Download HEARTSTART MRx
Transcript
MONITOR/DEFIBRILLATOR Environmental Airway Respiration Rate Range: 0 to 150 rpm Resolution: 1 rpm Accuracy: 0 to 40 rpm ±1 rpm 41 to 70 rpm ±2 rpm 71 to 100 rpm ± 3% 101 to 150 rpm ±5% Alarm Range: Low Limit: 0 to 99 rpm (Adult/Pediatric) High Limit: 10 to 100 rpm (Adult/Pediatric) Apnea Alarm Time: 10-40 seconds, in increments of 5 Calibration Gas for CO2 Measurement Temperature: 0º C to 45ºC operating, -20º to 70ºC storage Humidity: Up to 95% relative humidity Altitude: Operating: 0 to 15,000 ft. (0 to 4,500 m) Storage: 0 to 15,000 ft. (0 to 4,500 m) Mechanical Shock: Operating Impact: Half-sine waveform, duration < 3 ms, velocity change > 111 in/s ± 5% 3 times on all six faces (i.e., axes) Non-operating Shipping: Trapezoidal waveform, acceleration > 30 g, velocity change=742 cm/s ± 10% on all six faces (i.e., axes) Bump: EN60068-2-29 Bump (Half-sine, 40 g peak, 6 msec duration, 1,000 bumps x 3 axes) Free fall: IEC 68-2-32 Free fall. Drops on all faces onto a steel surface (excluding bed rail hook) Ingredients: 5% Carbon Dioxide, 21% Oxygen, 74% Nitrogen - ? in. (? cm) with carrying case Cylinder Size: BD - ? in. (? cm) without carrying case Method of Preparation: Gravimetric - ? in. (? cm) onto handle Blend Tolerance: 0.03% Vibration: Accuracy: 0.03% absolute Moisture: 10 PPM Maximum Expiration Period: 2 years Pressure: 144 PSIG, Volume: 1L 12-Lead ECG Inputs: With a 10-Lead cable, leads I, II, III, aVR, aVL, aVF, V/C1-V/C6 can be obtained. All 12-Lead ECG waves can be viewed on the display simultaneously. All 12 leads can be printed on the strip chart printer in 3x4 format. 12-Lead ECG Transmission: Data card to a PC Receiver Type: HeartStart Event Review Pro Operating: MIL STD 810E 514.4 Category 6 Helicopter, General Storage, UH60 Non-Operating: - IEC 68-2-6 Vibration (sinusoidal) (10-57 Hz, +/- 0.15mm; 58-150 Hz, 2g; 20 sweeps x 3 axes) - IEC 68-2-64 Vibration, broad-band random (10-20 Hz, 0.05 g2/Hz; 20-150 Hz, -3 dB/octave; 150Hz, 0.0065g2/Hz; 1.5 hours x 3 axes) Solids/Water Resistance: IP24. Water testing performed with patient cables connected to the device EMC: Meets EN 60601-1-2:2001 Safety: Meets EN 60601-1, UL 2601-1, CAN/CSA C22.2 No. 601-1 Patient Data Storage Other Considerations: Device not suitable for use in the presence of Internal Event Summary: 8 hours of continuous ECG waveforms and concentrated oxygen or a flammable anesthetic mixture with air, oxygen, or events AND 50 12-Lead ECG reports nitrous oxide Data Card Event Summary: 8 hours of continuous ECG waveforms and Mode of Operation: Continuous events AND 50 12-Lead ECG reports AC Line Powered: Input: 100-240 VAC, 50-60 Hz, 1-0.46 A Output: 18 V, 5 A, 90 W Battery Powered: 14.8 V Rechargeable, Lithium Ion