Download INSTALLATION MANUAL
Transcript
1D_IM_4PW63277-1.book Page 1 Wednesday, June 23, 2010 3:14 PM ERLQ006BAV39 ERLQ007BAV39 ERLQ008BAV39 CONTENTS Outdoor unit for air to water heat pump Page Safety precautions ............................................................................. 1 Model................................................................................................. 3 Accessories ....................................................................................... 3 Installation guidelines ........................................................................ 3 SAFETY Meanings of DANGER, WARNING, CAUTION and NOTE symbols. DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING Installation procedure ........................................................................ 5 Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Mounting the outdoor unit .......................................................................... 5 Drain work.................................................................................................. 5 Flaring the pipe end ................................................................................... 5 Connecting the refrigerant piping to the outdoor unit................................. 6 Refrigerant piping work .............................................................................. 6 Purging air and checking gas leakage ....................................................... 6 Charging refrigerant ................................................................................... 7 Wiring......................................................................................................... 8 CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. NOTE Test run and final check................................................................... 10 Indicates situations that may result in equipment or property-damage accidents only. Trial operation and testing........................................................................ 10 Items to check.......................................................................................... 10 Pump down procedure............................................................................. 10 Forced cooling operation.......................................................................... 10 ■ Maintenance and servicing.............................................................. 11 Service precautions ................................................................................. 11 Service mode operation ........................................................................... 11 PRECAUTIONS The precautions listed here are divided into the following four types. They all cover very important topics, so be sure to follow them carefully. Precautions for selecting the location ........................................................ 3 Selecting a location in cold climates .......................................................... 4 Refrigerant piping specifications ................................................................ 4 Installing near a wall or obstacle................................................................ 4 Outdoor unit installation drawing................................................................ 5 Pump down operation...................................................................... 10 Installation manual After completing installation, test the unit to check for installation errors. Give the user adequate instructions concerning the use and cleaning of the unit as included in the operation manual of the indoor unit. Danger Disposal requirements..................................................................... 11 ■ Before touching electric terminal parts, turn off power switch. Unit specifications............................................................................ 11 ■ When service panels are removed, live parts can be easily touched by accident. Technical specifications ........................................................................... 11 Electrical specifications............................................................................ 11 READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE. IMPROPER INSTALLATION OR ATTACHMENT OF EQUIPMENT OR ACCESSORIES COULD RESULT IN ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE SPECIFICALLY DESIGNED FOR USE WITH THE EQUIPMENT AND HAVE THEM INSTALLED BY A PROFESSIONAL. Never leave the unit unattended during installation or servicing when the service panel is removed. ■ Warning ■ Ask your dealer or qualified personnel to carry out installation work. Do not install the machine by yourself. Improper installation may result in water leakage, electric shocks or fire. ■ Perform installation work in accordance with this installation manual. Improper installation may lead to water leakage, electric shocks or fire. ■ Consult your local dealer regarding what to do in case of refrigerant leakage. When the unit is to be installed in a small room, it is necessary to take proper measures so that the amount of any leaked refrigerant does not exceed the concentration limit in the event of a leakage. Otherwise, this may lead to an accident due to oxygen depletion. ■ Be sure to use only the specified accessories and parts for installation work. Failure to use the specified parts may result in water leakage, electric shocks, fire, or the unit falling. ■ Install the unit on a foundation that can withstand its weight. Insufficient strength may result in the fall of equipment and causing injury. ALL ACTIVITIES DESCRIBED IN THIS MANUAL SHALL BE CARRIED OUT BY A LICENSED TECHNICIAN. BE SURE TO WEAR ADEQUATE PERSONEL PROTECTION EQUIPMENT (PROTECTION GLOVES, SAFETY GLASSES, ...) WHEN PERFORMING INSTALLATION, MAINTENANCE OR SERVICE TO THE UNIT. IF UNSURE OF INSTALLATION PROCEDURES OR USE, ALWAYS CONTACT YOUR DAIKIN DEALER FOR ADVICE AND INFORMATION. The English text is the original instruction. Other languages are translations of the original instructions. ERLQ006~008BAV39 Outdoor unit for air to water heat pump 4PW63277-1 – 07.2010 Do not touch water pipes during and immediately after operation as the pipes may be hot. Your hand may suffer burns. To avoid injury, give the piping time to return to normal temperature or be sure to wear proper gloves. Installation manual 1