Download EonStor A12F-G2221
Transcript
EonStor A12F-G2221 Fibre to SATA RAID Subsystem åæ±èª¬ææž ã³ã¢ãã€ã¯ãã·ã¹ãã ãºæ ªåŒäŒç€Ÿ Revision 1.1 A12F-G2221 åæ±èª¬ææž ã¯ããã« ãã®åºŠã¯ãEonStor A12F-G2221 ããè²·äžãããã ããŸããŠèª ã«ããããšãããããŸããæ¬æž ã§ã¯ãåºæ¬çãªåæ±ãæ¹æ³ã泚æäºé ãæ©èœåã³ä»æ§ã«ã€ããŠèšè¿°ããŠãããŸãã®ã§ãã 䜿çšåã«ãäžèªãããŸããããé¡ãããããŸãã ãŸãã³ã³ãããŒã©æ©èœã®è©³çްã¯ä»å± CD-ROM ã® Generic Manual ïŒGMN.x.xx.pdfïŒïŒãåç §é¡ ããŸãã ãæ³šæ â æ¬æžã®äžéšãŸãã¯å šéšãåŒç€Ÿã«ç¡æã§è»¢èŒããããšã¯çŠæ¢ãããŠãããŸãã â¡ æ¬æžã®å 容ã«ã€ããŠã¯äžå šãæããŠãããŸãããäžäžãäžå¯©ã®ç¹ãããããŸããããåŒç€Ÿãã¯ãã«ã«ãµããŒããŸã§ãé£ çµ¡ãã ãããŸããããé¡ãããããŸããæ¬è£œåããã³æ¬æžãéçšããçµæã«ããæå€±ãå©çã®éžå€±ã®è«æ±çã«ã€ããŸã㊠ã¯ãåŒç€Ÿã§ã¯ãããªã責任ãè² ããããŸãã®ã§ãããããããäºæ¿äžããã â¢ æ¬æžã«èšèŒãããŠããæ©çš®åããœãããŠã§ã¢ã®ããŒãžã§ã³ãªã©ã¯ãæ¬æžãäœæããæç¹ã§ç¢ºèªãããŠããæ å ±ã§ããæ¬æž äœæåŸã®ææ°æ å ±ã«ã€ããŠã¯ãåŒç€Ÿãã¯ãã«ã«ãµããŒããŸã§ãåãåããäžããã ⣠æ¬è£œåã®ä»æ§ããã¶ã€ã³ããã³ããã¥ã¢ã«ã®å 容ã«ã€ããŠã¯ãè£œåæ¹è¯ãªã©ã®ããã«äºåãªã倿Žããå Žåããã㟠ãã †æ¬è£œåã䜿çšããŠåçŽããããŒã¿ããããŒããŠãšã¢ã®æ éã誀åäœããã®ä»ã©ã®ãããªçç±ã«ãã£ãŠç Žå£ãããå Žåã§ãã åŒç€Ÿã§ã®ä¿èšŒã¯ããããããŸããäžäžã«åããŠãéèŠãªããŒã¿ã¯ãããããŒãã£ã¹ã¯ã3.5 ã€ã³ãå ç£æ°ãã£ã¹ã¯ãã㌠ãããã¯ã¢ããè£ çœ®ãä»ã®ãã£ã¹ã¯è£ 眮ãªã©ã«ãããããããã¯ã¢ããããããã«ãé¡ãããããŸãã ⥠æ¬è£œåã¯ã人åœã«é¢ããèšåãæ©åšãããã³é«ãä¿¡é Œæ§ãå®å šæ§ãå¿ èŠãšããèšåãæ©åšïŒå»çé¢ä¿ãèªç©ºå®å®é¢ä¿ã 茞éé¢ä¿ãåååé¢ä¿çïŒãžã®çµã¿èŸŒã¿çã¯èæ ®ãããŠããŸããããããã®èšåãæ©åšã§æ¬è£œåã䜿çšããããšã«ãã äººèº«äºæ ãè²¡ç£æå®³çãçºçããŠãåŒç€Ÿã§ã¯ãããªã責任ãè² ããããŸãã ⊠æ¬è£œåã¯æ¥æ¬åœå 仿§ã§ãã®ã§ãæ¬è£œåãæ¥æ¬åœå€ã§äœ¿çšãããå ŽåãåŒç€Ÿã§ã¯ãããªã責任ãè² ããããŸãããŸãã åŒç€Ÿã§ã¯æµ·å€ã§ã®ãµãŒãã¹ããã³æè¡ãµããŒããè¡ã£ãŠãããŸããã ïŒ æ¬æžã«èšèŒãããŠããããœã³ã³ã®æ©çš®åããœãããŠã§ã¢ã®åç§°çã¯å瀟ã®åæšãŸãã¯ç»é²åæšã§ãã 2/57 A12F-G2221 åæ±èª¬ææž å®å šã«ã䜿ããã ãããã« æ¬è£œåãå®å šã«æ£ããã䜿çšããã ãããã«ããã®ããã¥ã¢ã«ã«ã¯å®å šè¡šç€ºã䜿çšããŠããŸãã ãããã®èšèŒäºé ã¯å®å šã®ããã«å¿ ããå®ããã ãã 絵衚瀺ã«ã€ã㊠æ¬è£œåãæ£ããã䜿çšé ããããªããä»ã®äººã ãžã®å±å®³ã財ç£ãžã®æå®³ãæªç¶ã«é²æ¢ããããã«ããã®ã ãã¥ã¢ã«ããã³æ¬è£œåãžã®å®å šè¡šç€ºã«ã€ããŠã¯ã以äžã®çµµè¡šç€ºãããŠããŸã å±éº ãã®è¡šç€ºãç¡èŠããŠèª€ã£ãåãæ±ãããããšãäººã®æ»äº¡ãŸãã¯éå·ãè² ãå¯èœæ§ãããå± éºãååšããå 容ã瀺ããŠããŸãã æ³šæ ãã®è¡šç€ºãç¡èŠããŠèª€ã£ãåãæ±ãããããšã人ãæå®³ãè² ãå¯èœæ§ãæ³å®ãããå 容㟠ãã¯ç©ççæå®³ã®çºçãæ³å®ãããå 容ã瀺ããŠããŸãã éèŠ è£ çœ®ã®æ éã»æå·ã誀ã£ãæäœãé²ãããã«ãæäœäžå¿ ãå®ã£ãŠããã ãããéèŠäº é ãå¶éäºé ã瀺ããŠããŸãã å±éºïŒæ³šæã©ãã«è¡šç€ºã«ã€ã㊠æ¬è£œåã®å€éšãŸãã¯å éšã«é»è²å°ã«é»æåã§è¡šç€ºãããŠããã©ãã«ããããšãã¯ãå®å šã«é¢ããŠå±éºãŸãã¯æ³šæã®ã©ãã«ã§ ããå¿ ãè¡šç€ºã®æç€ºã«åŸã£ãŠãã ããã ãã®ããã¥ã¢ã«ã«èšèŒãããŠãã以å€ã«å±éºãŸãã¯æ³šæã©ãã«ã«ãã衚瀺ããããšãã¯ïŒäŸãã°è£œåäžã«ïŒãå¿ ããã®ã©ãã« ã«ããæç€ºã«åŸã£ãŠãã ããã å±éº 髿ž©ã«ãªãå Žæã湿æ°ã®å€ãå Žæã§ã¯äœ¿çšããªãã§ãã ãããç«çœãæé»ã®æãããããŸããæ¬è£œåã®åäœç°å¢æž©åºŠã¯ ïŒïŒââŒïŒïŒâã§ãã æ¬è£œåã®éæ°åããµãããªãã§ãã ãããå éšã«ç±ãããããç«çœã®åå ãšãªããŸããæ¬è£œåã¯åé¢ããåžæ°ãåŸéšããæ æ°ããŸãã®ã§ãç¹ã«ååŸã®éæ°ã«ã¯ã泚æãã ããã空æ°ãæ£ãã埪ç°ããããã«ãæ¬è£œåã®é颚å£ããïŒcm 以äžã®ã¹ã ãŒã¹ã空ããŠãã ããã æ¬è£œåããã³åãŠãããã¯çµ¶å¯Ÿã«åè§£ã»ä¿®çã»æ¹é ãããªãã§ãã ããã å éšã«ã¯é«é»å§ã®éšåããããç«çœãæé»ã® æãããããŸãã æ¬è£œåãã©ãã¯ã«èšçœ®ããå Žåã¯ãã¬ãŒã«ãã©ãã¯ã®æ£æ¿çã«ãã確å®ã«åºå®ã§ããŠããããšã確èªããŠãã ããã åé¢ã ãã«ã®ããžæ¢ãã ãã§æ¬äœãæ¯ããå Žåã¯ãæ¯åã®çºçã«ããæ§èœå£åã補åã®èœäžã«ããæªæã®å¯èœæ§ããããŸã ã®ã§çµ¶å¯Ÿã«é¿ããŠãã ããã 3/57 A12F-G2221 åæ±èª¬ææž æ¬è£œåãåãæ±ãå Žåã¯ãå®å šã®çºã«ã鿢±ã»æ¢±å ã»èšçœ®æã«ã¯ 2 å以äžã§äœæ¥ãè¡ã£ãŠãã ããã æ¬è£œåã«ã±ãŒãã«é¡ãæãå·®ãããå Žåã«ã¯ãæ¬è£œåããã³æ¥ç¶ãããæ©åšã®é»æºãå¿ ãåæããŠè¡ã£ãŠãã ãããã± ãŒãã«ã®ç Žæã«ããç«çœãæé»ã®æãããããŸãã æ¬è£œåã®å éšã«ç°ç©ïŒéå±ãŸãã¯æ°Žãæ¶²äœãªã©ïŒãå ¥ã£ãå Žåã¯ãããã«æ¬è£œåã®é»æºã鮿ããå¿ ãã³ã³ã»ã³ãããé» æºã±ãŒãã«ãæããŠãã ããããã®ãŸãŸäœ¿çšãããšã補åå éšã§ã·ã§ãŒãããŠãç«çœãæé»ã®åå ã«ãªããŸãã 黿ºã±ãŒãã«ããã®ä»ã®ã±ãŒãã«é¡ãç¡çã«æ²ããããããã£ããããªãã§ãã ããããŸãå·ã€ãããããªãã§ãã ããã ã±ãŒãã«è¢«èŠã®çµ¶çžå£åãè¯ç·ã®é²åºãæç·ã«ããç«çœãæé»ã®åå ã«ãªããŸãã 黿ºã±ãŒãã«ãã³ã³ã»ã³ãããæããšãã¯ãå¿ ã黿ºãã©ã°éšåãæã£ãŠæããŠãã ããã ã±ãŒãã«ãåŒã£åŒµããšã±ãŒã ã«ã®æç·ãã·ã§ãŒãã«ããç«çœãæé»ã®åå ã«ãªããŸãã ã©ãã¯ãã£ããããã®é»ååé è£ çœ®ãïŒç¡åé»é»æºè£ 眮ïŒã®ã¹ã€ããããªã³ã«ãªã£ãŠããå Žåããããã«æ¥ç¶ãããŠã ã黿ºã±ãŒãã«ã«ã¯é»æµãæµããŠããŸããæ¬è£œåãå®å šã«ãã£ããããã«åãä»ãããããã¹ãŠã®ã±ãŒãã«é¡ãæ¥ç¶ã ãããŸã§ãæ¬è£œåã®é»æºãŠãããã«é»æºã±ãŒãã«ãæ¥ç¶ããªãã§ãã ããã ã³ã³ã»ã³ãã®é ç·ãæ£ãããªããšãã·ã¹ãã ããŸãã¯ãã®ã·ã¹ãã ã«æ¥ç¶ããã補åã®éå±éšåã«å±éºãªé»å§ãçºçãã ããšããããŸãã ã³ã³ã»ã³ãã¯å¿ ãïŒP ã¢ãŒã¹ä»ããã䜿çšãã ããã é·éšã®éã¯é»æºã±ãŒãã«ãã±ãŒãã«é¡ã®æãå·®ãããŸãã¯æ¬è£œåã®èšçœ®ãä¿å®ãåæ§æãè¡ããªãã§ãã ãããæé»ã® åå ãšãªããŸãã åãŠããããåãåºããéšåã«ãæãéå±è£œã®ããŒã«ãå·®ã蟌ãŸãªãã§ãã ããã æ³šæ æ¬è£œåã®åãä»ããŸãã¯åãå€ãäžã«ãã£ãããããåã«åããããšãé²ãããã«ããã£ããããåºé¢ã®åéšã«å®å®åšå ·ã æ£ããåãä»ããŠãã ãããå®å®åšå ·ãåãä»ããŠããªãå Žåããã£ãããããåããŠãããããäºããããŸãã ã©ãã¯ã«åãä»ããéã«ã¯ãæªæé²æ¢ã®çºãå¿ ãæè¢ã䜿çšããŠãã ããã 亀æå¯èœãªããããªãåè§£ããªãã§ãã ãããããããªã®çºç±ãç Žè£ã®åå ãšãªããŸãã 亀æå¯èœãªããããªãç«æ°ã«è¿ã¥ããããå ç±ããªãã§ãã ãããç Žè£ã®åå ãšãªããŸãã 亀æå¯èœãªããããªã®é»æ¥µã®ïŒïŒïŒç«¯åïŒâïŒç«¯åãéå±ãªã©ã§ã·ã§ãŒããããªãã§ãã ããã ããããªã®çºç±ãç Žè£ã®å å ãšãªããŸãã 亀æå¯èœãªããããªãæ°ŽãŸãã¯éšã«ããããªãã§ãã ãããããããªã®çºç±ãè é£ã®åå ãšãªããŸãã æ¥æ¿ã«æž©åºŠå·®ãäžãããšãæ©åšãçµé²ããŠæ éã®åå ãšãªããŸããçµé²ãããªãããã«ã泚æãã ãããäžäžãçµé²ãã㊠ããŸã£ãå Žåã¯ãïŒæéä»¥äžæŸçœ®ããå®å šã«ä¹Ÿããããšã確èªããŠããã䜿çšãã ããããã ããã®å Žåã®æ£åžžåäœã®ä¿èšŒ ã¯ã§ããŸããã ãã¬ããã¹ããŒã«ãŒçã匷ãé»ç£æ°ãçºçããé»åæ©åšã®è¿ãã«çœ®ããªãã§ãã ããã誀åäœãæ éã®åå ãšãªããŸãã ç§»åããå Žåã¯ãå¿ ã黿ºãåããæ¯åãè¡æãäžããªãããã«ããŠãã ããã 誀åäœãæ éã®åå ãšãªããŸããç§»åã ãå Žåã«ã¯å°ç𿢱å ç®±ã®ã䜿çšããå§ãããŸãã 亀æå¯èœãªããããªã廿£ããå Žåã¯ã端åã«ããŒãã貌ãä»ãããªã©çµ¶çžå¯Ÿçãè¡ã£ãåŸãåœè©²å°åã®é¢é£æ³èŠãäŒ ç€Ÿã®å®å šåºæºã«åŸã£ãŠè¡ã£ãŠãã ãããçŒåŽããããã¿ããã¿åç«å°ã«åãããããã¿ã«ã¯ã絶察ã«å ¥ããªãã§ãã ã ãã 黿ºãŠãããã®äº€æäœæ¥ãããåã«ãæ éãã黿ºãŠããããã黿ºã±ãŒãã«ãåãå€ãããŠããã 黿ºããªãã«ãª ã£ãŠããããšã確èªããŠãã ããã æ¬è£œåã«ã¯ãã客æ§ã®å®å šã®ããã«ïŒç·åŒã®é»æºã±ãŒãã«ãæ·»ä»ãããŠããŸããæé»äºæ 鲿¢ã®ããã«ããã®é»æºã± 4/57 A12F-G2221 åæ±èª¬ææž ãŒãã«ãšæ£ããã¢ãŒã¹ç·ã®æ¥ç¶ãããã³ã³ã»ã³ãã䜿çšããŠãã ããã ç§»åããå Žåã¯ãå¿ ã黿ºãåããæ¯åãè¡æãäžããªãããã«ããŠãã ããã誀åäœãæ éã®åå ãšãªããŸããç§»åãã å Žåã«ã¯å°ç𿢱å ç®±ã®ã䜿çšããå§ãããŸãã æ¬è£œåãæã¡äžããéã«ããã©ã€ããŠãããã®ã¬ããŒããã¡ã³ã黿ºã¢ãžã¥ãŒã«ã«åãä»ããŠãããã³ãã«ã䜿çšããŠæ ã¡äžããªãããã«ããŠãã ããããããã®ãã³ãã«ã¯ãæ¬è£œåã®ééãæ¯ããç®çã§åãä»ããããŠããããã§ã¯ãããŸã ãã æ¬è£œåãæ¯åãè¡æã®çºçããå Žæã§äœ¿çšããªãã§ãã ããã誀åäœãæ éã®åå ãšãªããŸãã æ¬è£œåã«å¯Ÿãæ¥æ¿ãªæž©åºŠå·®ãäžãããšãæ©åšãçµé²ããŠããŸãæ éã®åå ãšãªããŸããäžäžãçµé²ãããŠããŸã£ãå Žåã« ã¯ããã°ããæŸçœ®ããæ©åšãå®å šã«ä¹Ÿããããšã確èªããŠããã䜿çšãã ããããã ãããã®å Žåã®è£œåã®åäœä¿èšŒã¯ä¿èšŒ 察象å€ãšãªããŸãã æ¬è£œåããã¬ãããã¹ããŒã«ãŒãªã©ã®åŒ·åãªé»ç£æ°ãçºçããé»åæ©åšã®è¿ãã«èšçœ®ããªãã§ãã ããã誀åäœãæ é ã®åå ãšãªããŸãã æ¬è£œåã®é»æºããªã³ã®ç¶æ ã§ãæ éããŠããªããã©ã€ããåŒãæããªãã§ãã ãããéé»ã®ç¶æ ã§ãã©ã€ããåŒãæããšã ãã¡ãŒã ã»ãŠã§ã¢ããããæ€ç¥ãããã©ã€ãã»ãŠããããæ éãšããŠæ±ããŸããããã«åäœäžã®æ£åžžãªãã©ã€ããŠããããåŒã æããå Žåããã©ã€ãå éšã®ãããããã£ã¹ã¯ã«ä¿®åŸ©äžå¯èœãªãã¡ãŒãžãäžããæ éã®åå ãšãªããŸãã æ¬è£œåã鿢±ããã³ç§»ååŸã«äœ¿çšããå Žåã«ã¯ã誀åäœãé¿ããããã黿ºãæå ¥ããåã«ãã©ã€ããŠããããïŒå°ã〠æŒã蟌ãã§ãã ããããã©ã€ãã»ãŠããããæãããã£ãŠããå Žåããã誀åäœããåå ãšãªããŸãã æ¬è£œåã«ã¯åäœç¢ºèªããåæåããããã©ã€ãã䜿çšããŠããŸãã亀æéšåãšããŠçšæããããã£ã¹ã¯ã»ã¢ãžã¥ãŒã«ä»¥å€ã® ãã©ã€ããã容éãã¡ãŒã«ãŒãåçªãåãã§ãã£ãŠãããèªåã§è³Œå ¥ããŠäº€æããªãã§ãã ããã çæéã«é»æºã®ãªã³ã»ãªããç¹°ãè¿ããªãã§ãã ããã容éã®å€§ããªãã©ã€ãã¯å éšã®ãã£ã¹ã¯ã®ææ°ãå€ãããã®åè»¢ã æ¢ãŸããŸã§ã«æéãããããŸããçãéã«é»æºã®ãªã³ã»ãªãããããšãæ¢ãŸãããããã£ã¹ã¯ã®å転ãå床å§ããããšã«ãªãã ãã©ã€ãã®ã¹ãã³ãã«ã»ã¢ãŒã¿ãŒããããçã«ãã¡ãŒãžãäžãã寿åœãçãããæãããããŸãã黿ºããªãããå Žåããã© ã€ãå éšã®ãã£ã¹ã¯ã忢ããã®ã«ãããååãªæéïŒçŽ 15 ç§ïŒããããŠããã黿ºããªã³ããŠãã ãããäžäž æ£åžžãªã ã©ã€ããåãå€ããšããåæ§ã«ã黿ºããªãããŠããååãªæéããããŠããåãå€ããŠãã ããã ãã©ã€ãé害ãçºçãããªãã«ãåäœãå®è¡äžã«é»æºã®ãªã³ã»ãªããè¡ããªãã§ãã ããã ãã©ã€ããžã®æžã蟌ã¿äžã«é»æºãèœã¡ãŸããšãã©ã€ãå ã®ããŒã¿ããã©ã€ãèªèº«ãå£ããå ŽåããããŸãã éèŠ åé»çã«ãã£ãŠãããŒã¿ãæ¶å€±ããŠããŸãå¯èœæ§ããããŸãã®ã§ã éçšæã«ã¯ãããŒã¿ã®ããã¯ã¢ããåã³ç¡åé»é»æºïŒUPSïŒã®äœ¿çšã匷ããå§ãããŸãã 5/57 A12F-G2221 åæ±èª¬ææž èšçœ®ç°å¢ã®ã泚æ â åšå²æž©åºŠ æ¬è£œåã®äœ¿çšæž©åºŠç¯å²ã¯10ââŒ35âã§ãã æ¬è£ 眮ãèšçœ®ããå Žåã¯ãåšå²æž©åºŠã10ââŒ35âã®ç¯å²ãè¶ ããªãç¯å²ã«ããŠãã ããã ã©ãã¯ããŠã³ãã§äœ¿çšããå Žåã¯ã©ãã¯ããŠã³ãã®äžã®æž©åºŠããã®ç¯å²ã«ãªããã ã«ææ°ãé颚ãè¡ã£ãŠãã ãããä»ã®è£ 眮ãšã®ééãååã«éããŠé颚ãè¯ãããŠãã ãããæ¬è£œåã®éæ°ã¯ åé¢âèé¢ã§è¡ãããŸããæ¬è£ çœ®ãèšçœ®åŸã«éæ°åããµããããªãããã«ããŠãã ããã空æ°ãæ£ãã埪ç°ã ãããã«ãæ¬è£œåã®é颚å£ããïŒcm以äžã®ã¹ããŒã¹ã空ããŠãã ããã ãŸãå¯éã¿ã€ãã®ã©ãã¯ã䜿çšããå Ž åãé©åãªé颚ãåºæ¥ãªãå ŽåããããŸãã ãã®ãããªå Žåã«ã¯é颚ãè¯ãããçºã«åé¢åã³åŸé¢æãéæŸ ããŠã䜿çšãã ããã ããŒããã£ã¹ã¯ã¯æž©åºŠãé«ãã»ã©æ éçãé«ããªããŸãã 蚱容枩床ç¯å²å ã§åºæ¥ãé ãäœã枩床ã§ã䜿çšãã ããã â ãã³ãª ãã³ãªã®å€ãç°å¢ã«èšçœ®ããå Žåããã³ãªãå éšã«èç©ãããã³ã³ãããŒã©åºæ¿ã®çµ¶çžäžè¯ãé颚æªåã«ããå éšæž©åºŠã®äžæãåã³ãã¯ã¿éšã®æ¥è§Šäžè¯çã«ããæ éãçºçãæããªããŸãã åºæ¥ãéããã³ãªã®å°ãªãå Žæ ã«èšçœ®ããŠãã ããã éèŠ â æ¬è£œå㯠RAID ã¢ãŒããã¯ãã£ã«åºã¥ããRAID5 ã®å ŽåïŒå°ã®ãã©ã€ãã«é害ãçºçããŠãããŒã¿ã®æå€±ãé² ãããèšèšãããŠããŸããããïŒå°ä»¥äžã®ãã©ã€ãã«åæã«é害ãçºçããå Žåããåé·åãããŠããªãéšåã« é害ãçºçããå Žåã¯ããŒã¿ã倱ãããå¯èœæ§ããããŸãããŸããåé·æ§ã®ãªã RAID0 ã®å Žåã¯ãïŒå°ã®ãã© ã€ãã«é害ãçºçããå Žåã§ããããŒã¿ã倱ãããå¯èœæ§ããããŸãã ããããããäºæ¿ãã ããããŸããäººçº çãªããŒã¿ã®æ¶å»ãæ©åšã®æå£ãªã©ã®çç±ã«ããããŒã¿ã倱ãå¯èœæ§ããããŸãã®ã§ãéèŠãªããŒã¿ã¯å¿ ã宿 çã«ããã¯ã»ã¢ããããåããã ããã â ãã¹ãã»ã·ã¹ãã ã皌åäžã«ãæ¬è£œåã®é»æºã鮿ããªãã§ãã ããã æ¬è£œåã®ãã£ãã·ã¥ã»ãããã¡å ã«æ®ã£ãŠ ããããŒã¿ã倱ããããããã¡ã€ã«ãããããå¯èœæ§ããããŸããç·æ¥ã®äºæ 以å€ã¯ããã¹ãã»ã·ã¹ãã ãã·ã£ãã ããŠã³ããŠæ¬è£œåã®ãã£ã¹ã¯ã»ãã©ã€ããžã®ã¢ã¯ã»ã¹ã忢ããŠããæ¬è£œåã®é»æºã鮿ããŠãã ããã â ãã©ã€ãé害ãçºçãããªãã«ãåäœãå®è¡äžã«é»æºã®ãªã³ã»ãªããè¡ããªãã§ãã ããã ãã©ã€ããžã®æžã蟌ã¿äžã«é»æºãèœã¡ãŸããšãã©ã€ãå ã®ããŒã¿ããã©ã€ãèªèº«ãå£ããå ŽåããããŸãã â åé»çã«ãã£ãŠãã©ã€ããžã®æžã蟌ã¿äžã«é»æºãèœã¡ãŸããšãã©ã€ãå ã®ããŒã¿ããã©ã€ãèªèº«ãå£ããå Žåã ãããŸããéçšæã«ã¯ç¡åé»é»æºïŒUPSïŒã®äœ¿çšã匷ããå§ãããŸãã â æ¬è£œåã«ç©ºããã©ã€ããã€ãããå Žåã«ã¯ããšã¢ãŒãããŒã«æªåœ±é¿ããããŸãã ãã©ã€ããå ¥ã£ãŠããªãå Žåã« ãå¿ ããã€ã®å åŽã«è²Œã£ãŠããéæã·ãŒããå¥ãããã«ããã€ãå ¥ããç¶æ ã§ã䜿çšãã ããã 6/57 A12F-G2221 åæ±èª¬ææž ç®æ¬¡ ã¯ããã«................................................................................................................................................................................2 ãæ³šæ ...................................................................................................................................................................................2 å®å šã«ã䜿ããã ãããã« ..................................................................................................................................................3 ç®æ¬¡.......................................................................................................................................................................................7 1. A12F-G2221 ã®æŠèŠ................................................................................................................................................... 10 1.1 補åã®æŠèŠ.......................................................................................................................................................................10 1.2 補åã®ç¹é·.......................................................................................................................................................................10 1.3 æ¬æ©ã®RAIDæ©èœæŠèŠ.....................................................................................................................................................11 2. 補å仿§ ...................................................................................................................................................................... 12 2.1 2.2 2.3 2.4 åºæ¬ä»æ§...........................................................................................................................................................................12 RAID ã³ã³ãããŒã©ä»æ§...................................................................................................................................................12 äžè¬ä»æ§...........................................................................................................................................................................13 ç°å¢æ¡ä»¶...........................................................................................................................................................................13 3. 鿢±ããã³ä»å±åã®ç¢ºèª............................................................................................................................................ 14 4. åéšã®åç§°ãšæ©èœ........................................................................................................................................................ 15 4.1 äž»èŠã³ã³ããŒãã³ãã®åç§°...............................................................................................................................................15 4.2 åé¢ããã«åã³ã³ããŒãã³ãã®æŠèŠ................................................................................................................................16 4.2.1 LCDããã« .............................................................................................................................................................16 4.2.2 HDDãã¬ã€ãšãšã³ã¯ããŒãžã£ãŒãã€ã®äœçœ®.............................................................................................................16 4.2.3 Dongleãããã«ã€ããŠ.............................................................................................................................................17 4.3 èé¢ããã«åã³ã³ããŒãã³ãã®æŠèŠ................................................................................................................................18 4.3.1 ã³ã³ãããŒã©ã¢ãžã¥ãŒã« ...........................................................................................................................................18 4.3.2 ããããªãŒããã¯ã¢ãããŠãããïŒBBUïŒ...................................................................................................................18 4.3.3 黿ºãŠãããïŒPSUïŒ.................................................................................................................................................19 4.3.4 FANãŠããã ............................................................................................................................................................19 5. ã€ã³ã¹ãã¬ãŒã·ã§ã³......................................................................................................................................................... 20 5.1 ã¡ã¢ãªãŒã¢ãžã¥ãŒã«ã®ã€ã³ã¹ãã¬ãŒã·ã§ã³ ..........................................................................................................................20 5.2 BBUïŒããããªãŒããã¯ã¢ãããŠãããïŒã®ã€ã³ã¹ãã¬ãŒã·ã§ã³............................................................................................21 5.3 ã³ã³ãããŒã©ã®ã€ã³ã¹ãã¬ãŒã·ã§ã³.......................................................................................................................................21 5.4 ãã©ã€ãã®ã€ã³ã¹ãã¬ãŒã·ã§ã³ .............................................................................................................................................22 5.4.1 SATAãã©ã€ãã®ã€ã³ã¹ãã¬ãŒã·ã§ã³ .........................................................................................................................22 5.4.2 Parallel ATAãã©ã€ãã®ã€ã³ã¹ãã¬ãŒã·ã§ã³.............................................................................................................22 5.5 ãã©ã€ããã¬ã€ïŒHDDä»ïŒã®ã€ã³ã¹ãã¬ãŒã·ã§ã³ ..................................................................................................................23 6. æ¬æ©ã®ã¢ãã¿ãŒæ©èœ.................................................................................................................................................... 25 6.1 ã¢ãã¿ãŒæ©èœæŠèŠ............................................................................................................................................................25 6.2 LEDã«ããã¢ãã¿ãŒ.........................................................................................................................................................26 6.2.1 ã³ã³ãããŒã©ã¢ãžã¥ãŒã«ã®LEDã¢ãã¿ãŒ ................................................................................................................26 6.2.2 LANããŒãã®LEDã¢ãã¿ãŒ ...................................................................................................................................27 6.2.3 LCDããã«ã®LEDã¢ãã¿ãŒ..................................................................................................................................27 6.2.4 ãã©ã€ããã¬ã€ã®LEDã¢ãã¿ãŒ.................................................................................................................................27 6.2.5 黿ºãŠãããïŒPSUïŒã®LEDã¢ãã¿ãŒ .....................................................................................................................28 7/57 A12F-G2221 åæ±èª¬ææž 6.2.6 FANãŠãããã®LEDã¢ãã¿ãŒ.................................................................................................................................28 6.2.7 BBUã®LEDã¢ãã¿ãŒ .............................................................................................................................................28 6.3 ãã¶ãŒé³ã«ããã¢ãã¿ãŒ..................................................................................................................................................29 6.3.1 ãã¶ãŒé³ã«ããã¢ã©ãŒã ã®ãã©ã¡ãŒã¿äžéãäžéã®ããã©ã«ãå€..........................................................................29 6.3.2 æ éã®å Žåãã¶ãŒé³ã§ã¢ã©ãŒã ãåºãã³ã³ããŒãã³ã.........................................................................................29 6.3.3 I2C ã¢ãã¿ãªã³ã°.....................................................................................................................................................29 6.4 LCDãã£ã¹ãã¬ã€ã«ããã¢ãã¿ãŒ.....................................................................................................................................30 6.5 PCã¿ãŒããã«ã«ããã¢ãã¿ãŒ ..........................................................................................................................................31 7. æ¬æ©ã®æ¥ç¶ãšãªãã¬ãŒã·ã§ã³ ....................................................................................................................................... 32 7.1 FCã€ã³ã¿ãŒãã§ãŒã¹.........................................................................................................................................................32 7.2 æ¬æ©ã®æ¥ç¶äŸ...................................................................................................................................................................32 7.2.1 ãã¡ã€ããŒãã£ãã«ã®æ¥ç¶åœ¢æ ..............................................................................................................................32 7.2.2 ã·ã³ã°ã«ãã¹ãæ¥ç¶äŸ âã¯ã©ã¹ã¿ãŒãã¹ãâ .........................................................................................................33 7.2.3 ã·ã³ã°ã«ãã¹ãæ¥ç¶äŸ âãã€ã¬ã¯ãæ¥ç¶â............................................................................................................33 7.3 黿ºã®æå ¥.......................................................................................................................................................................34 7.3.1 黿ºæå ¥åã«............................................................................................................................................................34 7.3.2 黿ºæå ¥ã®é çª ......................................................................................................................................................34 7.3.3 黿ºæå ¥æã®ç¶æ ãã§ã㯠.....................................................................................................................................35 7.4 黿ºã®åææé ...............................................................................................................................................................36 7.5 RAIDã®æ©èœ ....................................................................................................................................................................37 7.5.1 è«çãã©ã€ãïŒLogical DriveïŒ .................................................................................................................................37 7.5.2 è«çããªã¥ãŒã ïŒLogical VolumeïŒ..........................................................................................................................37 7.5.3 RAID ã¬ãã«..........................................................................................................................................................37 7.5.4 Spare Drives..........................................................................................................................................................40 7.6 RAIDã®åæåäœæ¥.........................................................................................................................................................42 7.6.1 åDrive Statusããã³çŸåšã®Logical Drive Statusã®ç¢ºèª................................................................................42 7.6.2 RAIDã®åæå........................................................................................................................................................43 7.6.3 ãã¹ãã®èšå®.............................................................................................................................................................46 8. 宿çãªã¡ã³ããã³ã¹ .................................................................................................................................................. 47 8.1 Task Scheduleræ©èœ.......................................................................................................................................................47 8.1.1 Task Schedulerã®æŠèŠ..........................................................................................................................................47 8.1.2 Task Scheduleã®æ°èŠäœæ....................................................................................................................................47 8.1.3 Task Scheduleã®è¿œå ïŒåé€................................................................................................................................48 8.1.4 Task Scheduler ã®ãªãã·ã§ã³...............................................................................................................................48 8.1.5 Start Time and Date âéå§æ¥æã®èšå®â.......................................................................................................48 8.1.6 Execution Period âã¡ãã£ã¢ã¹ãã£ã³ãå®è¡ããééâ ...................................................................................49 8.1.7 Media Scan Mode âã¡ãã£ã¢ã¹ãã£ã³ã®ã¢ãŒãèšå®â......................................................................................49 8.1.8 Media Scan Priority âã¡ãã£ã¢ã¹ãã£ã³ã®ãã©ã€ãªãªãã£ã®èšå®â ..................................................................49 8.1.9 Select Logical Drives âã¡ãã£ã¢ã¹ãã£ã³ãè¡ãè«çãã©ã€ãã®éžæâ.............................................................50 8.1.10 Confirming the Creation of a Task Schedule âèšå®ã®ç¢ºèªâ...................................................................50 9. ä¿å®.............................................................................................................................................................................. 51 9.1 é害ã®ç¢ºèª.......................................................................................................................................................................51 9.2 黿ºãŠãããïŒPSUïŒã®ä¿å®..............................................................................................................................................51 9.2.1 PSUä¿å®ã®æ³šæäºé ..............................................................................................................................................51 9.2.2 PSUã®äº€æ .............................................................................................................................................................51 9.3 BBUã®ä¿å®......................................................................................................................................................................52 9.3.1 BBUä¿å®ã®æ³šæäºé .............................................................................................................................................52 9.3.2 BBUã®äº€æ.............................................................................................................................................................52 9.4 FANãŠãããã®ä¿å®..........................................................................................................................................................53 9.4.1 FANãŠãããä¿å®ã®æ³šæäºé .................................................................................................................................53 8/57 A12F-G2221 åæ±èª¬ææž 9.4.2 FANãŠãããã®äº€æ.................................................................................................................................................53 9.5 HDDãšHDDãã¬ã€ã®ä¿å®................................................................................................................................................54 9.5.1 HDDã®ç¶æ³ç¢ºèª.....................................................................................................................................................54 9.5.2 HDDã®äº€æäœæ¥...................................................................................................................................................55 9.4.3 HDD亀æåŸã®ãã§ãã¯..........................................................................................................................................56 9/57 A12F-G2221 åæ±èª¬ææž 1. A12F-G2221 ã®æŠèŠ 1.1 補åã®æŠèŠ A12F-G2221 ã¯ãµãŒãã®ã¡ã€ã³ã¹ãã¬ãŒãžçšãšããŠéçºããã2GFC SAN æ¥ç¶å¯èœãªã€ã³ã¿ãŒãã§ãŒã¹ãæã¡ãSã» ATA I/F HDD16 å°ãæèŒã§ãããïŒU ã©ãã¯ããŠã³ãã¿ã€ãã®è¶ 髿§èœããŒããŠãšã¢ RAID ãµãã·ã¹ãã ã§ãã RAID ã¬ãã«ã¯ RAID 0, 1ïŒ0+1ïŒ, 3, 5, 10, 30, 50, J-BOD ã«å¯Ÿå¿, RAID1 以äžã®èšå®ã§ã¯ïŒå°ã®ããŒããã£ã¹ã¯ã« é害ãçºçããå Žåãã·ã¹ãã 皌åç¶æ ã§ã®åé¢ããã®ç°¡åãªæäœã§ããã©ã€ãã®äº€æãšãªãŒããªãã«ããå¯èœã§ãã 1.2 補åã®ç¹é· è¶ é«éãã¹ãã€ã³ã¿ãŒãã§ãŒã¹ ãã¹ãæ¥ç¶ã€ã³ã¿ãŒãã§ãŒã¹ 2G FC x 2ch ã«ãããè¶ é«éããŒã¿è»¢éãå¯èœã§ãã ãŸããã¥ã¢ã«ãã¹ãæ¥ç¶ã«ãã HA ã¯ã©ã¹ã¿ãµãŒãæ§æãå¯èœã«ããŸãã ææ°ã® RAID ãã¯ãããžãŒ 266MHz ããŒããŠãšã¢ XOR ãå§ããšããŠãå šãŠ 64bit ã¢ãŒããã¯ãã£ã§æ§æãããªã¢ã«ã¿ã€ã ããã»ã¹ãšé«åºŠãªãã£ã ã·ã¥ã¢ã«ãŽãªãºã ãæ¡çšããŠããŸãã ãŸãè€åRAID ã¢ãŒããåçš®ã®é«åºŠãª RAID ãããŒãžã¡ã³ãã«è³ããŸã§å¹ åºãæ æ°ã®æè¡ãé§äœ¿ããŠããŸãã 倧容é SATA (ã·ãªã¢ã« ATA) HDD 3U æšæºã©ãã¯ãµã€ãºã« HDD 16 å°æèŒå¯èœã 250GB HDD/ RAID 0 ã§ 3 ãã©ãã€ãã®èšæ¶å®¹éã ã³ã¹ãããã©ãŒãã³ã¹ ãããã¬ã³ãžã¯ã©ã¹ã® RAID ã¹ãã¬ãŒãžãšããŠã¯æ¥çã§åããŠåŸæ¥ã®ãšã³ããªãŒã¯ã©ã¹ã®äŸ¡æ Œãå®çŸããŸããã åçš®ãŠãããã®ã¢ãžã¥ãŒã«åãå ±éåã«ããå€§å¹ ãªã³ã¹ãããŠã³ãå³ã£ãŠããŸãã é«åºŠãªãã©ã«ããã¬ã©ã³ã¹ ã·ã¹ãã å šäœã®é«åºŠãªãã©ã«ããã¬ã©ã³ã¹ãå®çŸããããã«ãHDDãå§ããšããŠã黿ºããã¡ã³çã«ãããŠãåé·åãã ããã¹ã¯ããæ§é ãæ¡çšã é«ãã¡ã³ããã³ã¹æ§ é«åºŠãªã¡ã³ããã³ã¹æ§ãå®çŸããããã«ãäž»èŠãŠãããã¯å šãŠã¢ãžã¥ãŒã«åããããã¹ã¯ããæ§é ãæ¡çšããŠããŸãã ãŸãäºåã¡ã³ããã³ã¹ãå¯èœã«ããããåçš®ã®ã¢ã©ãŒã ãã¡ãã»ãŒãžã³ã°ãã³ã³ãããŒã«çã¯ããŒã«ã« LCD åã¯ãã€ã³ ãã³ããã¢ãŠããã³ãã§ã®ã¢ãã¿ãŒç»é¢ããå®è¡ããããšãã§ããŸãã äœéšé³ ãã€ãºã®å°ãªã Dual Speed FAN ãäœ¿çš 10/57 A12F-G2221 åæ±èª¬ææž 1.3 æ¬æ©ã® RAID æ©èœæŠèŠ ãã®ç« ã§ã¯æ¬æ©ã® RAID æ©èœã®æŠèŠãèšè¿°ããŠããŸãã è©³çŽ°ã¯æ·»ä» CD-ROM ã® Generic Manual ïŒGMN.x.xx.pdfïŒ è±æïŒ âChapterïŒâ ãåç §é¡ããŸãã æ¬è£ 眮㯠RAID0ãRAID1(0+1)ãRAID3(30)ãRAID5(50)ãNRAIDãJBOD ããµããŒãããŠãããRAID0 ã¯ããã¹ãŠã® è£ çãã©ã€ãã 1 å°ã®ãã©ã€ããšããŠæ±ããRAID1 ã¯ã1 å°ã®ãã©ã€ãã®è€è£œãè¡ããRAID0+1 ã¯ãRAID0 ãš RAID1 ãçµã¿åããããã®ã§ RAID0 ã§æ§æããããã©ã€ãã®è€è£œãè¡ããRAID3ãRAID5 ã¯ãè£ çãã©ã€ãã®ãã¡ 1 å°åã ããªãã£ãšããŠäœ¿çšãã1 å°ã®ãã©ã€ããæ éããŠããŠãŒã¶ãŒããŒã¿ãç¶æããããšãã§ããã¢ãŒãã§ããã¹ãã¢ãã©ã€ ããæå®ãããšãæ éãããã©ã€ããã¡ã³ããŒããå€ããã¹ãã¢ãã©ã€ãã代æ¿ãã©ã€ããšã㊠RAID3ã5 ãåæ§ç¯ïŒãªã ã«ãïŒããŸãã ã¹ãã¢ãã©ã€ãã¯ãæ éããŒããã£ã¹ã¯ã®ä»£æ¿ãã©ã€ãã§ãããïŒ å°ã®ãã©ã€ããæ éããå Žåãèªåã§æ éãã©ã€ãã® ããŒã¿ã代æ¿ãã©ã€ãã«åŸ©æ§ããŸããïŒåŸ©æ§äœæ¥ã¯ããã¯ã°ã©ãŠã³ãã§è¡ãããããããã¹ãã³ã³ãã¥ãŒã¿ã忢ããå¿ èŠããããŸãããäœããã®äœæ¥ã¯ãæ°æéâŒåæ°æéãèŠããŸããïŒ äœæ¥çµäºåŸã¯ RAID3 ã5 ã®ç¶æ ã«åŸ©æ§ã㟠ãã äœã RAID3 ã5 ã¯ãå®å šã«æ éããªãã·ã¹ãã ã§ã¯ãããŸãããRAID ãæ§æããŠãã 2 å°ä»¥äžã®ããŒããã£ã¹ã¯ã æ éããå Žåã¯ãå šãŠã®ããŒã¿ã倱ãããŸãã®ã§ãããŒã¿ãããå®å šã«ä¿ç®¡ããããã«ã¯ãããã¯ã¢ããè£ çœ®ãžã® ã宿çãªããã¯ã¢ããã ãå¿ èŠã§ãã RAID ã¢ãŒã RAID0 RAID1(0+1) RAID3 RAID5 ãã©ã€ãæ°ïŒã¹ãã¢ãã©ã€ãã¯é€ãïŒ N N N N æ¬è£œåã¯ãæå€§ïŒ6 å°ã® SATA ã¿ã€ãã®ãã©ã€ããå èµããããšãã§ããŸãã 11/57 ïŒçŽïŒç·å®¹é N N/2 N-1 N-1 A12F-G2221 åæ±èª¬ææž 2. 補å仿§ 2.1 åºæ¬ä»æ§ æ©çš®å ãã¹ãæ¥ç¶ã€ã³ã¿ãŒãã§ãŒã¹ ãã¹ãæå€§è»¢éã¹ããŒã ãã¹ãæ¥ç¶ã¢ãŒã èšæ¶å®¹é RAID 0 ïŒ250GB HDD ã RAID 1 ãã«æèŒã®å ŽåïŒ RAID 5 RAID5+Spare ãã£ãã·ã¥å®¹é æèŒ HDD æ§æ RAID æ©èœ æèŒé»æº A12F-G2221 2G FC x 2ch 400MB/s ïŒ2G FC x 2chïŒ ãã«ããã¹ãæ¥ç¶ïŒSAN æ¥ç¶ 3,000GB 1,500GB 2,750GB 2,500GB æå€§ 1GB 3.5â S-ATA HDD x 12 ãããã¹ã¯ããïŒãããã¹ãã¢ïŒãªãŒããªãã«ãïŒãªã³ã©ã€ã³ RAID æ¡åŒµ ãããã¹ã¯ãã 350W äºéå黿º 2.2 RAID ã³ã³ãããŒã©ä»æ§ æ©çš®å æ§é ãã¹ã OS ã³ã³ããã£ããªã㣠ãã¹ãã€ã³ã¿ãŒãã§ãŒã¹ HDD ã€ã³ã¿ãŒãã§ãŒã¹ RAID ããã»ããµ RAID ã¢ãŒããã¯ãã£ãŒ RAID ã¬ãã« æå€§ LUN æ° ãã£ãã·ã¥ã¡ã¢ãª BBUïŒããããªãŒããã¯ã¢ããïŒ ã¢ãã¿ãªã³ã° ãããŒãžã¡ã³ã&ã³ã³ãããŒã« A12F-G2221 FC to S-ATA ããŒããŠã§ã¢ RAID O/S Independent 2G FC x 2ch 3.0Gbps S-ATA x 12 600MHz Power PC750FX 266Mhz ããŒããŠãšã¢ XOR ãšã³ãžã³ ãã¥ã¢ã« PCI-Xbus 64bit, 133MHz 0, 1, (0+1), 3, 5, 10, 30, 50, J-BOD, Non-RAID 32ïŒ1Host ID æšæº 256MBïŒæå€§ 1GBïŒ DDR DIMM å¥å£²ãªãã·ã§ã³ LEDãããŒããLCDïŒHDD,ã³ã³ãããŒã©,黿º,FAN,æž©åºŠïŒ â LCD ã³ã³ãœãŒã«ïŒããã³ãããã«ã«è£ åïŒ â¡ VT ã¿ãŒããã« SNMP å¯Ÿå¿ Web GUIRAID ãããŒãžã£ãŒ 12/57 A12F-G2221 åæ±èª¬ææž 2.3 äžè¬ä»æ§ æ©çš®å A12F-G2221 FCC Class-BãCEãUL AC100âŒ250V ãªãŒã 50/60 Hz é©å¿èŠæ Œ æèŠé»æº æ¶è²»é»å ãšãã«ã®ãŒæ¶è²»å¹çïŒRAID5ïŒ çºç±é å¯žæ³ æ¬äœéé ãã¹ãã€ã³ã¿ãŒãã§ãŒã¹ã³ãã¯ã¿ ãã®ä»ã® I/F ã³ãã¯ã¿ ãããã¹ã¯ãããŠããã ä»å±å 黿ºã±ãŒãã« ã·ãªã¢ã«ã±ãŒãã« NULL ã¢ãã ã³ãã¯ã¿ ããã¥ã¢ã« 350W 0.127W/GB (250GB HDD16 å°äœ¿çšæ) 1,260KJïŒhour, 300KcalïŒhour 88.0mm(H) x 446.0mm(W) x 490.0mm(D) ïŒããã³ããã³ãã«å«ãŸãïŒ 88.0mm(H) x 482.0mm(W) x 505.0mm(D) ïŒããã³ããã³ãã«å«ãïŒ 33KgïŒHDD å«ãïŒã25KgïŒHDD å«ãŸãïŒ 2G FC çš SFP ïœ 2 RS-232C Audio Jack x 1 Ethernet 10/100Mbps RJ45 ïœ ïŒ HDD ãã¬ã€ 黿ºãŠããã ããããªãŒããã¯ã¢ãããŠããã FAN ãŠããã AC ã±ãŒãã« x 2 RS-232C (Audio Jack) ã±ãŒãã« x 1 NULL ã¢ãã ã³ãã¯ã¿ x 1 CDROM ããã¥ã¢ã« x 2 2.4 ç°å¢æ¡ä»¶ æ©çš®å 枩床ç¯å² 湿床ç¯å² æ¯å è¡æ é«åºŠ åäœæ éåäœæ åäœæ éåäœæ åäœæ éåäœæ åäœæ éåäœæ åäœæ éåäœæ A12F-G2221 ïŒ10âŒïŒ35â -10âŒïŒ50â 10âŒ80%ïŒãã ãçµé²ç¡ãäºïŒ 5âŒ95%ïŒãã ãçµé²ç¡ãäºïŒ 0.5G 5âŒ500Hz X/Y/Z 1.5G 5âŒ500Hz X/Y/Z 10G ïœïœ ïœïœïŒ11ïœïœ duration 100GïŒ180in/sec 240G, 2ms Half-sine 12,000ïœïœ 20,000ïœïœ 13/57 A12F-G2221 åæ±èª¬ææž 3. 鿢±ããã³ä»å±åã®ç¢ºèª 補åãåãåããŸãããæ¢±å ãéããä»å±åã®ç¢ºèªãè¡ã£ãŠãã ããã æ§æéšå æ¬äœ HDD ãã¬ã€ ïŒ¡ïŒ£é»æºã±ãŒãã« RS-232C ( Audio Jack ) ã·ãªã¢ã«ããŒãã±ãŒãã« NULL Modem ã³ãã¯ã¿ CDïŒRAIDWatch / HWmanual etcïŒ CDïŒåæ±èª¬ææžïŒ ããžïŒM6ïŒïŒã©ãã¯ããŠã³ãçšïŒ ããžïŒM5ïŒïŒã©ãã¯ããŠã³ãçšïŒ ããžïŒ#10-32ïŒïŒã©ãã¯ããŠã³ãçšïŒ ä¿èšŒæž ä¿å®ç»é²çšçŽ ïŒãªã³ãµã€ãä¿å®ä»ãã®å Žåã®ã¿ïŒ ãªã³ãµã€ãä¿å®ãµãŒãã¹å¥çŽçŽæ¬Ÿ ïŒãªã³ãµã€ãä¿å®ä»ãã®å Žåã®ã¿ïŒ 14 FC ã±ãŒãã« 15 SFP ã¢ãžã¥ãŒã« 1 2 3 4 5 6 7 8 9 10 11 12 13 æ©çš®å A12F-G2221 1å° 12 å 2æ¬ 1æ¬ 1å 1æ 1æ 4æ¬ 4æ¬ 4æ¬ 1æ 1æ 1æ 1æ¬ å¥å£²ãªãã·ã§ã³ âæ¬è£œåã¯ç²Ÿå¯é»åæ©åšã§ããæ¢±å ç®±ã¯ä¿ç®¡ããŠããã茞éæã«ã¯å¿ ãè³Œå ¥æã®æ¢±å æã»ç®±ãã䜿çšãã ããã 14/57 A12F-G2221 åæ±èª¬ææž 4. åéšã®åç§°ãšæ©èœ 4.1 äž»èŠã³ã³ããŒãã³ãã®åç§° ã»A12F-G2221 (ããã³ãããã«) ã»A12F-G2221ïŒãªã¢ããã«ïŒ ã»ã·ã¹ãã æŠèŠ 15/57 A12F-G2221 åæ±èª¬ææž 4.2 åé¢ããã«åã³ã³ããŒãã³ãã®æŠèŠ 4.2.1 LCD ããã« LCD ããã«ã¯ 16 x 2 æåã® LCDã5 åã®ããã·ã¥ããŒã3 åã® LED ããæ§æãããŸãã LCDããã«ã®æäœã«ããå šãŠã®RAIDæäœãšã¢ãã¿ãŒãã§ããŸãã 黿ºãå ¥ãããšåæç»é¢ã«ã¢ãã«åã衚瀺ãã ãŸãã å€ãã® RAID ã䜿çšããå Žåç°ãªãã¢ãã«åãèšå®ããŠããããšã§ç°¡åã«èå¥ãå¯èœã§ãã å·ŠåŽåã³å³åŽã®ãã©ã€ããã€ã®åºãå ¥ããããå Žåäžå³ã®ããã« OPEN ã©ããã«ããéãå·Šå³ã®ããã«éããŸãã 4.2.2 HDD ãã¬ã€ãšãšã³ã¯ããŒãžã£ãŒãã€ã®äœçœ® ãã©ã€ããã¬ã€ã¯ SATA 3.5 HDD çšãšããŠèšèšãã 2 å ã® LED ã§ãã©ã€ãã®ç¶æ ã衚瀺ããŸãã ãŸãã¯ãªããã ã¿ã³ã§å¹ççã«ãããã¹ã¯ããã«ãã HDD 亀æãå¯èœã§ ãã ãã©ã€ããã€ïŒã¹ãããïŒã¯ 1âŒ12 ãŸã§å³ã®ããã«å·Šããå³ãäžããäžã«çªå·ãå²åœãŠãŸãã I 16/57 A12F-G2221 åæ±èª¬ææž 4.2.3 Dongle ãããã«ã€ã㊠æ¬ã·ãªãŒãºã¯SATAãã©ã€ãçšãšããŠèšèšãããŠããŸããParallel ATAãã©ã€ãã䜿çšããå Žåã¯ãå¥å£²ãªãã·ã§ã³å ãšã㊠SATA-to-PATA 倿çšã® Dongle ãçšæããŠããŸãã 17/57 A12F-G2221 åæ±èª¬ææž 4.3 èé¢ããã«åã³ã³ããŒãã³ãã®æŠèŠ 4.3.1 ã³ã³ãããŒã©ã¢ãžã¥ãŒã« ãµãã·ã¹ãã ã®èé¢äžå€®äžéšã«ãæ¬è£ 眮ã®å¿èéšã®ã³ã³ãããŒã©ã¢ãžã¥ãŒã«ãå ¥ã£ãŠããŸãã ã³ã³ãããŒã©ã¢ãžã¥ ãŒã«ã¯ã¡ã€ã³åè·¯ããŒããBBUïŒå¥å£²ãªãã·ã§ã³ïŒãã¡ã¢ãªãŒããæ§æãããŠããŸãã ã³ã³ãããŒã©ããã«ã®è¡šç€ºãšå€éšã€ã³ã¿ãŒãã§ãŒã¹ SFP ã³ãã¯ã¿ ïŒ ãã¹ãæ¥ç¶ïŒFCïŒçš 2 ãã£ã³ãã« RS-232C (Audio Jack) ã·ãªã¢ã«ããŒãïŒ COM1ïŒã·ã¹ãã ã®ç®¡ççš Ethernet ããŒãïŒRJ-45ïŒïŒ ã·ã¹ãã ã®ãããã¯ãŒã¯çµç±ã§ã® ãªã¢ãŒã管ççš RJ-45 ã€ãŒãµãŒãããããŒã 4.3.2 ããããªãŒããã¯ã¢ãããŠãããïŒBBUïŒ BBU ã¯å¥å£²ããªãã·ã§ã³ã§ãã æ³çèŠå¶ã«ãããBBU ãŠãããã¯åºè·æã«ãã®å®¹éã® 35%âŒ45ïŒ ããå é»ããŠããŸãããåŸã£ãŠé»æº ON åŸãã ã«å é»ãŸã§ã«ããã 12 æéããããŸãã BBU ã¯ã黿ºã® FAIL æã«æå€§ 72 æéãã£ãã·ã¥ã¡ã¢ãªãä¿æããŸããããŒã¿ä¿è·ã®ããã« BBU ã䜿çšããäº ãåŒ·ãæšå¥šããŸãã 18/57 A12F-G2221 åæ±èª¬ææž 4.3.3 黿ºãŠãããïŒPSUïŒ æ¬è£ 眮㯠2 åã®ãããã¹ã¯ããå¯èœãªïŒïŒïŒïŒ·åé·å黿ºãæèŒããŠããŸãã å黿ºãŠãããã¯ïŒåã®ïŒ¡AC ã€ã³ã¬ãããšïŒåã®é»æºã¹ã€ãããæã¡ã黿ºã¹ã€ããã¯ãã®å黿ºãŠãããã®é»æº ONïŒOFF ãã§ããŸãã å黿ºãŠãããã«ã¯ 2 åã®é»æºå·åŽçš FAN ãå èµããŠããŸããå黿ºãŠãããã®ç¶æ 㯠Status LED ã§ç¢ºèªã§ã㟠ãã PSU ã«é害ãèµ·ããå Žåã¯ããªã³ã©ã€ã³ç¶æ ã§ãRetension Screw ãããããŠæåã«åŒãæãäºãã§ããŸãã 亀æ åŸã¯ Retension Screw ãç· ããŸãã 4.3.4 FAN ãŠããã æ¬è£ 眮㯠3 åã®ãããã¹ã¯ããå¯èœãªã¯ãŒãªã³ã° FAN ãŠããããæèŒããŠããŸãã FAN 㯠12cm ããã¯åã䜿çšãåé¢ ããèé¢ãžã®ãšã¢ãŒãããŒã«ããããã©ã€ãã®å·åŽãè¡ããŸãã 19/57 A12F-G2221 åæ±èª¬ææž 5. ã€ã³ã¹ãã¬ãŒã·ã§ã³ 5.1 ã¡ã¢ãªãŒã¢ãžã¥ãŒã«ã®ã€ã³ã¹ãã¬ãŒã·ã§ã³ ES ã·ãªãŒãºã¯ PC-133 SDRAM DIMM ã¡ã¢ãªãŒã¢ãžã¥ãŒã«ãã³ã³ãããŒã©ã®ã¡ã€ã³ããŒãã«ããªã€ã³ã¹ããŒã«ãã㊠ããŸãã ã¡ã¢ãªãŒãã¢ããã°ã¬ãŒãããå Žåã¯ããã§ã«ã€ã³ã¹ããŒã«ãããŠããã¡ã¢ãªãŒãã¯ãããŠäº€æããŸãã ã¡ã¢ ãªãŒã¢ãžã¥ãŒã«ã¯å¿ ãïœïœïœïœïœïœ ïœïœç€Ÿã®æå®åã䜿çšããŠãã ããïŒã·ã¹ãã ãã³ããŒã«åãåãããã ããïŒã 泚æ ã¡ã¢ãªãŒã¢ãžã¥ãŒã«ã¯é黿°çã«å¯ŸããŠéåžžã«ã»ã³ã·ãã£ããªéšåããæ§æãããŸãã 軜çãªåæ±ãã¯ã·ã¹ãã ã®é倧ãªé害ãèµ·ããäºããããŸãã BBU ããã§ã«ã€ã³ã¹ããŒã«ããŠããå Žå㯠ã¡ã¢ãªãŒã亀æããåã«å¿ ã BBU ã®ã³ãã¯ã¿ãã¯ãããŠããè¡ããŸãã BBU ãæ¥ç¶ãããŸãŸã¡ã¢ãªãŒã亀æ ãããšã¡ã¢ãªãŒãå£ããå ŽåããããŸãã Step1 å³ã®ããã«ã³ã³ãããŒã©ã®åºå®ããžïŒç®æããã ããã³ã³ãããŒã©ãŠãããããšãã¯ãããŸãã Step2 å³ã®ããã« 2 ç®æã®ã©ãããç¢å°æ¹åã«æŒããŠã ã€ã³ã¹ããŒã«æžã¿ã®ã¡ã¢ãªãŒã DIMM ãœã±ããã ãåãã¯ãããŸãã Step3 æ°ããã¡ã¢ãªãŒãDIMMãœã±ããã«ç¢ºå®ã«åãä»ããŸãã ãã®ãšãã¡ã¢ãªãŒã®éã¡ãã端åéšã«ã¯æããµããªãã§ã ã ããã ãŸãæ¥è§Šã確å®ã«ãããããã¡ã¢ãªãŒã®è±çãæ°åè¡ã£ãŠãã ããã Step4 BBU ãã€ã³ã¹ããŒã«ããªãå Žåã¯ã³ã³ãããŒã©ãæ¬äœã«åãä»ããŸãã ã³ã³ãããŒã©ã®ã€ã³ã¹ãã¬ãŒã·ã§ã³ ã®é ç®ãåç §ããŠãã ããã BBU ãã€ã³ã¹ããŒã«ããå Žåã¯æ¬¡é ã® BBU ã®ã€ã³ã¹ãã¬ãŒã·ã§ã³ ã®é ç®ã«é²ã¿ãŸ ãã 20/57 A12F-G2221 åæ±èª¬ææž 5.2 BBUïŒããããªãŒããã¯ã¢ãããŠãããïŒã®ã€ã³ã¹ãã¬ãŒã·ã§ã³ ïŒæ³šïŒ ã¯ãªãã·ã§ã³åãšããŠçšæããŠããŸãã BBU ãã€ã³ã¹ããŒã«ãããšãã£ãã·ã¥ããããŒã¿ãåé»æã«æå€§ 72 æéä¿æã§ããŸãã Step1 ãããŒã«ããŒã®ããžãå³ã®ã ãã«ã¯ãããŸãã Step2 ãããŒã«ããŒãåŒãåºããŸãã Step3 ãå³ã®ããã«å·®èŸŒã¿ãŸ ãã Step2 ã€ãŸã¿ããžãïŒã¶æçããŸãã 5.3 ã³ã³ãããŒã©ã®ã€ã³ã¹ãã¬ãŒã·ã§ã³ StepïŒ ã³ã³ãããŒã©ãæ¬äœã®ãã€ã«æ éã«æ¿å ¥ã ãŸãã æ£ããæ¿å ¥ãããšãã³ã³ãããŒã©ã®ããã«é¢ ããã®äžã®ãã©ã³ã¯ãã¬ãŒãé¢ãšåãäœçœ® ã«ãªããŸãã Step2 2 ç®æã®åºå®ããžãæã§ç· ãä»ããŸãã 21/57 A12F-G2221 åæ±èª¬ææž 5.4 ãã©ã€ãã®ã€ã³ã¹ãã¬ãŒã·ã§ã³ 泚æ ã» ã» ã» ã» HDD ã¯è¡æããã³é黿°ã«å¯ŸããŠéåžžã«ããªã±ãŒãã§ãã ã·ã§ãã¯ãäžããªãããååæ³šæããHDD ã« è§Šããåã«äœããã®æ¹æ³ã§äººäœã®é黿°ãæŸé»ããŠãã ããã HDD ã«ç Žæããã£ãå ŽåïŒã³ãã¯ã¿ã®æ¬ ããã©ãã«ã¯ããçïŒã¯ã亀æã«å¿ããããªãå ŽåããããŸãã æ éã«ãåãæ±ããã ããã ã12å°æªæºã§äœ¿çšããå Žåããå¿ ã空ãã¬ã€ãè£ çããŠãã ããã ãã¬ã€ãè£ çããŠããªããã€ãã ããšé©åãªãšã¢ãŒãããŒãåŸããããå éšã®çºç±ã«ããé倧ãªé害ãèµ·ããæãããããŸãã æ¬æ©ãã©ãã¯ã«åºå®ããå Žåã¯ãïŒšïŒ€ïŒ€ãæ¬äœã«æ¿å ¥ããåã«è¡ã£ãŠãã ããã ã¯éãããããã©ã ã¯åºå®æã«ãå±éºã§ãã 5.4.1 SATA ãã©ã€ãã®ã€ã³ã¹ãã¬ãŒã·ã§ã³ Step1 å³ã®ããã« HDD ããã¬ã€ã«ãããŸãã Step2 ïŒã¶æãã€ã³ãããžã§åºå®ããŸãã ä»å±ã®ããžä»¥å€ã¯äœ¿çšããªãã§ãã ããã é·ãããžã䜿çšãããš HDD ã®åè·¯ã«é害ã äžããå ŽåããããŸãã å·¥å Žåºè·æã«ã¯ããã©ã€ããã¬ã€ïŒHDD ä»ãïŒãæ¬äœãã£ããããã«æ¿å ¥ããã«ã奿¢±å ã«ãªã£ãŠããå ŽåããããŸãã äžèšã®æ³šæé ç®ãããèªã¿ãå åæ³šæããŠãæ éã«ãã©ã€ããã¬ã€ãã€ã³ã¹ããŒã«ããŠãã ããã 5.4.2 Parallel ATA ãã©ã€ãã®ã€ã³ã¹ãã¬ãŒã·ã§ã³ PATA ãã©ã€ãã䜿çšããå Žåã«ã¯ãå¥å£²ããªãã·ã§ã³ã® Dongle Kit ãå¿ èŠã§ãã Step1 PATA to PATA ã® Dongle Kit ãåãä»ããŠã ãå Žåã¯ãåãå€ããŸãã ããžãšãäœçœ®ã¯å³ã®äœçœ®ã§ãã 22/57 A12F-G2221 åæ±èª¬ææž Step2 PATA to PATA ã® Dongle Kit ã ïŒã¶æããžçãããŠãã ããã Step3 HDD ã«é»æºã³ãã¯ã¿ãšãã±ãŒãã«ã æ¥ç¶ããŸãã Step4 å³ã®ããã«ïŒã¶æãã€ã³ãããžã§åºå®ããŸãã ä»å±ã®ããžä»¥å€ã¯äœ¿çšããªãã§ãã ããã é·ãããžã䜿çšãããš HDD ã®åè·¯ã«é害ã äžããå ŽåããããŸãã 5.5 ãã©ã€ããã¬ã€ïŒHDD ä»ïŒã®ã€ã³ã¹ãã¬ãŒã·ã§ã³ å·¥å Žåºè·æã«ã¯ããã©ã€ããã¬ã€ïŒHDD ä»ïŒãæ¬äœãã£ããããã«æ¿å ¥ããã«ã奿¢±å ã«ãªã£ãŠããå ŽåããããŸãã äžèšé ç®ã«æ³šæããŠãæ éã«ãã©ã€ããã¬ã€ãã€ã³ã¹ããŒã«ããŠãã ããã æ³šæ ã» ã» ã» ã» ã» HDD ã¯è¡æããã³é黿°ã«å¯ŸããŠéåžžã«ããªã±ãŒãã§ãã ã·ã§ãã¯ãäžããªãããååæ³šæããHDD ã«è§Š ããåã«äœããã®æ¹æ³ã§äººäœã®é黿°ãæŸé»ããŠãã ããã HDD ã«ç Žæããã£ãå ŽåïŒã³ãã¯ã¿ã®æ¬ ããã©ãã«ã¯ããçïŒã¯ã亀æã«å¿ããããªãå ŽåããããŸãã æ éã«ãåãæ±ããã ããã ãã¬ã€ã«è£ çããŠãã HDD ã¯å·¥å Žã«ãŠãšãŒãžã³ã°ãã¹ããããŠåºè·ããŠãããŸãã ã€ã³ã¹ããŒã«æã«èœäžã ããããŸãä»ã®ãã£ã¹ã¯ã䜿çšãããããªãããã«ãé¡ãããŸãã HDD ã 12 å°æªæºã§äœ¿çšããå Žåããå¿ ã空ãã¬ã€ãè£ çããŠãã ããã ãã¬ã€ãè£ çããŠããªããã€ããã ãšé©åãªãšã¢ãŒãããŒãåŸããããå éšã®çºç±ã«ããé倧ãªé害ãèµ·ããæãããããŸãã æ¬æ©ãã©ãã¯ã«åºå®ããå Žåã¯ãHDD ãæ¬äœã«æ¿å ¥ããåã«è¡ã£ãŠãã ããã HDD ã¯éããããã©ãã¯åº 宿ã«ãå±éºã§ãã StepïŒ ããŒããã¯ãã¢ã³ããã¯ã®ç¶æ ã§ããããšã確èªããŸãã 23/57 A12F-G2221 åæ±èª¬ææž å³ã®ããã«ãã¬ã€äžå€®ã®ã¯ãªãããæŒãäžããã©ãããéããŸãã StepïŒ HDD ä»ããã¬ã€ããã£ããçäœã«æ¿å ¥ãæ¢ãŸããŸã§æŒããŸãã ãã¬ã€ã®ãã©ãããããã¯ããŸãã HDD ã«è²Œã£ãŠããçªå·è¡šç€ºãšãã©ã€ããã€ïŒïŒ³ïœïœïœçªå·ïŒãééããªãããã«æ¿å ¥ããŠãã ããã ãã©ã€ããã€ïŒSlot çªå·ïŒã¯ 1âŒ16 ãŸã§äžå³ã®ããã«é 眮ãããŠããŸãã I Step3 ããŒããã¯ãå³ã®ããã«ããã¯ããŸãã 24/57 A12F-G2221 åæ±èª¬ææž 6. æ¬æ©ã®ã¢ãã¿ãŒæ©èœ 6.1 ã¢ãã¿ãŒæ©èœæŠèŠ æ¬ RAID ãµãã·ã¹ãã ã«ã¯ã·ã¹ãã ç¶æ ãç£èŠããé害ãèµ·ããæã«ãã¢ã©ãŒããåºããé©åãªã¢ã¯ã·ã§ã³ããšãããã ã«ã次ã®ããã«å€ãã®ã¢ãã¿ãŒæ©èœãè£ åããŠããŸãã â LED ã«ããã¢ãã¿ãŒ æ¬æ©ã®å šãŠã®ã¢ã¯ãã£ããªã³ã³ããŒãã³ãã« LED ãè£ åãããåäœç¶æ ã衚瀺ããŠããŸãã â ãã¶ãŒé³ã«ããã¢ãã¿ãŒ ã³ã³ãããŒã©ããŒãäžã«ãã¶ãŒãè£ åãããåã³ã³ããŒãã³ãã®é害æã«é³ã§ç¥ãããŸãã é害å 容ã®ç¹å®ã¯ãLCD 衚瀺ãRS-232C ãŸã㯠LAN æ¥ç¶ãã PC ã®ã¿ãŒããã«è¡šç€ºçã§è¡ããŸãã â LCD ãã£ã¹ãã¬ã€ã«ããã¢ãã¿ãŒ æ¬æ©ã® RAID ã³ã³ãããŒã©ã«ã¯ç®¡çãã¡ãŒã ãŠãšã¢ïŒïŒŠ/ïŒãå«ãŸããŠãããåé¢ã® LCD ããã«ã®æäœã«ããã·ã¹ ãã ç¶æ ã®å šãŠã®ã¢ãã¿ãŒããã³ã³ã³ãããŒã«ãã§ããŸãã æ¬ããã¥ã¢ã«ã§ã¯åºæ¬ç㪠LCD ããã«ã®æäœã« é¢ããŠèšè¿°ããŠããŸãã è©³çŽ°ã¯æ·»ä» CD-ROM ã® Generic ManualïŒGMN.x.xx.pdfïŒ è±æïŒãåç §é¡ããŸãã â PC ã¿ãŒããã«ã«ããã¢ãã¿ãŒ 管ççšPC ãšæ¬æ©ãªã¢ããã«ã® RS-232CïŒAudio JackïŒãä»å±ã®ã±ãŒãã«ã§æ¥ç¶ããWindows æšæºã® Hyper Terminal çã®éä¿¡ãœããã䜿çšããŠãã·ã¹ãã ç¶æ ã®å šãŠã®ã¢ãã¿ãŒããã³ã³ã³ãããŒã«ãã§ããŸãã ã¢ã ã¿ãŒããã³ã³ã³ãããŒã«ã§ããå 容㯠LCD ããã«ã«ããæ¹æ³ãšãã»ãŒåãã§ãã ãŸãæ¬æ©ãªã¢ããã«ã«ã¯ LAN ã³ãã¯ã¿ãè£ åããŠããããããã¯ãŒã¯æ¥ç¶ïŒ Telnet ïŒã§ã RS-232C æ¥ç¶ãšåæ§ãªã¢ãã¿ãŒããã³ã³ã³ãã ãŒã«ãå¯èœã§ãã 25/57 A12F-G2221 åæ±èª¬ææž 6.2 LED ã«ããã¢ãã¿ãŒ 6.2.1 ã³ã³ãããŒã©ã¢ãžã¥ãŒã«ã® LED ã¢ãã¿ãŒ ãªã¢ããã«ã«ã¯äžå³ã®ããã« 1âŒ6 çªã AâŒB ãŸã§ã® 8 åã® LED ããããæ¬¡è¡šã®ããã«å®çŸ©ãããŸãã LED Name Color Status 1 Ready ç·è² ç¹æ» ïŒã³ã³ãããŒã©åæåäž ONïŒã³ã³ãããŒã©ãæ£åžžã«åäœäž OFFïŒã³ã³ãããŒã©ã Ready ã«ãªã£ãŠããªã 2 Hst Bsy (Host Ports Active) ç·è² ç¹æ» ïŒã¢ã¯ã»ã¹äžããŸãã¯ããžãŒç¶æ OFFïŒã¢ã¯ã»ã¹ããŠããªã 3 Drv Bsy (Drive Ports Active) ç·è² ONïŒãã©ã€ãã«ã¢ã¯ã»ã¹äž OFFïŒã¢ã¯ã»ã¹ããŠããªã 4 N/A N/A N/A 5 C_Dirty ã¢ã³ã㌠ONïŒãã£ãã·ã¥ã¡ã¢ãªãŒã«ããŒã¿ãæ®ã£ãŠããããŸãã¯ã·ã¹ã ã ã®ãã¯ãŒãã¹ã«ãã BBU ãããŒã«ãã¢ããããŠãã ã¢ã³ã㌠ONïŒBBU æ éäžïŒãã£ãã·ã¥ã¡ã¢ãªãä¿æã§ããŠããªãç¶æ ïŒ ç¹æ» ïŒBBU å é»äž OFFïŒBBU æ£åžžïŒãã£ãã·ã¥ã¡ã¢ãªãä¿æã§ããŠããç¶æ ïŒ (*BBU ã¯ãªãã·ã§ã³ã§ããBBU ãè£ çãããŠããªãå Žåã¯ãåžž ã« OFF ã«ãªã£ãŠããŸãã) (Cache Dirty) 6 LED A BBU Fail Name Color Status CH0 LINK ç·è² ONïŒãã£ãã« 0 ããªã³ã¯ããŠãã OFFïŒãã£ãã« 0 ããªã³ã¯ããŠããªã B CH1 LINK ç·è² ONïŒãã£ãã« 1 ããªã³ã¯ããŠãã OFFïŒãã£ãã« 1 ããªã³ã¯ããŠããªã 26/57 A12F-G2221 åæ±èª¬ææž 6.2.2 LAN ããŒãã® LED ã¢ãã¿ãŒ Link Status Activity LED Name Color Status Online Status ç·è² ONïŒ LAN ãªã³ã¯ OK LAN Activity ç·è² ç¹æ» ïŒããŒã¿è»¢éäž 6.2.3 LCD ããã«ã® LED ã¢ãã¿ãŒ LED Name Color Status PWR éè² BUSY çœè² ATTEN èµ€è² ONïŒ é»æº ON OFFïŒ é»æº OFF ç¹æ» ïŒ ãã¹ã/ãã©ã€ããã£ãã« ããŒã¿ã¢ã¯ã»ã¹äž OFFïŒ ãã¹ã/ãã©ã€ããã£ãã« ããŒã¿ã¢ã¯ã»ã¹ããŠããªã ONïŒ ãµãã·ã¹ãã ãŸãã¯æ§æéšåã«äœããã®é害ããã£ã OFFïŒ ãµãã·ã¹ãã åã³ãã¹ãŠã®æ§æéšåãæ£åžžã«åäœäž 6.2.4 ãã©ã€ããã¬ã€ã® LED ã¢ãã¿ãŒ LED Name Drive Busy Color éè² Power Status ç·è² èµ€è² Status ç¹æ» ïŒ ãã©ã€ãã« Read/Write äž OFFïŒ ã¢ã¯ã»ã¹ããŠããªã ONïŒ ãã©ã€ã Ready ONïŒ ãã©ã€ãé害ããäœããã®é害ãçºç 27/57 A12F-G2221 åæ±èª¬ææž 6.2.5 黿ºãŠãããïŒPSUïŒã® LED ã¢ãã¿ãŒ Color ç·ç¹æ» ç·ç¹ç¯ èµ€ç¹ç¯ OFF Status ãµãã·ã¹ãã ã«é»æºã±ãŒãã«ãæ¥ç¶ãããŠããã黿ºãå ¥ã£ãŠããªã 黿ºã¯æ£åžžã«åäœäž 黿ºã¯æ éã§ã·ã¹ãã ã«çµŠé»ã§ããªã 黿ºãå ¥ã£ãŠããªãã 6.2.6 FAN ãŠãããã® LED ã¢ãã¿ãŒ èµ€ LED OFF ON Status FAN ãŠãããã¯æ£åžžã«åäœäž FAN ãŠãããã¯æ éã亀æãå¿ èŠ 6.2.7 BBU ã® LED ã¢ãã¿ãŒ èµ€ LED ON ã¹ããŒç¹æ» ON Status BBU æ éäž BBU å é»äž BBU æ£åžžïŒãã£ãã·ã¥ã¡ã¢ãªãä¿æã§ããŠããç¶æ ïŒ 28/57 A12F-G2221 åæ±èª¬ææž 6.3 ãã¶ãŒé³ã«ããã¢ãã¿ãŒ RAID ã³ã³ãããŒã©ã®åçš®ãã©ã¡ãŒã¿ïŒæž©åºŠãé»å§çïŒã決ããããç¯å²ãè¶ ããå Žåããã¶ãŒé³ã§ç¥ãããŸãã ãŸã ãµãã·ã¹ãã ã®åã³ã³ããŒãã³ãã«é害ããã£ãå Žåããã¶ãŒé³ã§ããããŸãã ãã®å Žåé害å 容㯠LCD ããã« ãŸãã¯ãPC ã¿ãŒããã«ã®ãšã©ãŒã¡ãã»ãŒãžã§å€æããŸãã ãã¶ãŒé³ãæ¶ãã«ã¯ãLCD ããã«ã® Muteâ ããŒã æŒããŸãã æ³šæ ã» ãã¶ãŒé³ãç¡èŠããŠé©åãªä¿®æ£ã¢ã¯ã·ã§ã³ããšããªãã§ã皌åãç¶ããå Žåã«ã¯ã·ã¹ãã ã®é倧ãªé害ãæä¹ çãªé害ãåŒãèµ·ããå ŽåããããŸãã 6.3.1 ãã¶ãŒé³ã«ããã¢ã©ãŒã ã®ãã©ã¡ãŒã¿äžéãäžéã®ããã©ã«ãå€ äžèšãã©ã¡ãŒã¿ã®äžéãäžéãè¶ ããå Žåã¢ã©ãŒã é³ã§ç¥ãããŸãã Parameter +3.3V +5V +12V CPU Temperature Board Temperature Enclosure Ambient Temperature Upper Threshold +3.6V +5.5V +13.2V 90ºC 90ºC 40ºC Lower Threshold +2.9V +4.5V +10.8V 0ºC 5ºC 0ºC 6.3.2 æ éã®å Žåãã¶ãŒé³ã§ã¢ã©ãŒã ãåºãã³ã³ããŒãã³ã äžèšã®ã³ã³ããŒãã³ãã«é害ããã£ãå Žåãã¶ãŒé³ã«ããã¢ã©ãŒã ãåºããŸãã ã» RAID ã³ã³ãããŒã©ã¢ãžã¥ãŒã« ã» FAN ãŠããã ã» PSUïŒé»æºãŠãããïŒ ã» BBUïŒããããªãŒããã¯ã¢ãããŠãããïŒ ã» HDDïŒãã£ã¹ã¯ãã©ã€ãïŒ 6.3.3 I2C ã¢ãã¿ãªã³ã° åã¢ãžã¥ãŒã«ã®ç¶æ ç£èŠã¯I2C ã·ãªã¢ã«ãã¹ã䜿çšããŠããŸãã ããã«ãã£ãŠã¢ãžã¥ãŒã«ã«é害ããã£ãå Žåã«æ€ ç¥ããçš®ã ã®äžèšã®ãããªçš®ã ã®æ¹æ³ã§èŠåããŸãã 29/57 A12F-G2221 åæ±èª¬ææž 6.4 LCD ãã£ã¹ãã¬ã€ã«ããã¢ãã¿ãŒ LCD ããã«ã® LCD Push-button Panel ã§ããŒæäœã«ãã詳现ãªã€ãã³ããã°ã®ã¢ãã¿ãŒãå¯èœã§ãã ïŒïŒåãŸã§ã³ ã³ãããŒã©å èµã¡ã¢ãªãŒã«èšé²ãããŸããã黿ºãåããšå šãŠã®ãã°ãæ¶ããŸãŠããŸããŸãã é害æã«ã¯ã黿ºãåã åã«å¿ ãã€ãã³ããã°ãã¡ã¢ããŠãã ããã ãã®ãã°ã確èªããæ¹æ³ã次ã«èª¬æããŸãã âLED ã«ããã¹ããŒã¿ã¹è¡šç€º PWRïŒ éè²----黿º ON æã«ç¹ç¯ã BUSYïŒ çœè²-----I/O ãè¡ãããŠããæã«ç¹æ» ã ATTENïŒ èµ€è²-----é害æã«ç¹ç¯ã âMUTE ããŒïŒ ã¢ã©ãŒã é³ã®è§£é€ çŸåšã® LCD ç»é¢ã®ã¹ããŒã¿ã¹ã確èªäžããã çŸåšã®è¡šç€ºã¯ææ°ã®ãšã©ãŒã¡ãã»ãŒãžã§ãã®ã§ã確èªåŸãESCããã¿ã³ãæŒããŠäžèšã®åæç»é¢ã«æ»ããŸãã A12F-G2221 Ready æ¬äœ LCD éšã®æäœããŒã«ãŠä»¥äžã®ç¢ºèªãããŠäžããã äžèšç¶æ ãããENTERãããŒã 2 ç§ä»¥äžæŒãç¶ããŸãã æŒããæã«ãPress 2 seconds for Main menuããšè¡šç€ºããã Quick Logical Drive Install â ãšè¡šç€ºãããŸãã®ã§ãâœããŒã 10 åçšåºŠæŒããŸãã View and Edit Event Logs â ã衚瀺ãããŸãã®ã§ãããã§ãENTERããã¿ã³ãæŒããŸãã Controller Init Completed SLOT=3 BadBlock Encountered é害çºçæã«ã¯äŸãã°ãã®ãããªè¡šç€ºãåºãŸãã â³âœãã¿ã³ã§ååŸããŸãã®ã§ãå 容ãã確èªããŸãããã®æ å ±ãã 黿ºãå ¥ããŠãããã³ã³ãããŒã©ã«èšæ¶ãããŠãã RAID è£ çœ®ã®ã€ãã³ãã§ãã æå€§æ°ã 99 åã«ãªã£ãŠãããå€ãé ã«æ¶å»ãããŸãã ã€ãã³ãã¡ãã»ãŒãžã®å 容詳现㯠CDROM ããã¥ã¢ã«ã® Generic Operation Manual GMN1.xx.pdf ãåç §ããŠãã ããã 30/57 A12F-G2221 åæ±èª¬ææž 6.5 PC ã¿ãŒããã«ã«ããã¢ãã¿ãŒ Event Log ã®ç¢ºèªã¯ HyperTerm çã®æ±çšéä¿¡ãœããïŒVT-100ïŒã§ã¢ãã¿ãŒããäºãã§ããŸãã æ¥ç¶ã¯ãä»å±ã® RS-232C ã±ãŒãã«ãš Null Modem ã䜿çšãåçã®ããã«æ¥ç¶ããŸãã ãŸãã€ãŒãµããã(Telnet)ã§ã®æ¥ç¶ãå¯èœã§ãã 衚瀺å 容ã¯ã©ã¡ãã®æ¥ç¶æ¹æ³ã§ãåãã§ãã PCã®RS232Cãšæ¥ç¶ æ¬æ©ã®RS-232C (ïŸïŸïœšïœµïœŒïŸïœ¬ïœ¯ïœž) ãšæ¥ç¶ RS-232C ã®èšå® Baud rate 38400bps Data bits 8 Stop bit 1 Parity None äžå³ã¯ã¿ãŒããã«ãéããæã®åæç»é¢ã§ãã ç»é¢ãéããªãå Žå Ctrl ããŒãš L ããŒãåæã«æŒããŸãã ãããã View and edit Event logs ãéžæããŸãã äžå³ã¯ Event Log ãéããæã®äŸã§ãã 31/57 A12F-G2221 åæ±èª¬ææž 7. æ¬æ©ã®æ¥ç¶ãšãªãã¬ãŒã·ã§ã³ 7.1 FC ã€ã³ã¿ãŒãã§ãŒã¹ FC ã±ãŒãã«ã®ã³ãã¯ã¿ã¯ TX/RX ãééããªãããã« DLCïŒãã¥ã¢ã« LC ã³ãã¯ã¿ïŒã¿ã€ãããå§ãããŸãã SFP ã¢ãžã¥ãŒã«ã¯ LC ã¿ã€ãã䜿çšããŠãã ããã äžèšã®æ³šæäºé ãå®ã£ãŠæ£ãã䜿çšããŠãã ããã æ³šæ ã» ã» ã» FC ã±ãŒãã«ã¯æ²ãã«å¯ŸããŠããªã±ãŒããªéšåã§ãã æ²ããå Žåã¯ååŸ 50mm 以äžã«ããŠãã ããã ãŸãã©ãã¯çµèŸŒã¿/åãå€ãæã«ã±ãŒãã«ã«ç¡çãªåãå ãããªãããã«ããŠãã ããã FC ã¬ãŒã¶ãŒã¯ç®ã«å¯ŸããŠé倧ãªé害ãäžããäºããããŸãã ã¬ãŒã¶ãŒã® ON/OFFãç®ã§ç¢ºèªããäºã¯çµ¶ 察ã«é¿ããŠãã ããã FC ã±ãŒãã«ããã³ SFP ã¢ãžã¥ãŒã«ã¯ä¿¡é Œæ§ã«éèŠãªåœ±é¿ãäžããéšåã§ãã å¿ ãæå®åãã䜿çšãã ããã 7.2 æ¬æ©ã®æ¥ç¶äŸ 7.2.1 ãã¡ã€ããŒãã£ãã«ã®æ¥ç¶åœ¢æ æ¬æ©ã¯ FC æšæºèŠæ Œã§å®ãããPoint-to-PointãFC-ALãFabric Switch ã®ïŒã€ã®æ¥ç¶åœ¢æ ã«å¯Ÿå¿ããŠããŸãã âPoint-to-Point Point-to-Point ã¯æãç°¡åãªæ¥ç¶åœ¢æ ã§ã2 ã€ã® FC ããã€ã¹ãçŽæ¥æ¥ç¶ããŸãã âFC-AL FC-AL ã§ã¯å šãŠã® FC ããã€ã¹ã¯ã«ãŒãç¶ã«æ¥ç¶ãããAL_PAïŒArbitrated Loop Physical AddressïŒã«ãã£ãŠäžã€ ã®ã«ãŒãã«ã€ãïŒïŒïŒåã®ã¢ãã¬ã¹ãåã§åããã€ã¹ã«å²ãåœãŠãããŸãã âFabric Switch ãã¡ã€ããŒãã£ãã«ã¹ã€ãããå©çšããŠè€æ°ã® FC ããã€ã¹ãåæã«éä¿¡ããããšãã§ããŸãã 32/57 A12F-G2221 åæ±èª¬ææž 7.2.2 ã·ã³ã°ã«ãã¹ãæ¥ç¶äŸ âã¯ã©ã¹ã¿ãŒãã¹ãâ æ¬¡å³ã¯æ¬æ©ã®æ¥ç¶äŸã®äžã€ã§ãã1 å°ã® A12F-G2221 ãµãã·ã¹ãã ã 2 ã€ã®ã¯ã©ã¹ã¿ãŒãµãŒããŒãšæ¥ç¶ãããŠã㟠ããæ¬¡ã®ããã«æ§æãããšãããŒã¿ãã¹ã«åé·æ§ãæãããããšãã§ããŸãã ïŒïŒ2 ã€ã®ã³ã³ãã¥ãŒã¿ãã¯ã©ã¹ã¿ã§ããããšã 2ïŒHA ã¢ã¯ã»ã¹ãœãããŠã§ã¢ã³ã³ãããŒã«ãæå¹ãªç¶æ ã§ããããšã 3ïŒã¹ãã¬ãŒãžããªã¥ãŒã ãããããã®ãã¹ãããŒãã«å²ãåœãŠãããŠããããšãäžæ¹ã®ãã¹ãã³ã³ãã¥ãŒã¿ã«é害ãçºç ãããšãããäžæ¹ã®æ£åžžãªãã¹ãã³ã³ãã¥ãŒã¿ã¯ãµãã·ã¹ãã ã«ã¢ã¯ã»ã¹ããããšãã§ããã 7.2.3 ã·ã³ã°ã«ãã¹ãæ¥ç¶äŸ âãã€ã¬ã¯ãæ¥ç¶â 次å³ã¯æ¬æ©ã®æ¥ç¶äŸã®äžã€ã§ããA12F-G2221 ãµãã·ã¹ãã ãã·ã³ã°ã«ãã¹ãã³ã³ãã¥ãŒã¿ãšæ¥ç¶ãããŠããŸããæ¬¡ ã®ããã«æ§æãããšãããŒã¿ãã¹ã«åé·æ§ãæãããããšãã§ããŸãã ïŒïŒHA ã¢ã¯ã»ã¹ãœãããŠã§ã¢ã³ã³ãããŒã«ãæå¹ãªç¶æ ã§ããããšã 2ïŒã¹ãã¬ãŒãžããªã¥ãŒã ãããããã®ãã¹ãããŒãã«å²ãåœãŠãããŠããããšããã¹ããããŒãžã¡ã³ããœãããŠã§ã¢ã¯ã ã·ã³ã°ã«ãã¹ã«é害ãèµ·ãããšãæ®ã£ãŠãããã¹ãéããŠããŒã¿ãçŽæ¥ã¢ã¯ã»ã¹ããã 33/57 A12F-G2221 åæ±èª¬ææž 7.3 黿ºã®æå ¥ 7.3.1 黿ºæå ¥åã« é»æºãå ¥ããåã«äžèšã®é ç®ããã§ãã¯ããŠãã ããã ã» ã» ã» ã» ã» ã» ã¡ã¢ãªãŒ ïŒ æ°ããã¡ã¢ãªãŒãã€ã³ã¹ããŒã«ããå Žåã³ã³ãããŒã©ããŒãã«æ£ããåä»ããããŠããŸããïŒ BBU ã¢ãžã¥ãŒã« ïŒ BBU ã¢ãžã¥ãŒã«ãã€ã³ã¹ããŒã«ããå Žåãæ£ããåä»ããããŠããŸããïŒ HDD ïŒ HDD ã¯ãã¬ã€ã«æ£ããåä»ããããŠããŸããïŒ HDD ãã¬ã€ ïŒ HDD ãåä»ããããŠãããããªãã«ããããããå šãŠã®ãã¬ã€ãæ¿å ¥ãããŠããŸããïŒ ã±ãŒãã«æ¥ç¶ ïŒ ãã¹ãããŒãã¯ãã¹ã PC ãšæ£ããæ¥ç¶ãããŠããŸããïŒ é»æºã±ãŒãã« ïŒ ä»å±ã® 2 æ¬ã®é»æºã±ãŒãã«ãå PSU ã¢ãžã¥ãŒã«ã«æ¥ç¶ãã ã³ã³ã»ã³ããã¢ãŒã¹ä»ãïŒïŒPïŒã«æ¥ç¶ããŠããŸããïŒ ã» ç°å¢æž©åºŠ ïŒ ã©ãã¯å ã®æž©åºŠã¯èŠæ Œå ã«å ¥ã£ãŠããŸããïŒ 7.3.2 黿ºæå ¥ã®é çª Step1 Step2 Step3 Step4 Step5 黿ºæå ¥åã®ãã§ãã¯ãå®äºããã æ¬æ©ã« FC æ¥ç¶ããŠãããããã¹ã€ããçã®é»æºãå ¥ããã JBOD ãæ¥ç¶ããŠããå Žåã¯ããã®é»æºãå ¥ããã æ¬æ©ã®é»æºãå ¥ããã æ¬æ©ã®é»æºã¹ã€ããã¯å PSUïŒé»æºãŠãããïŒã®å³åŽã«ãããŸãã ãã¹ã PC ã®é»æºãå ¥ããã æ³šæ PSU ã¯åé·æ§ãæããããã 2 åãããŸãã ã©ã¡ããäžæ¹ã ãã§ãåäœã¯å¯èœã§ãããåé·æ§ãç¡ããªãã ãã®é»æºãæ éãããšã·ã¹ãã ãã¯ã©ãã·ã¥ããŸãã å®å šã®ããã«å¿ ãäž¡æ¹ã®ã¹ã€ãããå ¥ããŠãã ããã 34/57 A12F-G2221 åæ±èª¬ææž 7.3.3 黿ºæå ¥æã®ç¶æ ãã§ãã¯ æ¬æ©ã®é»æºãå ¥ããŠãã Ready ç¶æ ã«ãªããŸã§ã«æ°åç§ããããŸãã ãã®éã«ã·ã¹ãã ã®ã»ã«ããã§ãã¯ãèªåç ã«è¡ãããç°åžžããªããã確ãããŸãã ãã®éã® LEDããã¶ãŒé³ãLCD ã®ç¶æ ã¯æ¬¡ã®éãã§ãã®ã§ç¢ºèªããŠãã ããã â ãã©ã€ããã¬ã€ã® LED ã€ãã·ã£ã©ã€ãºäžã¯é LED ãç¹æ» ãReady ç¶æ ã«ãªããšé LED ãç¹ç¯ããŸãã â LCD ããã«ã® LED 黿ºãå ¥ããšé LED ç¹ç¯ã ã€ãã·ã£ã©ã€ãºäžã¯èµ€ LED ãç¹ç¯ããReady ç¶æ ã«ãªããšæ¶ç¯ããŸãã â ã¢ã©ãŒã é³ ã€ãã·ã£ã©ã€ãºã¹ã¿ãŒãæã«ããŒããŒé³ãäžåºŠé³ŽããŸãã ã€ãã·ã£ã©ã€ãºæã«äœããã®ç°åžžãæ€åºãããšã ããŒããŒãé£ç¶ããŠé³Žãç¶ããŸãã â LCD ãã£ã¹ãã¬ã€ ãã¹ãã®èšå®ãæžãã§ããå ŽåãReady ç¶æ ã«ãªããšäžèšã®è¡šç€ºã«ãªããŸãã ãã¹ãã®èšå®ãè¡ãããŠããªãå ŽåãReady 衚瀺ã«ãªãããâ No Host LUN â ã衚瀺ããŸãã Model Name A12F-G2221 Ready Status/Data Transfer Indicator InitializingâŠ. Please Wait... 黿ºã ON ãããšã€ãã·ã£ã©ã€ãºãå§ãŸãã ãã®è¡šç€ºã«ãªããŸãã A12F-G2221 Modem Not Config ã€ãã·ã£ã©ã€ãºåŸã¢ãã«åã衚瀺ããŸãã A12F-G2221 256MB RAM, Wait⊠RAM 容éã衚瀺ããŸã A12F-G2221 No Host LUN ãã¹ãèšå®æžã¿ã®å Žå㯠Ready ã æªèšå®ã®å Žå㯠No Host LUN ã衚瀺ããŸãã 35/57 A12F-G2221 åæ±èª¬ææž 7.4 黿ºã®åææé 黿ºã OFF ã«ããå Žåã¯æ¬¡ã®æé ã§è¡ããŸãã Step1 Step2 Step3 StepïŒ ãã¹ã PC ããã®å šãŠã® I/O ã¢ã¯ã»ã¹ãæ¢ããŸãã ããŒã¿ããã£ãã·ã¥ã¡ã¢ãªãŒã«æ®ã£ãŠããªãäºã確èªããŸãã LCD ããã«ã® BUSY LED ãç¹ç¯ããŠãå Žåã¯ããŒã¿ããã£ãã·ã¥ã¡ã¢ãªãŒã«æ®ã£ãŠããŸãã ããŒã¿ããã£ãã·ã¥ã¡ã¢ãªãŒã«æ®ã£ãŠããå Žå㯠LCD ããã«ããŒæäœã§ Shutdown Controller ãå®è¡ã ãã£ãã·ã¥ãããŠããããŒã¿ããã©ãã·ã¥ããŸãã 黿ºã¹ã€ããïŒïŒåïŒã OFF ããŸãã 36/57 A12F-G2221 åæ±èª¬ææž 7.5 RAID ã®æ©èœ 7.5.1 è«çãã©ã€ãïŒLogical DriveïŒ è«çãã©ã€ããäœæããããšã§ RAID ã®æå¹æ§ãèœåãããã©ãŒãã³ã¹ãçºæ®ã§ããŸããè«çãã©ã€ããšã¯ OS ããèª èãããç©çãã©ã€ãã®äžéšãããã¯è€æ°ã®ç©çãã©ã€ãããããŸããè«çãã©ã€ãã¯ããŒã«ã«ãªããŒããã£ã¹ã¯ãã©ã€ ããšåãããã«é£ç¶ããããªã¥ãŒã ãšããŠãã¹ãããèŠããŸãã æ¬¡ã®ã»ã¯ã·ã§ã³ã§ã¯ã¹ããã³ã°ããã©ãŒãªã³ã°ãããŒã¿ããªãã£ã®ãããªè«çãã£ã¹ã¯ãã©ã€ããäœãããŸããŸãªæ¹æ³ã âRAID levelsâã®é ç®ã§ç޹ä»ããŸãã 7.5.2 è«çããªã¥ãŒã ïŒLogical VolumeïŒ è«çããªã¥ãŒã ã®æŠå¿µã¯è«çãã©ã€ãã®æŠå¿µã«éåžžã«é¡äŒŒããŠããŸããè«çããªã¥ãŒã 㯠1 ã€ãããã¯ããã€ãã®è« çãã©ã€ãã®çµã¿åããã§ãããããè«çãã©ã€ãã¯ãã倧ããªå®¹éã®äžã« RAID 0 (striping)ã䜿ã£ãŠçµåãããŠã ãŸããè«çããªã¥ãŒã ã«ããŒã¿ãæžã蟌ãŸãããšãã«ã¯ãããŒã¿ã¯ãŸãå§ãã«éšååãããè«çããªã¥ãŒã ã®äžã®è« çãã©ã€ãã«éšåããããããŒã¿ãé çªã«åæ£ããŠæžã蟌ãŸããŸããããããã®è«çãã©ã€ããæ§æããŠããç¹å®ã® RAID ã¬ãã«ã«åŸã£ãŠã¡ã³ããŒã®ãã©ã€ãã«éšååãããããŒã¿ãåããŠèšé²ããŸãã åãRAIDã¬ãã«ãããã¯ç°ãªãRAIDã¬ãã«ããããã§è«çãã©ã€ãã®ã¡ã³ããŒãæ§æããããšãã§ããŸããè«çã ãªã¥ãŒã ã¯æå€§ïŒïŒã®ããŒãã£ã·ã§ã³ã«åããããšãã§ããŸãããããŠããã¹ãããã¯ããŒãã£ã·ã§ã³ãåãããŠããªãè« çããªã¥ãŒã ã§ãããŒãã£ã·ã§ã³ã®åãããè«çããªã¥ãŒã ã§ãïŒã€ã®ç©çãã©ã€ããšããŠèŠãããšãã§ããŸãã 7.5.3 RAID ã¬ãã« RAID ãšã¯ç¬ç«ããè€æ°å°ã®ãã£ã¹ã¯ãçµã¿åãããŠåé·åãããïŒå°ã®ããŒããã£ã¹ã¯ãšããŠç®¡çããæè¡ã®ããšã§ ããRAID ã¹ãã¬ãŒãžã»ãµãã·ã¹ãã ã䜿ãããšã¯ä»¥äžã®ãããªå©ç¹ããããŸãã ã» ïŒã€ã®ããªã¥ãŒã ã®äžã«æ¥ç¶ããããã¹ãŠã®ãã©ã€ãã®å®¹éãç¡é§ãªã䜿çšããããšãã§ããŸãã ã» è€æ°å°ã®äžŠåã«æ¥ç¶ããããã©ã€ãã«èªã¿èŸŒã¿/æžã蟌ã¿ããããšããããã€ãã®ãããã¯ã«ããŒã¿ããã㊠ãã£ã¹ã¯ãžã®ã¢ã¯ã»ã¹éåºŠãæ©ãããŸããããããã®ãã©ã€ããæ¥ç¶ãããã£ã³ãã«ãã¹ãèš±å¯ãããã°ãã ã»ã©èšæ¶è£ 眮ã®é床ã¯å¢ããŸãã ã» ãã©ãŒãªã³ã°ãããªãã£ã«ãã£ãŠé害ãžã®èæ§ãæäŸããŸãã RAID Level Description Capacity NRAID Non-RAID N RAID 0 Disk Striping N RAID 1 (0+1) Mirroring Plus Striping (if N>1) N/2 Data Availability ==NRAID >>NRAID ==RAID 5 RAID 3 Striping with Parity on dedicated disk N-1 >>NRAID ==RAID 5 RAID 5 Striping with interspersed parity N-1 >>NRAID ==RAID 5 RAID 10 Striping with RAID 1 logical drives / >>RAID 5 (Logical Volume) RAID 30 Striping with RAID 3 logical drives / >>NRAID >>RAID 5 (Logical Volume) RAID 50 >>NRAID Striping with RAID 5 logical drives / >>NRAID >>RAID 5 (Logical Volume) 37/57 A12F-G2221 åæ±èª¬ææž â» è«çãã©ã€ãã®äžã«ç°ãªããã£ã³ãã«ã§æ¥ç¶ããããã©ã€ããè«çãã©ã€ãã«å«ããããšãã§ããŸãããããŠè«çã ãªã¥ãŒã ãæ§æããããã«ãç°ãªã RAID ã¬ãã«ã®è«çãã©ã€ãã䜿ãããšãã§ããŸããããã«ãRAID 10,30,50 ãšã㣠ãå€ãã®çµã¿åããããããŸãã RAID Level Performance Random NRAID Drive Drive RAID 0 R: Highest R: High W: Highest W: Highest R: High R: Medium W: Medium W: Low R: High R: Medium W: Medium W: Low RAID 1 (0+1) RAID 3 RAID 5 NRAID Performance Sequential R: High R: High W: Medium W: Low Disk Spanning NRAID ã¯é RAID ãæå³ããŸããæ¥ç¶ããããã©ã€ãã®å®¹éã¯ãã¹ãŠçµåããïŒã€ã®è«çãã©ã€ãã«ãªããŸã(ããã ã¯ãã¹ãã©ã€ãã³ã°ããŸãã)ãã€ãŸãè«çãã©ã€ãã®å®¹éã¯æ¥ç¶ãããç©çãã©ã€ãã®ã¡ã³ããŒå šäœã®å®¹éã«ãªããŸãã NRAID ã«ã¯ããŒã¿ã®åé·æ§ã¯ãããŸããã NRAID Minimum Disks 1 required Capacity N Redundancy No JBOD JBOD ã¯âJust a Bunch of Drivesâã®ç¥ã§ããã³ã³ãããŒã©ãŒã¯ç¬ç«ãããã£ã¹ã¯ãšããŠããããã®ãã©ã€ããæ±ãã®ã§ã ç¬ç«ããè«çãã©ã€ãã«ãªããŸããJBOD ã«ã¯åé·æ§ã¯ãããŸããã JBOD Minimum Disks 1 required Capacity 1 Redundancy No 38/57 A12F-G2221 åæ±èª¬ææž RAID 0 Disk Striping RAID 0 ã¯é«ãããã©ãŒãã³ã¹ãçºæ®ããŸãããåé·æ§ã¯ãããŸãããè«çãã©ã€ãã®ããŒã¿ã¯è€æ°å°ã®ç©çãã©ã€ ãã«ãŸããã£ãŠèšé²ãããŸãã RAID 0 Minimum Disks 2 required Capacity N Redundancy No RAID 1 Disk Mirroring RAIDïŒã¯ 2 å°ã®ãã©ã€ãã䜿ããããããŒããã©ã€ãã«èšæ¶ãããããŒã¿ãããïŒã€ã®ããŒããã©ã€ãã«ã³ããŒããŸãã æŽã«ããïŒå°ã®ãã©ã€ããããã°èªåçã« RAID(0+1)ãé©çšãããŸãã RAID 1 Disks required Capacity Redundancy RAID (0+1) 2 N/2 Yes Disk Striping with Mirroring RAID(0+1) 㯠RAIDïŒã®ã¹ãã©ã€ãã³ã°ãš RAIDïŒã®ãã©ãŒãªã³ã°ã®æ©èœã䜵ãæã£ãŠããŸããRAID(0+1)ã«ã¯ããŒãã ã©ã€ãã«ååãªåé·æ§ããããããå€éãã©ã€ãé害ã«èä¹ æ§ãçºæ®ããŸããRAID1 ãæ§ç¯ãããšããæŽã« 2 å°ã®ã ãŒããã©ã€ããããã° RAID(0+1)ãèªåçã«é©çšãããŸãã RAID (0+1) Minimum Disks 4 required Capacity N/2 Redundancy Yes ïŒéèŠïŒ âRAID (0+1)âã¯ã³ã³ãããŒã©ãŒããµããŒãããŠãã RAID ã¬ãã«ã«è¡šç€ºãããŸãããRAID1 ãæ§ç¯ãããšãã«ã³ã³ãã ãŒã©ãŒã RAID1 ããã㯠RAID(0+1)ãã©ãããè«çãã©ã€ããæ§æãããã©ã€ãã®æ°ã«ãã£ãŠèªåçã«æ±ºå®ããŸãã 39/57 A12F-G2221 åæ±èª¬ææž RAID 3 Disk Striping with Dedicated Parity Disk RAIDïŒã¯ããªãã£ãšäžç·ã«ãããã¯æ¯ã«ã¹ãã©ã€ãã³ã°ãè¡ããŸããã¡ã³ããŒãã©ã€ãã® 1 å°ãããªãã£ããŒã¿ã®èšé²ã å°éã«è¡ã£ãŠããã1 å°ã¡ã³ããŒãã©ã€ããæ éãããšãã«ã¯ãä»ã®ãã©ã€ãäžã®ããŒã¿ãæ¯èŒãåèšç®ããããšã§æ é ãã©ã€ãã®å€±ãããããŒã¿ã埩æ§ããããšãã§ããŸãã RAID 3 Minimum Disks 3 required Capacity N-1 Redundancy Yes RAID 5 Striping with Interspersed Parity RAID5 㯠RAID3 ã«äŒŒãŠããŸãããããªãã£ããŒã¿ãå°çšã®ããŒããã©ã€ãã«èšé²ãããŠããŸãããããªãã£æ å ±ã¯è€ æ°ã®ç©çãã©ã€ãã«ç¹åšããŠããã ãã©ã€ããæ éãããšãã«ã¯ã1å°ã¡ã³ããŒãã©ã€ããæ éãããšãã«ã¯ãä»ã®ãã©ã€ ãäžã®ããŒã¿ãæ¯èŒãåèšç®ããããšã§æ éãã©ã€ãã®å€±ãããããŒã¿ã埩æ§ããããšãã§ããŸãã RAID 5 Minimum Disks 3 required Capacity N-1 Redundancy Yes 7.5.4 Spare Drives Local Spare Drives Local Spare Drive ã¯ããæå®ãããè«çãã©ã€ãã ãµããŒãããããã«å²ãåœãŠããããã©ã€ãã§ããæ å®ãããè«çãã©ã€ãã®ã¡ã³ããŒãæ éããå Žåã Local Spare Drive ã¯ã¡ã³ããŒã«ãªããèªåçã«ãªã ã«ããå§ããŸãã 40/57 A12F-G2221 åæ±èª¬ææž Global Spare Drives Global Spare Drive 㯠1 ã€ã®æå®ãããè«çãã©ã€ã ã ãããµããŒãããã®ã§ã¯ãªããä»ã®ã©ã®è«çãã©ã€ã ã®ã¡ã³ããŒãæ éããŠããGlobal Spare Drive ã¯ã¡ã³ã ãŒã«ãªããèªåçã«ãªãã«ããå§ããŸãã Global Spare Rebuild å·Šã®äŸã¯ Local Spare Drive ãš Global Spare Drive äž¡ æ¹ãæ©èœããŠããŸããç¹å®ã®å Žåã«ãããŠããããïŒ ã€ã®æ©èœãäžç·ã«äœ¿ãããšã¯æ§ã ãªããŒãºã«é©çšã§ã ãã§ããããLocal Spare Drive 㯠Global Spare Drive ãããåžžã«é«ãåªå é äœãæã£ãŠããããšãèŠã ãŠãããŠãã ããã Mixing Local and Global Spares 4GB ã® Global Spare Drive ã¯å®¹éãäžååãªããã è«çãã©ã€ã 0 ã®ã¡ã³ããŒã«ãªãããšã¯ã§ããªãããã ããè«çãã©ã€ã 1 ãŸã㯠2 ã®æ éãããã©ã€ãã®ãã ã« Global Spare Drive ãšã㊠9GB ã®ãã©ã€ãã䜿ãããš ã¯ããããã®è«çãã©ã€ã 1 ãŸã㯠2 㯠4GB ããå¿ èŠãš ããªãã®ã§å®¹éãè¶ããéšå(5GB)ã¯ç¡é§ã«ãªã£ãŠã ãŸããŸããå³ã®è«çãã©ã€ã 0 ã®ã¡ã³ããŒãã©ã€ããæ éããå Žåã«ã¯ã9GB ã® Local Spare Drive ããã®è« çãã©ã€ããã¡ã³ããŒãã©ã€ãã«ãªãã§ãããããŸããè« çãã©ã€ã 1 ãŸã㯠2 ã®ã¡ã³ããŒãã©ã€ããæ éãã㪠ããããã« 4GB ã® Global Spare Drive ãã¡ã³ããŒãã© ã€ãã«ãªãã§ãããã 41/57 A12F-G2221 åæ±èª¬ææž 7.6 RAID ã®åæåäœæ¥ 泚æ ã»RAID ã®åæåãè¡ããšãå šãŠã®ããŒã¿ã倱ãããŸãã å¿ èŠãªããŒã¿ãå ¥ã£ãŠããå Žåã¯å¿ ãããã¯ã¢ãã ããšã£ãŠããè¡ã£ãŠãã ããã ã»éåžžãåºè·æã«åæåãå®äºããŠããŸãã®ã§ãã®äœæ¥ã¯å¿ èŠãããŸããã 7.6.1 å Drive Status ããã³çŸåšã® Logical Drive Status ã®ç¢ºèª åæåã®åã«åãã©ã€ãã®ç¶æ ãšçŸåšã® Logical Drive ã®ç¶æ ã確èªããŸãã ã» ãã©ã€ããå ¥ã£ãŠããå šãŠã®ãã¬ã€ã®é LEDïŒReadyïŒã®ã¿ãã€ããŠããããšã確èªããŸãã ã» LCD äžã«ä»¥äžã®ã©ã¡ããã®ã¡ãã»ãŒãžã衚瀺ãããŠããããšã確èªããŸãã A12F-G2221 No Host LUN A12F-G2221 Ready æ¢ã«äœããã®åæåãšãã¹ãèšå®ãå®äºããŠããå Žåãå³å³ã®è¡šç€ºã«ãªããŸãã ã» LCD ããã«ã®æäœã«ããåãã©ã€ãã®ã¹ããŒã¿ã¹ã確èªããæå®ã®ãã©ã€ããæ£ããèªèãããŠããããšã確èªã㟠ãã Main Menu å View and Edit SCSI Drives ã«ãŠç¢ºèªã§ããŸãã äžå³ã®ã©ã¡ããã®ç¶æ ããäžèšã®ããŒæäœãããŸãã Press 2 seconds For Main Menu â ENT ããŒãé·æŒãããŸãã Quick Logical Drive Install â âŒããŒãïŒåæŒããŸãã View and Edit SCSI Drives â ENT ããŒãæŒããŸãã SLOT=2 035003MB LG=0 LN SEAGATE ïŒLCD è¡šç€ºã®æå³ïŒ SLOT=2ïŒ Drive SLOT 035003MBïŒ Drive Capacity LG=0ïŒ Logical Drive No.0 LNïŒ Drive Status (Online) Drive Vender âŒããŒãæŒããé çªã«å šãã©ã€ãã確èªããŸãã 䞻㪠LCD 衚瀺 IN LN RB SB Global SB NEW DRV BAD DRV ABSENT MISSING SB-MISS ãã©ã€ãã¹ããŒã¿ã¹ ã€ãã·ã£ã©ã€ãºäž ãªã³ã©ã€ã³ïŒæ£åžžïŒ ãªãã«ãåäœäž ããŒã«ã«ã¹ãã¢ãã©ã€ã ã°ããŒãã«ã¹ãã¢ãã©ã€ã æªäœ¿çšãã©ã€ã ç°åžžïŒé害çºçïŒãã©ã€ã ååšããªããã©ã€ã ååšããŠãããã©ã€ãããªãããã®é害ã«ãŠæ¶å€±ãã ååšããŠããã¹ãã¢ãã©ã€ãããªãããã®é害ã«ãŠæ¶å€±ãã 42/57 A12F-G2221 åæ±èª¬ææž ã» LCD ããã«ã®æäœã«ãã Logical Drive ã®ã¹ããŒã¿ã¹ã確èªããŸãã Drives ã«ãŠç¢ºèªã§ããŸãã Main Menu å View and Edit Logical åæç»é¢ããäžèšã®ããŒæäœãããŸãã Press 2 seconds For Main Menu â ENT ããŒãé·æŒãããŸãã Quick Logical Drive Install â âŒããŒã 1 åæŒããŸãã View and Edit Logical Drives â ENT ããŒãæŒããŸãã LG=0 RAID5 DRV=12 373GB GD SB=0 ïŒLCD è¡šç€ºã®æå³ïŒ LG=0ïŒ Logical Drive 0 RAID5ïŒ RAID Level DRV=12ïŒ Drive æ° ïŒïŒïŒGBïŒLogical Drive ã®å®¹é GDïŒ Logical Drive Status Good SB=0ïŒãã® Logical Drive ã® Spare Drive æ° âŒããŒãæŒããé çªã«å šãã©ã€ãã確èªããŸãã ã»äž»ãª RAIDïŒè«çãã©ã€ãïŒã¹ããŒã¿ã¹ LCD 衚瀺 ãã©ã€ãã¹ããŒã¿ã¹ ã€ãã·ã£ã©ã€ãºäž INITING I/O ãµã€ãºïŒã©ã³ãã I/O ãŸãã¯ã·ãŒã±ã³ã·ã£ã« I/O ã©ã¡ããã«æé©åããçºïŒã INVALID äžæŽå æ£åžž GD è«çãã©ã€ããæ§æããŠããç©çãã©ã€ããäžå° FAILïŒé害ïŒããŠãã FL è«çãã©ã€ãããªãã«ãåäœäž RB è«çãã©ã€ããæ§æããŠããç©çãã©ã€ãã®äžå°ãèªèã§ããªãã£ã DRVMISS è«çãã©ã€ããæ§æããŠããç©çãã©ã€ããè€æ°å° FAILïŒé害ïŒããŠãã INCOMPLETE ARRAY 7.6.2 RAID ã®åæå â èšå®ãããŒâ ïŒQuick Logicaïœ Drive Install ã䜿çšããå ŽåïŒ ïŒãã¡ãŒã ãŠãšã¢ã®ããŒãžã§ã³ã«ãã衚瀺ãç°ãªãå ŽåããããŸããïŒ A12F-G2221 No Host LUN â ENT ããŒãæŒããŸãã Press 2 seconds for Main Menu â ENT ããŒãé·æŒãããŸãã Quick Logical Drive Install â ENT ããŒãæŒããŸãã Set TDRV=X with â LG RAID5+Spare â âœâ³ããŒã§èšå®ãã RAID ã¬ãã«ãéžæãã ENT ããŒãæŒããŸãã ( X ã¯ãã©ã€ãã®æ°) 43/57 A12F-G2221 åæ±èª¬ææž Init Parity XX% Please Wait â åæåãéå§ãããŸãããã£ã¹ã¯å®¹éã«ãã£ãŠç°ãªããŸããã æ°æéâŒåæ°æéããããŸãã LG=0 Initialize Completed â ESC ããŒãæŒããŸãã A12F-G2221 Ready ããã§ Quick Logical Drive Install ã¯å®äºã§ãã â èšå®ãããŒâ¡ ïŒããã¥ã¢ã«ã§èšå®ããå ŽåãïŒ ïŒãã¡ãŒã ãŠãšã¢ã®ããŒãžã§ã³ã«ãã衚瀺ãç°ãªãå ŽåããããŸããïŒ A12F-G2221 No Host LUN â ENT ããŒãæŒããŸãã Press 2 seconds for Main Menu â ENT ããŒãé·æŒãããŸãã Quick Logical Drive Install â View and Edit Logical Drives ââ â LG=0 Not Defined ? â TDRV=X Create LG Level=RAID5 ? â RAID5 Selected To select drives â SLOT=3 XXXXMB ïŒLG=0 SL SERGATE â âŒããŒãæŒããŸãã ENT ããŒãæŒããŸãã ENT ããŒãïŒç§çšæŒããŸãã âœâ³ã§èšå®ãã RAID ã¬ãã«ãéžæããENT ããŒã 2 ç§æŒããŸãã ïŒTDRVïŒTotal DrivesïŒ ENT ããŒãæŒããŸãã âŒâ²ã§äœ¿çšå¯èœãª Disk ã®æ å ±ãé æ¬¡ç¢ºèªããŸãã RAID ãæ§æãã Disk ã ENT ããŒã§éžæããŸãã ïŒéžæãã Disk ã«ã¯ïŒã衚瀺ïŒã¹ãã¢ã«èšå®ãã Disk ã¯ããã§ã¯éžæããŸããã æ§ç¯ãã Disk ãé æ¬¡éžæããŠãããENT ããŒãïŒç§çšæŒããŸãã 44/57 A12F-G2221 åæ±èª¬ææž ããã§ Logical Drive ã®ãã©ã¡ãŒã¿ïŒãã©ã€ãã®ãµã€ãºå€æŽãã¹ãã¢ãã©ã€ãçïŒã®èšå®ãè¡ããŸãã Change Logical Drive Parameter ? â ENT ããŒãïŒç§çšæŒããŸãã Maximum Drive Capacity . . â éåžžã¯ãã©ã€ããµã€ãºã®å€æŽã¯ããªãã®ã§ãâŒããŒã 1 åæŒããŸãã Spare Drive Assignments . . â SLOT=1 XXXXMB ïŒLG=0 SL SEAGATE â Create Logical Drive â Init Parity XX% Please Wait â ã¹ãã¢ãã©ã€ããèšå®ããå Žåã¯ãENT ããŒãæŒããŸãã ã¹ãã¢ãã©ã€ããèšå®ããªãå Žåã¯ãâŒããŒãæŒããŸãã 䜿çšå¯èœãª Disk ãâœâ³ããŒã§é 次確èªãã ã¹ãã¢ãã©ã€ãã«å²ãåœãŠã Disk ã ENT ããŒã§éžæããŸãã ïŒéžæãã Disk ã«ã¯ïŒãè¡šç€ºïŒ ENT ããŒãïŒç§çšæŒããŸãã ESC ããŒãæŒããäžã€åã®ã¡ãã¥ãŒã«æ»ããŸãã âœâ³ããŒã§ Create Logical Drive ãéžã³ã ENT ããŒãïŒç§çšæŒããŸãã åæåãéå§ãããŸãããã£ã¹ã¯å®¹éã«ãã£ãŠç°ãªããŸããã æ°æéâŒåæ°æéããããŸãã LG=0 Initialize Completed â ESC ããŒãæ°åæŒããŸãã A12F-G2221 No Host LUN ãã¹ãã®èšå®ãè¡ã£ãŠããªãããããNo Host LUNããšè¡šç€ºãããŠããŸãã 45/57 A12F-G2221 åæ±èª¬ææž 7.6.3 ãã¹ãã®èšå® äžèšã¯æãã·ã³ãã«ãªäŸã§ãã äžã€ã®ããžã«ã«ãã©ã€ããäžã€ã®ãã¹ãã«å²åœãŠãŠããŸãã è©³çŽ°ã¯æ·»ä» CD-ROM ã® Generic ManualïŒGMN.x.xx.pdfïŒ è±æçŽ 400 ããŒãžïŒãåç §é¡ããŸãã A12F-G2221 No Host LUN â Press 2 seconds for Main Menu â Quick Logical Drive Install â â View and Edit Host Luns ââ â CH0 ID=000 . . â Map To Logical Drive ? â CH0 ID112 LIN0 Not Mapped . . â åæç»é¢ ENT ããŒãæŒããŸãã ENT ããŒãé·æŒãããŸãã âŒããŒãïŒåæŒããŸãã ENT ããŒãæŒããŸãã ENT ããŒãæŒããŸãã ENT ããŒãïŒç§çšæŒããŸãã ENT ããŒãæŒããŸãã Map Host LUN ? â LG=0 RAID5 DRV=12 1501GB SB=0 â LG=0 PART=0 1537338MB â Map Host LUN ? . . â CH0 ID112 LUN0 Map to LG0 PRT0 ? â ENT ããŒãïŒç§çšæŒããŸãã ENT ããŒãïŒç§çšæŒããŸãã ENT ããŒãæŒããŸãã ENT ããŒãæŒããŸãã ENT ããŒãïŒç§çšæŒãã確å®ãããŸãã A12F-G2221 Ready äžèšã®ãã¹ãèšå®ã«ãããåæç»é¢ã¯ ãNo Host LUNããããReadyãã«å€ãããŸããã 46/57 A12F-G2221 åæ±èª¬ææž 8. 宿çãªã¡ã³ããã³ã¹ 8.1 Task Scheduler æ©èœ 8.1.1 Task Scheduler ã®æŠèŠ é垞䜿çšãããªãé åã«ãããŠãã£ã¹ã¯é害ãé²è¡ããŠããå ŽåãïŒå°ä»¥äžã®ãã£ã¹ã¯ãèªã¿æžãã§ããªããªãå¯èœ æ§ããããŸãã Task Scheduler æ©èœã䜿çšããŠå®æçã« Media Scan ãè¡ãããšã«ããããã£ã¹ã¯éå®³ãæ€åºããè€æ°å°ã®ãã£ã¹ã¯é 害ã®é²è¡ãäºåã«é²ãããšãã§ããŸãã Task Scheduler æ©èœã¯ãMedia Scan ãæå®ããæéããå§ãããã宿çãªééãæå®ããŠäžå®ééã§ç¹°ãè¿ãã ãããäºãå¯èœã«ããŸãããã®æ©èœã¯ãåå¥ã®ãã©ã€ããããã¯ã©ã¹ãã¹ãŠã®ãã©ã€ããæå®ãããã®è«çãã©ã€ãã®ã ã¹ãŠã®ã¡ã³ããŒãã©ã€ãããŸãã¯ããã¹ãŠã®è«çãã©ã€ãã®ãã¹ãŠã®ã¡ã³ããŒãã©ã€ãäžã§äœåããããšãã§ããŸãã ãŠãŒã¶ãŒã€ã³ã¿ãŒãã§ã€ã¹ã¯ãRS232C terminal menu ã§ãã Task Scheduler ã䜿ãã«ã¯ View and Edit Logical Drives ã¡ãã¥ãŒãéžæããŠãã©ã€ãã®ãªã¹ãã衚瀺ããåŸãMedia Scan ããããã©ã€ããéžã³[ENTER]ãæŒã[Media Scan]ãéžæããŠãã ããã âTask Schedulerâãéžã³[ENTER]ãæŒããŠãã ããã 8.1.2 Task Schedule ã®æ°èŠäœæ äºåã«ã¹ã±ãžã¥ãŒã«ãèšå®ãããŠããªãå Žåã¯äžèšã®ãããªã¡ãã»ãŒãžã衚瀺ãããŸãã âYesâãéžæããŠãæ°èŠäœæãè¡ã£ãŠãã ããã 47/57 A12F-G2221 åæ±èª¬ææž 8.1.3 Task Schedule ã®è¿œå ïŒåé€ æ¢åã®ã¹ã±ãžã¥ãŒã«ã®äžã§[ENTER]ãæŒããšãã¹ã±ãžã¥ãŒã«ã®æ å ±ã確èªã§ããããæ°ããã¹ã±ãžã¥ãŒã«ãäœæãã ããäœæãããã¹ã±ãžã¥ãŒã«ãåé€ããããšãã§ããŸãã 8.1.4 Task Scheduler ã®ãªãã·ã§ã³ ã¹ã±ãžã¥ãŒã«ãèšå®ããããã«ã以äžã®ãªãã·ã§ã³ããããŸãã Execute on Controller Initialization ãã®ãªãã·ã§ã³ã§ã¯ RAID ã·ã¹ãã ããªã»ãããããæãããã¯é»æºããããæãèªåçã« Media Scan ããããã©ã ããèšå®ããŸãã 8.1.5 Start Time and Date âéå§æ¥æã®èšå®â æéãšæ¥ä»ã®èšå®ãããŸãã以äžã®é çªã§å ¥åããŠãã ããã ïŒæïŒæ¥ïŒæïŒåïŒå¹Ž(西æŠ) 48/57 A12F-G2221 åæ±èª¬ææž 8.1.6 Execution Period âã¡ãã£ã¢ã¹ãã£ã³ãå®è¡ããééâ ã¹ã±ãžã¥ãŒã©ãŒã¯ Media Scan ãè¡ãæ¥ãšæéãèšé²ããŠããŸãã以äžã®é ç®ããã²ãšã€éžãã§ãã ããã ïŒåã ã Media Scan ããããªããâExecution Onceâãéžãã§ãã ããã 宿çã« Media Scan ããå Žåã«ã¯ãæå®ãããâéå§æéâã«å®è¡ããããã®åŸãèšå®ãããæéééã§ Media Scan ãå®è¡ããŸããæééé㯠1 ç§ããæ°é±éãŸã§éžæå¯èœã§ãã 8.1.7 Media Scan Mode âã¡ãã£ã¢ã¹ãã£ã³ã®ã¢ãŒãèšå®â ïŒã€ä»¥äžã®è«çãã©ã€ããå«ãã¡ã³ããã³ã¹ãããå Žåãé£ç¶ããé ã«ãåæã«ãããã¯å¥ã ã« Scan ããããšãã§ã ãŸãã 8.1.8 Media Scan Priority âã¡ãã£ã¢ã¹ãã£ã³ã®ãã©ã€ãªãªãã£ã®èšå®â Media Scan Priority ã§ã¯ Schedule Task ãå®è¡ããããã«ã©ãã ããªãœãŒã¹ã䜿ããæ±ºããŸããâLowâãéžæãããš Array Performance ãäžãã代ããã« Media Scan ãå®äºãããŸã§ã«æéãããããŸããããé«ã Priority ãéžæãã ãš Array Performance ãç ç²ã«ããŠããé«ã Media Scan ãå¯èœã«ããŸãã 49/57 A12F-G2221 åæ±èª¬ææž 8.1.9 Select Logical Drives âã¡ãã£ã¢ã¹ãã£ã³ãè¡ãè«çãã©ã€ãã®éžæâ ãµãã¡ãã¥ãŒã衚瀺ããããã« âSelect Logical Drivesâã®äžã§[ENTER]ãæŒããŠãã ããããã¹ãŠã®è«çãã©ã€ãã éžæããå Žåã¯âAll Logical Drivesâã®äžã§ãïŒã€ä»¥äžã®è«çãã©ã€ããéžæããå Žåã¯âTo Select Logical Drivesâã® äžã§[ENTER]ãæŒããŠãã ããã è«çãã©ã€ãã«ã«ãŒãœã«ããŒãåãããæ¬¡ã«[ENTER]ãæŒãããšã§ãã¢ã¹ã¿ãªã¹ã¯(â)ããŒã¯ãã€ããããšãã§ããŸãã éžæããããã©ã€ãã«ã¯ã¢ã¹ã¿ãªã¹ã¯(â)ããŒã¯ãã€ããŸãããã©ã€ãã®éžæãå€ãã«ã¯ãå€ããã©ã€ãã«ã«ãŒãœã«ã㌠ãåãã[ENTER]ãããäžåºŠæŒããšã¢ã¹ã¿ãªã¹ã¯(â)ããŒã¯ãæ¶ããŸããè€æ°ã®ãã©ã€ããéžæãããšããåæ§ã§ãã ãã©ã€ãã®éžæãçµãã£ããã[ESC]ãæŒããŠãã ããã 8.1.10 Confirming the Creation of a Task Schedule âèšå®ã®ç¢ºèªâ Scheduler ã®èšå®ãçµäºãããã確èªã®ã¡ãã»ãŒãžã衚瀺ããããã«[ESC]ãæŒããŠãã ããã èšå®ãçµãâYesâãéžæããåã«ãã¹ãŠã®æ å ±ãããäžåºŠç¢ºèªããŠãã ããã 50/57 A12F-G2221 åæ±èª¬ææž 9. ä¿å® å®åžžçã«ã·ã¹ãã ãã¢ãã¿ãŒãã¡ã³ããã³ã¹ããäºã«ãããã·ã¹ãã ã®ããŠã³ã¿ã€ã ãæå°ã«ããäºãã§ããŸãã æ¬æ©ã®äž»èŠæ§æãŠãããã¯äžèšã®ãŠãããã«ã¢ãžã¥ãŒã«åãããŠããããªã³ã©ã€ã³ãããã¹ã¯ãããå¯èœã§ãã ãã ãããããã¹ã¯ããäžã¯ãäžãäžã®é害ãé²ãããããã¹ãã¢ã¯ã»ã¹ã¯åºæ¥ãéãæ¢ããäºããå§ãããŸãã 1 2 3 äž»ãªã¢ãžã¥ãŒã« ã³ã³ãããŒã©ã¢ãžã¥ãŒã« PSUïŒé»æºãŠãããïŒ FAN ãŠããã 4 5 6 ããŒããã£ã¹ã¯ ããŒããã£ã¹ã¯ãã¬ã€ BBUïŒããããªãŒããã¯ã¢ãããŠãããïŒ ãããã¹ã¯ããã®å¯åŠ å¯èœ å¯èœ å¯èœ å¯èœ å¯èœ å¯èœ 泚æ ã»äº€æçšã¢ãžã¥ãŒã«ãæå ã«æºåã§ãããŸã§é害ã¢ãžã¥ãŒã«ãåãå€ããªãã§ãã ããã å éšã®ãšã¢ãŒãããŒ ã«æªåœ±é¿ãäžããã·ã¹ãã ã®ãã¡ãŒãžãåŒãèµ·ããå ŽåããããŸãã ã»é»æºãèœãšããšã·ã¹ãã ã®ã€ãã³ããã°ãæ¶å»ãããŸãã é害察çã®ããã«é»æºãèœãšãå Žåã¯ã€ãã³ããã° ã®ã¡ã¢ããšã£ãŠãããããšããå§ãããŸãã 9.1 é害ã®ç¢ºèª æ¬æ©ã«ã¯ã·ã¹ãã ç¶æ ãç£èŠããé害ãèµ·ããæã«ãã¢ã©ãŒããåºããé©åãªã¢ã¯ã·ã§ã³ããšããããã«ãè±å¯ãªã¢ãã¿ ãŒæ©èœãè£ åããŠããŸãã é害ãèµ·ããå Žå㯠第ïŒç« æ¬æ©ã®ã¢ãã¿ãŒæ©èœ ãåç §ããé害å 容ã®ç¹å®ãè¡ ããã·ã¹ãã ãã³ããŒã«é£çµ¡ããŠãã ããã ãªãé害å 容ã¯ã€ãã³ããã°ãšããŠæç³»åçã«æ¬æ©ã®ã¡ã¢ãªãŒã«èšé²ã ããŸããã黿ºãèœãšããšæ¶å»ãããŠããŸããŸãã 黿ºãèœãšãåã«ã€ãã³ããã°ã®å 容ãã¡ã¢ããŠãã ããã 9.2 黿ºãŠãããïŒPSUïŒã®ä¿å® 9.2.1 PSU ä¿å®ã®æ³šæäºé â æ¬æ©ã®é»æºã¯ïŒã€ã® 46ïŒW ãããã¹ã¯ãããªãã³ãã³ã PSU ã§æ§æããŸãã â¡ ã·ã³ã°ã«é»æºã§ã·ã¹ãã ã®åäœã¯å¯èœã§ããã黿ºé害æã®å¯Ÿå¿çšãšããŠã®ã¿äœ¿çšããŸãã æ°ããªäº€æçš PSU ãå°çãããŸã§ã¯ãé害ãèµ·ãã PSU ãã¯ãããªãã§ãã ããã PSU ãåãå€ããç¶æ ã§ã¯ãšã¢ãŒãã ãŒãæªåãããããé·æééçšãããšã·ã¹ãã ã«é倧ãªãã¡ãŒãžãåŒãèµ·ããå ŽåããããŸãã â¢ é»æºé害æã¯ãèµ€ LED ãç¹ç¯ããã¢ã©ãŒã ã鳎ããLCD ãŸãã¯ã¿ãŒããã«ã«ã€ãã³ããã¬ããŒãããŸãã 9.2.2 PSU ã®äº€æ Step1 é害 PSU ã®é»æºã¹ã€ãããåãããã® PSU ãã AC ã³ãŒããæããŸãã Step2 PSU å³åŽã®åºå®ããžãïŒãã©ã€ããŒã§ã¯ãã㟠ãã 51/57 A12F-G2221 åæ±èª¬ææž Step3 PSU ã¬ããŒãæåã«åŒããªãããPSU ã¢ãžã¥ãŒ ã«ãåŒãæããŸãã Step4 FAN ã¢ãžã¥ãŒã«ãåŒãæããŸãã Step5 æ°ãã PSU ã¢ãžã¥ãŒã«ã«ãå çšåŒãæãã FAN ã¢ãžã¥ãŒã«ãå ¥ããŸãã 9.3 BBU ã®ä¿å® 9.3.1 BBU ä¿å®ã®æ³šæäºé æ¬æ©èé¢ã®ã³ã³ãããŒã©æšªã« BBU ãè£ çãããŠããŸãã BBU ã«é害ãçºçããå ŽåããŠãããèé¢ã® LED ãèµ€ç¹ç¯ãã¢ã©ãŒã ã鳎ããLCD ãŸãã¯ã¿ãŒããã«ã«ã€ãã³ãã㬠ããŒãããŸãã BBU ã«é害ãçºçããå Žåãã§ããã ãæ©ã亀æããŠãã ããã ãã ãæ°ã㪠BBU ãå°çãããŸã§ã¯ãåãå€ã㪠ãã§äžããã 9.3.2 BBU ã®äº€æ Step1 2 ã€ã®ã€ãŸã¿ããžãã¯ãã㊠BBU ãåŒãåºããŸãã Step2 æ°ãã BBU ãè£ çãã ã€ãŸã¿ããžã 2 ã¶æãããŸãã 52/57 A12F-G2221 åæ±èª¬ææž 9.4 FAN ãŠãããã®ä¿å® 9.4.1 FAN ãŠãããä¿å®ã®æ³šæäºé æ¬æ©èé¢ã®å·Šå³ã« 2 åã®ãããã¹ã¯ãããªãã³ãã³ã FAN ãŠããããè£ åããã·ã¹ãã ã®ã¯ãŒãªã³ã°ãè¡ã£ãŠããŸãã FAN ãŠãããã«é害ãçºçããå ŽåããŠãããèé¢ã® LED ãèµ€ç¹ç¯ãã¢ã©ãŒã ã鳎ããLCD ãŸãã¯ã¿ãŒããã«ã«ã€ã ã³ããã¬ããŒãããŸãã FAN ãŠãããã«é害ãçºçããå Žåãã§ããã ãæ©ã亀æããŠãã ããã ãã ãæ°ã㪠FAN ãŠããããå°çãã㟠ã§ã¯ãåãå€ããªãã§äžããã åãå€ããšæ®ã 2 åã®ã¯ãŒãªã³ã° FAN ã®ãšã¢ãŒãããŒã«æªåœ±é¿ãäžããŸãã 9.4.2 FAN ãŠãããã®äº€æ FAN ãŠãããèé¢ã®äºã€ã®é»ãã©ããã§ããã¯ãããŠããŸãã åãå€ãæã¯äºã€ã®é»ãã©ãããå³ã®ããå åŽã«æŒããªããããŠãããäžéšã®ãã³ãã«ãåŒããŠéãã«ã¯ãããŸãã æ°ãããŠããããã¹ãããã«æ¿å ¥ãéãã«ã©ãããããã¯ãããŸã§æŒãå ¥ããŸãã 53/57 A12F-G2221 åæ±èª¬ææž 9.5 HDD ãš HDD ãã¬ã€ã®ä¿å® 9.5.1 HDD ã®ç¶æ³ç¢ºèª ãã©ã€ããã¬ã€ã®LED衚瀺ã§é害HDDã®çªå·ã確èªããLCDããã«ã®ã€ãã³ããã°ã§è©³çްæ å ±ãã¡ã¢ããŸãã 〠ãã³ããã°ã®èŠæ¹ã¯ç¬¬ïŒç« ãåç §ããŠãã ããã LED Name Drive Busy Color éè² Power Status ç·è² èµ€è² Status ONïŒ ãã©ã€ããã ReadïŒWrite äž OFFïŒ ã¢ã¯ã»ã¹ããŠããªã ONïŒ ãã©ã€ã Ready ONïŒ ãã©ã€ãé害ããäœããã®é害ãçºç ã» LCD ããã«ããäžèšã®ããã«åãã©ã€ãã®ç¶æ³ç¢ºèªãã§ããŸã A12F-G2221 Ready â ENT ããŒãïŒç§çšé·æŒãããŸãã Quick Logical Drive Install â âŒããŒãïŒåæŒããŸãã View and Edit SCSI Drives ââ â ENT ããŒãæŒããŸãã SLOT=3 00****MB LG=0 LN SEAGATE âã€ã³ã¹ããŒã«ãããŠãã HDD ã®ç¶æ ã瀺ããŸãã â³âœããŒã§ãå šãŠã®ãã©ã€ãã®ã¹ããŒã¿ã¹ã確èªããŠäžããã ïŒLCD è¡šç€ºã®æå³ïŒ SLOT=3 㯠Drive Slot No.ããããŸãã ãLNããšè¡šç€ºãããŠããã®ã¯ããžã«ã«ãã©ã€ãã®ã¡ã³ããŒã§ãã ãSBã(Stand By)ãšè¡šç€ºãããã°ãã¹ãã¢ãã©ã€ããå·®ããŸãã ãã以å€ã«ã¯ãBDã(Rebuilding),ãNew DRVãããABSENTããšãã£ã衚瀺ããããŸãã 確èªãçµãã£ãã ESC ããŒãæ°åæŒãåæç»é¢ã«æ»ããŸãã 54/57 A12F-G2221 åæ±èª¬ææž 9.5.2 HDD ã®äº€æäœæ¥ ïŒHDD 亀ææã®æ³šæäºé ïŒ ã» äº€æãã HDD ã®å®¹éã¯çŸåšäœ¿çšäžã® HDD ã®å®¹éãšçãããã倧ãããªããã°ãªããŸããã ã» åãã¡ãŒã«ã®åäžå ¬ç§°å®¹éã® HDD ã§ãæå€§ LBA ã®å€ã埮åŠã«ç°ãªãå ŽåããããŸãã®ã§æ³šæããŠãã ããã ã» HDD ã®åä»ãããžã¯å¿ ãæ·»ä»åã䜿çšããŠãã ãããé·ãããžã䜿çšãããšããã©ã€ãã®åè·¯éšåã«ãã¡ãŒãžã äžããŸãã ã» HDD ã¯è¡æããã³é黿°ã«å¯ŸããŠéåžžã«ããªã±ãŒãã§ãã ã·ã§ãã¯ãäžããªãããååæ³šæããHDD ã«è§Šãã åã«äœããã®æ¹æ³ã§äººäœã®é黿°ãæŸé»ããŠãã ããã ã» ç Žæããã£ãå ŽåïŒã³ãã¯ã¿æ¬ ããã©ãã«ã¯ããçïŒã亀æã«å¿ããããªãå ŽåããããŸãã®ã§ãæ éã«ãåæ±ã ãã ããã ã» RAID è£ çœ®æ¬äœã®é»æºã¯åããã«è¡ãäºãã§ããŸãããäžäžã®ããŒã¿æ¶å€±ãé²ããããäºåã«ããŒã¿ã®ãã«ãã ã¯ã¢ãããæ¡ã£ãŠããäºãåŒ·ãæšå¥šããŸãã â RAID ãµãã·ã¹ãã ã®ãã©ã€ããã€ïŒSlot çªå·ïŒã¯ 1âŒ12 ãŸã§äžå³ã®ããã«é 眮ãããŠããŸãã I â¡ é害ãã©ã€ããããã«ã®å·Šå³ãã³ãã«ã®åŸãã«ããå Žåããã©ã€ããã¬ã€ãéããåã«ãã®ãã³ãã«ãéããŸãã ⢠æ éããŠãã HDD ãã¬ã€ã®ã¯ãªãããäžéšã«æŒãäžãããšãã¬ã€ã®èãéããŸãã®ã§éãã«ãã¬ã€ãåŒãæããŸãã HDD ã¯åŽé¢ïŒç®æã®ã€ã³ãããžã§åºå®ãããŠããŸãã®ã§ããã©ã€ããŒã§ããžãã¯ãããäžè¯ã® HDD ãåãå€ã ãŸãã 55/57 A12F-G2221 åæ±èª¬ææž ⣠HDD ã®ã³ãã¯ã¿ããã¬ã€ã®åŸç«¯ã«äœçœ®ããããã«æ·»ä»ã®ç¿ã€ã³ãããžïŒåã§ HDD ããã¬ã€ã«åºå®ããŸãã å¿ ãæ·» ä»ãŸãã¯ãåå€ããããžã䜿çšããŸãã é·ãããžã¯ãã©ã€ãã®åè·¯ãç ŽæããããšããããŸãã †HDD ä»ããã¬ã€ãæ éã«ã¹ãããã«æ¿å ¥ãæ¢ãŸããŸã§æŒããŸãã ãã¬ã€ã®èã®ã¯ãªãããããã¯ããŸãã ⥠ãã¬ã€ã®éè² LED ãç¹ç¯ã Ready ã«ãªãããšã確èªããŸãã 9.4.3 HDD 亀æåŸã®ãã§ã㯠äžèšã¯äº€æãã HDD ãã¹ãã¢ãã©ã€ããšããŠèªèãããäŸã§ãã A12F-G2221 Ready â åæç»é¢ ENT ããŒãïŒç§çšé·æŒãããŸãã Quick Logical Drive Install â âŒããŒãïŒåæŒããŸãã View and Edit SCSI Drives ââ â ENT ããŒãæŒããŸãã SLOT=3 BAD DRV â äžæŠ Disk ãæãããããBAD ãšè¡šç€ºãããŠããŸãã ENT ããŒãïŒåæŒããŸãã 56/57 A12F-G2221 åæ±èª¬ææž Scan new SCSI Drive .. â å ¥ãæ¿ãã HDD ãèªèããããããã¹ãã£ã³ããããŸãã ENT ããŒãïŒåæŒããŸãã Scan Channel=2 ? â âŒããŒãæŒããŸããïŒChannel=3 ã«å€æŽããããïŒ Scan Channel=3 ? â Scan Channel=3 ID=00 ïŒ â SLOT=3 00****MB NEW DRV SEAGATE â View and Edit SCSI Drives ââ â ENT ããŒãïŒç§çšæŒããŸãã ENT ããŒãïŒç§çšæŒããŸãã ESC ããŒãæŒããäžæŠäžã®éå±€ã«æ»ããŸãã ENT ããŒãæŒããŸãã C=3 I=0 00****MB NEW DRV SEAGATE â ENT ããŒãæŒããŸãã View Drive Information â âŒããŒãæŒããŸãã Add Local Spare Drive . . â ENT ããŒãæŒããŸãã *LG0 RAID5 DRV=7 ******MB GD SB=0 â ENT ããŒãïŒç§çšæŒããŸãã Add Local Spare Drive Successful â ESC ããŒãæŒããŸãã SLOT=3 00****MB LG=0 SB SEAGATE â âãLGããããžã«ã«ãã©ã€ã ãSBããã¹ãã¢ãã©ã€ãã«èšå®ãããããšãæå³ããŠããŸãã ESC ããŒãæ°åæŒããåæç»é¢ã«æ»ããŸãã A12F-G2221 Ready åæç»é¢ 以äžã§ãHDD 亀æäœæ¥ã¯çµäºã§ãã ä»¥äž 57/57