02.2008 Technical Data Designation Value Order No. 6SE70... 12-0TP_0 14-0TP_0 16-0TP_0 21-0TP_0 Rated voltage [V] • Input DC 510 (- 15 %) to 650 (+ 10 %) • Output 3 AC 0 up to rated input voltage x 0.75 Rated frequency [Hz] • Input --• Output 0 ... 500 Rated current [A] • Input 2.4 4.8 7.3 12.1 • Output 2.0 4.0 6.1 10.2 Motor rated power [kW] 0.75 1.5 2.2 4.0 Auxiliary power supply [V] DC 24 (20 - 30) Max. aux. current requirement [A] • Standard version at 20 V 0.8 • Maximum version at 20 V 1.3 1.3 1.3 1.3 Pulse frequency fp [kHz] 1.7 to 16.0 (see fig. “Derating curves”) Load class II to EN 60 146-1-1 Base load current [A] 0.91 x rated output current Overload cycle time [s] 300 Overload current [A] 1.36 x rated output current Overload duration [s] 60 Extra short-time loading Base load current [A] 0.91 x rated output current Overload cycle time [s] 300 Overload current *) [A] 1.6 x rated output current Overload duration [s] 30 Loses, cooling Efficiency η (rated operation) Power loss (fp = 2.5 kHz) [kW] 0.05 0.06 0.07 0.09 Cooling air requirement [m³/s] 0.002 0.009 0.009 0.018 Pressure drop ∆p [Pa] 10 20 20 15 Sound pressure levels, types of construction, dimensions, weights Sound pressure level [dB(A)] 18 40 40 37 Dimensions [mm] • Width 45 67.5 67.5 90 • Height 360 360 360 360 • Depth 260 260 260 260 Weight approx. [kg] 3.0 3.4 3.4 3.8 21-3TP_0 15.7 13.2 5.5 1.5 0.14 0.041 30 37 135 360 260 8.8 *) With a 1.6-fold overload in field weakening, the torque quality is reduced due to a ripple of 300 Hz. Table 12-2 Technical data of inverter (Part 1) Siemens AG 6SE7087-6KP60 SIMOVERT MASTERDRIVES Operating Instructions 12-3