8
Troubleshooting
Problem
Remedy
Excessive vibration
Loose parts or damaged auger.
Stop engine immediately and disconnect
spark plug wire. Tighten all bolts and nuts. If
vibration continues, have unit serviced by an
authorized Service Center.
Loss of power
Spark plug wire loose.
Connect and tighten spark plug wire.
2. Gas cap vent hole plugged.
2. Remove ice and snow from gas cap. Be
certain vent hole is clear.
Drive control cable in need of adjustment.
Adjust drive control cable. Refer to
Maintenance section
2. Drive belt loose or damaged.
2. Replace drive belt.
3. Friction wheel worn.
3. Replace Friction Wheel.
Chute assembly clogged.
Stop engine immediately and disconnect
spark plug wire. Clean chute assembly and
inside of auger housing with clean-out tool
or a stick.
2. Foreign object lodged in auger.
2. Stop engine immediately and disconnect
spark plug wire. Remove object from auger
with clean-out tool or a stick.
3. Auger control cable in need of adjustment.
3. Refer to Auger Control Test.
Auger belt loose or damaged.
Refer to Maintenance section.
5. Shear pin(s) sheared.
5. Replace with new shear pin(s).
Improper adjustment of Chute Bracket.
Refer to Maintenance Section for Chute
Bracket Adjustment.
Unit fails to propel itself
Unit fails to discharge snow
Chute Fails to Rotate
22
Cause