AMPS
START
AMPS
WATTS
KWH/24HRS
7,1
32
1300
27,6
3
18
1400
28,0
10
66
2400
50
5,5
14
11
28
4800
105
MC 16 SHORT A - 230 V
MC 16 SHORT W - 230 V
MC 16 SHORT A - 400 V
MC 16 SHORT W - 400 V
MC 46 A - 230 V
MC 46 W - 230 V
MC 46 A - 400 V
MC 46 W - 400 V
MC 1210 A - 400 V
REFR. CHARGE SUCT. PRESS.
R404a
END. FREEZE
580 gr
450 gr
580 gr
450 gr
1300 gr
700 gr
1300 gr
700 gr
2 x 1300 gr
2 x 700 gr
MC 1210 W - 400 V
DISCHARGE
PRESSURE
16 ÷ 18 bar
17 bar
1,6 ÷ 1,7 bar
16 ÷ 18 bar
17 bar
16 ÷ 18 bar
17 bar
1,6 ÷ 1,7 bar
16 ÷ 18 bar
17 bar
13 ÷ 14 bar
13,5 ÷ 14,5 bar
2,5 bar
14 bar
DIP SWITCH FACTORY SETTING COMBINATIONS (PER MODEL AND VERSION)
COMBINAISON DES COMMUTATEURS NUMERIQUES DU DIP SWITCH POUR MODELES ET VERSIONS
REGOLAZIONE TASTI DIP SWITCH PER MODELLO E VERSIONE
FREEZING CYCLE
CYCLE DE CONGÉLATION
CICLO CONGELAMENTO
1
2
3
4
DIP SWITCH
MCS 16 A
MCS 16 W
MCM 16 A
MCM 16 W
MCL 16 A
MCL 16 W
MCS 46 A
MCS 46 W
MCM 46-1210 A
MCM 46-1210 W
MCL 46-1210 A
MCL 46-1210 W
MCXL 46 W
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
TIMED PORTION FREEZING CYCLE
TEMPS PHASE TEMPORISÉE CONGELATION
TEMPI FASE TEMPORIZZATA CONGELAMENTO
1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
2
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
7
8
3
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
4
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
ADDITIONAL DEFROST TIME
TEMPS AJOUTÉS
TEMPI AGG. SCONGELAMENTO
ON
ON
0
OFF
ON
30 sec.
ON
OFF
60 sec.
7
OFF
1 min.
3 min.
5 min.
7 min.
9 min.
11 min.
13 min.
15 min.
17 min.
19 min.
21 min.
23 min.
25 min.
DEFROST CYCLE
CYCLE DE DÉMOULAGE
CICLO SBRINAMENTO
5
6
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
LED
STATUS
ON STEADY
FIXE
FISSO
WATER PUMP OFF DURING DEFROST
POMPE A L’ARRÊT PEND. DEGIVRAGE
POMPA ACQUA DURANTE SBRINAMENTO
7
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
8
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
9
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
AIR/EAU
ARIA/ACQUA
10
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
REASON WHY - SIGNIFICATION - SIGNIFICATO
FREEZING CYCLE
EN RÉFRIGÉRATION
IN CONGELAMENTO
BLINKING
60 MINUTES DELAY AT START UP JUMPER J3 OUT
CLIGNOTANT 60 MINUTES DE RETARD AU DEMARRAGE - CAVALIER J3 OUVERTE
LAMPEGGIANTE 60 MINUTI RITARDO PARTENZA - CONTATTI J3 APERTI
ON STEADY
FIXE
FISSO
TOO HI DISCHARGE PRESSURE/TEMP.
COUPURE HP
FERMATA ALTA TEMP. CONDENSAZIONE
BLINKING
TOO HI EVAP. TEMP. (> 0°C) AFTER 15’ FROM START UP
CLIGNOTANT COUPURE BP ( > 0°C LU PAR LA SONDE EVAP. NON ATTEINTE APRES 15’ FONCT.)
LAMPEGGIANTE TEMP. EVAP. > 0°C DOPO 15’ DA INIZIO CONGELAMENTO
ON STEADY
FIXE
FISSO
UNIT OFF AT BIN FULL
CABINE PLEINE
CONTENITORE PIENO
BLINKING SLOW I/R BEAM CUTTED
CLIGNOTANT LENT FAISCEAU INFRA ROUGE CELLULE NIVEAU GLACE INTERROMPU
LAMPEGG. LENTO RAGGIO INFRAROSSO INTERROTTO
BLINKING FAST I/R ON AFTER TRIP OFF AT BIN FULL
CLIGNOTANT RAPIDE FAISCEAU INFRA ROUGE CELLULE NIVEAU GLACE ETABLI
LAMPEGG. VELOCE RAGGIO INFRAROSSO RIPRISTINATO DOPO FERMATA A CONT. PIENO
ON STEADY
FIXE
FISSO
I/R CALIBRATION DONE
CALIBRATION FAISCEAU INFRA ROUGE CELL. NIVEAU GLACE REALISÉ
CALIBRAZIONE RAGGIO INFRAROSSO EFFETTUATA
BLINKING
UNIT IN CLEANING MODE OR TRIPPING OFF AFTER TEST - JUMPER TEST IN
CLIGNOTANT MACHINE EN MODE DETARTRAGE OU ARRÊTE APRES LE TEST - CAVALIER TEST FERMÉ
LAMPEGGIANTE MACCHINA NELLA FASE LAVAGGIO O FERMA DOPO IL TEST - PONTICELLO TEST CHIUSO
ON STEADY
FIXE
FISSO
CONDENSER SENSOR OUT OF ORDER
SONDE CONDENSEUR HS
SONDA CONDENSATORE MALFUNZIONANTE
BLINKING
EVAPORATOR SENSOR OUT OF ORDER
CLIGNOTANT SONDE EVAPORATEURS HS
LAMPEGGIANTE SONDA EVAPORATORE MALFUNZIONANTE
BLINKING ALTERNATIV. I/R SENSOR OUT OF ORDER
CLIGNOTANT ALTERNÉ SONDE INFRA ROUGE CELLULE NIVEAU GLACE HS
LAMPEGGIO ALTERN. SONDA ALL’INFRAROSSO LIVELLO GHIACCIO MALFUNZIONANTE
8
OFF
15/30"
PUSH
PUSH > 5” DURING WATER FILLING TO MOVE THE UNIT INTO FREEZING
PUSH > 5” DURING FREEZING TO MOVE THE UNIT INTO DEFROST
PUSH > 5” DURING DEFROST TO MOVE THE UNIT INTO FREEZING
PUSH 2” ÷ 5” DURING WATER FILLING TO MOVE THE UNIT INTO CLEANING
PUSH DURING THE 60 MIN START UP DELAY TIME TO BY-PASS IT