Download USER MANUAL
Transcript
WWSRF platforms WWSRF_03_11.11_EN_U LOCKED/UNLOCKED/DISABLED TARE SELECTION Normally, when a tare value is entered (automatic or manual) by unloading the scale plate, the display shows the tare value with a negative sign (LOCKED TARE). For one’s convenience it is also possible to choose that the tare value cancels itself automatically each time that the scale is unloaded (UNLOCKED TARE); or disable the tare functions. With the UNLOCKED tare: In case of SEMIAUTOMATIC TARE the net weight, before unloading the scale, may also be 0. In case of MANUAL TARE the net weight before unloading the scale must be greater than 2 divisions and stable. To set the type of tare: - Turn on the indicator, press the TARE while the firmware version is displayed (the display shows the “tyPE” menu). - Press ZERO many times (to scroll ahead through the parameters) or TARE (to scroll backwards) until one finds the “F.ModE” parameter. - Press ENTER/PRINT to enter the menu. - Press ZERO many times (to scroll ahead through the parameters) or TARE (to scroll backwards) until one finds the “tArE” parameter. - With the ZERO or TARE keys select the possible options: “LoCK” (locked tare), “unLoCK” (unlocked tare), “diSAb” (disabled tare). - Confirm with ENTER/PRINT. - Press the C key many times until the display shows the message “SAVE?”. - Press ENTER/PRINT to confirm the changes made or another key for not saving. 8.3 LIMITATION OF THE TARE FUNCTIONS With approved instrument, it is possible to limit the tare functions, by setting “yES” in the step SEtuP >> d.SALE (TECH.MAN.REF.). The tare operations will have the following specifications: SCALE CAPACITY < 100kg ≥ 100kg FUNCTIONING SEtuP >> d.SALE >> rEM.dSP >> no SEtuP >> d.SALE >> rEM.dSP >> yES (no remote display for the visualization of the (remote display for the visualization of the tare) tare) All the tare functions are disabled. - The SEMIAUTOMATIC TARE value can not be modified with a manual tare. - The manual tare can be entered or modified only with an UNLOADED scale and tare equal to zero. - It’s possible to cancel the tare value only with an UNLOADED scale, by pressing the ZERO key or by entering a manual tare equal to zero. - The SEMIAUTOMATIC TARE value can not be - The SEMIAUTOMATIC TARE value can not be modified with a manual tare. modified with a manual tare. - The manual tare can be entered or modified only - The manual tare can be entered or modified with an UNLOADED scale and tare equal to only with an UNLOADED scale and tare equal zero. to zero. - It’s possible to cancel the tare value only with an - It’s possible to cancel the tare value only with UNLOADED scale, by pressing the ZERO key an UNLOADED scale, by pressing the ZERO key or by entering a manual tare equal to zero. key or by entering a manual tare equal to zero. With approved instrument, the d.SALE and rEM.dSP steps are read-only. 8.4 AUTO POWER OFF FUNCTION It is possible to automatically turn off the indicator (from 1 to 255 minutes), or disable it; the auto power off takes place when, with unloaded scale, the weight has not been moved or a key has not been pressed for the time set: the display shows the “- oFF – “ blinking message and an acoustic signal is emitted; after this the indicator turns off. For the setting, follow the procedures below: - Turn on the scale, press the TARE key while the firmware version is displayed (the display shows the “tyPE” menu). - Press ZERO many times (to scroll ahead through the parameters) or TARE (to scroll backwards) until one finds the 9