Î Replace high pressure nozzle with
steam nozzle (Order Nr. 4.766-023,
see accessories).
Î Set the operating pressure on the appliance to the minimum value.
See Figure 6.
Î Set device switch to min. 212 °F/100 °C.
 Danger
Scalding danger!
We recommend the following cleaning temperatures:
– De-preserve, contaminations containing
strong fat contents
212 °F/100 °C-230 °F/110 °C
– De-frosting of surcharge substances,
partially facade cleaning
up to 284 °F/140 °C
After each operation
 Danger
Danger of scalding by hot water. After the
operation with hot water or steam, the device must be operated with openend gun
with cold water for at least two minutes.
After operation with detergent
Î Set dosing value for detergent to "0".
Î Set the appliance switch to "I".
Î Open the hand spray gun and rinse the
appliance for at least 1 minute.
Turn off the appliance.
Î Set the appliance switch to "0".
Î Shut off water supply.
Î Turn on pump shortly (appr. 5 seconds)
with device switch.
Î Pull main plug out of socket with dry
hands only.
Î Activate hand spray gun until device is
pressure less.
Î Secure hand spray gun, Figure 5 (A).
Î Remove water connection.
12 English
Î Lock in the steel pipe into the holder of
the appliance hood.
Î Roll up high pressure hose and electrical
conduit and hang them into the respective holders.
Device with hose drum:
Î Before rolling up, stretch out the high
pressure hose.
Î Turn the hand crank clockwise (Direction
of the arrow).
Note
Do not twist high pressure hose and electrical conduit.
몇 Warning
Frost will destroy the not completely water
drained device.
Î Store in a frost free area.
If the device is connected to a chimney, the
following must be observed:
몇 Warning
Threat of damage by penetrating cold air
through the chimney.
Î Disconnect device from chimney when
outside temperature drops below 32 °F/
0 °C.
If it is not possible to store frost free, shut
down device.
Shutdown
For longer work breaks or if a frost free storage is not possible:
Î Drain water.
Î Flush device with anti-freeze agent.
Î Empty detergent tank.
Dump water
Î Screw off water supply hose and high
pressure hose.
Î Screw off supply hose at boiler bottom
and drain heating spiral empty.
Î Operate device for max. 1 minute until
the pump and conduits are empty.
Device with hose drum:
Î Screw off both conduits at boiler bottom.