16/96Chemical - - 20 80 - - 800-527-0885 GHG-X5 6/3/97 People’s Welding 41 - 15 - - 4 800-382-9006 SP34E 12/18/00SolpowerComposition claimed as confidential business information 888-289-8866 RS-24 12/20/02 RefrigerantComposition claimed as confidential business information Products Ltd R420-A 3/29/06 RMS of Georgia - - 12 88 - - HFC 227ea - - 40 - Unacceptable Substitutes Name (1) Date Manufacturer Reason OZ-12® 3/18/94OZ TechnologyFlammable blend of hydrocarbons. insufficient data to demonstrate safety R-176 3/18/94Arctic ChillContain CFC-12, which is inappropriate in a CFC-12 substitute HC-12a© 6/13/95OZ TechnologyFlammable blend of hydrocarbons. insufficient data to demonstrate safety Duracool 12a 6/13/95 Duracool This blend is identical to HC12a© in composition but is manufactured by a different company Limited R405A 6/13/95 GreencoolContains a perfluorocarbon, which has extremely high global warming potential and lifetime *USE CONDITIONS: 1. Many refrigerants, including R401A (made by DuPont), R401B (DuPont), R409A (Elf Atochem), Care 30 (Calor Gas), Adak-29/Adak-12 (TACIP Int’l), MT-31 (Millennia Tech), and ES-12R (Intervest), have not been submitted for review in motor vehicle air conditioning, and it is therefore illegal to use these refrigerants in such systems as an alternative to CFC-12. 2. Acceptable Subject to Use Conditions regarding fittings, labeling, no drop-in, and compressor shutoff switches. Unacceptable; illegal for use as a CFC-12 substitute in motor vehicle air conditioners 3. Although some blends contain flammable components, all blends that are Acceptable Subject to Use Conditions are nonflammable as blended. 4. Freezone contains 2% of a lubricant 5. HCFC-22 content results in an additional use condition: must be used with barrier hoses © 2008 Mobile Air Conditioning Society Worldwide 43