Transcript
XW60K EN STANDARD VALUES Label Description SEt Hy LS US ot P2P oE P3P o3 P4P o4 odS AC AC1 rtr CCt CCS Con CoF CF rES rEd dLy dtr tdF dFP dtE idF MdF dSd dFd dAd Fdt dPo dAF FnC Fnd FCt FSt Fon FoF FAP ACH SAA SHy ArP Sdd ALP ALC ALU ALL AFH ALd dAo AP2 AL2 AU2 AH2 Ad2 dA2 AC2 bLL tbA oA3 Set point Differential Minimum set point Maximum set point Thermostat probe calibration Evaporator probe presence Evaporator probe calibration Third probe presence (1st cond. probe) Third probe calibration Fourth probe presence (2nd cond. probe) Fourth probe calibration Outputs activation delay at start up Anti-short cycle delay Second compressor delay P1-P2 percentage for regulation Compressor ON time during fast freezing Set point for continuous cycle Compressor ON time with faulty probe Compressor OFF time with faulty probe Temperature measurement unit Resolution (integer/decimal point) Remote display Display temperature delay P1-P2 percentage for disply Defrost type Probe selection for defrost termination Defrost termination temperature Interval between defrost cycles (Maximum) length for 1° defrost Start defrost delay Displaying during defrost MAX display delay after defrost Draining time First defrost after start up Defrost delay after fast freezing Fans operating mode Fans delay after defrost Differential of temperature for forced activation of fans Fans stop temperature Fan on time with compressor off Fan off time with compressor off Probe selection for fan management Kind of action for auxiliary relay Set Point for auxiliary relay Differential for auxiliary relay Probe selection for auxiliary relay Aux.output working during defrost Probe setting for temperature alarm Temperature alarms configuration MAXIMUM temperature alarm minimum temperature alarm Temperature alarm and fan differential Temperature alarm delay Delay of temperature alarm at start up Probe for temperat. alarm of condenser Condenser for low temperat. alarm Condenser for high temperat. alarm Differ. for condenser temp. alar. recovery Condenser temperature alarm delay Delay of cond. temper. alarm at start up Compr. off for condenser high temperature alarm Compr. off for condenser low temperature alarm Alarm relay disabling Fourth relay configuration AOP i1P i1F Alarm relay polarity Digital input polarity Digital input configuration did nPS OdC rrd HES PbC Adr OnF dP1 dP2 dP3 dP4 rSE rEL Ptb Digital input alarm delay Number of activation of pressure switch Compress and fan status when open door Regulation restart with door open alarm Differential for Energy Saving Kind of probe Serrial address on/off key enabling Room probe display Evaporator probe display Third probe display Fourth probe display Current set point Software release Map code Range LS÷US 0,1÷25,5 °C / 1÷45°F -50,0°C÷SET / -58°F÷SET SET ÷ 110°C / SET ÷ 230°F -12÷12°C / -120÷120°F n; Y -12÷12°C / -120÷120°F n; Y -12÷12°C / -120÷120°F n; Y -12÷12°C / -120÷120°F 0÷255 min. 0÷30 min. 0÷255s 0 ÷ 100 (100=P1, 0=P2) 0 ÷ 23h 50 min. (-55.0÷150,0°C) 0÷255 min. 0÷255 min. °C ÷ °F in ÷ de P1 ÷ 1r2 0 ÷ 20.0 min (10 sec.) 1 ÷ 99 EL, in nP; P1; P2; P3; P4 -50,0÷110°C / -58÷230°F 1÷120h 0÷255 min. 0÷99 min. rt, it, SEt, dEF, dEG 0÷255 min. 0÷60 min. n÷y 0 ÷ 23h 50 min. C-n, C-y, O-n, O-y 0÷255 min. 0÷50°C -50,0÷110°C / -58÷230°F 0÷15 (min.) 0÷15 (min.) nP; P1; P2; P3; P4 CL; Ht -50,0÷110°C / -58÷230°F 0,1÷25,5 °C / 1÷45°F nP / P1 / P2 / P3 n, y P1÷P4 rE÷Ab -50,0÷110°C / -58÷230°F -50,0÷110°C / -58÷230°F 0,1÷25,5 °C / 1÷45°F 0÷255 min. 0 ÷ 23h 50 min. nP; P1; P2; P3; P4 (-55 ÷ 150°C) (-67÷ 302°F) (-55 ÷ 150°C) (-67÷ 302°F) [0,1°C ÷ 25,5°C] [1°F ÷ 45°F] 0 ÷ 254 (min.), 255=nU 0.0 ÷ 23h 50’ n(0) - y(1) n(0) - Y(1) n=no; y=si ALr; dEF; Lig; AUS; onF; Fan; db; dF2 oP; cL oP; CL EAL, bAL, PAL, dor; dEF; Htr, AUS 0÷255 min. 0 ÷15 no; Fan; CPr; F_C n–Y -30°C÷30°C; -54°F÷54°F Ptc; ntc 1÷247 nu, oFF; ES - Default Level Defrost BY AIR TA Defrost BY HOT GAS TN TB Defrost BY HEATERS TN TB -5 2 -50 110 0 Y 0 n 0 n 0 0 1 5 100 0 -5 15 30 °C dE P1 0 50 EL P2 8 6 30 0 it 30 0 n 0 o-n 10 10 2 0 0 P2 cL 0 2 nP n P1 rE 10 10 2 15 1,3 P4 -40 110 5 15 1,3 n n y Lig Pr1 Pr2 Pr2 Pr1 Pr1 Pr2 Pr2 Pr2 Pr2 Pr2 Pr2 Pr1 Pr2 Pr2 Pr2 Pr2 Pr2 Pr2 Pr2 Pr1 Pr2 Pr2 Pr2 Pr1 Pr2 Pr1 Pr1 Pr1 Pr2 Pr2 Pr2 Pr2 Pr2 Pr2 Pr1 Pr1 Pr2 Pr1 Pr2 Pr2 Pr2 Pr2 Pr2 Pr2 Pr2 Pr2 Pr2 Pr2 Pr1 Pr1 Pr2 Pr2 Pr2 Pr2 Pr2 Pr2 Pr2 Pr2 Pr2 Pr2 Pr2 Pr2 Pr2 10 2 10 15 0 n 0 n 0 n 0 0 2 0 100 0 -5 0 0 c in P1 0 50 EL P2 20 3 20 0 rt 0 0 n 0 o-y 3 0 40 0 0 nP CL 0 2 nP n P1 re 5 5 2 15 3 nP -40 110 5 15 1,3 n n y Lig 0 2 -5 5 0 y 0 n 0 n 0 0 2 0 100 0 -5 0 0 c in P1 0 50 in P2 20 3 20 0 rt 0 2 n 0 o-n 3 0 40 0 0 P2 CL 0 2 nP n P1 re 5 5 2 15 3 nP -40 110 5 15 1,3 n n y Lig. -22 2 -18 -25 0 y 0 n 0 n 0 0 2 0 100 0 -5 0 0 c in P1 0 50 in P2 20 3 20 0 rt 0 2 n 0 o-n 3 0 40 0 0 P2 CL 0 2 nP n P1 RE 5 5 2 15 4 nP -40 110 5 15 1,3 n n y Lig. 0 2 -5 5 0 y 0 n 0 n 0 0 2 0 100 0 -5 0 0 c in P1 0 50 EL P2 30 3 30 0 rt 0 2 n 0 o-n 3 0 40 0 0 P2 CL 0 2 nP n P1 re 5 5 2 15 3 nP -40 110 5 15 1,3 n n y Lig. -22 2 -18 -25 0 y 0 n 0 n 0 0 2 0 100 0 -5 0 0 c in P1 0 50 EL P2 30 3 30 0 rt 0 2 n 0 o-n 3 0 40 0 0 P2 CL 0 2 nP n P1 RE 5 5 2 15 4 nP -40 110 5 15 1,3 n n y Lig. cL cL dor Pr2 Pr1 Pr1 cL Op dor cL Op dor cL Op dor cL Op dor cL Op dor 15 15 F-c y 0 ntc 1 oFF 1,1 - Pr1 Pr2 Pr2 Pr2 Pr2 Pr2 Pr1 Pr2 Pr1 Pr1 Pr1 Pr1 Pr1 Pr2 Pr2 60 10 f-c n 0 ntc 1 oFF 1,1 - 60 10 f-c n 0 ntc 1 oFF 1,1 - 60 10 f-c n 0 ntc 1 oFF 1,1 - 60 10 f-c n 0 ntc 1 oFF 1,1 - 60 10 f-c n 0 ntc 1 oFF 1,1 -