5.10 Alarm Messages
Alarms may be rearmed either automatically or manually.
The following Alarm Messages may appear on the screen:
Serious Error
Power Failure
System power failure.
The order of the three phases is inverted.
Automatically and immediately rearms when the problem is solved.
Serious Error
Thermal Motor
The thermal circuit is open. Failure in the thermal system.
Semi-automatically rearmed when the problem is solved and the
MODE key is pressed.
Serious Error
High Pressure
The high pressure switch indicates the circuit is open.
Pressure is too high.
Semi-automatically rearmed when the problem is solved and the
MODE key is pressed.
Serious Error
Low Pressure
The high pressure switch indicates the circuit is open.
Pressure is too low.
Semi-automatically rearmed when the problem is solved and the
MODE key is pressed.
Serious Error
Probe Failure W
Failure in the water sensor reading.
Automatically and immediately rearms when the problem is solved.
Serious Error
Probe Failure CO
Failure in the condenser sensor reading.
Automatically and immediately rearms when the problem is solved.
Serious Error
Probe Failure EV
Failure in the evaporator sensor reading.
Automatically and immediately rearms when the problem is solved.
Serious Error
Probe Failure EN
Failure in the ambient sensor reading.
Automatically and immediately rearms when the problem is solved.
Serious Error
Flow Failure
No water flow.
Automatically and immediately rearms when the problem is solved.
Serious Error
Repeated Failure
If there is a failure in the thermal sensor or the pressure switches,
retry up to three times daily.
Manual rearming with technical assitance.
Serious Error
Fan Failure
The equipment checks fan operation. If the fan does not work
properly, the unit stops. Semi automatic rearm: every 30 minutes
the unit will try to start working again.
Serious Error
4WV Failure
The equipment checks the 4 way valve whenever it has to be
engaged. If it is not working properly, the unit stops. Semi
automatic rearm: every 30 minutes the unit will try to start working
again.
Figure 11: Alarm messages.