Download 532 IDL - De`Longhi
Transcript
sequences will be displayed in the following order: 1. The letter A (programme A) is displayed on the left, while the days being programmed appear in succession on the right, 1 Monday, 2 Tuesday, etc. 2. 00:00 then appears together with the mode icon, for example . This continues with the time and relative mode being displayed until 24:00 is reached. Each step is displayed for 3". 3. The procedure is repeated to display programmes B, C and D. This completes the reading and the normal display is restored. Programmes to which days have not been assigned are marked with an "0" and the times and modes are not displayed for these programmes. The sequence moves on directly to the following programme. When the user is viewing programming, pressing “+” moves on to the following programme and pressing “-” ends programming. 9.POWER FAILURE In the event of a blackout, the appliance is out of service and will reconnect when the power comes back on. All settings will be maintained without change. The clock stops during power failure. All programmes will therefore be run with a delay equal to the length of time without power unless the time is updated. 10. OVERHEAT PROTECTION The appliance is designed to transmit heat by convection and radiation. Covering the appliance partially or totally with wet or dry garments or other objects hampers this function. It also causes the appliance itself to overheat. The appliance is fitted with a safety device which disconnects it in the event of overheating. It starts up again automatically once the problem has been resolved. As well as the negative effect of individual episodes, repetition may cause damage or breakdown not covered by the guarantee. 11. ROUTINE MAINTENANCE No regular technical maintenance is required. It is sufficient to clean the appliance using a vacuum cleaner and soft brush. You can use a cloth moistened with water or neutral soap to remove stains. 12. TROUBLESHOOTING - Make sure the appliance is connected (ON). - Make sure there is electrical power to the appliance (LCD). - Make sure the temperature set on the thermostat is higher than room temperature. - If the appliance is in DOMO or mode, make sure it is not receiving a command to shut the appliance down. If this does not resolve the problem, contact the technical assistance service. 13. CLASS II APPLIANCES AND IP24 This is identified on the rating plate with the marks (Class II) and IP24 (Protected from water splashes). These appliances can be installed in any room, including in volume 2 of the bathroom. They should never under any circumstances be installed in volumes 0 and 1. See figure 6, always and when the appliance is protected by a high sensitivity 30 mA differential device. In the bathroom, locate the appliance in such a way that the controls cannot be touched by someone using the bath or shower. Figure 6 Shower Bath Vol 1 Vol 0 14 Vol 2 Vol 3 0,80m 2,40m Vol 1 Vol 0 Vol 2 0,80m Vol 3 2,40m