Download VISION 2
Transcript
VISION 2 RFF4000 can be used with Powerpak, TORNADO or Proflow powered respirator systems provided that the correct filter type is fitted. WEARING 1. Check that the facemask, inhale and exhale valves; and head harness are clean and undamaged. In such cases, ensure that this manual is read in conjunction with the following publications: Product Publication 2. Check that the filter(s) fitted is/are not clogged, saturated or time expired and is/are suitable for the hazards that may be encountered. Fit new filter(s) if necessary. Check that filter seal(s) is/are in place and is/are in good condition. Replace if necessary. Article No. Powerpak User Manual Filter Manual 1065558 1064883 Tornado User Manual Filter Manual 1070613 1070782 Proflow User Manual Filter Manual 009741 009752 3. Check that the exhale valve is clean and in good condition. Ensure that the valve flap is not distorted. 4. Hang the mask around your neck by the neckstrap, fully slacken the head harness and remove the filter cover(s). The neckstrap pin can be pressed into the hole at the top of the head harness to support the facemask in an upright attitude, keeping it free from dust and debris when the mask is not in use. Please contact our Customer Services Department if you require any further information. VISION 2 is easily dismantled for repair and servicing, requiring only a pozi-drive screwdriver to undo the front fitting. Servicing should only be carried out by trained, authorised personnel. 5. Hold the head harness with the thumbs inside the harness. Fit the chin into the chin-cup and pull the harness over the head. Gently tighten the harness straps; lower first, then the middle straps (if fitted) and finally the top strap. A good seal should be achieved without overtightening, which will cause the facemask seal to distort and cause discomfort. FILTERS The following filters are available for use with VISION 2: Code Filter Type Standard EC200R A2 EN 14387 : 2004 EC201R B2 EN 14387 : 2004 EC203R K2 EN 14387 : 2004 EC213R ABEK2 EN 14387 : 2004 EC219R AX EN 14387 : 2004 EC220R A2 P3 EN 14387 : 2004 EC221R B2 P3 EN 14387 : 2004 EC222R E2 P3 EN 14387 : 2004 EC223R K2 P3 EN 14387 : 2004 EC230R A2 B2 E1 P3 EN 14387 : 2004 EC233R ABEK2 P3 EN 14387 : 2004 EC238R AE1Hg P3 EN 14387 : 2004 EC239R AXP3 EN 14387 : 2004 EC251R P3 EN 143 : 2000 6. Check the mask seal to the face by covering the filter inlet(s) with a hand or the filter blanking cover and inhaling. The mask should pull onto the face. Hold your breath for 10 seconds and check that the mask seal is maintained over the 10 second period. If the seal fails, indicated by the mask pulling away from the face, check that the filter(s) is/are properly fitted and adjust the mask seal to the face, then repeat the test. If it fails a second time, the mask should be serviced. WARNING: If the mask does not seal correctly after servicing, DO NOT use. 2