Installation SN2008/IR Rough-In Dimensions for Supplies and Drain Notes (mm) Key Maximum flow rate required to washfountain is 1.5 GPM. Size supply lines accordingly. Supplies from Below: Stub up 2-1/2" (64). Supplies from Above: Supplies must be located on centers of dimensions shown to pass through washfountain shroud and sprayhead. 1/2" Supply: Nominal Copper Tube 1-1/2" NPT Drain Stub up 3" (76) from Floor Conduit Location (Recommended) Drain through floor: Stub up 3" (76). Supplies from Below or Through Wall Supplies from Above Type B Centrally rising vent (P-Trap furnished with unit.) Use for units with paper towel Dispensers and/or shrouds. Type A Off-line vent (P-Trap supplied by Installer.) Type H Centrally rising vent (P-Trap furnished with unit.) Use for units with paper towel Dispensers and/or shrouds. Type O Off-line vent (P-Trap supplied by Installer.) Top View Top View 4-1/2" 4-1/2" (114) (114) H C Type H 3-1/4" (83) 4" (102) Type B 27/32" (21) H 4" (102) 5" (127) 27/32" (21) Type A C 1-3/16" (30) 5" (127) Type O Remote mounting of transformers with 24VAC electrical supply to washfountain is recommended. UPC and IPC restrict the vertical distance from the fixture outlet to the trap weir to not more than 24" (610). Check state and local codes for variances. 4 12/04/2012 Bradley •215-1069Rev.J;ECN12-00-004