Download ES01 ES02 - Oriental Motor
Transcript
HP-5018-8 ã¹ããŒãã³ã³ãããŒã© ES01 ES02 åæ±èª¬ææž English version follows Japanese version. ããã ã䜿ãã«ãªãåã« âŠâŠâŠâŠâŠâŠâŠâŠ 2 ããŒãž å®å šäžã®ã泚æ âŠâŠâŠâŠâŠâŠâŠâŠâŠ 3 ããŒãž èš çœ®âŠâŠâŠâŠâŠâŠâŠâŠâŠâŠâŠâŠâŠ 5 ããŒãž æ¥ç¶ã»é転 âŠâŠâŠâŠâŠâŠâŠâŠâŠâŠâŠ 8 ããŒãž ç¹ æ€ âŠâŠâŠâŠâŠâŠâŠâŠâŠâŠâŠâŠ16 ããŒãž æ éã®èšºæãšåŠçœ® âŠâŠâŠâŠâŠâŠâŠ 17ããŒãž ãè²·ãäžãããã ãããããšãããããŸãã ãã®åæ±èª¬ææžã«ã¯ã補åã®åãæ±ããããå®å šäžã®æ³šæäºé ã瀺ããŠããŸãã â åæ±èª¬ææžããããèªã¿ã«ãªãã補åãå®å šã«ã䜿ããã ããã â ãèªã¿ã«ãªã£ãããšã¯ããã€ã§ãèŠããããšããã«å¿ ãä¿ç®¡ããŠãã ããã ã䜿ãã«ãªãåã« ã¯ããã« ãã®åæ±èª¬ææžã¯ãã¹ããŒãã³ã³ãããŒã©ES01ãES02ã«ã€ããŠèª¬æããŸããã¹ããŒãã³ã³ãããŒã© ã¯ãã¯ããŒãºãã«ãŒãåã®äœçžå¶åŸ¡ã§ãå°çšã®ã¹ããŒãã³ã³ãããŒã«ã¢ãŒã¿ãŒãé§å(é床å¶åŸ¡)ã ãããšã®ã¿ãç®çãšããŠããŸããé©çšã¢ãŒã¿ãŒã¯ãã¯ãŒã«ãKã·ãªãŒãºãšVã·ãªãŒãºã®ã¹ããŒãã³ã³ ãããŒã«ã¢ãŒã¿ãŒ(6WâŒ90W)ã§ããã¢ãŒã¿ãŒã®åæ±èª¬ææžãåãããŠã芧ãã ããã 補åã®åãæ±ãã¯ã黿°ããã³æ©æ¢°å·¥åŠã®å°éç¥èãæã€æè³æ Œè ãè¡ãªã£ãŠãã ããã ã䜿ãã«ãªãåã«ã ãå®å šäžã®ã泚æãããããèªã¿ã®ãããæ£ããã䜿ããã ããã 補åå éšã®ç¹æ€ãä¿®çãå¿ èŠãªãšãã¯ããè²·ãäžãã«ãªã£ãæ¯åºã»å¶æ¥æã«ãé£çµ¡ãã ããã ãã®è£œåã¯ãäžè¬çãªç£æ¥æ©åšã®æ©åšçµã¿èŸŒã¿çšãšããŠèšèšã»è£œé ãããŠããŸãããã®ä»ã®çšé ã«ã¯äœ¿çšããªãã§ãã ããããã®èŠåãç¡èŠããçµæçããæå®³ã®è£åã«ã€ããŠã¯ãåœç€Ÿã¯äžå ãã®è²¬ä»»ãè² ããŸããã®ã§ãããããããäºæ¿ãã ããã èŠæ Œã»CEããŒãã³ã° ãã®è£œåã¯ãULèŠæ ŒãCSAèŠæ Œã®èªå®ãååŸããENèŠæ Œã«åºã¥ããŠCEããŒãã³ã°(äœé»å§æä»€ã EMCæä»€)ã貌ä»ããŠããŸãã â é©çšèŠæ Œ é©çšèŠæ Œ UL508 CSA C.22.2 No.14 EN50178â EN60950-1 EN61000-6-4 EN61000-6-2 èªå®æ©é¢ èŠæ Œãã¡ã€ã«No. UL File No. E91291 â â â EN50178ã§èŠæ±ãããéé»å§ä¿è·è©Šéšã¯è¡ãªã£ãŠããŸãããæçµè£œåãšã㊠çµã¿èŸŒãã ç¶æ ã§è©ŠéšããŠãã ããã â èšçœ®æ¡ä»¶ (ENèŠæ Œ) æ©åšçµèŸŒ(ã¯ã©ã¹â ¡æ©åš)ãéé»å§ã«ããŽãªãŒâ ¡ãæ±æåºŠ2ãIP20 â äœé»å§æä»€ ãã®è£œåã¯ãæ©åšçµã¿èŸŒã¿åã§ãã â EMCæä»€ ãã®è£œåã¯ã7ããŒãžã®ãã¢ãŒã¿ãŒãã¹ããŒãã³ã³ãããŒã©ã®èšçœ®ã»é ç·äŸãã§EMC枬å®ãè¡ãªã£ãŠ ããŸããå¿ ã5ããŒãžã®ãEMCæä»€ã«å¯Ÿããèšçœ®ã»é ç·æ¹æ³ããã芧ã«ãªããã客æ§ã®è£ 眮ã«çµ ã¿èŸŒãã ç¶æ ã§ãEMC枬å®ãè¡ãªã£ãŠãã ããã â æå®³ç©è³ª RoHSïŒEUæä»€2002/95/EC 27Jan.2003ïŒé©å 2 å®å šäžã®ã泚æ ããã«ç€ºããæ³šæäºé ã¯ã補åãå®å šã«æ£ããã䜿ãããã ããã客æ§ãä»ã®äººã ãžã®å±å®³ã æå·ãæªç¶ã«é²æ¢ããããã®ãã®ã§ããå 容ãããçè§£ããŠããã䜿ããã ããã èŠå ãã®èŠåäºé ã«åããåãæ± ãããããšãæ»äº¡ãŸãã¯éå·ã è² ãå Žåãããå 容ã瀺ã㊠ããŸãã æ³šæ ãã®æ³šæäºé ã«åããåãæ± ãããããšãå·å®³ãè² ããŸã㯠ç©çæå®³ãçºçããå Žåãã ãå 容ã瀺ããŠããŸãã éèŠ è£œåãæ£ããã䜿ãããã ãã ãã«ãã客æ§ã«å¿ ãå®ã£ãŠã ãã ãããäºé ãæ¬æäžã®é¢ é£ããåãæ±ãé ç®ã«èšèŒã ãŠããŸãã èŠå å š è¬ â ççºæ§é°å²æ°ãåŒç«æ§ã¬ã¹ã®é°å²æ°ãè é£ æ§ã®é°å²æ°ãæ°Žã®ãããå Žæãå¯çç©ã®ã ã°ã§ã¯äœ¿çšããªãã§ãã ããã ç«çœã»æé»ã»ããã®åå ã«ãªããŸãã â èšçœ®ãæ¥ç¶ãéè»¢ã»æäœãç¹æ€ã»æ é蚺æ ã® äœæ¥ã¯ã黿°ããã³æ©æ¢°å·¥åŠã®å°éç¥èã æã€æè³æ Œè ãè¡ãªã£ãŠãã ããã ç«çœã»æé»ã»ããã®åå ã«ãªããŸãã â éé»ç¶æ ã§ç§»åãèšçœ®ãæ¥ç¶ãç¹æ€ã®äœæ¥ ãããªãã§ãã ããã黿ºãåã£ãŠããäœæ¥ ããŠãã ããã æé»ã®åå ã«ãªããŸãã æ¥ ç¶ â ã¹ããŒãã³ã³ãããŒã©ã®é»æºå ¥åé»å§ã¯ãå® æ Œå€ãå¿ ãå®ã£ãŠãã ããã ç«çœã»æé»ã®åå ã«ãªããŸãã â æ¥ç¶ã¯æ¥ç¶å³ã«ããšã¥ãã確å®ã«è¡ãªã£ãŠ ãã ããã ç«çœã»æé»ã®åå ã«ãªããŸãã â ã±ãŒãã«ãç¡çã«æ²ããããåŒã£åŒµã£ããã ã¯ãã¿èŸŒãã ãããªãã§ãã ããã ç«çœã»æé»ã®åå ã«ãªããŸãã â æ¥ç¶çµäºåŸã¯ãå¿ ãã¹ããŒãã³ã³ãããŒã©ã® ã«ããŒãåãä»ããŠãã ããã æé»ã®åå ã«ãªããŸãã â å€éšé床èšå®åšã®æ¥ç¶ç«¯åã¯çµ¶çžåŠçã㊠ãã ããã æé»ã®åå ã«ãªããŸãã â ã¹ããŒãã³ã³ãããŒã©ã«ã¯é黿µä¿è·ã®ã㥠ãŒãºãå èµããŠããŸããã黿ºãšã®æ¥ç¶ã« ã¯é黿µä¿è·è£ 眮 (ãã¥ãŒãºãªã© )ãåãä» ããŠãã ããã ç«çœã®åå ã«ãªããŸãã é 転 âåé»ãããšãã¯ãã¹ããŒãã³ã³ãããŒã©ã®é» æºãåã£ãŠãã ããã åé»åŸ©æ§æã«ã¢ãŒã¿ãŒãçªç¶èµ·åããŠãããã» è£ çœ®ç Žæã®åå ã«ãªããŸãã ä¿å®ã»ç¹æ€ â黿ºãåã£ãçŽåŸ (1å以å )ã¯ãã¹ããŒãã³ ã³ãããŒã©ã®ã¢ãŒã¿ãŒã»é»æºæ¥ç¶ç«¯åå°ã«è§Š ããªãã§ãã ããã æé»ã®åå ã«ãªããŸãã åè§£ã»æ¹é â ã¹ããŒãã³ã³ãããŒã©ãåè§£ã»æ¹é ããªãã§ ãã ããã æé»ã»ããã®åå ã«ãªããŸãã 3 泚æ å š è¬ âã¹ããŒãã³ã³ãããŒã©ã®ä»æ§å€ãè¶ ããŠäœ¿çš ããªãã§ãã ããã æé»ã»ããã»è£ çœ®ç Žæã®åå ã«ãªããŸãã èš çœ® âã¹ããŒãã³ã³ãããŒã©ã®åšå²ã«ã¯ãå¯çç©ã 眮ããªãã§ãã ããã ç«çœã»ããã©ã®åå ã«ãªããŸãã é 転 âã¹ããŒãã³ã³ãããŒã©ãšã¢ãŒã¿ãŒã¯ãæå®ã ããçµã¿åããã§äœ¿çšããŠãã ããã ç«çœã®åå ã«ãªããŸãã âè£ çœ®ã®æ éãåäœã®ç°åžžãçºçãããšãã¯ã è£ çœ®å šäœãå®å šãªæ¹åãžã¯ãããããéåžž åæ¢è£ çœ®ããŸãã¯éåžžåæ¢åè·¯ãå€éšã«èš 眮ããŠãã ããã ããã®åå ã«ãªããŸãã âã¹ããŒãã³ã³ãããŒã©ã«é»æºãæå ¥ãããšã ã¯ãã¹ããŒãã³ã³ãããŒã©ã®é転 / åæ¢å ¥å ãON(忢)ã«ããŠããæå ¥ããŠãã ããã ã¢ãŒã¿ãŒãèµ·åããããã»è£ çœ®ç Žæã®åå ã« ãªããŸãã âç°åžžãçºçãããšãã¯ããã ã¡ã«é転ã忢 ããŠãã¹ããŒãã³ã³ãããŒã©ã®é»æºãåã£ãŠ ãã ããã ç«çœã»æé»ã»ããã®åå ã«ãªããŸãã âã¹ããŒãã³ã³ãããŒã©ã®å éšé床èšå®åšãã¹ ããŒã¹ã¿ãŒãæéèšå®åšãã¹ããŒããŠã³æé èšå®åšã¯ãçµ¶çžãããã¹ã¯ãªã¥ãŒãã©ã€ã㧠調æŽããŠãã ããã æé»ã®åå ã«ãªããŸãã å» æ£ â ã¹ããŒãã³ã³ãããŒã©ã廿£ãããšãã¯ãã§ ããã ãåè§£ããç£æ¥å»æ£ç©ãšããŠåŠçã㊠ãã ããã 4 â èŠå衚瀺ã«ã€ã㊠ã¹ããŒãã³ã³ãããŒã©ã®ã«ããŒã«ãèŠåã衚瀺ã ãŠããŸããã¹ããŒãã³ã³ãããŒã©ãåãæ±ããšã ã¯ãå¿ ããã®è¡šç€ºå 容ãå®ã£ãŠãã ããã èš çœ® èšçœ®å Žæ ã¹ããŒãã³ã³ãããŒã©ã¯æ©åšçµã¿èŸŒã¿çšã«èšèšã補é ãããŠããŸãã 颚éãããããç¹æ€ã容æãªæ¬¡ã®ãããªå Žæã«èšçœ®ããŠãã ããã åšå²æž©åºŠã40âãè¶ ãããšãã¯ãææ°æ¡ä»¶ãèŠçŽããŠãã ããã âå±å ã«èšçœ®ãããçäœå (ææ°å£ãèšããŠãã ãã) â䜿çšåšå²æž©åºŠ 0ââŒïŒ40â (åçµããªãããš) 85%ä»¥äž (çµé²ããªãããš) âççºæ§é°å²æ°ã§ãªããšãããããã³æå®³ãªã¬ã¹(ç¡«åã¬ã¹ãªã©)ãæ¶²äœããªããšãã âé£ç¶çãªæ¯åããé床ã®è¡æãå ãããªããšãã âæº¶æ¥æ©ãååæ©åšãªã©ã«ããé»ç£ãã€ãºãå°ãªããšãã âæŸå°æ§ç©è³ªãç£å Žããªããç空ã§ãªããšãã âæšé«1000mä»¥äž â䜿çšåšå²æ¹¿åºŠ èšçœ®æ¹æ³ â ããæ¢ãã§ã®èšçœ® ã¹ããŒãã³ã³ãããŒã©ã®2ãæã®åä»ç©Žã䜿çšããŠã2æ¬ã®ãã(ïŒ4ïŒä»å±ããŠããŸãã)ã§åºå®ã ãŸãã ç· ãä»ããã«ã¯ïŒ0.7Nm â DINã¬ãŒã«ãžã®èšçœ® ã¬ãŒã«å¹ 35 mmã®DINã¬ãŒã«ã䜿çšããŠãã ããã åãå€ããšãã¯ãDINã¬ããŒã10âŒ20NçšåºŠã®åã§åŒããŠãã ããã EMCæä»€ã«é©åãããèšçœ®ã»é ç·æ¹æ³ â EMCæä»€ (89/336/EEC, 92/31/EEC) æçµçãªè£ 眮ã®EMCãžã®é©åæ§ã¯ãã客æ§ãèªèº«ã§è£ 眮ã®EMC詊éšãè¡ãªã£ãŠç¢ºèªããŠãã ããã é©çšèŠæ Œ EMI Emission Tests Radiated Emission Test Conducted Emission Test EN61000-6-4 EN55011 EN55011 Immunity Tests Radiation Field Immunity Test Electrostatic Discharge Immunity Test Fast Transient/Burst Immunity Test Conductive Noise Immunity Test Surge Immunity Test Voltage Dip Immunity Test Voltage Interruption Immunity Test EN61000-6-2 IEC61000-4-3 IEC61000-4-2 IEC61000-4-4 IEC61000-4-6 IEC61000-4-5 IEC61000-4-11 IEC61000-4-11 EMS 5 â èšçœ®ã»é ç·æ¹æ³ â A Cã©ã€ã³ãã£ã«ã¿ã®æ¥ç¶ ã¹ããŒãã³ã³ãããŒã©ããçºçãããã€ãºå¯Ÿççšã«ãACå ¥åã©ã€ã³ã«ã¯äžè¡šã®ACã©ã€ã³ãã£ã«ã¿ãŸ ãã¯çžåœåãæ¥ç¶ããŠãã ããã TDKæ ªåŒäŒç€Ÿ EPCOS AG Schaffner EMC Tyco Electronics CORCOM ZAG2210-11S B84112-B-B110 FN2330Y-10-06 FN2310X-10-06 10ESK1 ACã©ã€ã³ãã£ã«ã¿ã¯ãã§ããã ãã¹ããŒãã³ã³ãããŒã©ã®è¿ãã«åãä»ããå ¥åã±ãŒãã«ãšåºåã±ãŒã ã«ã¯çäœã®ç€é¢ããæµ®ããªãããã«ãã±ãŒãã«ã¯ã©ã³ããªã©ã䜿çšããŠç¢ºå®ã«åºå®ããŠãã ããã ACã©ã€ã³ãã£ã«ã¿ã®æ¥å°ç«¯åã¯ãã§ããã ã倪ããæçè·é¢ã§æ¥å°ãã€ã³ãã«æ¥å°ããŠãã ããã ãªããA Cå ¥ååŽã®ã±ãŒãã«( AWG18ïŒ0.75 mm 2 ä»¥äž )ãšA Cã©ã€ã³ãã£ã«ã¿ã®åºåã±ãŒãã« (AWG18ïŒ0.75mm2以äž)ã¯äžŠè¡ããŠé ç·ããªãã§ãã ãããACã©ã€ã³ãã£ã«ã¿ã®å¹æãäœæžãã ããšããããŸãã â ãµãŒãžã¢ã¬ã¹ã¿ã®æ¥ç¶ ãµãŒãžã¢ã¬ã¹ã¿ã«ã¯ãäžè¡šã®è£œåãŸãã¯çžåœåã䜿çšããŠãã ããã å²¡è°·é»æ©ç£æ¥æ ªåŒäŒç€Ÿ ãã§ããã¯ã¹ã»ã³ã³ã¿ã¯ãæ ªåŒäŒç€Ÿ RCM-601BQZ-4 VAL-MS 230VF ST éèŠ è£ çœ®ã®èå§è©Šéšãè¡ãªããšãã¯ããµãŒãžã¢ã¬ã¹ã¿ãåãå€ããŠãã ããã ãµãŒãžã¢ã¬ã¹ã¿ãç Žæããåå ã«ãªããŸãã â ã¢ãŒã¿ãŒã±ãŒãã«ã®æ¥ç¶ ã¢ãŒã¿ãŒã±ãŒãã«ãå»¶é·ãããšãã¯ãAWG18(0.75mm2 )以äžã10m以äžã®ã±ãŒãã«ã䜿çšããŠã ã ããã ãŸããã¬ãŒããžã§ãã¬ãŒã¿ç·ã®å»¶é·ã«ã¯ã·ãŒã«ãã±ãŒãã«ã䜿çšããŠãã ããã â å¶åŸ¡çšã±ãŒãã«ã®é ç· ã¹ããŒãã³ã³ãããŒã©ã®å¶åŸ¡çšã±ãŒãã«ã«ã¯ã以äžã®ç·šçµã·ãŒã«ãã±ãŒãã«ã䜿çšããŠã§ããã ã çã(2mä»¥äž )é ç·ããŠãã ããã â AWG28(0.08 mm2 )ä»¥äž â ç·šçµã·ãŒã«ããšãªãŒãç·å°äœéšéã®çµ¶çžäœã®åã¿ã0.4 mmä»¥äž â ç·šçµã·ãŒã«ãã±ãŒãã«ã®å å·¥å¯žæ³ 4mmä»¥äž å¿ç· 6 è¢«èŠ ç·šçµã·ãŒã«ã ã·ãŒã¹ ã·ãŒã«ãã±ãŒãã«ã®æ¥å°ã«ã¯ãéå±è£œã®ã±ãŒãã«ã¯ã©ã³ããªã©ãã·ãŒã«ãã±ãŒãã«ã®å šåšãšæ¥è§Šã§ ããã¯ã©ã³ãã䜿çšããŠãã ãããã±ãŒãã«ã¯ã©ã³ãã¯ãã·ãŒã«ãã±ãŒãã«ã®ã§ããã ãå 端éšåã« åãä»ããå³ã®ããã«é©åãªæ¥å°ãã€ã³ãã«æ¥å°ããŠãã ããã ã·ãŒã«ãã±ãŒãã« ã±ãŒãã«ã¯ã©ã³ã â ãã®ä» â ã¢ãŒã¿ãŒ/ã¹ããŒãã³ã³ãããŒã©ãšåšèŸºã®å¶åŸ¡ã·ã¹ãã æ©åšã®ã¢ãŒã¹éã«é»äœå·®ãçããªãããã«ã çŽæ¥æ¥å°ãã€ã³ãã«æ¥å°ããŠãã ããã â ãªã¬ãŒãé»ç£ã¹ã€ãããäžç·ã«äœ¿çšãããšãã¯ãACã©ã€ã³ãã£ã«ã¿ãCRåè·¯ã§ãµãŒãžãåžåã ãŠãã ããã â ã±ãŒãã«ã¯ãé·ãããŠäœã£ãéšåãå·»ããŠæãããããªãã§ãã§ããã ãçãããŠãã ããã â ååç³»ã®ã±ãŒãã«ãšå¶åŸ¡ç³»ã®ã±ãŒãã«ã¯åããã§ããã ããäºããé¢ããŠ(äŸïŒ100âŒ200 mm) é ç·ããŠãã ãããååç³»ã®ã±ãŒãã«ãšå¶åŸ¡ç³»ã®ã±ãŒãã«ã亀差ãããšãã¯ãçŽè§ã«äº€å·®ãã ãŠãã ããããŸããACã©ã€ã³ãã£ã«ã¿ã®ACå ¥ååŽã±ãŒãã«ãšåºååŽã±ãŒãã«ã¯ãåé¢ããŠé ç· ããŠãã ããã â ã¢ãŒã¿ãŒãã¹ããŒãã³ã³ãããŒã©ã®èšçœ®ã»é ç·äŸ ã¢ãŒã¿ãŒ ã¹ããŒãã³ã³ãããŒã© ã¢ãŒã¿ãŒã±ãŒãã«(10m) 黿ºã±ãŒãã« ã±ãŒãã« ã¯ã©ã³ã ãµãŒãž AC ã©ã€ã³ãã£ã«ã¿ ã¢ã¬ã¹ã¿ ã°ã©ã³ãããã« ã±ãŒãã« ã¯ã©ã³ã å¶åŸ¡çšã±ãŒãã«(2m) ã³ã³ãã³ãµ 7 æ¥ç¶ã»é転 æ¬¡ã®æé ã§ãã¹ããŒãã³ã³ãããŒã©ã黿ºãã¢ãŒã¿ãŒãã¹ã€ãããšæ¥ç¶ããŠãã ããã 1. ã«ããŒäžå€®ã«ãããã«ããŒåºå®çšãã(M4 1ãæ)ãããããã«ããŒãå€ãã 2. å端åã®æ¥ç¶ãè¡ãªãã 3. ã«ããŒãåãä»ããŠãã«ããŒåºå®çšãã(M4 1ãæ)ã§åºå®ããã ç· ãä»ããã«ã¯ïŒ0.7Nm ãã€ãºå¯Ÿçã«ã€ããŠã¯ã ãEMCæä»€ã«é©åãããèšçœ®ã»é ç·æ¹æ³ã(P. 5)ãã芧ãã ããã åéšã®åç§°ãšæ©èœ 1 2 3 å³ã¯ãã«ããŒãå€ããç¶æ ã§ããæ¥ç¶åŸã¯ã«ããŒãåãä»ããŠãã ããã 4 1 POWER LED 5 黿ºãäŸçµŠãããŠãããšãã«ãç¹ç¯(ç·)ããŸãã 2 å éšé床èšå®åš ã¢ãŒã¿ãŒã®é転é床ãèšå®ããŸãã LED1 VR2 VR3 VR1 TB3 3 ã¹ããŒã¹ã¿ãŒãæéèšå®åš S1 S2 S3 S4 S5 S6 POWER SPEED ACCEL DECEL ã¢ãŒã¿ãŒèµ·åæã®å éæéãèšå®ããŸãã INT-VR STOP 4 ã¹ããŒããŠã³æéèšå®åš ã¢ãŒã¿ãŒåæ¢æã®æžéæéãèšå®ããŸãã EXT-VR BRAKE 5 å¶åŸ¡å ¥å端å åä»ç©Ž åä»ç©Ž G 7 8 10 NC 11 BLU BLU 1 2 3 4 5 6 FG N L BLK RED WHT MOTOR 8 9 S1 é転ãšå¶åã®å ±é端åã§ãã S2 é転 / åæ¢å ¥å é転(OFF) / 忢(ON)ããŸãã S3 é転 / å¶åå ¥å é転(OFF) / å¶å(ON)ããŸãã S4ãS5ãS6 é床èšå®åšå ¥å S4ãšS5ãç絡ãããšãå éšé床èšå®åšã§ é床èšå®ãã§ããŸãã S4ãšS5ãéæŸãããšãå€éšé床èšå®åšã§ é床èšå®ãã§ããŸãã å€éšé床èšå®åšã¯ãS4ãšS6ã«æ¥ç¶ããŸãã 6 黿ºæ¥ç¶ç«¯å (端å 2, 3) 7 10 6 DINã¬ã㌠7 ã¢ãŒã¿ãŒæ¥ç¶ç«¯å (端å 4, 5, 6) 端å4ã«ã¯ãé»ã®ã¢ãŒã¿ãŒãªãŒãç·ãæ¥ç¶ããŸãã 端å5ã«èµ€ã端å6ã«çœã®ã¢ãŒã¿ãŒãªãŒãç·ã æ¥ç¶ãããšãã¢ãŒã¿ãŒåºå軞ããèŠãŠæèšæ¹å ã«å転ããŸãã 端å5ã«çœã端å6ã«èµ€ã®ã¢ãŒã¿ãŒãªãŒãç·ã æ¥ç¶ãããšãã¢ãŒã¿ãŒåºå軞ããèŠãŠåæèš æ¹åã«å転ããŸãã 8 端å 7, 8 äžæ¹åé転ã®å Žåãã³ã³ãã³ãµãæ¥ç¶ããŸãã 9 ã¬ãŒããžã§ãã¬ãŒã¿æ¥ç¶ç«¯å (端å10, 11) éã®ã¬ãŒããžã§ãã¬ãŒã¿ãªãŒãç·ãæ¥ç¶ããŸãã 10 FG端å (端å 1) 8 ã¢ãŒã¿ãŒã»é»æºæ¥ç¶ç«¯åã®æ¥ç¶ é©çšå§ç端å 端åãããµã€ãºïŒM3.5 ç· ãä»ããã«ã¯ïŒ1Nm 3.7mmä»¥äž 9mmä»¥äž (çµ¶çžæä»äžžå端å) 7.8mmä»¥äž 7.8mmä»¥äž Ï3.7mmä»¥äž 9mmä»¥äž (çµ¶çžæä»å é端å) å¶åŸ¡å ¥å端åã®æ¥ç¶ é©çšãªãŒãç·åŸïŒAWG28âŒ16(0.08âŒ1.5mm2) ãªãŒãç·ã®ç®ããé·ãïŒ5âŒ7mm ç· ãä»ããã«ã¯ïŒ0.22âŒ0.25Nm ãŒãã©ã€ã åå å 0.3âŒ0.4mm åå å¹ 2âŒ2.5mm æ¥ç¶äŸ éèŠ ãœã¬ãã€ããé«å𿳢黿ºã黿°æº¶æ¥æ©ãªã©ã¯ãã¹ããŒãã³ã³ãããŒã©ã®èª€åäœã®åå ãšãªãããšããã㟠ããããããšã¯å¥é»æºãçšããå¶åŸ¡ã©ã€ã³ãšååã©ã€ã³ã¯åé¢ããŠé ç·ããŠãã ããã ã¹ã€ããããã¥ãŒãºã®å®æ Œ 黿ºé»å§ SW1 SW2ãSW3 SW4 R 0ãC 0 (ãµãŒãžãã©ãŒ) ãã¥ãŒãº 100V/110V/115V (ES01) AC125V 10A AC125V 10A 200V/220V/230V (ES02) AC250V 5A DC18V 1mA AC250V 5A R 0 ïŒ5~200⊠C 0 ïŒ0.1~0.2ÎŒFã200WV R 0 ïŒ5~200⊠C 0 ïŒ0.1~0.2ÎŒFã400WV UL/CSA248-14 èŠæ Œèªå®åãŸãã¯çžåœå AC250V 10A UL/CSA248-14 èŠæ Œèªå®åãŸãã¯çžåœå AC250V 5A éèŠ å¶åŸ¡å ¥å端åã¯AC黿ºãšçµ¶çžãããŠããŸãããå¶åŸ¡å ¥å端åã«æ¥ç¶ããæ©åš (ããã°ã©ããã«ã³ã³ã ããŒã©ããªã¬ãŒãã¹ã€ãã)ã¯ãæ¥ç¹éšã®å®æ ŒãDC18Vã1mA以äžã®ãã®ã䜿çšããŠãã ããã人ãçŽæ¥ è§Šããéšåã«ã¯åŒ·åçµ¶çžãæœããŠãã ããã âãã©ã³ãžã¹ã¿åºåã¿ã€ãã®ã³ã³ãããŒã©ã¯æ¥ç¶ããªãã§ãã ããã â 9 â äžæ¹åé転 (å éšé床èšå®åšã䜿çšããå Žå) é転 SW2 å¶å SW3 é転 忢 LED1 VR2 VR3 VR1 TB3 S1 S2 S3 S4 S5 S6 POWER SPEED ACCEL DECEL INT-VR STOP EXT-VR BRAKE G 7 8 10 NC AWG18(0.75mm2 )ä»¥äž ã³ã³ãã³ãµ ES01 AC100V AC110V AC115V ES02 AC200V AC220V AC230V 11 BLU BLU 1 2 3 4 5 6 FG N L BLK RED MOTOR WHT ã¢ãŒã¿ãŒ AWG18(0.75mm2 ) ä»¥äž é é ãã¬ãŒã ã°ã©ã³ã 50/60Hz 60Hz 60Hz 50/60Hz 50/60Hz 50/60Hz ãã¥ãŒãº 黿º SW1 AWG18(0.75mm2 )ä»¥äž çœ èµ€ é» æ©ïŒ æ©ïŒ ïŒå·åŽãã¡ã³çšãªãŒãç·ã§ãã 60Wã¿ã€ãã90Wã¿ã€ãã®ã¿æ¥ç¶ããŸãã â ã¢ãŒã¿ãŒãšã¹ããŒãã³ã³ãããŒã©éã®é ç·ã®é·ãã¯ã10m以äžãšããŠãã ããã â å¶åŸ¡çšã±ãŒãã«ã®é·ãã¯2m以äžãšãã ã§ããã ãçãé ç·ããŠãã ããã â ã¹ã€ããããã¥ãŒãºã®å®æ Œã¯ã9ããŒãžãåç §ããŠãã ããã â ã¢ãŒã¿ãŒãæ¥å°ãããšãã¯ãä¿è·æ¥å°ç«¯åã®ãããã®ã¯ä¿è·æ¥å°ç«¯åã䜿çšããŠãã ããã 10 â æ£éé転 (å éšé床èšå®åšã䜿çšããå Žå) é転 SW2 å¶å é転 SW3 忢 LED1 VR2 VR3 VR1 TB3 S1 S2 S3 S4 S5 S6 POWER SPEED ACCEL DECEL INT-VR STOP EXT-VR BRAKE G 7 8 10 NC 11 BLU BLU 1 2 3 4 5 6 FG N L BLK RED MOTOR WHT AWG18(0.75mm2 )ä»¥äž ES01 AC100V 50/60Hz AC110V 60Hz AC115V 60Hz ãã¬ãŒã ã°ã©ã³ã ES02 AC200V 50/60Hz AC220V 50/60Hz AC230V 50/60Hz 黿º SW1 ãã¥ãŒãº AWG18(0.75mm2 ) ä»¥äž é Co é Ro CW â ã¢ãŒã¿ãŒãšã¹ããŒãã³ã³ãããŒã©é CCW ã®é ç·ã®é·ãã¯ã10m以äžãšã㊠ãã ããã â å¶åŸ¡çšã±ãŒãã«ã®é·ãã¯2mä»¥äž ãšããã§ããã ãçãé ç·ããŠã ã ããã â ã¹ã€ããããã¥ãŒãºããµãŒãžãã©ãŒ ã®å®æ Œã¯ã9ããŒãžãåç §ããŠã ã ããã â ã¢ãŒã¿ãŒãæ¥å°ãããšãã¯ãä¿è· æ¥å°ç«¯åã®ãããã®ã¯ä¿è·æ¥å° 端åã䜿çšããŠãã ããã Co Co ã¢ãŒã¿ãŒ Ro Ro CW SW4 CCW Co Ro çœ èµ€ é» æ©ïŒ æ©ïŒ AWG18 (0.75mm2 )ä»¥äž ïŒå·åŽãã¡ã³çšãªãŒãç·ã§ãã 60Wã¿ã€ãã90Wã¿ã€ãã®ã¿æ¥ç¶ããŸãã ã³ã³ãã³ãµ éèŠ SW4ã«ã¯ãå¿ ããµãŒãžãã©ãŒãæ¥ç¶ããŠãã ããããµãŒãžãã©ãŒãæ¥ç¶ããªããšãã¹ããŒãã³ã³ãããŒã© ãç Žæããåå ã«ãªããŸãã åœç€Ÿã§ããªãã·ã§ã³ãšããŠãµãŒãžé»å§åžåçšCRåè·¯EPCR1201-2ãçšæããŠããŸãã 11 æäœæ¹æ³ å éšé床èšå®åšãé«éãå€éšé床èšå®åšãäœéã«èšå®ããŠãããé床ã2段éã«åãæ¿ããäŸ (P.15åç § )ã§ãã ã¹ããŒã¹ã¿ãŒãã» é転ã»ç¬æåæ¢ 2éåãæ¿ãã»åæ¢ é«é ã¹ããŒããŠã³é転ïŒ1 é«é äœé CW (æèšæ¹å) ã¢ãŒã¿ãŒã®åã CCW (åæèšæ¹å) äœé ON OFF SW1 黿º SW3 ïŒ2 OFF é転/åæ¢å ¥å ON é転 SW2 ïŒ2 OFF é転/å¶åå ¥å ON é転 SW4 CW/CCWå ¥å å éšé床èšå®/ å€éšé床èšå® 忢 é転 忢 0.5sä»¥äž CW CCW CW å éš å€éš å éš å¶å é転 å¶å CCW å€éš é転 CW å éš å€éš å éš ïŒ1 ã¹ããŒã¹ã¿ãŒãã»ã¹ããŒããŠã³æéèšå®åšãæèšæ¹åã«åããŠãèšå®æéãé·ãããå Žåã§ãã ïŒ2 SW2ãšSW3ãåæã«ONãããšãå¶åå ¥åãåªå ãããŸãã éèŠ é転 / å¶åå ¥åãONã«ãããšãå¶å黿µãçŽ0.4ç§éæµããŸãã é転 / å¶åå ¥åãONã«ããåŸ0.5ç§éã¯ããã¹ãŠã®ã¹ã€ãããåãæ¿ããªãã§ãã ãããã¹ããŒãã³ã³ã ããŒã©ãç Žæããåå ã«ãªããŸãã â é転/å¶åã忢 SW2ãSW3ãé転(OFF )ã«ãããšãã¢ãŒã¿ãŒã¯é床èšå®åšã§èšå®ãããé床ã§å転ããŸãã é転äžã«SW2ãå¶å(ON)ã«ãããšã é転 /åæ¢å ¥å é転 /å¶åå ¥å ã¢ãŒã¿ãŒã®åã ã¢ãŒã¿ãŒã¯ç¬æåæ¢ããŸãã OFF OFF é転 é転äžã«SW3ã忢(ON)ã«ãããšã OFF ON ç¬æåæ¢ ã¢ãŒã¿ãŒã¯èªç¶åæ¢ããŸãã ON OFF èªç¶åæ¢ â å転æ¹åã®åãæ¿ã SW4ã§ã¢ãŒã¿ãŒã®å転æ¹åãåãæ¿ããŸãã SW4ãCWã«ãããšãã¢ãŒã¿ãŒåºå軞ããèŠãŠæèšæ¹åã«å転ããŸãã SW4ãCCWã«ãããšãã¢ãŒã¿ãŒåºå軞ããèŠãŠåæèšæ¹åã«å転ããŸãã ã®ã€ã®æžéæ¯ã«ãã£ãŠã¯ãã®ã€åºå軞ã®å転æ¹åã¯ã¢ãŒã¿ãŒè»žã®å転æ¹åãšéã«ãªããŸãã éèŠ SW4ã«ã¯ãå¿ ããµãŒãžãã©ãŒãæ¥ç¶ããŠãã ããããµãŒãžãã©ãŒãæ¥ç¶ããªããšãã¹ããŒãã³ã³ãããŒã© ãç Žæããåå ã«ãªããŸãã åœç€Ÿã§ããªãã·ã§ã³ãšããŠãµãŒãžé»å§åžåçšCRåè·¯EPCR1201-2ãçšæããŠããŸãã â ã¬ããŒã·ãã«ã¢ãŒã¿ãŒã¯ãç¬æã®æ£éé転ãã§ããŸãã â ã€ã³ãã¯ã·ã§ã³ã¢ãŒã¿ãŒã§æ£éé転ãããšãã¯ãã¢ãŒã¿ãŒãå®å šã«åæ¢ããŠããå転æ¹åãåã æ¿ããŠãã ããã 12 â é床ã®èšå® 2000 60Hz 50Hz 1500 å転é床 [r/min] å éšé床èšå®åšã䜿çšããŸããèšå®é床ç¯å²ã¯ 50Hzã§90âŒ1400r/minã60Hzã§90âŒ1600r/min ã§ãã é床èšå®åšå ¥å端åS4ãšS5ãç絡ããŸãã å éšé床èšå®åšãæèšæ¹åã«ãŸãããšãèšå® é床ãéããªããŸããåºè·æã¯0 r/minã«èšå® ããŠããŸãã 1000 500 0 0 10 2 4 6 8 10 å éšé床èšå®åšâç®ç å éšé床èšå®åšâç®ç-å転éåºŠç¹æ§ïŒä»£è¡šå€ïŒ å éšé床èšå®åš ã¹ããŒãã³ã³ãããŒã©ãšé¢ãããšããã§éåºŠèš å®ãããšãã2 段é以äžã®é床å¶åŸ¡ãè¡ãªããš ãã¯ãä»å±ã®å€éšé床èšå®åšã䜿çšããŸãã 14ã15ããŒãžãåç §ããŠãã ããã ã¹ããŒã¹ã¿ãŒãé転ã»ã¹ããŒããŠã³é転 èµ·åã忢ãå€éæã«è² è·ã«è¡æãããããªãããã«ãå æžéæéã調æŽã§ããŸããã¹ããŒã¹ã¿ ãŒãæéèšå®åšãã¹ããŒããŠã³æéèšå®åšã§èšå®ããŸããèšå®æéã¯ãçŽ0.5âŒ10ç§(1000r/min èšå®æãæ £æ§è² è·ç¡ãã®ç¶æ )ã§ãã ãã ããè² è·æ £æ§ã倧ããå Žåãèªç¶åæ¢ããããšãã®æéããçãã¹ããŒããŠã³æéãèšå®ã ãããšã¯ã§ããŸããã â ã¹ããŒã¹ã¿ãŒã 15 ã¹ããŒã¹ã¿ãŒãæé [sec / 1000r/ min] ã¹ããŒã¹ã¿ãŒãã¯ãèµ·åæããã³ 2段éã®é床 å¶åŸ¡ã§é床ãé«éã«åãæ¿ãããšãã«ã¯ãã ããŸãã ã¹ããŒã¹ã¿ãŒãæéèšå®åšãæèšæ¹åã«ãŸã ããšãèšå®æéãé·ããªããŸãã åºè·æã¯ã0(ã¹ããŒã¹ã¿ãŒãããªã)ã«èšå®ã ããŠããŸãã 10 5 0 0 10 2 4 6 8 10 ã¹ããŒã¹ã¿ãŒãæéèšå®åšâç®çïŒä»£è¡šå€ïŒ ã¹ããŒã¹ã¿ãŒãæéèšå®åš 13 â ã¹ããŒããŠã³ 20 ã¹ããŒããŠã³æé [sec / 1000r / min] ã¹ããŒããŠã³ã¯ãèªç¶åæ¢ããã³2段éã®é床 å¶åŸ¡ã§é床ãäœéã«åãæ¿ãããšãã«ã¯ããã ãŸãã ã¹ããŒããŠã³æéèšå®åšãæèšæ¹åã«ãŸãã ãšãèšå®æéãé·ããªããŸãã åºè·æã¯ã0(ã¹ããŒããŠã³ããªã)ã«èšå®ãã ãŠããŸãã 15 10 5 0 0 10 2 4 6 8 10 ã¹ããŒããŠã³æéèšå®åšâç®çïŒä»£è¡šå€ïŒ ã¹ããŒããŠã³æéèšå®åš å€éšé床èšå®åšã䜿ã£ãé床èšå® é床èšå®åšå ¥å端åS4ãšS5ãéæŸããŸãã æ¥ç¶ãããšãã¯ãå€éšé床èšå®åšã®ããããåæèšæ¹åã«åããé床èšå®ã0r/minã«ããŠãã ããã å€éšé床èšå®åšã®ããããæèšæ¹åã«ãŸãããšãèšå®é床ãéããªããŸãã å€éšé床èšå®åšâ20k 1/4W Bç¹æ§ 2000 60Hz å転é床 [r/min] 1 1 50Hz 3 1500 3 2 1000 500 0 TB3 S1 S2 S3 S4 5 10 15 20 é床èšå®æµæå€ [k ] é床èšå®æµæå€-å転éåºŠç¹æ§ïŒä»£è¡šå€ïŒ S5 S6 éèŠ 1åã®å€éšé床èšå®åšã§è€æ°ã®ã¹ããŒãã³ã³ãã ãŒã©ãé転ããªãã§ãã ãããã¹ããŒãã³ã³ãã ãŒã©ãç Žæããåå ã«ãªããŸãã 14 â å仿é 1. äžå³ã®ããã«ãçµ¶çžã·ãŒããå¯å€æµæåšãå仿¿ã®ç©Žã«å·®ã蟌ãã§ãã ããã 2. ç®çæ¿ãæ¯ä»ãã¯ãã·ã£ãå ¥ãããããã§ç· ãä»ããŠãã ãããç· ãä»ããã«ã¯ã¯0.45Nmã§ãã 3. ããããåãä»ããæ¢ããã(M4)ã§åºå®ããŠãã ãããç· ãä»ããã«ã¯ã¯0.4Nmã§ãã å¯å€æµæåš çµ¶çžã·ãŒã å仿¿ ç®çæ¿ æ¢ããã 50 60 40 0.4 7.5 70 80 30 90 ããã 0 10 20 10 0 Ï3 Ï10 ããã æ¯ä»ãã¯ãã·ã£ åä»ç©Žåè寞æ³å³ [åäœ: mm] â å€éšé床èšå®åšã®ç«¯åã®ã¯ãã ä»ã ãªãŒãç·ã端å穎ã«2ã3åå·»ãä»ãã¯ãã ä»ãããçµ¶çžãã¥ãŒãã被ããŠãã ããã â 2段éã®é床å¶åŸ¡ å éšé床èšå®åšãšå€éšé床èšå®åšãåãæ¿ããããšã§ã2段éã®é床å¶åŸ¡ãã§ããŸãã SW(é床èšå®åãæ¿ã)ã§å éšé床èšå®åšãå€éšé床èšå®åšãéžæããŸãã å€éš å éš 1 2 å€éšé床èšå®åš 3 éèŠ TB3 S1 S2 S3 S4 S5 S6 å¶åŸ¡å ¥å端åã¯AC黿ºãšçµ¶çžãããŠããŸããã å¶åŸ¡å ¥å端åã«æ¥ç¶ããæ©åš(ããã°ã©ããã«ã³ ã³ãããŒã©ããªã¬ãŒãã¹ã€ãã)ã¯ãæ¥ç¹éšã®å®æ Œã DC18Vã1mA以äžã®ãã®ã䜿çšããŠãã ããã人 ãçŽæ¥è§Šããéšåã«ã¯åŒ·åçµ¶çžãæœããŠãã ããã 15 é転ã»å¶åç¹°ãè¿ããµã€ã¯ã« çããµã€ã¯ã«ã§ã¢ãŒã¿ãŒã®é転 - å¶åãç¹°ãè¿ããšãã¢ãŒã¿ãŒã®æž©åºŠäžæã倧ãããªããé£ç¶äœ¿çš æéãå¶éãããŸãã 以äžãç®å®ã«ããŠãã ããã ã¢ãŒã¿ãŒåºå 6âŒ40W 60W 90W ç¹°ãè¿ããµã€ã¯ã« 2ç§ä»¥äž(é転æé1ç§ã忢æé1ç§) 4ç§ä»¥äž(é転æé2ç§ã忢æé2ç§) å¶å黿µ ã¢ãŒã¿ãŒãç¬æåæ¢ããããšãã¯ãäžè¡šã®ãããªå¶å黿µãæµããŸãããã®å€ãåèã«é»æºãçš æããŠãã ããã ã¢ãŒã¿ãŒåºå 6W 15W 25W 40W 60W 90W å¶å黿µ (ããŒã¯å€) [A] åçž100V/110V/115V åçž200V/220V/230V 1.5 1.0 3.5 2.0 5.5 4.0 8.5 6.0 15.5 8.0 20.5 12.0 ç¹ æ€ é転åŸã¯ã宿çã«æ¬¡ã®é ç®ã«ã€ããŠç¹æ€ããããšãããããããŸãã ç°åžžããããšãã¯äœ¿çšãäžæ¢ããã客æ§ãçžè«ã»ã³ã¿ãŒã«ãåãåãããã ããã â ã¹ããŒãã³ã³ãããŒã©ã®åãä»ãããã黿ºæ¥ç¶ç«¯åã®ããã«ããã¿ããªããã â ãªã¬ãŒãã¹ã€ããã䜿çšããŠããå Žåãæ¥ç¹ã®æ¶èãæº¶çããªããã 16 æ éã®èšºæãšåŠçœ® ã¢ãŒã¿ãŒé転æã«ãé床èšå®ãæ¥ç¶ã®èª€ããªã©ã§ã¢ãŒã¿ãŒãã¹ããŒãã³ã³ãããŒã©ãæ£åžžã«åäœ ããªãããšããããŸããã¢ãŒã¿ãŒã®é転æäœãæ£åžžã«è¡ãªããªããšãã«ã¯ããã®é ãã芧ã«ãªã£ ãŠãé©åãªåŠçœ®ãè¡ãªã£ãŠãã ãããããã§ãæ£åžžã«é転ã§ããªããšãã¯ãæå¯ãã®ã客æ§ãçž è«ã»ã³ã¿ãŒã«ãåãåãããã ããã éé»ç¶æ ã§ã®ç¢ºèªãå¿ èŠãªé ç®ããããŸããæŽ»é»éšã«è§Šããªãããååæ³šæããŠè¡ãªã£ãŠãã ããã çŸ è±¡ ã¢ãŒã¿ãŒãå転ããªã é床ãå€åããªã äºæ³ãããåå åŠ çœ® é転 / åæ¢å ¥åãŸãã¯é転 / å¶ åå ¥åãONã«ãªã£ãŠããã é転 /åæ¢å ¥åãŸãã¯é転 /å¶åå ¥åãOFFã« ããŠãã ããã å éšé床èšå®åšãå€éšéåºŠèš å®åšã調æŽããŠããªãã å éšé床èšå®åšãŸãã¯å€éšé床èšå®åšãæèš æ¹åã«åããŠãã ãããåºè·æã¯0 r/minã«èš å®ãããŠããŸãã å éšé床èšå®åšã䜿çšãããš ãã«ãé床èšå®åšå ¥å端åS4 ãšS5ãç絡ããŠããªãã é床èšå®åšå ¥å端åS4ãšS5ãç絡ããŸãã å€éšé床èšå®åšã®æ¥ç¶äžè¯ã å€éšé床èšå®åšã®æ¥ç¶ã確èªããŠãã ããã å€éšé床èšå®åšã䜿çšãããš ãã«ãé床èšå®åšå ¥å端åS4 ãšS5ãéæŸããŠããªãã é床èšå®åšå ¥å端åS4ãšS5ãéæŸããŸãã ã¢ãŒã¿ãŒã®åäœãäžå®å® ãã€ãºã®åœ±é¿ãåããŠããã æ¯åã倧ãã ãã€ãºã®åœ±é¿ã確èªã§ãããšãã¯ããã€ãºçºç æºãšã®éé¢ãé ç·ãèŠçŽããŠãã ããã ãã€ãºå¯Ÿçã«ã€ããŠã¯ã5âŒ7ããŒãžãã芧ã ã ããã ã¢ãŒã¿ãŒãããã«èµ·åã ã¹ããŒã¹ã¿ãŒãæéèšå®åšã㯠ãªã ããããŠããã ã¹ããŒã¹ã¿ãŒãæéèšå®åšããåæèšæ¹åã«æ¢ ãŸããŸã§åããŠãã ããã è² è·æ £æ§ã倧ããããå¯èœæ§ ããããŸãã ã¢ãŒã¿ãŒãç¬ææ£é転 è² è·æ £æ§ã倧ããããå¯èœæ§ ããªã ããããŸãã è² è·æ £æ§ãå°ããããŠãã ããã æ©æŠè² è·ãå¢ãããè² è·æ £æ§ãå°ããããŠã ã ããã ãªã¬ãŒãã¹ã€ããã䜿çšããŠã ãå Žåãæ¥ç¹ã溶çããŠããã ãªã¬ãŒãã¹ã€ããã確èªããŠãã ããã ã¢ãŒã¿ãŒãç¬æåæ¢ã é転 /åæ¢å ¥å(èªç¶åæ¢)ã§å ãªã æ¢ããŠããã é転/å¶åå ¥åã§åæ¢ãããŠãã ããã è² è·æ £æ§ã倧ããããå¯èœæ§ ããããŸãã æ©æŠè² è·ãå¢ãããè² è·æ £æ§ãå°ããããŠã ã ããã 17 â ãã®åæ±èª¬ææžã®äžéšãŸãã¯å šéšãç¡æã§è»¢èŒãè€è£œããããšã¯ãçŠæ¢ãããŠããŸãã æå·ãçŽå€±ãªã©ã«ãããåæ±èª¬ææžãå¿ èŠãªãšãã¯ãæå¯ãã®æ¯åºãŸãã¯å¶æ¥æã«è«æ± ããŠãã ããã â åæ±èª¬ææžã«èšèŒãããŠããæ å ±ãåè·¯ãæ©åšãããã³è£ 眮ã®å©çšã«é¢ããŠç£æ¥è²¡ç£æš© äžã®åé¡ãçããŠããåœç€Ÿã¯äžåã®è²¬ä»»ãè² ããŸããã â 補åã®æ§èœã仿§ããã³å€èŠ³ã¯æ¹è¯ã®ããäºåãªã倿ŽããããšããããŸãã®ã§ãäºæ¿ ãã ããã â åæ±èª¬ææžã«ã¯æ£ç¢ºãªæ å ±ãèšèŒããããåªããŠããŸãããäžäžãäžå¯©ãªç¹ã誀ããèš èŒãããªã©ã«ãæ°ã¥ãã®ç¹ããããŸããããæå¯ãã®ã客æ§ãçžè«ã»ã³ã¿ãŒãŸã§ãé£çµ¡ ãã ããã â ã¯ãæ¥æ¬ãã®ä»ã®åœã«ããããªãªãšã³ã¿ã«ã¢ãŒã¿ãŒæ ªåŒäŒç€Ÿã®ç»é²åæš ãŸãã¯åæšã§ãã ãã®ä»ã®è£œååãäŒç€Ÿåã¯å瀟ã®ç»é²åæšãŸãã¯åæšã§ãããã®åæ±èª¬ææžã«èšèŒã® ä»ç€Ÿè£œååã¯æšå¥šãç®çãšãããã®ã§ããããã®è£œåã®æ§èœãä¿èšŒãããã®ã§ã¯ãã㟠ããããªãªãšã³ã¿ã«ã¢ãŒã¿ãŒæ ªåŒäŒç€Ÿã¯ãä»ç€Ÿè£œåã®æ§èœã«ã€ããŸããŠã¯äžå ã®è²¬ä»»ã è² ããŸããã © Copyright ORIENTAL MOTOR CO., LTD. 2008 HP-5018-8 Speed Controller ES01 ES02 OPERATING MANUAL Table of Contents Before using the product âŠâŠâŠâŠâŠ Page 2 Safety precautions âŠâŠâŠâŠâŠâŠâŠâŠ Page 3 Installation âŠâŠâŠâŠâŠâŠâŠâŠâŠâŠâŠâŠ Page 5 Connection and operation âŠâŠâŠâŠâŠ Page 8 Inspection âŠâŠâŠâŠâŠâŠâŠâŠâŠâŠâŠâŠ Page 16 Troubleshooting and remedial actions âŠâŠâŠâŠâŠâŠâŠâŠâŠ Page 17 Thank you for purchasing an Oriental Motor product. This Operating Manual describes product handling procedures and safety precautions. â Please â Always read it thoroughly to ensure safe operation. keep the manual where it is readily available. Before using the product Introduction This operating manual describes the speed controllers ES01/ES02. The speed controllers are designed solely to drive (control the speed of ) dedicated speed control motors based on closed-loop phase control. The World K Series and V Series speed control motors (6 W~ 90 W) can be driven by the ES01/ ES02. Refer also to the operating manual for the applicable motor. This product must be handled by qualified personnel with expert knowledge of electrical and mechanical engineering. Before using the product, read the âSafety precautionsâ carefully to ensure correct use. Should you require the inspection or repair of internal parts, contact the Oriental Motor office where you purchased the product. The product described in this manual has been designed and manufactured for use in general industrial machinery, and must not be used for any other purpose. Oriental Motor Co., Ltd. is not responsible for any damage caused through failure to observe this warning. Standards and CE marking This product is recognized by UL. The CE marking (Low Voltage Directive and EMC Directive) is affixed to the product in accordance with EN standards. â Applicable standards Applicable standards Certification body Standards file No. UL File No. E91291 - - UL508 CSA C.22.2 No.14 EN50178â EN60950-1 EN61000-6-4 EN61000-6-2 â The overvoltage protection test required under standard EN50178 is not performed. Perform the test when incorporated into the final product. â Installation conditions (EN standards) The product is to be used as a component within other equipment (Class II equipment ), Overvoltage category II, Pollution degree: 2, IP20 â For low voltage directive This product is designed for use as a built-in component. â For EMC directive This product has received EMC measures under the conditions specified in âExample of motor and speed controller installation and wiringâ on page 7. Be sure to conduct EMC measures with the product assembled in your equipment by referring to âInstalling and wiring in compliance with EMC directiveâ on page 5. â Hazardous substances RoHS (Directive 2002/95/EC 27Jan.2003) compliant 2 Safety precautions The precautions described below are intended to prevent danger or injury to the user and other personnel through safe, correct use of the product. Use the product only after carefully reading and fully understanding these instructions. Warning Handling the product without observing the instructions that accompany a â Warning â symbol may result in serious injury or death. Caution Handling the product without observing the instructions that accompany a â Cautionâ symbol may result in injury or property damage. Connection â Keep the speed controllerâs input-power voltage within the specification to avoid fire and electric shock. â Connect the cables securely according to the wiring diagram in order to prevent fire and electric shock. â Do not forcibly bend, pull or pinch the cable. Doing so may result in fire and electric shock. â To prevent electric shock, be sure to install the speed controllerâs after making connections. â Be sure to insulate the connection terminal of the external speed potentiometer. Failure to do so may result in electric shock. â The speed controller has no built-in fuse for overcurrent protection. Install a device for overcurrent protection (e.g. fuse) before connecting the unit to the power source. Failure to do so may result in fire. NOTE The items under this heading contain important handling instructions that the user should observe to ensure safe use of the product. Warning General â Do not use the product in explosive or corrosive environments, in the presence of flammable gases, locations subjected to splashing water, or near combustibles. Doing so may result in fire, electric shock or injury. â Installation, connection, operating/controlling, inspecting and troubleshooting must be performed by personnel with expert knowledge of electrical and mechanical engineering. Failure to do so may result in fire, electric shock or injury. â Do not transport, install the product, perform connections or inspections when the power is on. Always turn the power off before carrying out these operations. Failure to do so may result in electric shock. Operation â Turn off the speed controller power in the event of a power failure, or the motor may suddenly start when power is restored and may cause injury or damage to equipment. Maintenance and inspection â Do not touch the terminal block of the speed controllerâs motor and power immediately after the power is turned off (for a period of 1 minute). This may cause electric shock. Repair, disassembly and modification â Do not disassemble or modify the speed controller. This may cause electric shock or injury. 3 Caution General â Do not use the speed controller beyond its specification, or electric shock, injury or damage to equipment may result. Installation â Keep the area around the speed controller free of combustible materials in order to prevent fire or burning. Operation â Use a speed controller and motor only in the specified combination. An incorrect combination may cause a fire. â Provide an emergency-stop device or emergency-stop circuit external to the equipment so that the entire equipment will operate safely in the event of a system failure or malfunction. Failure to do so may result in injury. â Before supplying power to the speed controller, set the Run/Stop input of the speed controller to STOP (ON position). Otherwise, the motor may start suddenly and cause injury or damage to equipment. â Immediately when trouble has occurred, stop running and turn off the speed controller power. Failure to do so may result in fire, electric shock or injury. â To prevent electric shock, use only an insulated screwdriver to adjust the internal speed potentiometer, acceleration time potentiometer and deceleration time potentiometer. Disposal â To dispose of the speed controller, disassemble it into parts and components as much as possible and dispose of individual parts/components as industrial waste. 4 â Warning indication Warnings are indicated on the cover of the speed controller. Always observe such information when handling the speed controller. Installation Location for installation The speed controller is designed and manufactured for installation in equipment. Install it in a well-ventilated location that provides easy access for inspection. The location must also satisfy the following conditions. Check ventilation if the ambient temperature of the speed controller exceeds 40°C (104°F). â Inside an enclosure that is installed indoors (provide vent holes) ambient temperature 0°C to +40°C ( +32°F to +104°F) (non-freezing) â Operating ambient humidity 85%, maximum (no condensation) â Area that is free from an explosive nature or toxic gas (such as sulfuric gas) or liquid â Area not subject to continuous vibration or excessive shocks â Area free of excessive electromagnetic noise ( from welders, power machinery, etc.) â Area free of radioactive materials, magnetic fields or vacuum â 1000 m or less above sea level â Operating How to install â Using screws Secure the speed controller with two screws (M4: not supplied) through the two mounting holes provided. Tightening torque: 0.7 N·m (99 oz-in) â Mounting to DIN rail Use a DIN rail 35 mm (1.38 in.) wide to mount the speed controller. When removing from DIN rail, use force of about 10 to 20 N ( 2.2 to 4.5 lb.) to pull the DIN lever. Installing and wiring in compliance with EMC directive â EMC directive (89/336/EEC, 92/31/EEC) The compliance of the final machinery with the EMC directive must be verified through EMC measures by the customer of the machinery. Applicable standards EMI Emission Tests Radiated Emission Test Conducted Emission Test EN61000-6-4 EN55011 EN55011 Immunity Tests Radiation Field Immunity Test Electrostatic Discharge Immunity Test Fast Transient/Burst Immunity Test Conductive Noise Immunity Test Surge Immunity Test Voltage Dip Immunity Test Voltage Interruption Immunity Test EN61000-6-2 IEC61000-4-3 IEC61000-4-2 IEC61000-4-4 IEC61000-4-6 IEC61000-4-5 IEC61000-4-11 IEC61000-4-11 EMS 5 â Installing and wiring âConnecting mains filter Connect a mains filter specified in the table below, or the equivalent, to the AC input line, in order to suppress the noise generated from the speed controller. TDK Corporation EPCOS AG Schaffner EMC Tyco Electronics CORCOM ZAG2210-11S B84112-B-B110 FN2330Y-10-06, FN2310X-10-06 10ESK1 Install the mains filter as close to the speed controller as possible, and use cable clamps and other means to secure the input and output cables firmly to the surface of the enclosure. Connect the ground terminal of the mains filter to the grounding point, using as thick and short a wire as possible. Do not place the AC input cable (AWG18: 0.75 mm2 or more) parallel with the mains-filter output cable (AWG18: 0.75 mm2 or more). Parallel placement will reduce mains-filter effectiveness if the enclosureâs internal noise is directly coupled to the power-supply cable by means of stray capacitance. âConnecting surge arrester Use a surge arrester or equivalent as below table. OKAYA ELECTRIC INDUSTRIES CO.,LTD. PHOENIX CONTACT GmbH & Co. KG RCM-601BQZ-4 VAL-MS 230VF ST NOTE â When measuring dielectric strength of the equipment, be sure to remove the surge arrester, or the surge arrester may be damaged. âMotor cable connection When the motor cable is extended, use a cable of AWG18 (0.75 mm2 ) or more with a length of 10 m (32.8 ft.) or less. When extending the rate generator lead wires, use a shielded cable. âWiring the control cable For the control cable for the speed controller, use a shielded cable as specified below, and keep it as short as possible [ 2 m (6.6 ft.) or less ]. â AWG28 (0.08 mm2 ) or more thickness of the insulator between the braided shield and lead-wire conductor shall be a minimum of 0.4 mm (0.016 in.). â Recommended strip length for shielded cable â The 4 mm (0.016 in.) min. Wire 6 Braided shield Insulation Sheath To ground a shielded cable, use a metal cable clamp or similar device that will maintain contact with the entire circumference of the shielded cable. Attach a cable clamp as close to the end of the cable as possible, and connect it to an appropriate grounding point as shown in the figure. Shielded cable Cable clamp âOthers â Connect the motor/speed controller and other peripheral control equipment directly to the grounding point so as to prevent a potential difference from developing between grounds. â When relays or electromagnetic switches are used together with the system, use mains filters and CR circuits to suppress surges generated by them. â Keep cables as short as possible without coiling and bundling extra lengths. â Place the power cables such as the motor and power-supply cables as far apart [100 to 200 mm (4 to 8 in.)] as possible from the control cables. If they must cross, do so at a right angle. Place the AC input cable and output cable of a mains filter separately from each other. âExample of motor and speed controller installation and wiring Motor Speed controller Motor cable [10 m (32.8 ft.)] Cable clamp Mains filter Surge arrester Control cable [2 m (6.6 ft.)] Cable clamp Power cable Capacitor Grounded panel 7 Connection and operation Connect the speed controller to the power supply, motor and switches according to the following procedure: 1. Loosen the cover screw (M4, one location) at the center of the cover, and remove the cover. 2. Connect each terminal. 3. Install the cover and secure it with the cover screw (M4, one location). Tightening torque: 0.7 N·m (99 oz-in) See âInstalling and wiring in compliance with EMC directiveâ on page 5 for measures with regard to noise. Names and function of parts 1 2 3 4 The illustration has the cover removed. Install the cover after connection. 1 POWER LED 5 Turns on (green) while power is being supplied. 2 Internal speed potentiometer Set the motor s operating speed. 3 Acceleration time potentiometer LED1 VR2 VR3 VR1 TB3 Set the acceleration time for motor startup. S1 S2 S3 S4 S5 S6 POWER SPEED ACCEL DECEL INT-VR STOP Set the deceleration time for motor stop. EXT-VR BRAKE Installation hole G 7 8 10 NC 11 BLU BLU 1 2 3 4 FG N L BLK 5 6 RED WHT MOTOR 8 4 Deceleration time potentiometer 5 Control input terminal S1 Common terminal for running and braking S2 Run/Stop input Runs (OFF) or stops (ON) the motor. S3 Run/Brake input Runs (OFF) or brakes (ON) the motor. Installation S4, S5, S6 Speed potentiometer inputs When S4 and S5 are shorted, the speed hole can be set using the internal speed potentiometer (INT-VR). When S4 and S5 are open, the speed can be set using an external speed 9 potentiometer (EXT-VR). When using an external speed potentiometer, connect it to S4 and S6. 6 Power connection terminal (terminals 2 and 3) 7 10 6 DIN lever 7 Motor connection terminal (terminals 4, 5 and 6) Connect the black motor lead wire to terminal 4. When the red motor lead wire is connected to terminal 5 and the white motor lead wire to terminal 6, the motor will rotate in the clockwise direction, as seen from the motor s output-shaft side. When the white motor lead wire is connected to terminal 5 and the red motor lead wire to terminal 6, the motor will rotate in the counterclockwise direction, as seen from the motor s output-shaft side. 8 Terminals 7 and 8 Connect the capacitor only when the uni-directional operation. 9 Generator connection terminal (terminals 10 and 11) Connect the blue generator lead wires. 8 10 FG terminal (terminal 1) Connecting the terminal of the motor and power supply 3.7 ( 0.146) min. 9 (0.354) min. (Ring terminal with insulation) [Unit: mm (inch)] 7.8 (0.276) max. Appropriate crimp terminal 7.8 (0.276) max. Terminal screw size: M3.5 Screw tightening torque: 1 N·m (8.8 lb-in) 3.7 (0.146) min. 9 (0.354) min. (Fork terminal with insulation) Connecting the control input terminal Applicable lead wire diameter: AWG28 ~16 (0.08 ~ 1.5 mm2 ) Length of the lead wire which can be stripped: 5 ~ 7 mm (0.2 ~ 0.28 in.) Tightening torque: 0.22 ~ 0.25 N·m (31~ 35 oz-in) Flat blade-parallel tip type driver Tip thickness 0.3 ~ 0.4 mm (0.01~ 0.02 in.) Tip width 2 ~ 2.5 mm (0.08 ~ 0.1 in.) Connection example NOTE â Solenoids, high-frequency power sources and electric welders may cause the speed controller to malfunction. Use an independent power source for the speed controller, and separate the control and power lines. Specifications of the switches and fuse Power supply / Voltage SW1 SW2, SW3 SW4 200 V/220 V/230 V (ES02) 100 V/110 V/115 V (ES01) 125 VAC 10 A 250 VAC 5 A 18 VDC 1 mA 125 VAC 10 A 250 VAC 5 A R0, C0 R0= 5 ~ 200 ⊠C0= 0.1 ~ 0.2 µF, 200 WV R0= 5 ~ 200 ⊠C0= 0.1 ~ 0.2 µF, 400 WV Product certified under the UL/CSA248-14 standard or equivalent 250 VAC 10 A Product certified under the UL/CSA248-14 standard or equivalent 250 VAC 5 A (Surge suppressor) Fuse NOTE â The control input terminals are not insulated from the AC power supply. Any equipment (programmable controller, relay and/or switch) that will be connected to the control input terminals must have contact ratings of 18 VDC and 1 mA min. Provide reinforced insulation for the parts which are in direct contact with human operators. â Do not connect a controller that uses transistor output. 9 â Uni-directional operation (when using the internal speed potentiometer) Run SW3 SW2 Brake Run Stop LED1 VR2 VR3 VR1 TB3 S1 S2 S3 S4 S5 S6 POWER SPEED ACCEL DECEL INT-VR STOP EXT-VR BRAKE G 7 8 10 NC 2 AWG18(0.75 mm ) min. Capacitor ES01 100 VAC 110 VAC 115 VAC ES02 200 VAC 220 VAC 230 VAC 11 BLU BLU 1 2 3 4 5 6 FG N L BLK RED MOTOR WHT Motor AWG18(0.75 mm2 ) min. Blue Blue Frame ground 50/60 Hz Fuse 60 Hz 60 Hz Power supply AWG18(0.75 mm2 ) min. SW1 50/60 Hz 50/60 Hz 50/60 Hz White Red Black Orange â Orange â â These are lead wires for the cooling fan. These should be connected only when using 60 W and 90 W types. â The length of the cable connecting the motor and speed controller should be no more than 10 m (32.8 ft.). â The length of the control cable should be no more than 2 m (6.6 ft.) and as short as possible. â Refer to page 9 about the specifications for the switches and fuse. â To ground a motor, what has equipped the protective earth terminal should use a protective earth terminal. 10 â Bi-directional operation (when using the internal speed potentiometer) Run SW3 SW2 Brake Run Stop LED1 VR2 VR3 VR1 TB3 S1 S2 S3 S4 S5 S6 POWER SPEED ACCEL DECEL INT-VR STOP EXT-VR BRAKE G 7 8 10 NC 11 BLU BLU 1 2 3 4 5 6 FG N L BLK RED MOTOR WHT AWG18(0.75 mm2 ) min. Frame ground ES01 100 VAC 50/60 Hz Fuse 110 VAC 60 Hz 115 VAC 60 Hz Power supply AWG18 ES02 2 SW1 (0.75 mm ) min. 200 VAC 50/60 Hz 220 VAC 50/60 Hz 230 VAC 50/60 Hz Blue Co Blue Ro CW Motor CCW Co Ro â The length of the cable connecting Co Ro the motor and speed controller CW SW4 should be no more than CCW 10 m (32.8 ft.). Co Ro â The length of the control cable should be no more than 2 m (6.6 ft.) and as short as possible. â Refer to page 9 about the specifications for the switches, fuse, and surge suppressor. â To ground a motor, what has AWG18 equipped the protective earth termi- (0.75 mm2 ) min. nal should use a protective earth terminal. Capacitor White Red Black Orange â Orange â â These are lead wires for the cooling fan. These should be connected only when using 60 W and 90 W types. NOTE â Be sure to connect a surge suppressor to SW4. Failure to do so may damage the speed controller. Oriental Motor also provides an optional EPCR1201-2 CR circuit for surge suppression. 11 Operation The timing chart below shows an example of switching between two speed levels when the high speed and low speed are selected via the internal and external speed potentiometers, respectively (see page 15). Switching between two speed levels/Stop Run/Stop immediately High speed â Acceleration/ 1 Deceleration operation High speed Low speed CW (Clockwise direction) Motor operation CCW (Counter-clockwise direction) Power supply SW3 Run/Stop input OFF â2 OFF ON â SW2 2 OFF Run/Brake input SW4 CW/CCW input ON Internal/ External speed setting â1 â2 Low speed ON SW1 CW CCW INT EXT Run Stop Run Stop 0.5s min. Run Brake Run CW CCW Internal External Brake Run CW Internal External Internal Case where the acceleration and deceleration times are set longer by turning each potentiometer clockwise. If SW2 and SW3 are turned to ON simultaneously, the brake input will take priority. NOTE â The braking function (current through the motor) is only active for approximately 0.4 seconds after the Run/Brake input is turned ON. Do not switch any switches for 0.5 second after turning the Run/Brake input to ON. Otherwise, damage to the speed controller may result. â Run /Brake, Stop Setting SW2/SW3 to âRunâ (OFF) causes the motor to Run/Stop input Run/Brake input rotate at the speed set via the speed potentiometer. OFF OFF Setting SW2 to âBrakeâ (ON) during operation OFF ON causes the motor to stop immediately. Setting SW3 to âStopâ (ON) during operation ON OFF causes the motor to coast to a stop. Motor operation Runs Stops immediately Coasts to a stop â Switching the direction of rotation SW4 is used to switch the motorâs direction of rotation. When SW4 is set to CW, the motor rotates in the clockwise direction, as seen from the motorâs outputshaft side. When SW4 is set to CCW, the motor rotates in the counterclockwise direction, as seen from the motorâs output-shaft side. The rotating direction of the gear output shaft is opposite that of the motor shaft, depends on the gear ratio. NOTE â Be sure to connect a surge suppressor to SW4. Failure to do so may damage the speed controller. Oriental Motor also provides an optional EPCR1201-2 CR circuit for surge suppression. â Instant switching between forward and reverse operations is possible with a reversible motor. bi-directional operation of an induction motor, switch the rotating direction after the motor has come to a complete stop. â For 12 â Setting the speed 2000 60 Hz 50 Hz 1500 Speed [r/min] Use the internal speed potentiometer. The setting range is from 90 to 1400 r/min at 50 Hz or 90 to 1600 r/min at 60 Hz. Short the speed potentiometer input terminals S4 and S5. Turning the potentiometer clockwise will set a faster speed. The factory setting is 0 r/min. 1000 500 0 10 2 4 0 6 8 10 Internal speed potentiometer position Internal speed potentiometer Internal speed potentiometer positionspeed characteristics (typical value) Use a supplied external speed potentiometer when setting the speed remotely from the speed controller or controlling the speed over two or more levels. See pages 14 and 15. Acceleration and deceleration operation The acceleration/deceleration time can be adjusted to prevent the load from receiving a shock upon starting, stopping or a change in speed. For adjustment, use the acceleration time potentiometer and deceleration time potentiometer. The setting range is approx. 0.5 to 10 seconds (at 1000 r/min, with no inertial load). If a significant amount of load inertia is applied, the deceleration time cannot be set shorter than the time needed for a natural stop. â Acceleration 0 15 Acceleration time [sec /1000 r /min] The acceleration function is actuated at start or when the speed is switched to the higher setting in a two-level speed control. Turning the acceleration time potentiometer clockwise will increase the set time. The factory setting is 0 (no acceleration). 10 5 10 Acceleration time potentiometer 0 2 4 6 8 10 Acceleration time potentiometer positionspeed characteristics (typical value) 13 â Deceleration 20 0 Deceleration time [sec / 1000 r / min] The deceleration function is actuated at natural stop or when the speed is switched to the lower setting in a two-level speed control. Turning the deceleration time potentiometer clockwise will increase the set time. The factory setting is 0 (no deceleration). 15 10 5 10 0 Deceleration time potentiometer 2 4 6 8 10 Deceleration time potentiometer positionspeed characteristics (typical value) Setting the speed by using an external speed potentiometer Open the speed potentiometer input terminals S4 and S5. Before connecting, turn the dial on the external speed potentiometer counterclockwise to set the speed to 0 r/min. Turning the dial clockwise will set a faster speed. External speed potentiometer 20 k 1/4 W with a linear resistance vs. angle curve 2000 60 Hz Speed [r/min] 1 1 50 Hz 3 1500 3 2 1000 500 0 5 10 15 20 Speed potentiometer resistance [k ] TB3 S1 S2 S3 S4 S5 External speed potentiometer resistancespeed characteristics (typical value) S6 NOTE â Do not operate multiple speed controllers with a single external speed potentiometer. Doing so may damage the speed controllers. 14 â Mounting the external speed potentiometer 1. Insert the insulated sheet and potentiometer into the hole of the mounting plate, as illustrated below. 2. Insert the dial plate and toothed washer in position and lock them with nuts. Tightening torque: 0.45 N·m (63 oz-in) max. 3. Mount the knob and lock it using the set screw (M4). Tightening torque: 0.4 N·m (56 oz-in) max. Potentiometer Insulated sheet Mounting plate Dial plate Set screw 50 60 7.5 70 40 0.4 (0.295 0.016) 80 30 90 0 10 20 Knob 10 0 3 (0.118) Hexagon nut Toothed washer 10 (0.394) Mounting hole dimensions [Unit: mm (inch)] â Soldering the external speed potentiometer terminal Wind the lead wire into the terminal hole two or three turns, and cover the soldered area with a heat shrink tube. â Two-level speed control The motor can be controlled over two speed levels by switching between the internal and external speed potentiometers. Setting SW (speed-setting selection) selects the internal speed potentiometer or external speed potentiometer. External Internal 1 2 External speed potentiometer 3 NOTE â The TB3 S1 S2 S3 S4 S5 S6 control input terminals are not insulated from the AC power supply. Any equipment (programmable controller, relay and/or switch) that will be connected to the control input terminals must have the contact ratings of 18 VDC and 1 mA min. Provide reinforced insulation for the parts directly contacted by human operators. 15 Repeated operation/braking cycle When running/braking of the motor is repeated in short cycles, the rise in motor temperature will increase and the continuous-operation time will be limited. Use the following values as a guideline: Motor output 6 ~ 40 W 60 W, 90 W Repetition cycle 2 seconds min. (Running 1 second, stopping 1 second) 4 seconds min. (Running 2 seconds, stopping 2 seconds) Braking current When the motor is commanded to stop immediately, the following braking current will flow. Provide an appropriate power supply by referring to these values. Motor output 6 15 25 40 60 90 W W W W W W Braking current (Peak value) [A] Single-phase 100 V / 110 V / 115 V Single-phase 200 V / 220 V / 230 V 1.5 1.0 3.5 2.0 5.5 4.0 8.5 6.0 15.5 8.0 20.5 12.0 Inspection It is recommended that periodic inspections be conducted for the items listed below after each operation of the speed controller. If an abnormal condition is noted, discontinue its use and contact your nearest office. â Are any of the speed controller mounting screws or power connection terminal screws loose? a relay or switch is used, check its contact for wear or melting. â When 16 Troubleshooting and remedial actions During motor operation, the motor or speed controller may fail to function properly due to an improper speed setting or wiring. When the motor cannot be operated correctly, refer to the contents provided in this section and take appropriate action. If the problem persists, contact your nearest office. Certain items must be checked with the power on. Be careful not to touch any live connections. Phenomenon Possible cause The motor fails to turn. The Run/Stop input or The speed doesnât Run/Brake input is set to ON. change. The internal speed potentiometer or external speed potentiometer is not adjusted. Remedial action Set the Run/Stop input or Run/Brake input to OFF. Turn the internal speed potentiometer or external speed potentiometer in the clockwise direction. The speed is set to 0 r/min at time of shipment. The speed potentiometer input terminals S4 and S5 are not shorted when the internal speed potentiometer is used. Short the speed potentiometer input terminals S4 and S5. The external speed potentiometer contact is faulty. Check for connection of the external speed potentiometer. The speed potentiometer input terminals S4 and S5 are not open when the external speed potentiometer is used. Open the speed potentiometer input terminals S4 and S5. Unstable motor operation with big vibration Affected by noise If noise influence has been confirmed, take the appropriate measures such as separation from noise generating source and reconnection of wiring. See pages 5~7 for measures with regard to noise. The motor doesnât start instantaneously. The acceleration time potentiometer is active. Turn the acceleration time potentiometer counterclockwise until it stops. Load inertia may be excessive. For this check, reduce the load inertia. Load inertia may be excessive. For this check, increase the frictional load or reduce the load inertia. If a relay or switch is used, its contact has melted. Check the relay/switch. The motor is stopped by the Operation/Stop input (coast to a stop). Stop the motor via the Operation/Brake input. Load inertia may be excessive. For this check, increase the frictional load or reduce the load inertia. The motor doesnât reverse its direction instantly. The motor fails to stop instantaneously. 17 â Unauthorized reproduction or copying of all or part of this manual is prohibited. If a new copy is required to replace an original manual that has been damaged or lost, please contact your nearest Oriental Motor branch or sales office. â Oriental Motor shall not be liable whatsoever for any problems relating to industrial property rights arising from use of any information, circuit, equipment or device provided or referenced in this manual. â Characteristics, specifications and dimensions are subject to change without notice. â While we make every effort to offer accurate information in the manual, we welcome your input. Should you find unclear descriptions, errors or omissions, please contact the nearest office. â is a registered trademark or trademark of Oriental Motor Co., Ltd., in Japan and other countries. Other product names and company names mentioned in this manual may be registered trademarks or trademarks of their respective companies and are hereby acknowledged. The thirdparty products mentioned in this manual are recommended products, and references to their names shall not be construed as any form of performance guarantee. Oriental Motor is not liable whatsoever for the performance of these third-party products. © Copyright ORIENTAL MOTOR CO., LTD. 2008