Download Mod: DFN200/33A
Transcript
E081101X 14/11/08 rotation change. Press the emergency stop button with the hand: the chest lifts and the roller sense of rotation change. - Press the anti – panic bar with a knee: the chest immediately goes away from the roller even if the machine is not electrically supplied. If no one of the above operation give a good result, be sure that the anti-panic bar is pressed and, using the plastic key given with the ironer document, open the side door. Open the door rotating it on the base. for a problem solution. The activation of one of the following alarms is signalled also by a buzzer beep. HAND SAFE BAR Something is obstruct the ironing surface and the hand safe bar was pressed: the ironer stay in OFF position until the hand safe bar come back to its original position. - OFF SALVAMANI If the alarm is given and the ironing surface is free, then check the hand safe bar end switch correct working and the relative electric connection. OVERTEMPERATURE Roller temperature is above the safety limit and the display shows: 230°C 5mt/min OVERHEATING In case this alarm is verified the chest automatically lifts and the suction is activated (if provided). The alarm disappear when the temperature come back to normal values. While the alarm is activated, the roller cannot be started up. Call your service to check the damage. TEMPERATURE PROBE FAIL The temperature probe is damaged and the display shows: To take away the chest from the roller, pull up the bracket (the same in the above picture) so that the chest goes back and frees the limb, or the cloth, blocked into the ironer. ATTENTION! The laundry manager must know the above procedures, must explain them to the personnel and must be sure that the ironer users well understood the risks of the ironer and emergency procedure. Periodically, the user must be tested about these procedures and its comprehension. - - - °C 5mt/min TEMPERATURE PROBE FAIL Same procedure saw for the above alarm. Call the service. MOTOR THERMAL A motor thermal alarm is given when an inverter fail occurs. The display shows: 24. WHAT TO DO IN CASE OF ENERGY FAIL In case of black out one or more clothes may stay blocked between the roller and the ironer and may burn. In this case press the anti-panic bar with the knee and keep it press until the chest goes away from the roller. When the anti-panic bar is pressed the chest automatically goes away from the roller and free the cloth avoiding its burning and the roller cover burning. 140 °C 5mt/min MOTOR THERMAL The machine activate the cool down and start the suction (if provided). Once the cool down temperature is reached, the ironer stops: the alarm is still displayed, it can be reset switching off the machine. Call service. WDT CHEST If the stand by position of the chest is not reached within 10’ from when the instruction is given, the machine stop and the display shows: 25. NOT CORRECT WORKING SIGNAL In case the ironer is not working correctly, the microprocessor gives a complete diagnosis. The list of displayed alarms is given below, anyway we suggest to contact the service asking 27