Download User Manual - Supri wireless

Transcript
AN5506-04-A
GPON Optical Network Unit
User Manual
Version: A
Code: MN000000423
FiberHome Telecommunication Technologies Co., Ltd.
May 2010
Thank you for choosing our products.
We appreciate your business. Your satisfaction is our
goal. We will provide you with comprehensive technical
support and after-sales service. Please contact your
local sales representative, service representative or
distributor for any help needed at the contact information
shown below.
Fiberhome Telecommunication Technologies Co., Ltd.
Address: No. 5 Dongxin Rd., Hongshan Dist., Wuhan, China
Zip code: 430073
Tel:
+86-27-87691549
Fax:
+86-27-87691755
Website: http://www.fiberhomegroup.com
Legal Notice










TM
TM
TM
are trademarks of FiberHome Telecommunication Technologies Co., Ltd.
(Hereinafter referred to as FiberHome)
All brand names and product names used in this document are used for
identification purposes only and are trademarks or registered trademarks
of their respective holders.
All rights reserved
No part of this document (including the electronic version) may be
reproduced or transmitted in any form or by any means without prior
written permission from FiberHome.
Information in this document is subject to change without notice.
Operation Safety Rules

High optical power can cause bodily harm, especially to eyes.
Never look directly into the end of the optical transmitter fiber
jumper or the end of its active connector.

Exercise care if you must bend fibers. If bends are necessary,
the fiber bending radius should never be less than 38mm.

Power socket overload, broken cables or broken plugs may
cause electric shock or fire. Regular check-ups on power
supply wires and cables are essential. If any appears
damaged, replace it at once.

Use the power supply adapter provided in the package only.
Using other adapters may cause equipment damages or
operation failures.

Install the equipment in ventilated environment without high
temperatures or direct sunlight to protect the equipment and
its components from overheating, which can result in
damages.
I

Avoid moisture, dampness and water damage. Equipment
exposed to water cannot work normally and can be extremely
hazardous due to shorting.

II
Do not lay this equipment on an unsteady base.
Packing List
After opening the packing case of the AN5506-04-A, please check
whether the accompanied articles are in the packing case according to
the packing list as below:
Item
Quantity
Remarks
AN5506-04-A
1
-
Certificate of quality
1
-
User manual
1
AN5506-04-A GPON Optical Network
Unit User Manual
DC power adapter with two
pins
1
DC power adapter with two pins for the
AN5506-04-A
RJ45 connector
5
-
III
Contents
1 Product Introduction ......................................................................... 1-1 1.1 Product Functions.................................................................... 1-1 1.2 Product Types.......................................................................... 1-3
1.3 Technical Specifications ........................................................... 1-4
2 Appearance Description ................................................................... 2-1
2.1 Top Panel and LED Indicators ................................................. 2-1
2.2 Rear Panel and Interfaces ....................................................... 2-3
3 Product Installation ........................................................................... 3-1
3.1 Preparation Before Installation ................................................ 3-1
3.1.1 Unpacking Check ....................................................... 3-1 3.1.2 Installation Precautions .............................................. 3-1 3.2 Placing the Device ................................................................... 3-2
3.3 Cable Connection .................................................................... 3-2
3.3.1
Connection of Network Cable .................................... 3-2
3.3.2
Connection of Optical Fiber........................................ 3-3
3.3.3
Connection of Power Cable ....................................... 3-4
3.4 Examination after Installation................................................... 3-5
4 FAQs ............................................................................................... 4-1 Figures
Figure 1-1
Networking application of the AN5506-04-A ................... 1-2 Figure 2-1 Top panel of the AN5506-04-A ........................................ 2-2 Figure 2-2 Rear panel of the AN5506-04-A ...................................... 2-3
Tables
Table 1-1 Product types ................................................................... 1-3
Table 1-2 Technical specifications of the AN5506-04-A .................... 1-4
Table 2-1 Description of the AN5506-04-A LED indicators ............... 2-2
Table 2-2 Interfaces and buttons of the AN5506-04-A ...................... 2-4
1
Product Introduction
1.1
Product Functions
The AN5506-04-A is a desktop GPON ONU (optical network unit). The
AN5506-04-A is applicable for FTTH scenario. It provides 1 PON
interface for uplink, 4 FE interfaces (or 4 GE interfaces) for downlink, 12
V DC power supply and 20 km transmission distance. As one of the
GPON ONU of the AN5506 series, the AN5506-04-A should work with
the GPON OLT(optical line terminal) of the AN5116 series.
Version: A
1-1
AN5506-04-A GPON Optical Network Unit User Manual
The
following
figure
shows
the
networking
application
of
the
AN5506-04-A:
Figure 1-1 Networking application of the AN5506-04-A
As shown in Figure 1-1, the AN5506-04-A works with the AN5116-06B
(OLT) to build a gigabit GPON system, and they can provide triple-play
multi-service access of high capacity and reliability.
The AN5506-04-A supports the following features:

Adopts GPON interface for uplink, compliant with ITU-T G.984.

Supports the following configurations: Ethernet interface rate,
working mode, MDI/MDIX self-adaption and pause-frame-based
flow control.

Supports packet filtering and anti-illegal message attack protection,
so as to suppress unknown unicast, broadcast and multicast
messages.

1-2
Supports performance statistics of Ethernet lines.
Version: A
1

Supports
DHCP
Option82
reporting
the
Product Introduction
physical
position
information of Ethernet interfaces.

Supports PPPoE+ function for accurate subscribers identification.

Supports IGMP Snooping and IGMP Proxy.

Supports STP / RSTP protocol.

Supports Layer2 /3 wire-speed forwarding.

Downstream data in GPON system adopts triple churning algorithm
for data encryption.

Supports powerful QoS function. Supports global configuration of
queue priority and flexible mapping of 802.1p value of messages.
Supports three scheduling modes: PQ, WRR or PQ+WRR. You can
configure the weight of scheduling queue to ensure QoS of key
services such as voice and video under multiple service conditions.
1.2
Product Types
The AN5506-04-A has two types according to different types of interface.
Table 1-1 lists the two types of the AN5506-04-A and the interface type
and quantity that each product supports.
Table 1-1
Version: A
Product types
Product Type
FE Interface of
Ethernet
GE Interface of
Ethernet
Power
Interface
AN5506-04-A1
4
-
Power socket
with pin
1-3
AN5506-04-A GPON Optical Network Unit User Manual
1.3
Product Type
FE Interface of
Ethernet
GE Interface of
Ethernet
Power
Interface
AN5506-04-A1G
-
4
Power socket
with pin
Technical Specifications
The AN5506-04-A has two types according to different types of interface.
Table 1-2 lists the technical specifications in detail.
Table 1-2 Technical specifications of the AN5506-04-A
Type
Item
Description
Supports IEEE 802.1Q VLAN.
VLAN
Supports the join into 802.1Q VLAN in tag /
untag mode.
MAC address
Supports 8k MAC addresses.
Multicast
Supports IGMP Snooping and IGMP Proxy.
Supports IGMP V1/V2.
Supports 64 VLANs.
Supports 802.1P.
Service
parameter
QoS
Supports priority re-tagging.
Wire speed layer
2/3 switch
All interfaces support wire speed forwarding.
PON interface
One SC/PC interface. The maximum
transmission distance is 20 km.
LAN interface
Dimension
Mechanical
parameter
Power supply
parameter
1-4
Supports QoS classification strategy based
on ports, MAC address and VLAN ID.
AN5506-04-A1: Four RJ-45 interfaces.
Supports full duplex and half duplex,
10/100Mbps self-adaption.
AN5506-04-A1G: Four RJ-45 interfaces.
Supports full duplex and half duplex,
10/100/1000Mbps self-adaption.
27 mm x 63 mm x 117 mm (Height x Width x
Depth)
Shell color
White
Weight
About 300 g
DC
Input voltage: 12 V DC
Consumption
AN5506-04-A1 < 6 W
Version: A
1
Type
Item
Product Introduction
Description
AN5506-04-A1G < 7 W
Environment
parameter
Version: A
Operating
temperature
0˚C to 50˚C
Storage
temperature
-30˚C to 60˚C
Environment
humidity
10% to 90%, non-condensing.
1-5
2
Appearance Description
2.1
Top Panel and LED Indicators
The device body of the AN5506-04-A adopts hollow-carved streamline
design with novel and fashionable appearance. There are some LED
indicators on the top panel indicating the running state of the device, so
that subscribers can understand the device state directly.
Figure 2-1 shows the top panel of the AN5506-04-A, and Table 2-1 lists
the LED indicators.
Version: A
2-1
AN5506-04-A GPON Optical Network Unit User Manual
Figure 2-1
Table 2-1
lists the description of the AN5506-04-A LED indicators.
Table 2-1
Description of the AN5506-04-A LED indicators
LED
Indicator
Name
LED Indicator
Meaning
Power
Power status
indicator
PON
LOS
2-2
Top panel of the AN5506-04-A
Color
Status
Description
On
The device is powered
on.
Off
The device is powered
off.
On
The device is registered
to the GPON system.
Off
The device fails to
register to the GPON
system.
Blinking
The device does not
receive the optical
signal.
Green
Registration
status
indicator
Green
Status
indicator of
optical signal
Red
Version: A
2
LED
Indicator
Name
LAN1/2/3/4
2.2
LED Indicator
Meaning
Status
indicator of
Ethernet
Color
Product Appearance
Status
Description
Off
The device receives the
optical signal.
On
This interface is
connected with the
subscriber terminal but
there is no data
transmission.
Blinking
Data is being transmitted
or received at this
interface.
Off
This interface is not
connected with the
subscriber terminal.
Green
Rear Panel and Interfaces
All the interfaces and buttons of the AN5506-04-A are distributed on the
rear panel of the device, with a compact shape and good utility.
From left to right, on the rear panel of the AN5506-04-A respectively are
4 Ethernet interfaces, Console interface, PON interface, power interface,
reset button, and power switch. See Figure 2-2.
Figure 3-2 Rear panel of the AN5506-04-A
Version: A
2-3
AN5506-04-A GPON Optical Network Unit User Manual
Table 2-2 Interfaces and buttons of the AN5506-04-A
Interface or
Button
2-4
Meaning
Type
Description
Power switch
Button
Switch on/off the power.
Reset
Reset button
Button
Press the button and then
release to restore factory default
settings.
Power
Power interface
Power
interface of
double pin
For connecting DC power
adapter of two pin.
PON
Optical
interface
SC/PC
For connecting the ODN.
Console
Network
interface for
local debugging
RJ-45
For local device debugging. Not
open to subscribers.
LAN1/2/3/4
Ethernet
interface
RJ-45
For connectiong PC, router and
so on.
Version: A
3
Product Installation
3.1
Preparation Before Installation
3.1.1
Unpacking Check
After opening the packing case of the AN5506-04-A, please check
articles in the packing case according to the packing List. If the items do
not match the packing list, contact the local office of FiberHome directly.
3.1.2
Installation Precautions
Before installing the AN5506-04-A please ensure that the following
requirements are met:

There are waterproof, moistureproof and lightningproof conditions
at the installation position.

The installation position can provide conditions for the AN5506-04-A
to connect with the exterior. For example, there should be suitable
outlet space for power supply cable and network cable.
Version: A
3-1
AN5506-04-A GPON Optical Network Unit User Manual

The installation position should be able to ensure enough air flow,
convenient for cooling of the equipment.
3.2
Placing the Device
You can place the AN5506-04-A on the stable plane, such as an office
desk. The placing methods are as follows.

Take out the AN5506-04-A from the packing case. Before delivery,
four rubber pads are pasted to four corners on the bottom of the
device.

Place the AN5506-04-A on a stable desk slightly and ensure the
ventilation on both right and left sides.
3.3
Cable Connection
3.3.1
Connection of Network Cable
The AN5506-04-A Ethernet interfaces can connect subscriber terminals
such as PCs and switches through network cables. Follow these steps to
connect the network cable.

Plan the wiring and cabling mode of the network cable, measure the
distance between the AN5506-04-A LAN interface and the
subscriber terminal, and select the network cable with a suitable
length.
3-2
Version: A
3

Product Installation
Fix the network cable and then make Ethernet connectors for both
ends.

Connect Ethernet connector of one end to a certain AN5506-04-A
LAN interface.

Connect Ethernet connector of the other end to an Ethernet
interface on a PC or a switch.


The connection of the network cable is finished.
Note 1: Transmission distance of the network cable is less
than 100m. Therefore the length of the network cable
prepared by the subscriber should not exceed 100m.

Note 2: The
AN5506-04-A Ethernet
interface supports
MDI/MDIX self-adaption. Either straight-through network cable
or cross-over network cable is suitable for cabling.
3.3.2
Connection of Optical Fiber
The AN5506-04-A adopts wavelength division multiplexing (WDM) mode
and provides “triple-play” integrated access. The connection steps of
optical fibers are as follows.

Plan the wires and cables layout mode of the optical fiber; measure
the distance between the AN5506-04-A PON interface and
upstream optical splitter; select the optical jumper with suitable
length.

Fix the optical fiber; remove the protection covers of the optical
jumper and the AN5506-04-A optical interface.
Version: A
3-3
AN5506-04-A GPON Optical Network Unit User Manual

Insert one end of the optical jumper into the AN5506-04-A PON
interface slightly.

Connect the other end of the optical jumper with the optical splitter.

The connection of optical fibers is finished.

Caution 1: If the optical fiber jumpers are not used, make sure
optical fiber jumpers and the AN5506-04-A optical interfaces
are
covered
to
avoid
dust
contamination
and
water
penetration, which lead to the uselessness of optical fiber
jumpers and the AN5506-04-A optical interfaces.

Caution 2: Connect optical fibers at last if possible. Lay
optical fibers at the position without extrusion.
3.3.3
Connection of Power Cable
The AN5506-04-A adopts the power adapter with two pins, the
connection steps are as follows.

Take out the accompanied DC power adapter with two pins.

Connect one end of the adapter to the power interface of the
AN5506-04-A.
3-4

Connect the other end to AC socket.

The connection of power cable is finished.
Version: A
3

Product Installation
Note: This power adapter can convert 220V AC into 12V DC input
for the AN5506-04-A so as to supply power to the device.
3.4
Examination after Installation
After the connection of wires and cables is finished and relevant services
are started up by your ISP, it needs to power on and examine the
AN5506-04-A as below:

Switch on the power.

Observe the status of Power indicator LED. If Power indicator LED
is on, it means the power-on of the device is normal. Otherwise,
please check whether the connection of power cable is correct.

Observe the status of LOS indicator LED. If LOS indicator LED is
off, it means the optical fiber connection is normal. Otherwise,
please check whether the connection of optical fibers is correct.

Observe the status of LAN indicator LED. If LAN indicator LED is
on or blinks, it means the network cable is connected normally.
Otherwise, please check whether the connection of network cable is
correct.

Ensure the ventilation around during the device running to avoid
problems because of overheating. In the case of abnormity, contact
the local office of FiberHome for replacement, so as not to affect
equipment running.
Version: A
3-5
4
FAQs
Q:
All indicator LEDs are off after power-on.
A: 1)
Check whether the power connection cable is connected well.
2) Check whether the power switch on the front panel of device is on.
Q: The device fails to work after a period of normal running.
A: 1) If the device works abnormally, check whether the power is
connected normally or the voltage is over high or over low.
2)
The device has over-heat fault. Check whether the ventilation is
normal and check whether there is direct sunshine or heat
source around.
Q: LOS indicator LED is on.
A: 1) The optical fiber is faulty. Check whether the optical fiber is
connected normally and whether it is connected to correct
interface.
2) The upstream equipment is faulty.
3)
Version: A
The optical power is out of the normal range (such as overload).
4-1
AN5506-04-A GPON Optical Network Unit User Manual
Q: LAN indicator LED is off.
A: 1) Check whether the network cable is damaged or its connection is
loose.
2) Check whether the network cable is made correctly. If it is
incorrect, replace it with a new network cable made according to
the standard method (for making a CAT 5 twisted-pair cable).
3) Check whether the network cable length exceeds allowable range.
4-2
Version: A
Feedb ack Form
Your
feedback
is
an
important
way
for
us
to
receive
questions,
comments
and
suggestions...ultimately providing you with enhanced manuals and services by FiberHome.
1. Please give your opinions on the items listed below about this manual by the symbol “”.
Items
Excellent
Good
Normal
Expression



Bad

Integrity




Exactitude




Structure




Illustration




Getup




General




2. Please give your advices on the items listed below about this manual by the symbol “”.
 Adjust its structure
 Contents more detailed
 Give more examples
 Expression more concise
 Add more illustrations
 Operationality more ascensive
Please give more details of your advices on this manual:
3. Which part of this manual do you appreciate more?
4. Other advices for our manuals:
5. The personal information requested is used for no other purposes than to respond to your feedback
Name
Job/Position
Working Unit
E-mail
Correspondence Phone Num
Correspondence Facsimile
Correspondence Address
Date
FiberHome Telecommunication Technologies Co., Ltd.
Address:
No. 5 Dongxin Rd., Hongshan Dist., Wuhan, China
Zip code:
430073
Tel:
+86-27-87691549
Fax:
+86-27-87691755
Website: http://www.fiberhomegroup.com