6-2. Reference Point Setting 1 2 Check that the R.ADJ switch is set to OFF. When setting direction where reference point is located 4 3 R.ADJ DIR 1 2 3 4 Setting procedure In the interpolator, the positional relationship between the reference point signals and scale signals must be set in order to output a reference point in synchronization with the scale signals. After mounting the scale and reference point sensor, be sure to always make the settings below. Check that it is OFF Move the scale in the opposite direction from where the reference point will be located, and then pass through the reference point. After passing through the reference point, check that the REF lamp is turned off. REF REF lamp is off Opposite direction from reference point location MD20B (E) 19