Download T4000 Direct Multicode
Transcript
Chapter 6 Commissioning and operation Operating Instructions T4000 Direct Multicode 6.6 System state table Tab. 5: System state table x Off 15 Hz (10 s) Self-test after application of the supply of power Normal operation, guard closed Closed On 1) On 1,5 Hz Closed 1) Off (LED approx 2 s on /0,3 s off) Open Off 1 x Normal operation, guard open x Off Internal error x Off 2 x Input fault, e.g. no test pulse, illogical output state Closed Off 3 x Incorrect or defective actuator x Off 4 x Output fault, e.g. cross-circuit or loss of switching function x Off 5 x Internal error x Off x x Internal fault with malfunction on the guard Closed Error indication ERROR (red) Safety output OA and OB Normal operation State Actuator/ door position Self testing STATE (green) LED indicator Explanation of symbols: LED off LED illuminated 1) 164 Normal operation, protective device closed, actuator in limit area, e.g. adjusting door Normal operation, protective device closed, safety outputs from previous T4000 Direct switch are off LED flashing X Any Available as of date of manufacture 1037 (see 1.4 “Scope”) © SICK AG • Industrial Safety Systems • Germany • Subject to change without notice • 8012205/UC32/2010-11-15