Download User's Guide DG1000 Series Dual-Channel Function/Arbitrary
Transcript
RIGOL 1. N-Cycle/ Gated N-Cycle has specific number of waveform cycles, and every burst is activated by a trigger event. Gated burst use external source to control burst when to be activated. 2. Cycle Number Set the number of Waveform Cycle in an N-Cycle (1 to 50,000 or Infinite). If you choose Infinite, then a continuous waveform will be generated. If needed, Burst Period will increase to cater to the specific number of cycles. For an infinite-cycle Burst, External or Manual Trigger is needed to activate burst. For Manual Trigger, a trigger will be generated for the first time when you press Manual and stop after the second press. 3. Phase Define the Start and the Stop Point in a waveform. The phase varies from -180° to +180°, and the default setting is 0°. For an Arbitrary Waveform, 0° is the phase of the first waveform point. 4. Period Set the time span between an N-Cycle Burst to the next. If necessary the period will increase to allow the specific number of cycles in a burst. Burst Period> Period X Burst Number 5. Delay Set the Time Delay between the Trigger Input and the Start of the N-Cycle Burst. The delay should be greater than (or equal to) 0 and less than the specific burst period. Press View, in the Graph Mode, the waveform is shown in the following figure. Burst Period Start Phase Delay Cycle Times N-Cycle Figure 2-46 Waveform Parameter in the Graph Mode © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-39