TÜV Rheinland Energie und Umwelt GmbH Air Pollution Control Report on performance testing of the Fidas® 200 S measuring system manufactured by PALAS GmbH for the components suspended particulate matter PM10 and PM2.5, Report no.: 936/21218896/A Page 23 of 476 Performance criterion Specification Test result Fulfilled Page 5.3.4 Linearity (lack of fit) The analytical function describing the relationship between the output signal and the value of the air quality characteristic shall be linear. Particulate measuring systems for PM10 shall be tested according to performance criterion 5.4.2 “Equivalency of the sampling system”. - 92 5.3.5 Sensitivity coeffi- The sensitivity coefficient of the Not applicable. cient of sample sample gas temperature at refgas pressure erence point shall not exceed the specifications of Table 2 of VDI Standard 4202, Sheet 1 (September 2010). - 93 5.3.6 Sensitivity coeffi- The sensitivity coefficient of the Not applicable. surrounding temperature at zecient of sample gas temperature ro and reference point shall not exceed the specifications of Table 2 of VDI Standard 4202, Sheet 1 (September 2010). - 94 yes 95 5.3.7 Sensitivity coefficient of surrounding temperature The sensitivity coefficient of the surrounding temperature at zero and reference point shall not exceed the specifications of Table 2 of VDI Standard 4202, Sheet 1 (September 2010). Particulate measuring systems for PM2.5 shall be tested according to performance criterion 5.4.10 “Calculation of expanded uncertainty between systems under test”. The ambient temperature range tested at the AMS installation site was 20 °C to +50 °C. Looking at the values that were output by the AMS, the maximum dependence of ambient temperature in the range of -20 °C to +50 °C at zero was -1.1 x 10-5 µg/m³ For PM: for PM2.5 and -1.1 x 10-5 µg/m³ for Zero point value for ∆Tu of PM10. 15 K between +5 °C and +20 At reference point, no deviations > °C or 20 K between +20 °C 5.0 % for PM2.5 and > 4.6 % for and +40 °C shall not exceed PM10 in relation to the default temB0. perature of 20 °C were observed. The measurement value in the range of B1 shall not exceed ± 5 % for ∆Tu of 15 K between +5 °C and +20 °C or for 20 K between +20 °C and +40 °C 1_3185580_2013_936_21218896A_EN.doc
Related documents
pdf-Dokument - ULB Bonn :: Amtliche Bekanntmachungen und
TÜV RHEINLAND ENERGIE UND UMWELT GMBH Report
Therapy Air iOn Bedienungsanleitung
Betriebsanleitung WS200-UMB WS300-UMB WS301
Handbuch - Fischer Barometer
Anleitung WSx-UMB ab Geräteversion 030 (DE)
Betriebsanleitung WS200-UMB WS300-UMB WS400
18473-A RG3 and RG3-M Manual German
Clima Sensor US - RTS Automation Vertriebsgesellschaft
Lufft WS600 Weather Station User Manual
Anleitung
Bedienungsanleitung LF8710 (pdf, 1,7MB, deutsch)