Download 2 - Automatismes Distribution

Transcript
Automatic repositioning
To carry out automatic repositioning without waiting for 3 minutes you may send
a (TA, TC, TAL or TD) command to the programmer. If a “TA” command is given
the positioning recovery is carried out in the opening direction.
No commands will be accepted during repositioning but the security devices will
cut in and block all movement if they go into alarm.
• To interrupt the repositioning manoeuvre and delay it for another 3 minutes,
press the “PROG” or “TB” button.
If the programmer blocks due to an encoder count error
, after a programmer reset
, when one of the motors has been released
or there is a
problem with one of the motors
the warning lights and indicator light will
flash simultaneously for 2 seconds and will then switch off for 10 seconds.
After the programmer has been in this condition for 3 minutes it will (after preflashing for 10 seconds) automatically move the gate, slowly, to the completely
closed position (2 times as in the programming procedure) in order to recover the
correct position. At this point the programmer will function normally.
DISPLAY MODE
Using the PROG button you can access the following functions in
sequence:
- memorising the status of the dip-switches;
- display the status of the command and safety devices;
- display the number of manoeuvres;
- access the "test" mode;
- set the limited opening distance;
- set the current sensor level;
- selecting the type of motor.
The status of the security devices TB, FTCI,
FTCS and CSP are always shown on the display.
PRESS PROG
Memorising the DIP-SWITCH settings
displaying the firmware version (e.g. “0”)
and
0 sec
The segments regarding the command status
(LED “ON” = command active) and safety status
(LED “ON” = safety device at rest) light up.
The number of manoeuvres appears on the
display. This number always remains visible until
you change the setting. Once 999999 has been
exceeded the lighting up of the decimal point on
the display equals 1 million + the six figure
number.
In the "test" mode (activated when the motor has
stopped) it is possible to check the status of the
command and safety devices. The warning lights
will activate once, each time a “TA-TC-TAL-TDTB-FTCI-FTCS-CSP” command is received. In
this mode you can activate serial line
communication using the external program,
connected to the CSER connection via cable.
While communication is active dashes will appear
on the display; after 5 seconds of inactivity you
will be moved back to the "test" mode. To return
to the normal mode press the button again “test”
will appear, then wait for 10 seconds.
0 sec
PRESS PROG
When the ("TA-TC-TD-TAL-TB-FTCI-FTCS, CSP")
inputs are activated the warning lights will light up.
5 sec
PRESS PROG
Connect the
programming device
(CSER) and activate it.
PRESS PROG
0 sec
APL = Setting the limited opening space:
SNS = Setting the current sensor:
1 = 1/3 of the distance of gate 1
2 = half the distance of gate 1
3 = 2/3 of the distance of gate 1
4 = the entire distance of gate 1
PRESS
PROG
Each time "PROG"
is pressed the
number increases
(from 1 to 4).
1 = motor consumption + 2 amp
2 = motor consumption + 3 amps
3 = motor consumption + 3,5 amps
0 sec
0 sec
0 sec
Each time "PROG"
is
pressed
the
number will increase
(from 1 to 3).
PRESS
PROG
PRESS
PROG
PRESS PROG
PRESS
PROG
0 sec
0 sec
10 s after the last modification you will
automatically exit the mode and the
selected values will be saved (eg. 3)
10 seconds after the last modification
you will be automatically moved out
of the mode and the selected values
will be saved (eg. 4)
PRESS
PROG
0 sec
Selecting the type of motor
BL1924 = Articulated operator arm
BL3924 = Articulated operator (integrated)
HL2524 = Underground operator
BL224E = Straight arm operator
PRESS PROG
PRESS
PROG
21