Download 1 2
Transcript
Indoor unit Earth screw Closed end connector WHI RED S(N) F CN067 (BLK) RY007 1 2 1 2 4 43F1 3 5 43F1 1 2 3 4 1 2 3 4 GRY FM Remote controller 1 2 1 2 CN1 (WHI) A B 1 2 3 1 3 RC U1 U2 OC U1 U2 EMG 1 2 CN044 CN040 CN041 (BRW) (BLU) (BLU) Outdoor unit YEL Closed end connector Fuse T5.0A CN066 (WHI) RED RED 6 Flow selector unit earth screw TR 1 2 1 1 2 2 3 3 RED RC L 3 3 2 1 1 F4 F3 F2 X Y F1 WHI MCC-1401 Network adaptor (Option) 1 2 CN03 1 2 (RED) CN01 1 2 (WHI) 1 2 DP DP LM 1 2 3 1 2 3 1 2 1 2 CN075 CN061 (WHI) (YEL) CN032 (WHI) CN060 (WHI) CN082 (BLU) CN081 (BLK) TR 1 2 3 4 5 6 CN01 1 2 3 4 5 6 (WHI) Sub P.C. board MCC-1520 1 2 3 4 5 6 CN02 1 2 3 4 5 6 (YEL) Motor over heating protection switch WHI GRY RED BLK Wired for MMD-AP0481 only (BRN Wire) 49F ORN BRN BLU 6 5 4 3 2 1 Symbol FM RC TR TA TC1,TC2,TCJ RY005~007 RY001 RY002 PMV F 43F1 Sold DM separately FS 6 5 4 3 2 1 1 2 3 4 5 5 2 1 3 4 6 5 2 1 3 4 6 PMV Parts name Fan motor Running capacitor Transformer Indoor temp sensor Temp sensor Fan motor control relay Flap motor control relay Drain control relay Pulse Motor Valve Fuse Fan motor control relay Drain pump motor Float switch 1 Filter 2 1 EXCT 2 CN073 (RED) CN070 (WHI) 1 2 PNL 3 CN080 (GRN) 1 2 3 CN100 1 2 3 (BRN) TC1 1 2 3 4 5 6 1 2 3 4 5 6 1 2 1 2 3 4 5 6 Option 1 2 3 4 5 6 T10 Fan drive Power supply circuit 1 2 1 2 TC2 CN104 CN102 CN101 (YEL) (RED) (BLK) 1 2 1 2 TCJ Indoor control P.C. board FS CN030 (RED) 1 2 3 1 2 3 TA 1. indicates the terminal block, letter at inside indicates the terminal number. 2. A dotted line and broken line indicate the wiring at site. 3. indicates the control P.C. board. 4. When attaching a drain pump, exchange CN030 connector with a connector of the float switch. 5. A part is connected to the terminal block. When exchanging to the outside static pressure necessary at the local site, check the terminal No. and lead color of the fan motor in the below diagram, and then exchange the lead wire indicated by the arrow mark ( ), 6. Pay attention to change static pressure because the outside static pressure of H tap in 50 or 60Hz. CN074 (WHI) RY001 1 2 3 (BLU) 1 2 3 (GRN) 1 2 3 CN068 1 2 3 CN033 RY002 UL 1 2 3 4 5 CN050 (WHI) RY005 RY006 M CN02 (BLU) H FAN 9 8 7 6 4 2 CN083(WHI) 9 8 7 6 5 4 3 2 1 7 RY004 P301 43F1 1 1 CN309 2 2 (YEL) 3 3 3 CN304 (GRY) 2 1 (BLK) T10A,250V~ Power supply Single phase 220-240V 50Hz 220V 60Hz R(L) RED RED : RED WHI : WHITE YEL : YELLOW BLU : BLUE BLK : BLACK GRY : GRAY PNK : PINK ORN : ORANGE BRW : BROWN GRN : GREEN 8 BLU WHI (Option) ORN Color indication WHI RED GRY WHI RED BLK 32 BRN Spark killer 1-2-8. Concealed Duct High Static Pressure Type Models: MMD-AP0181H, AP0241H, AP0271H, AP0361H, and AP0481H