Bostik HeatStep™ Mat Installation Manual
21
Connecting Multiple Mats
NOTE: The HeatStep™ control is not shown in these diagrams in order to simplify them. These diagrams are given only as examples of how to properly connect multiple mats. Care must be taken not to overfill a box. Be sure to use wire nuts that are the
correct size for the connections being made. Follow all codes for wiring. If in doubt, consult an electrician.
Illustration showing how to connect multiple
mats from multiple junction boxes at
one thermostat control electrical box.
L1 = White
L1 = Red
G = Copper
G = Copper
L2 = Black
L2 = Black
Illustration showing how to connect
three mats at the thermostat control
electrical box.
Connecting the Wire fault detector
Illustrations showing (left) how to connect the
Wire Fault Detector to two cables, and (right)
how to connect the Wire Fault Detector to three
mats. The Wire Fault Detector can monitor no
more than three mats simultaneously. Do NOT
leave the power leads connected in “series” like
this when making final wiring connections; the
cables will not heat sufficiently.