Download Certification Training Manual - Mac`s
Transcript
Certification Training Manual System Components SAE J51: “Automotive Air Conditioning Hose” This document covers CFC-12 emission rates for refrigerant hose use on mobile air conditioning systems. This document does not cover the hose coupling integrity. SAE J2064: “R134a Refrigerant Automotive Air Conditioning Hose” The revised document addresses hose assembly refrigerant leakage and was published in 2005. This SAE Standard covers hose and hose assemblies intended for conducting liquid and gaseous R134a refrigerant in automotive air-conditioning systems. The hose shall be designed to minimize permeation of R134a refrigerant, contamination of the system, and to be functional over a temperature range of -30° C to 125° C. Specific construction details are to be agreed upon between user and supplier. A hose marked “J2064” signifies that it has been coupled, tested, and has met the requirements of SAE J2064. It is the hose assembly manufacturer’s responsibility to see that the assemblies meet the specified acceptance criteria for this specification. Service Activities SAE J2196: “Service Hose for Automotive Air Conditioning” This defines service equipment (gauge lines) hose emission rates and construction requirements for service hoses. Revised November 1998. SAE J2197: “HFC-134a Service Hose Fittings for Automotive Air Conditioning Service Equipment” To prevent mixing of HFC-134a with other refrigerants, a 1/2 inch Acme thread fitting for containers was developed by the “Compressed Gas Association” (CGA). This 1/2 inch Acme thread is also required on HFC-134a automotive service equipment. Revised March 1997. SAE J2297: “Stability and Compatibility Criteria of Fluorescent Refrigerant Leak Detection Dyes for Mobile R134a Air Conditioning Systems” This provides requirements for material compatibility of trace dye material with mobile A/C systems. Published September 1996. SAE J2298: “Use of Refrigerant Leak Detection Dyes for Service of Mobile Air Conditioning Systems” This covers the procedures, including safety requirements, when using trace dye to determine if the A/C system has a refrigerant leak. Published September 1996. SAE J2299: “Performance Requirements for Leak Detection Dye Injection Equipment” This document establishes the requirements for the equipment required to install trace dye material into the refrigerant circuit of a mobile A/C system. Published September 1996. SAE J2670: “Stability and Compatibility Criteria for Additives and Flushing Materials Intended for Use in Vehicle Air-Conditioning Systems Using R134a” The purpose of this standard is to provide testing and acceptance criteria to evaluate the stability and compatibility of chemicals, including flushing materials and additives (e.g., to enhance lubrication, durability, cooling performance, energy performance, prevent/fix leaks) intended for use in R134a vehicle air conditioning systems. Successful completion of all requirements contained in this specification indicates acceptable compatibility with the A/C system materials, but does not suggest that the additive improves system performance in any way. This SAE standard applies to any and all additives and chemical solutions intended for aftermarket use in the refrigerant circuit of vehicle air-conditioning systems. This standard provides testing and acceptance criteria for determining the stability and compatibility of additives and flushing materials (solutions) with A/C system materials and components, that may be intended for use in servicing or operation of vehicle air conditioning systems. This standard does not provide test criteria for additive, compressor lubricant, or flushing solution effectiveness; such testing is the responsibility of the additive and/or solution manufacturer/supplier. It is not the intent of this document to identify the requirements for Standard J2297 Ultraviolet Leak Detection: Stability and Compatibility Criteria of Fluorescent Refrigerant Leak Detection Dyes for Mobile R134a Air-conditioning Systems. All leak detection materials must meet the requirements of J2297. Published in 2005. SAE J2776: “Refrigerant Purity and Container Requirements for New HFC-134a 1,1,1,2-Tetrafluoroethane Refrigerant Used in Mobile Air-Conditioning Systems” The purpose of this SAE Standard is to establish the minimum level of purity required and container specifications for new HFC-134a refrigerant used in mobile air-conditioning (A/C) systems. The refrigerant shall meet all the requirements as identified in ARI 700-2004 and all future ARI standards for HFC-134a. Published October 2006. Technician Service Procedures SAE J1628: “Technician Procedure for Using Electronic Refrigerant Leak Detectors for Service of Mobile Air Conditioning Systems” This document provides guidelines for the technician when using an electronic leak detector in determining a system refrigerant leak. Published November 1998. SAE J1989: “Recommended Service Procedure for the Containment of CFC-12 (R12)” This document covers the technician refrigerant recovery/recycling procedures when servicing CFC-12 (R12) mobile A/C systems and identification of excess NCG’s. Revised November 1998. © 2008 Mobile Air Conditioning Society Worldwide 49