Unit description
Ingeteam
10TL M
12.5TL M
15TL M
20TL M
10.3 ~ 13.4 kWp
12.9 ~ 16.8 kWp
15.5 ~ 20.1 kWp
20.6 ~ 26.8 kWp
1000 V
1000 V
1000 V
1000 V
200 ~ 820 V
200 ~ 820 V
200 ~ 820 V
200 ~ 820 V
DC input
Recommended power range of PV array (1)
Maximum input voltage (2)
Voltage range MPP1 (3)
Voltage range MPP2 (3)
200 ~ 820 V
200 ~ 820 V
200 ~ 820 V
200 ~ 820 V
Operating voltage range
200 ~ 1000 V
200 ~ 1000 V
200 ~ 1000 V
200 ~ 1000 V
260 V
325 V
310 V
415 V
23 / 23 A
23 / 23 A
23 / 23 A
23 / 23 A
0 A rms
0 A rms
0 A rms
0 A rms
2
2
2
2
Number of strings versions P and P+
(input 1 / input 2)
1/1
1/1
1/1
1/1
Number of strings versions S, S+ and S++
(input 1 / input 2)
2/2
2/2
3/2
3/2
20 / 20 A
20 / 20 A
30 / 20 A
30 / 20 A
12 A
12 A
12 A
12 A
Minimum voltage for Pnom
Maximum short circuit current
(input 1 / input 2)
Maximum inverter backfeed current to the
array
MPPT
Maximum input current
(input 1 / input 2)
Maximum input current per string
AC output
Nominal power (up to 45 ºC)
10 kW
12.5 kW
15 kW
20 kW
Maximum continuous power
10 kW
12.5 kW
15 kW
20 kW
Max. temperature for nominal power (4)
55 ºC
55 ºC
55 ºC
55 ºC
Maximum current
15 A
19 A
22 A
29 A
Maximum transient current
15 A
19 A
22 A
Maximum output fault current
Maximum output overcurrent protection
< 22 A rms (60 ms)
29 A
< 33 A rms (60 ms)
22 A rms
22 A rms
22 A rms
Rated voltage
400 V
400 V
400 V
400 V
Voltage range
277 ~ 528 V
277 ~ 528 V
277 ~ 528 V
277 ~ 528 V
50 / 60 Hz
50 / 60 Hz
50 / 60 Hz
50 / 60 Hz
1
1
1
1
Yes. Smax = 10 kVA
Yes. Smax = 12.5 kVA
Yes. Smax = 15 kVA
Yes. Smax = 20 kVA
<3%
<3%
<3%
<3%
Nominal frequency
Cosine of Phi
Adjustable cosine of phi
THD
33 A rms
Performance
Maximum efficiency
98.5 %
98.5 %
98.5 %
98.5 %
Euroefficiency
98.3 %
98.3 %
98.4 %
98.3 %
Air flow
300 m3/h
300 m3/h
300 m3/h
300 m3/h
Weight
60 kg
60 kg
60 kg
60 kg
General data
Cooling system
Forced ventilation
Measurements (height x width x depth)
Stand-by current (5)
Nocturnal current
Operating temperature
Relative humidity (without condensation)
Protection rating
Markings
730 x 700 x 250 mm
< 10 W
< 10 W
< 10 W
1W
1W
1W
< 10 W
1W
–20 ~ +65 ºC
–20 ~ +65 ºC
–20 ~ +65 ºC
–20 ~ +65 ºC
0 ~ 95 %
0 ~ 95 %
0 ~ 95 %
0 ~ 95 %
IP65
IP65
IP65
IP65
CE
EMC and safety regulations
EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, EN
62109-1, EN 62109-2, IEC62103, EN 50178, FCC Part 15, AS3100
Grid connection regulations
RD1699/2011, DIN V VDE V 0126-1-1, EN 50438, CEI 0-21, VDE-AR-N 4105:2011-08, G59/2,
G83/2 (6), P.O.12.3, AS4777.2, AS4777.3, IEC 62116, IEC 61727, UNE 206007-1, ABNT NBR 16149,
ABNT NBR 16150, South African Grid code, Chilean Grid Code, Romanian Grid Code, Ecuadorian
Grid Code, Peruvian Grid code, IEEE 929, Thailand MEA & PEA requirements
(1)
Depending on the type of installation and geographical location. (2) Never exceed this value. Consider the voltage increase of the panels ‘Voc’ at low
temperatures. (3) The output power will be determined by the tension and current configuration selected at each input. (4) For each ºC of increase, the
output power is reduced by 1.8 %. (5) Current from PV array. (6) Only for inverters with outputs up to 16 A.