Download spiroline mp
Transcript
5after use Users of the breathing apparatus 1a. Close the cylinder valve on the bail-out set/breathing apparatus and take off the facemask as described in the instructions for the bail-out set/breathing apparatus. 1b. Disconnect the air supply hose from the bail-out set/breathing apparatus. 1c. Take off the unit and vent as described in the instructions for the bail-out set/ breathing apparatus. Users of the Spiroline belt 1a. Take off the facemask as described in the instructions for the facemask. 1b. Disconnect the air supply hose from the Spiroline belt. 1c. Open the waist belt buckle by pressing it in the middle. 1d. Take 1e. off the belt. Activate the safety pressure on the facemask to vent. The unit must be cleaned after every use, as described in Section 6. If cleaning is done directly after use, this must be done before steps 2-4 below. 2. 3. 4. 10 Close the valves of the air source. Open the vent valves on the regulator units in the TRS unit. Close the vent valves, disconnect the adapter hoses and mount them in the box of the TRS unit. Disconnect the air supply hose.