02 04/12 ED 200-D Operating instructions To commission the operator, unlatch the emergency off push- 4.2.2 Opposite hinge-side button located next to the door. Then switch on the main If there is an obstruction in the detection range of the switch (located at the side of the operator). IRS sensor - the door in its closing cycle reverses, or 1. Programme switch - if already opened, the door remains at that positiThe following programme switch settings are possible: on. Programme switch integrated in operator: Once the detection range is clear, the operator resuAutomatic - OFF - Permanent open mes normal operation. External programme switch: 5. Care and maintenance OFF - Exit only - Permanent open - Automatic The system must be inspected by a properly qualified „OFF“ setting service engineer prior to initially coming into service The operator is switched off and the door can only be manu- and thereafter at least once a year, or more frequently ally operated. according to requirements (in compliance with German guidelines for power-operated doors, windows „AUTOMATIC“ mode and gates, ZH 1/494, April 1989 edition and or local The door opens on receipt of a signal from an activator (e.g. regulations). internal or external radar detector), and closes automatically Further information and regulations governing the emon expiry of the preset hold-open time. ployment of the ED 200 in relation to fire and smoke rated doors: „EXIT ONLY“ mode The door can only be activated from one side (one-way func- Instruction sheet relating to the use and applition e.g. at the end of business hours). The door closes again cation for hold open device systems.1) automatically on expiry of the preset hold-open time. Guidelines for hold open systems published by the Institute for Building Technology Berlin.1) „PERMANENT OPEN“ mode Relevant local regulations. The door opens and remains in this position until another Customers are recommended to take out a service mode is selected. contract with DORMA covering maintenance of the operator. 2. Starting up following a power failure ☞ The operator starts up automatically following a power failure, and resumes operation in the preset programme switch mode. 3. Emergency opening in the event of a power failure Door can be manually operated . 4. Safety functions 4.1 Integrated safety device The operator must be set by the service engineer in accordance with German guidelines for power-operated windows, doors and gates (ZH 1/494) or equivalent local regulations; i.e. the force at the main closing edge of the door must be limited to max. 150 N. When cleaning the door, ensure that the operator has been switched off. The door and operator can be cleaned with a damp cloth and standard commercial cleaning agents. 6.Troubleshooting If the door fails to close or open, first check the following points: - Mains power available? - Emergency off pushbutton unlatched? - Main switch ON? - Programme switch set to correct mode? - IRS sensor detection range free? - Door obstructed? - Door manually locked? If, having checked the above points, the fault remains, inform your local service engineer 4.2 Operating with IRS Sensors (Optional extra) 4.2.1 Hinge-side If there is an obstruction in the detection range of the IRS sensor - the door stops during the opening cycle, or - the door remains closed if it is already in the door-closed position. Once the detection range is clear, the operator resumes normal operation. Subject to change without notice WN 057020 45532 DORMA 1) These documents are only printed in German as they refer exclusively to the German market. DORMA GmbH + Co.KG www.dorma.com DORMA Platz 1 D-58256 Ennepetal Tel. +49 2333 793-0 Fax. +49 2333 793-4950 13