Download NOTE

Transcript
41
SI...
5.4 Strain channel generation
The values measured by the interrogator are the wavelengths of the signals
reflected by the sensors. When a strain at the optical strain gage causes the
wavelength to change, this wavelength variation is proportional to the strain. So
to obtain strain values, the wavelengths have to be converted to strains. The
gage factor specified on the sensor packaging acts as the proportionality factor.
Make sure that all the expected channels (fiber Bragg gratings) are detected
before you create the calculations: If you reconfigure the channels, you have to
run a new scan and all the calculations will be lost.
5.4.1 Specifying calculation without temperature compensation
NOTE
Temperature effects can only be ignored if there is a quasi-constant temperature
of object and fiber or optical strain gage. Compensation usually has to take
place, as the effects caused by temperature variations (variation in the grating
wavelength when the fiber is heated) are major compared to a resistive strain
gage and would heavily distort the result.
In the “Channel settings” window, choose the “Optical sensors −> Create strain
channel” menu items. This will open the “Computation channels” dialog box and
show the “Optical sensors” tab (Fig. 5.14).
Fig. 5.14
A2220-2.1 en/de
HBM