Download ACCU-TURN 1400
Transcript
Trouble shooting Wheel does not spin automatically. 1. Lowering the switch guard does not activate a wheel spin. • Check if the switch is mechanically activated by lowering the guard. 2. Electrical malfunction. • Call Accu Service. Gauge arm input differs from rim dimension stated on rim or tire. 1. Did you position the gauge arm correctly? • Refer to Chapter 5.3.1. 2. Check the diameter of the spot on the rim where the diameter has been measured. • If not identical, proceed with step 4. 3. A calibration is required. • Have the gauge arm calibrated. Balancing results are inconsistent. 1. The balancer may not be installed properly. • Make sure the unit rests on its 3 feet only. • Make sure the floor is not relaying shocks (e.g. from passing trucks) to the unit. 2. The wheel may be mounted incorrectly. • Check the stub shaft, cones and adapters for play. • Use an adapter plate to eliminate play. • Perform a Measuring Unit calibration. 3. The electronics are faulty. • Call Accu Service. A mode, display segment or indicator is continuously shown on the display. 1. A “brown out” (power dip) may have occurred. • Switch off the unit. Wait for 20 seconds, switch on the unit. • Call Accu Service. Operator’s Manual 62 ACCU 1400