Download CHARGER U4
Transcript
5. Specification Input voltage: 220 – 240VAC, 50/60 Hz Input current: 0.7A rms maximum Battery drain current: 5mA maximum (with no input power) Cut off voltage: 14.4V or 14.7V nominal Charging current: 3.8A or 0.8A nominal Ripple 150mV maximum Battery type: 12V lead acid battery, 1.2Ah – 120 Ah Protection level: IP65 Audible noise: <50dB SPL (tested at 0.5m distance) 6. Safety Instructions Please read these instructions carefully before using the charger. [1] Use the device to charge a 12V, 1.2Ah – 120Ah – acid type rechargeable battery only. Do not use it to supply power to low voltage electrical system. Do not use it for any other purposes than the designated applications, as it may cause an explosion. WARNING! DO NOT ATTEMPT TO CHARGE A NONRECHARBEABLE BATTERY. (PRIMARY CELLS) [2] The Charger U4 (Model : 526-2044) is for indoor use only. [3] This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. 17