battery charging is set at 700 mA, then only 1A is left for the auxiliary output. If the battery charging is set at 350mA, then 1.35A is available for the AUX output, but with a maximum of 700mA per output. Table 1: Current Consumption Table Modules Motion Detectors (see detector instructions for details) 636/646* LED Keypads 642* LCD Keypads 708 Ultra Stand-Alone Digital Dialer MG-RCV3 Wireless Expansion Module 2.3.4 Current Consumption Typical 10 to 50mA 15mA 40mA 50mA 50mA Maximum 30mA 55mA 50mA 50mA Battery Test The control panel conducts a dynamic battery test under load every 60 seconds. If the battery is disconnected, or its capacity is too low, the [1] key in the trouble display mode will be on. Key [1] also comes "on" if the battery voltage drops to 10.5 volts or less when the control panel is running on the back-up battery (no AC). At 8.5 volts, the panel shuts down and all outputs close. 2.3.5 Keypad Function Test We recommend conducting a "power-up" test on keypads installed far from the control panel. To do so temporarily connect the keypads near the control panel and connect the transformer. After 10 seconds, begin entering random commands on the keypad and verify that the keypad "beeps" in response to these commands. Then open a zone to ensure that the keypad and the control panel are responding to these signals. If the keypad does not respond and indicator lights do not illuminate, verify that approximately 16Vac is present at the "AC" terminals. If AC is present, check the keypad wiring and verify there isn't a short between the "black" and "red" keypad wires. If the keypad does not respond, please contact your local Paradox Distributor. 2.4 Telephone Line Connection Figure 4 Connect the incoming telephone company wires into the tip and ring connections of the control panel. Then run the wires from T-1 and R-1 to the telephone system as shown in Figure 4. 2.5 Bell/Siren Output. The BELL+ and BELL- terminals power bells and/or other warning devices requiring a steady voltage output during an alarm. The bell output supplies 12Vdc upon alarm and can support two 20-watt or two 30-watt sirens. The bell output is microprocessor-controlled and will automatically shut down if the current exceeds 3A. If the load on the BELL terminals returns to normal (≤3A), the control panel will re-instate power to the BELL terminals. When connecting sirens (speakers with built-in siren drivers) please verify correct polarity. Connect the positive lead to the BELL+ terminal and the negative lead to the BELL- terminal of the control panel as shown in Figure 5. The Alarm Relay (optional), which is rated at 5A, can also be used to power bells and/or other warning devices requiring a steady voltage output during an alarm (see Figure 5). The Alarm Relay is activated (toggles to opposite state) whenever the local bell/ siren output is activated. 4 Reference & Installation Manual Figure 5