Download CentriPro - Pump Express
Transcript
Ratings WARNING Refer to serial number label on enclosure. Required Materials • BF Pump Controller with Transducer and Transducer Wire • Pump (water end) (see Speed Selector Switch for 60 Hz or 80 Hz Operation) • Motor: 230 V, three phase (3Ø), 3450 RPM • Pressure Relief Valve – piped to a drain for safety • Pressure Gauge – for setting system pressure • Heat Shrink Kit – one required for each underwater or underground splice (mandatory) • Tank Tee or (2) ¼" NPT Female pipe fittings for pressure sensor and pressure gauge connections • Pipe and fittings – as necessary per each system • Disconnect Switch: 230 V, 2 pole, properly sized (see Controller, Breaker, Generator Sizing Table) • Copper Wire: Minimum 75ºC rated wire, double jacketed is recommended but not mandatory (see Wire Sizing table) • Tank: diaphragm style tank (see Tank Sizing Section and Chart) 2: INSTALLATION Determine where the Controller, Pressure Tank and Transducer will be located before starting the installation. Controller The controller is rated NEMA 3R (Raintight) so it may be located outdoors. It must be mounted vertically. Locate the enclosure in a shaded area where the temperature stays within 0ºF to +122ºF (-18ºC to +50ºC). Since the controller is designed for outdoor mounting it may be located at the wellhead. Opening Controller Cover CAUTION Lay the controller on a flat surface or hang on wall before removing the cover screw. Failure to do so may result in dropping and damaging the unit. Once screw is removed, lift the cover up and out to remove. There is a locking tab on the bottom of the unit to accommodate a padlock if so desired. Mounting Controller Three screws are provided for mounting the enclosure. Using the enclosure as a guide, select a mounting location. First install the top screw in the mounting surface leaving the head of the screw approximately 1⁄8" from the surface. Hang the enclosure on this screw. Finish by installing the two bottom screws and tightening the top screw. Be sure to leave a minimum of 6" of clearance on each side of the controller to ensure proper cooling. EXPLODING TANK CAN INJURE OR KILL. Always protect the tank from over pressure by installing a pressure relief valve large enough to limit the system pressure below the maximum working pressure of the tank. Install the tank at a point in the system where the maximum possible system pressure cannot exceed the maximum working pressure of the tank. Install the pressure relief valve at the tank. CAUTION Avoid property damage caused by pressure relief valve opening. Pipe the pressure relief valve discharge to a drain or other location so that property damage and flooding will not occur. CAUTION Locate the tank and transducer where they will not freeze. Ensure the system pressure setting does not exceed the maximum working pressure of the tank. For optimum performance, as a minimum, we recommend using the same size pipe as the pump discharge between the pump and the tank. Smaller diameter pipe may severely limit the maximum capacity of the system. On long runs, larger pipe may be beneficial for optimum performance and flow. CAUTION If using a torque arrestor, install it on the discharge pipe before connecting pipe to the discharge head. Diaphragm Tank Sizing and Pre-Set Pressure Recommendations: Diaphragm type (captive air) tanks are required on these systems. Table 1: Tank Sizing Selection Maximum Pump GPM 10 23 41 70 100 Total Volume 2 4.5 8.2 13.9 19.9 Recommended Tanks Order No. or V6P V15P V25P V45 V60 Order No. TP6P TP15P TP25P TP45 TP60 Use Total Tank Volume, not drawdown volume, to select the proper tank size. The total tank volume should be approximately 20% of the pump’s maximum flow. For example, when using a 10 gpm pump the system requires a 2 gallon (total volume) tank. The tank sizing recommendations are field proven to prevent objectionable pressure drops on start-up and provide smooth operation for the majority of variable speed pump systems. For a 5 PSI Pressure Drop Set-up: Set the tank pressure, while tank is empty of water, to 20 psi below the desired system pressure setting. Ex. for a 50 psi system pressure, charge the tank to 30 psi. Pump and Piping For a 20 PSI Pressure Drop Set-up: WARNING Do not install any valves, flow control devices or filters between the pressure transducer and the pump. It is allowable to run branches off the pipe between the pump and transducer as long as no flow restricting devices are between the pump and transducer. Start with the tank pre-charge set 30 psi below the set point, this setting may need minor adjustment for optimum performance as all systems and piping are slightly different. NOTICE: The terms Transducer and Pressure Sensor are equal and interchangeable. 4 Splicing Drop Cable To Motor Leads The underwater connection where the drop cable connects to the motor wires must be done using a waterproof heat shrink kit. To make the connection, first strip the wires ½" and place the heat shrink tubes over the wires. Then,