9 Installing BYPASS Module (BPM) Kit content • 1x BPM assembly • 1x bracket "A" • 2x bracket "B" • 10x Screws • 1x black extension wire* • 1x red extentson wire* Bracket "A" Bracket "B" * Only used when electrical box is reversed Figure 1 Bracket "B" Installed Figure 2 Bracket "A Installed Figure 3 BPM Tilted Figure 4 BPM Fastening 1.Loosely fasten both brackets “B” to cabinet using screws in the pilot holes (Fig. 1). Don’t drive the screw all the way; leave about ¼” of thread for the step 4. 2.Using the same screw already on the unit, assemble bracket “A” on the cabinet (Fig. 2). 3.Install BPM by tilting it (Fig. 3) so that the hole on the mounting bracket “A” lines up with the pilot hole on top of the BPM. Secure it with the fastener and release the BPM. The tilting will enable the hole to line up properly and will compress the gasket once released. 4.Assemble the remaining fasteners to secure the BPM (Fig. 4). Continue to tighten the fasteners holding the bracket “B” to cabinet in order to compress the gasket between the BPM and the cabinet (Fig. 5). Figure 6 Insert damper motor wires through bushing Figure 5 Bracket "B" tightened Figure 7 HCE Controller, showing "N.O." terminal location and "C" terminal location 5.Next route the damper motor wires through the plastic bushing (Fig.6) of the electrical box and run the wires to the HCE controller on the terminal marked “N.O.” in the field marked “DAMPER” and on the terminal marked “C” in the field marked “24VAC”. (Fig. 7) fantech