Download ERMO 482X

Transcript
 CIAS Elettronica S.r.l.
Ed 3.1
TRANSMITTER TERMINAL STRIP J5
Terminal strip for balanced line and battery
N°
1
2
3
4
Acronym
SYNC
IN-BAL
GND
BAT
Function
Input / output synchronism for Tx Master/Slave (Preset Jp5)
Balanced line auxiliary input
Ground connection for Battery, Balanced line, Sync
Connection +13,8 VDC for Battery (Fuse protection F2 = 2A )
TRANSMITTER CONNECTOR J1
Connector for alarms repeater and RS 485
N°
Acronym
1
2
3
4
5
6
7
8
9
10
MAN
GUA
+13,8
SYN
LO485
TMP2
LH485
STBY
GND
TST
Function
Control output auxiliary Tamper relay (Normal GND)
Control output auxiliary failure relay (Normal GND)
Power supply auxiliary output (13,8 VDC)
Input / output synchronism for Tx Master/Slave (Preset Jp5)
Low Line for RS 485 (Line closure Preset Jp4)
Tamper external input (Normal GND, exclusion Preset Jp2)
High Line for RS 485 (Line closure Preset Jp4)
Auxiliary input for Stand-By Control (Normal Open from GND)
Ground Auxiliary output
Auxiliary input for Test Control (optional) (Normal Open from GND)
TRANSMITTER CONNECTOR J3
Connector for test instrument STC 95
N°
1-3
4
5
6
7-11
12
13
14-15
16
Acronym
N.C.
GND
N.C.
+13,8
N.C.
+5
+4,5
N.C.
+9
Function
Not used
Ground Auxiliary output for STC 95
Not used
Power supply auxiliary output (13,8 VDC) for STC 95
Not used
Power supply auxiliary output (5 VDC) for STC 95
Test output Oscillator functionality for STC 95
Not used
Output auxiliary voltage test Tx (9 VDC) for STC 95
TRANSMITTER CONNECTOR J4
Connector for Microwave Oscillator (DRO)
N°
Acronym
1
2
3
GND
DRO
GND
Function
Ground connection for Microwave Oscillator
Modulation frequency connection for Microwave Oscillator
Ground connection for Microwave Oscillator
TRANSMITTER CONNECTOR J6
Connector for battery address setting
N°
Acronym
1
2
3
+5
ING
GND
Function
Power supply auxiliary output (5 VDC).
Control input for battery address setting
Ground connection
Manuale d’installazione
pagina 40 di 55
ERMO 482X