Download Airless Paint Sprayers
Transcript
Operating Instructions and Assembly Instructions Airless Paint Sprayers General Safety Information (Continued) 4. Do not smoke or eat when spraying paint, insecticides, or other flammable substances. 5. Always work in a clean environment. To avoid injury and damage to the workpiece, do not aim the spray gun at any dust or debris. 6. When spraying and cleaning, always follow the instructions and safety precautions provided by the material manufacturer (Refer to MSDS). ! DANGER ELECTRICAL SHOCK HAZARD: ● Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and in the United States, the Occupational Safety and Health Act (OSHA). ● This product requires a grounded 120V, 15 Amp circuit (See Figure 1). ● Do not use a power cord adapter with this equipment. ● Never leave equipment pressurized while unattended. ● If using an extension cord, use only grounded three wire extension cords that are in good condition. ● Do not clean spray tip while it is attached to the spray gun. Remove spray tip from gun to clean tip guard. ● Check with a qualified electrician or service person if the grounding instructions are not completely understood or you are in doubt as to whether the equipment is properly grounded. APPROPRIATE EXTENSION CORD GAUGE FOR GIVEN LENGTHS Length of Cord Gauge 25’ 14 25-50’ 12 50-100’ 10 ! WARNING SKIN INJECTION HAZARD: ● High pressure spray can inject toxins into blood stream. If injection occurs, seek emergency medical treatment. ! WARNING Grounding Pin TEST RESET Figure 1 - Grounding NOTE: Applies to 120V countries only. ● If the power receptacles available will not fit this equipment’s power cord, then have an appropriate power receptacle installed by a certified electrician. Use a face mask/respirator and protective clothing when spraying. Always spray in a well ventilated area to prevent health and fire hazards. Refer to Material Safety Data Sheets (MSDS) of spray material for details. ● Never try to stop leaks with any part of your body. ● This system is capable of producing 3000 psi. Use only Campbell Hausfeld replacement parts rated at 3000 psi or higher. ● Only qualified electricians or service personnel should perform maintenance on the electrical components of this equipment. ● Never spray without tip guard. ● Do not modify any of the electrical components of this equipment. ● Always engage trigger lock when not spraying. ● Ensure trigger lock is functioning properly. See Maintenance section for inspection procedures. ● Do not remove spray tip while cleaning pump. ● Ensure tightness of high pressure connections. ● Do not use pliers to tighten or loosen high pressure connections. ● Motor is equipped with an automatic thermal overload. Motor will restart without warning, after cooling. Never aim or spray at yourself or anyone else or serious injury could occur. ! WARNING Before servicing or resting: 1. Turn the Prime/Spray Control to the PRIME position. 2. Turn the pressure control to LOW PRESSURE/HYDRAULIC BLEEDING position. 3. Turn power switch to OFF position. 4. With gun pointed in a safe direction, pull the gun trigger, with the trigger lock disengaged. 5. Engage trigger lock. ● Simply turning off the pump motor will not relieve pressure from system. The above procedure MUST be followed. ! WARNING FIRE OR EXPLOSION HAZARD: ● Do not use solvents with flash points less than 70°F (21°C) to clean this equipment (examples of acceptable cleaning solvents are water, mineral spirits, lacquer thinner, Xylene and high flash napha. A partial example list of unacceptable cleaning solvents are low flash napha, mek, acetone, alcohol and toluene). www.chpower.com 3