5. Installation 5.1 Fitting the micro filter to the dryer In order that the adsorption media can be protected from dirty compressed air, a micro filter type MS6-LFM must be fitted to the inlet of the dryer. When the dryer is supplied from the factory the three inlet possibilities are on the left-hand side of the dryer (see arrows). If the inlet on the righthand side is required, then the multiport manifold in the cover of the dryer must be turned (see chapter 5.4). 1. Select inlet opening. If necessary, remove the blanking plug and fit it onto the unused inlet. 2. Place a greased O-ring 2 into the groove of inlet 1. 3. Fasten the module connector plate 3 with a hollow screw 4 of width A/F 10 (with PDAD-…y) or A/F 14 (with PDAD-…½) to the inlet. The tightening torque is max. 15 Nm (with PDAD-…y) or max. 18 Nm (with PDAD-…½). The module connector plate 3 must be turned 90° if the dryer is to be installed in a horizontal position. 1 2 3 3 4 Festo PDAD 1410d English | 49