Download Operating Instructions Emissions Analysis Measuring Instrument

Transcript
Operating Instructions
Emissions Analysis Measuring
Instrument EAM 3.011 - S20
Program description
1
Before starting up and operating the unit, always read through the operating instructions
and particularly the safety instructions thoroughly. In this way, you can avoid any uncertainties
with respect to use of the unit, thus ensuring
your own safety and preventing damage occurring to the unit.
All work on the engine, as well as the connection of testers in the engine area and on the
ignition system, must be performed only when
the engine is not running and the ignition is
switched off.
Bosch - Test Technology
Certified Quality-Management-Systems according to DIN EN ISO 9001
by:
Reg. Nr.: 4066-01
Reg. Nr.: Z-1037-17
Licencing agreements
By using this program, you agree to be bound by the following
terms and conditions:
UK MOT approved for vehicles category A and B
1. Copyright:
This software and data is the property of Robert Bosch GmbH or
her suppliers and is protected with respect to duplication by
copyright laws, international agreements and other national legal
provisions. No part of this data and software may be duplicated
or sold and such action is a punishable offence; should these
conditions be contravened, Robert Bosch GmbH shall reserve
the right to prosecute and to claim damages.
For your nearest UK Service point please
contact:
2. Liability:
Robert Bosch Ltd
P.O.Box 98,
Broadwater Park
North Orbital Road
Denham, Uxbridge
Middlesex. UB9 5HJ
All data in this program are based as far as possible on manufacturers’ and importers’ specifications. Robert Bosch GmbH shall
accept no liability for the accuracy and completeness of this
software and data, nor for any damage caused by faulty software
and data. In all cases, the extent of liability of Robert Bosch GmbH
shall be limited to the actual amount the customer has paid for this
product. This disclaimer of liability shall not apply to damage
caused willfully or through gross negligence on the part of Robert
Bosch GmbH.
Tel.: 01895 838 888
Fax: 01895 838 349
(C) Copyright 1994 Robert Bosch GmbH
All rights reserved.
2
Contents:
Instructions for your personal safety and
for the protection of equipment/vehicle components
1.
1.1
1.2
1.3
1.4
1.5
1.6
Page
4
1.7
General Information
Application
Who it is made for
Guarantee
Description of the unit
Operating the RTM 430 Opacimeter
Publication entitled "Connecting Test Systems
to the Vehicle"
Definitions of terms
2.
2.1
2.2
2.3
2.4
2.5
2.6
2.7
The Basics
The display
What the keys mean
Program control
RPM measurement
Program and menu overview
The sequence charts
Overview of the exhaust-gas test
7
7
7
7
8
10
10
10
3.
3.1
3.2
3.3
3.4
3.5
The EGA Diesel (Diesel exhaust-gas analysis test)
Vehicle and customer identification
Setpoint input and measuring parameters
Engine preconditioning and prechecks
Rev-up measurement
Display measurement results
11
11
12
13
14
15
4.
4.1
4.2
The "Diagnosis" Menu
Continuous measurement
Free acceleration
16
17
17
5.
5.1
5.2
5.3
5.4
5.5
5.6
5.7
The "Configuration" Menu
Overview
Software versions
Language
Date and time
Report heading
Printer
Units
18
18
19
19
19
19
19
19
6.
6.1
6.2
6.3
6.4
6.5
The "Test Functions" Menu
Overview
Engine speed (RPM)
Oil temperature
Battery voltage
Print
20
20
20
20
20
20
7.
The "Service" Menu
21
8.
8.1
8.2
8.3
8.4
8.5
The "Calibration" Menu
Overview
Calibration date
Calibration measurement
Check
CRC check
21
21
22
22
22
22
9.
Error Messages
22
10. Maintenance
10.1 Checking display accuracy
10.2 Maintaining the calibrating pen
6
6
6
6
6
6
6
6
23
23
23
3
Instructions for your personal safety and for the protection of
equipment/vehicle components
Mains voltages
Danger of acid burning
in the respiratory system
High voltage
Hazardous voltages occur in both the lighting system and the
electrical system of a motor vehicle. If contact is made with live
parts (e.g. with the ignition coil), there is a risk of electric shock
from flashover voltages caused by damaged insulation (e.g.
ignition cables which have been attacked by martens). This
applies to both the primary side and the secondary side of the
ignition system, to the cable harness and the plug connections, to
the lighting systems (Litronic) and to the tester connections.
When exhaust gas measurements are taken, the sampling hoses which are used release a highly caustic gas
(hydrogen fluoride) that can cause acid burning in the respiratory
system when heated to temperatures in excess of 250 °C (482
°F) or in the event of fire.
Safety precautions:
- All testers must be connected to properly grounded, shockproof sockets.
- Testers must always be connected using the power cables
supplied with them.
- All extension cables must be fitted with shock-proof contacts.
- Any cables with damaged insulation must be replaced (e.g.
power or ignition cables).
- Connect testers to the lighting system and switch them on
before connecting them to the vehicle.
- Connect testers to the engine ground or to the battery (B-)
before switching on the ignition.
- Always switch off the ignition before performing any work on
the electrical system of the vehicle. The term "work" includes
connecting testers, replacing parts of the ignition system,
removing assemblies (e.g. generators), connecting assemblies
to a test bench, etc.
- Wherever possible, tests and settings should always be carried
out with the ignition switched off and the engine stationary.
- If tests or settings are carried out with the ignition switched on
or the engine running, care must be taken not to touch any live
parts. This applies to all the connecting cables of the testers as
well as to the connections of any assemblies at the test bench.
- Test connections must always be made using suitable connectors (e.g. Set of Test Cables 1 687 011 208 or vehicle-specific
adapter cables).
- Make sure that all test connections are properly plugged in and
secure.
- Never open the casing of the screen.
- Always wear gloves made of neoprene or PVC
when removing combustion residues.
Safety precautions:
- Consult a doctor immediately after inhaling!
- Neutralize any residues left after a fire with a calcium hydroxide
solution. This produces non-toxic calcium fluoride, which can
be washed away.
Danger of acid burning
Acids and alkalis can cause severe burning on unprotected
skin. Hydrogen fluoride forms hydrofluoric acid in combination
with moisture (water).
The condensate which accumulates in the sampling hose and
in the condensate container likewise contains acid.
When replacing the O2 sensor, it should be remembered that it
contains alkali.
Safety precautions:
- Rinse any affected parts of the skin immediately in water, then
consult a doctor!
- The O2 sensor is a hazardous waste and must be disposed
accordingly. Bosch technical equipment suppliers are able to
dispose of the sensors O2 in the appropriate manner.
If liquid crystal escapes from a damaged liquid crystal display,
it is imperative to avoid direct contact between the liquid and the
skin, as well as inhalation or swallowing!
Safety precautions:
- Wash the skin and clothing thoroughly with soap and water if
it comes into contact with liquid crystal.
- Consult a doctor immediately after inhaling or swallowing liquid
crystal.
4
Instructions for your personal safety and for the protection of
equipment/vehicle components
Danger of asphyxiation
Car exhaust fumes contain carbon monoxide (CO) - a colorless,
odorless gas. If inhaled, carbon monoxide causes an oxygen
deficiency in the body. Extreme caution is therefore essential
when working in a pit, as some of the components of the exhaust
gas are heavier than air and settle at the bottom of the pit.
Caution is also necessary when working on LPG-driven vehicles.
Safety precautions:
- Always ensure effective ventilation and suction (especially
when working in a pit).
- Always switch on and connect the suction plant in a closed
area.
Danger of burning
When working on a hot engine, there is a risk of injury from
burning if such components as the exhaust gas manifold, the
turbocharger, the Lambda sensor, etc. are touched or if parts of
the body come too close to them. These components may be
heated to temperatures of several hundred degrees Celsius.
Depending on the duration of the exhaust gas measurements, the
sampling probe of the exhaust gas measuring instrument may
also become extremely hot.
Safety precautions:
- Always wear protective clothing, e.g. gloves.
- Allow the engine to cool down first (this also applies to auxiliary
heating systems).
- Keep the tester connecting cables well away from all hot parts.
- Do not leave the engine running any longer than necessary for
the test or setting.
Danger of injury
Noise
Danger of crushing
If the vehicle is not prevented from rolling away, there is a danger
of people being crushed against a workbench, for example. Both
running and stationary engines have rotating and moving parts
(e.g. belt drives) which may cause injuries to fingers and arms. A
special hazard is presented by electrically driven fans, in that they
may be switched on without warning while the engine is stationary
and the ignition is switched off.
There is a danger of tripping over the protruding rollers, the
connecting cables and the power cable of the test system.
Do not place heavy objects on or lean on the sensor holder,
because there is a danger of it breaking and falling on your feet.
Noise levels in excess of 70 dB(A) can occur when measurements
are carried out on a vehicle, especially at high engine speeds.
Damage to hearing may result if human beings are exposed to
noise at such levels over an extended period of time.
Safety precautions:
- If necessary, noise protection facilities must be provided by the
owner at all workplaces in the vicinity of the testing area.
- If necessary, suitable personal noise protection facilities must
be used by the operator.
Safety precautions:
- Take steps to prevent the vehicle from rolling away while it is
being tested.
Select the park position if the vehicle has an automatic transmission and apply the handbrake or lock the wheels with
chocks (wedges).
- Keep well away from rotating/moving parts while the engine is
running.
- When working on or in the vicinity of electrically driven fans,
allow the engine to cool down first, then disconnect the plug of
the fan motor.
- Keep the tester connecting cables well away from all rotating
parts.
- Lock the brakes on the test system trolley so that it cannot roll
away.
- Lay the connecting cables in such a way that no-one can trip
over them.
- Do not place heavy objects on or lean on the sensor holder.
5
1. General Information
1.7 Definitions of terms
1.1 Application
Effective measuring length:
- The effective measuring length is the light segment through
which the smoke passes. It has a length of 430 mm. The
determined measured values are converted as a function of
the length of the measuring chamber.
The Emissions Analysis Measuring Instrument (EAM) is used for
measuring the emissions (of smoke) from diesel-engined vehicles.
1.2 Who it is made for
The Emissions Analysis Measuring Instrument has been built
for trained, expert personnel in the automotive sector. In order
to ensure your own safety and to prevent damage to the
equipment as a result of improper use, please read the
information in these Operating Instructions carefully.
1.3 Guarantee
Never carry out any modifications to our products. Furthermore,
KH-PR products must only be used in conjunction with genuine
accessories.
Non-compliance shall render all terms of the guarantee void.
Despite having taken the utmost of care while programming,
compiling and checking we cannot guarantee for the accuracy of
the operating software (SystemSoft).
1.4 Description of the unit
The design, operation and method of connecting the unit to the
vehicle can be found in the separate Operating Instructions.
Emissions Analysis Measuring Instrument Description of the Unit
IA4-UBF 957/1
1 689 981 664
1.5 Operating the RTM 430 Opacimeter
A basic description of the RTM 430 opacimeter covering its
design, operating instructions, maintenance, technical data
and scope of delivery, is contained in the RTM 430 Operating
Instructions manual supplied:
Opacimeter RTM 430
IA4-UBF 956/1
1 689 979 651
1.6 Publication entitled "Connecting Test Systems to the
Vehicle"
Useful information concerning the connecting of test systems and
their sensors can be found in the following publication:
Connecting Test Systems to the Vehicle
KH-PR UBF 550/1 En
6
1 689 979 625
Absorption coefficient (k factor) [m-1]
- The absorption coefficient is a measure of the amount of light
absorbed by the soot, white smoke and blue smoke related
to 1 m light segment. Therefore, this coefficient is independent of the used unit.
2. The Basics
- Letters keys
2.1 The display
A-Z
The display consists of a 2-line LCD with 16 characters per
line. This means that a number of words must be abbreviated.
Long instructions are displayed as moving-letter displays that
repeatedly run across the screen. The display is backlit and
this function can be switched on and off by means of the key
combination SHIFT + I.
SHIFT + <Key with yellow lettering>
Key combination for entering the special
yellow character
- Special function keys
#
For storing measured values
(for continuous measurement and checking
only).
SHIFT + I
Key combination for switching the backlighting on and off.
2.2 What the keys mean
- The cursor keys are used for selecting options in menus
(Standard mode) or for moving the cursor (Edit mode).
v
z
Menu selection or move cursor one character
to the right.
Menu selection or move cursor one character
to the left.
Keys for entering letters
SHIFT + ENT Key combination for "one step back"
2.3 Program control
2.3.1 The Program or Operation mode
- Confirmation key
ENT
Confirming menu selection or input, or progressing through the test program.
- Cancel key
ESC
For the most part, control of the program consists simply of
confirming the test steps specified. This is done using the top
keys on the hand-held control unit. If there are several menu items
or selection options to choose from, this is indicated by means of
selection arrows < and > in the 2nd line. In such cases, the left
menu can be selected using the z and v cursor key sand the
right menu or another setting option using the or DEL key.
Cancel the current program step and return to
the main menu.
2.3.2 Input or Edit mode
- Delete key
DEL
Values or texts that can be changed can be changed in Input
mode. There are 2 possibilities:
Menu selection to the right like v (Standard)
or deletes the character to the left of the
cursor (Edit mode).
- The type of input is identified by the flashing cursor on the left
of the input field. Characters can be entered directly.
- Shift key
SHIFT
Switches over to the second level of key
assignments (input of the yellow characters).
Shift only applies to the next character.
● The content of the field flashes; inputs have already been made
- In this case, the entry can be overwritten directly. When the first
character is entered, the old entry is deleted completely and the
new character you have entered appears together with the
cursor.
- Space bar
SPACE
● The field is empty; no input has been made so far
Inserts a blank.
- You want to delete, add to or change the old entry. The cursor
is not yet visible.
- Number keys
0-9
Keys for entering numbers
•
Decimal point
DEL Deletes the entry and the cursor appears on the left.
z The cursor appears under the 1st character and this can
be overwritten.
v The cursor appears after the least character and characters
can be added.
7
As soon as the cursor is visible, you are in Input or Edit mode and are
able to move the cursor by means of the cursor keys in order to
change individual characters. The keys have the following meaning:
z
v
DEL
ESC
Move cursor one character to the left.
Move cursor one character to the right.
Deletes the character to the left of the cursor and
the remaining characters are shifted to the left.
Rejects the changes and displays the old content
again as a flashing display. The cursor disappears.
2.4 RPM measurement
The engine and ignition must always be switched off
before any work is carried out on the ignition system.
Before performing RPM measurement (engine-speed
measurement), always connect the B- clamp of the
battery connecting cable (B+/B-) to vehicle earth.
Preparing the measuring point:
- The clearance between the clip-on sensor and the next bend in
the tubing must be at least 10 mm.
- Clean the clamping point in a straight section of the injection
tubing using sandpaper.
- The metal at the clamping point must be bare and must be
totally smooth (no dents etc.). Remove the insulation from
around insulated injection tubing.
Connecting to the vehicle:
- Determine the diameter of the injection tubing and select an
appropriate clip-on sensor. The standard clip-on sensor
KG6 (6 mm) is enclosed. If the car in question has injection
tubes with a different diameter, your can order appropriate
clip-on sensors (available as special accessories).
- Connect the clip-on sensor to the connecting cable (blade
receptacle).
i Only ever connect one engine-speed sensor. The system
automatically selects the engine-speed sensor connected.
- Connect the black clamp of the connecting cable to vehicle
earth.
Set the number of pulses and cylinders in accordance with
the source used for picking up the engine speed (RPM).
! Only use a clip-on sensor that matches the diameter of the
injection tubing.
2.4.1 The clip-on sensor
● Measuring point
i Clip-on sensors are wearing parts.
! The points listed below must always be observed when
handling clip-on sensors, so that damage to the foil in the clipon sensor and therefore failures can be avoided and the
service life of the pickup can be extended.
A
>10
mm
B
- The clip-on sensor must not be rotated after being clamped
with the securing clip.
- Only use a clip-on sensor that matches the diameter of the
injection tubing. If the diameter of the clip-on sensor is too
large, it is not possible to measure the engine speed (RPM).
If the diameter of the clip-on is too small, the pickup may be
irreparably damaged.
- Never use emery paper or other tools to clean the clip-on
sensor.
Connecting to the Emission Analysis Measuring Instrument:
- Connect the clip-on sensor connecting cable to plug-in socket
2 of the Emission Analysis Measuring Instrument (see
Description of the unit).
- Connect the Emission Analysis Measuring Instrument (plugin socket 1, see Description of the unit) to vehicle earth using
clamp B- of the battery connecting cable (B+/B-) in order to
achieve equipotential bonding during RPM measurement
(engine-speed measurement).
8
459331/1P
- The clamping point must be perfectly smooth.
If the injection tubing is too thin, clamp the clip to the
next metal part available.
i The clip-on sensor must not be rotated around the
injection tubing after being clamped. The clip-on sensor
must be clamped onto the injection tubing in such a way
that it does not make contact with any other components
(wires, hoses, engine etc.).
- Clamp the clip-on sensor onto the cleaned section of
injection tubing as shown in the figure.
When making the connection, injection tubing level A must
flush with the the switching surface (level B) of the clip-on
sensor.
● Number of pulses
The number of pulses used for RPM measurement (engine-speed
measurement) using a clip-on sensor depends upon the type of
engine. The number of pulses must be set accordingly:
- with a 4-stroke engine, 1 pulse
- with a 2-stroke engine, 2 pulses
2.4.4 RPM measurement (engine-speed measurement) by
means of alternator residual ripple (battery connecting
cable B+/B)
The battery connecting cable (B+/B-) is used to measure the
engine speed (RPM) of compression-ignition (diesel) engines
by means of the vehicle electrical system.
● Functional description
2.4.2 The TDC sensor
● Measuring point
If the vehicle manufacturer has installed a TDC sensor in the
vehicle or there is a hole provided for fixing the workshop TDC
sensor to be used, RPM measurement (engine-speed measurement) can be carried out using this sensor.
The engine speed (RPM) is measured by evaluating the residual
ripple of the alternator output voltage. This signal is, however,
superimposed by interference. To be able to detect the useful
signal amongst this interference, an adaptation phase of approx.
15 to 30 seconds is required before the measurement phase.
● Measuring procedure
- Connect the vehicle-specific TDC-sensor connecting cable to
plug-in socket 3 of the Emission Analysis Measuring Instrument
(see Description of the unit) and to the vehicle.
● Number of marks
The number of pulses used for RPM measurement (engine-speed
measurement) using a TDC sensor depends upon the type of
TDC-sensor system.
You must know how many pins or notches there per 360° rotation
of the crankshaft.
- Switch off the engine.
- Using the battery connecting cable (B+/B-), connect the VSM
(plug-in socket 1, see Description of the unit) to the vehicle
battery. The battery connecting cable is protected against
polarity reversal.
i When working on a 24-V vehicle electrical system, connect
to 24V! Do not connect the VSM just to one of the 2 batteries.
The voltage range is from 9 to 32 V. When working on a
vehicle with a number of independent batteries (e.g. a
camping bus), connect the battery connecting cable (B+/B-) to
the battery that is charged directly by the vehicle alternator.
- Set the number of cylinders accordingly.
2.4.3 The RIV sensor
● Measuring point
- Connect the RIV sensor to the injection pump.
- Connect the connecting cable of the RIV sensor to plug-in
socket 2 of the Emission Analysis Measuring Instrument
instead of the clip-on sensor connecting cable (see
Description of the unit).
- Start the engine and accelerate briefly so that the charge
indicator lamp in the vehicle goes out.
i Switch on the vehicle lights and if fitted the rear heated
window.
Switch off the blower and other consumers.
- Leave the engine running at idle speed.
- The engine speed (RPM) measured can be checked in the
"Engine preconditioning and prechecks" test step.
● Number of pulses
The number of pulses used for RPM measurement (engine-speed
measurement) using an RIV sensor depends upon the type of
engine. The number of pulses must be set accordingly:
- for 4-stroke engines: pulse number 1
- for 2-stroke engines: pulse number 2
The engine speed (RPM) measured is displayed after approx.
15 to 30 seconds.
i If RPM measurement (engine-speed measurement) does not
result in a value being displayed, first check whether the
polarity of the connections is correct.
You can now perform a test rev-up.
i The engine must be at normal operating temperature!
When performing the test rev-up, watch the breakaway speed. If
the breakaway speed displayed is plausible and stable,the engine
speed (RPM) measured by means of the alternator’s residual
ripple is correct. If not, you must choose a different method of
measuring the engine speed (RPM).
9
2.5 Program and menu overview
2.6 The sequence charts
When you switch on the Emission Analysis Measuring Instrument
(EAM), the software first of all carries out a self-test. Afterwards,
the main menu appears containing 6 menu items (selection
options) that are selected using the cursor keys z and v and
confirmed by pressing the ENT key.
The sequence charts illustrated below show you the respective
texts displayed on the hand-held control unit in rectangular boxes
with two lines of text, single-lined boxes, as they are displayed in
uppercase letters on the display.
-
The keys you need to press to move forwards and backwards in
the sequence or to change or make inputs are marked by arrows
in the text.
EGA Diesel (Diesel exhaust-gas analysis test)
Diagnosis
Configuration
Test functions
Service
Calibration
Lozenges, branching symbols etc. indicate program-internal
sequences and decisions as specified either by the user or by
statutory regulations.
2.7 Overview of the exhaust-gas test
Self test VSM
The basic test sequence is shown in the following figure:
AUTOM.
Download TDM firmware
Main Menu
AUTOM.
SELECTION ?
< EGA-DIESEL >
RTM and TDM self-tests.
In case of malfunction,
show cause
AUTOM.
ENT
SELECTION
EGA DIESEL
DIAGNOSIS
CONFIGURATION
TEST FUNCTIONS
SERVICE
CALIBRATION
Vehicle
Identification
DIAGNOSIS
EGA DIESEL
C O N FIGURATION
CONT. MEASURE
REV-UPS
SW-VERSIONS
LANGUAGE
DATE/TIME
REPORT HEADING
PRINTER
UNITS
TEST FUNCTIONS
RPM
OIL TEMPERATURE
VOLT-BATTERY
PRINT
Rated value input
and
measured
parameters
Key ESC before measuring block :
Abortion after Main Menu
CODE xxxx
SERVICE
CALIBRATION
CALIB. DATE
CALIB. MEASURE
LINEARITY
CRC-CHECK
IFACE PC/HOST
IFACE TDM
Key ESC after 1 measurement:
Abortion after Result Menu
IFACE RTM
IFACE GAM
DISK
PRINTER INTERN
PRINTER EXTERN
DTL-KEYS
DTL-DISPLAY
SYSTEM_e.VSD
Each of these menu items is described in a separate section.
Most of the menu items offer a submenu that contains further
selection options.
Vehicle
conditioning,
CUTOFF SPEED
measurement
Measurement
rev-ups
The test procedures and setting/selection options are described
below in detail with the aid of sequence charts.
Result Display
10
3. The EGA Diesel (Diesel exhaust-gas analysis test)
By pressing SHIFT + ENT, you can return to the
previous input field; pressing repeatedly brings you
back to the main menu. However, if you change the
registration number, the program assumes that you
are dealing with a new customer and automatically
deletes all previous data.
3.1 Vehicle and customer identification
This menu is where you enter data for identifying the vehicle and
customer.
This data is then printed out together with the test result.
Old
The report printout contains the data last entered. It is
not possible to make any changes.
from Main Menu
EGA Diesel
Vehicle and
customer
identification
IDENTIFICATION?
WITHOUT
in configuration PRINTER
ON/OFF
IDENTIFICATION?
NEW
>
>
IDENTIFICATION?
<
OLD
ENT
VEHICLE
IDENTIFICATION
Yes
VEH. LIC. PLATE
ENT
new veh. lic. plate?
Yes
delete old data
SHIFT+ENT
VEHICLE MAKE
_
SHIFT+ENT
ENT
No
VEHICLE MODEL
_
SHIFT+ENT
ENT
VEHICLE TYPE
_
SHIFT+ENT
ENT
ENT
MILEAGE
_
ENT
Customer
IDENTIFICATION
Yes
CUSTOMER
6 * 24 CHARACTERS
ENT
1 LINE
_
No
ENT
----6 LINE
_
ENT
ENT
There are three options for vehicle/customer identification:
None
The report printout contains no details about the vehicle
and customer.
New
The report printout contains the data that you input
during the following procedures. Old customer data is
not deleted; it is displayed and can be altered (see
section 2.3.2, Input or Edit mode). By pressing ENT,
you confirm an input and move on to the next input
field.
11
3.2 Setpoint input and measuring parameters
3.2.1 Selecting vehicle category
Each exhaust-gas analysis test requires setpoints and measuring
parameters. This data must be input into the exhaust-gas
measuring system as reference values, so that the measured
values can be compared and evaluated.
Using the arrow keys z and v, select vehicle category A or
category B.
This data can be procured either direct from the vehicle manufacturer
or importer, or purchased from institutes or publishing houses that
compile the data from various vehicle manufacturers.
This data can be entered manually into the relevant input fields.
3 to 6 measurement rev-ups are performed for category A
vehicles.
4 to 10 measurement rev-ups are performed for category B
vehicles.
By pressing ENT, you confirm an input and move on to the next
input field.
3.2.2 Selecting engine type
from vehicle and customer
identification
In this input field, you must select the engine type “ASPIRATED”
or “TURBOCHARGED” using the arrow keys z and v. There
are different limit values in the standard at this point for the
respective categories. These are used correspondingly to
evaluate the EGA.
Rated value input
and measured
parameters
By pressing ENT, you confirm the engine type selected and move
on to the next input field.
3.2.3 Selecting the probe to be used
The emission probe used must be selected with the arrow keys
z and v.
Probe 1 with a 10mm diameter or probe 2 with a 16mm diameter.
VEHICLE ?
CATEGORY A >
VEHICLE ?
<
CATEGORY B
ENT
ENT
ENGINE ?
ASPIRATED
>
ENT
PROBE ?
1 (10 mm)
ENT
ENGINE ?
<
TURBOCHARGED
ENT
>
PROBE ?
< 2 (16 mm)
ENT
for idle speed and cutoff
speed measurement
12
By pressing ENT, you confirm the probe type selected and move
on to the next input field.
- Adjust the immersion depth of the oil-temperature sensor to
match that of the oil dipstick (see figure).
3.3 Engine preconditioning and prechecks
from rated value
input and measured
parameters
Program sequence depends on
system configuration.
Engine conditioning
Idle speed
Cutoff speed
measurement
COMPLY WITH TEST
CONDITIONS.
ENT
OILTEMPERATURE
(60-90)
88.0 °C
ENT only possible with category A and
oil temperature more than 60 °C
ENT
REMOVE OILTEMP.
PROBE
90
ENT only possible with category A and
oil temperature less than 60 °C
ENT
SPEED
788 /rpm
PULSES 1
#>
SPEED
788 /rpm
< PULSES 2
#>
ENT
......
P
94
45
SPEED
788 /rpm
< PULSES 25.5 #
#
ENT
SPEED
PULSES
- - - - /rpm
25.5
ENT is possible if no speed is measured, then triggering in RTM to follow.
- Insert the oil-temperature sensor instead of the oil dipstick.
Speed > 0
No
- The engine-oil temperature is displayed.
SHIFT+ENT
Yes
SPEED
RESTZEIT
- Remove the oil-temperature sensor (ENT only possible with
category A and oil temperature less than 60 °C).
788 /rpm
10 s
IDLE-SPEED
780/rpm
ENT
ACCELERATE
STEP BY STEP
SHIFT+ENT
SHIFT+ENT
● Selecting the number of pulses and cylinders
HOLD CUTOFF SPEED
FOR 3 s
ENT or accelerate
SPEED
MAX.
5050 /rpm
------ /rpm
CUTOFF SPEED
5050 /rpm
SHIFT+ENT
ENT
CUTOFF SPEED
OK >
CUTOFF SPEED
NOT OK
>
ENT
To measure the engine speed (RPM), you must select the correct
number of pulses and cylinders to match the engine being tested.
This enables the rotational speed of the engine-speed sensor
connected to be identified. For details, see section 2.4, RPM
measurement (engine-speed measurement).
Before performing RPM measurement (engine-speed
measurement), always connect the B- clamp of the
battery connecting cable (B+/B-) to vehicle earth.
ENT
EGA NOT PASSED
ENT
for measurement
rev-ups
for Result Menu
Use the arrow keys z/v to select the number of pulses or
cylinders
1, 2, 3, 4, 5, 6, 8, 10, 12, 16, 288.
You can freely edit the number of pulses by pressing the # key
After the message “COMPLY WITH TEST CONDITIONS” and
acknowledgement with ENT, you will see a prompt in the display
requiring you to enter the oil temperature.
- Confirm the number of pulses by pressing ENT.
- Enter the oil temperature and confirm it by pressing ENT.
● Measuring the breakaway speed
With category A and oil temperature more than 60 °C it is possible
to skip oil temperature input by pressing ENT.
This measuring step is not obligatory and can be skipped by
pressing ENT.
● Bringing the engine up to normal operating temperature
Starting from idle speed, accelerate the engine carefully up to
breakaway speed.
! If the engine is not brought up to the specified operating
temperature, there is a danger of it being damaged by
carrying out the exhaust-gas analysis test. Apart from that, all
the measured values subsequently gained may possibly be
incorrect.
To check that the engine temperature has reached the specified
value, use the oil-temperature sensor to measure the
oil temperature (prescribed only for category A vehicles).
- Connect the oil-temperature sensor to plug-in socket 5 of the
VSM.
! To avoid damaging the engine, accelerate the engine
slowly up to breakaway speed. If the max. tolerance is
exceeded, abort the procedure immediately!
The breakaway speed is now measured over a period of
3 seconds and a mean value is calculated.
If the breakaway speed is o.k., confirm it by pressing ENT. The
rev-up measurement is then started automatically.
If the breakaway speed is not o.k., confirm this by pressing the
cursor keys z and v , and then press ENT.
The message "EXHAUST-GAS ANALYSIS TEST NOT PASSED"
appears in the display.
13
The prompt “INSERT PROBE” will be displayed before the
measurement rev-ups.
3.4 Rev-up measurement
from engine
conditioning and precheck
Caution! Hot probe!
The exhaust-gas probe may still be very hot from being
used beforehand for testing a different vehicle.
Measurement
rev-ups
Insert the exhaust-gas probe into the exhaust pipe and make sure
that it is seated securely.
Then confirm the prompt by pressing ENT.
INSERT PROBE
ENT
The following information is displayed:
Category A : 3 - 6 rev-ups
Category B : 4 - 10 rev-ups
MEASUREMENT REVUPS TO FOLLOW ....
ENT
"PURGING AND MEASUREMENT REV-UPS WILL FOLLOW".
PLEASE WAIT...
ZERO ADJUSTMENT
Press ENT.
next measurement
IDLE
5s
If necessary, zero adjustment will be carried out.
FULL THROT
Text FULL THROT.
blinks
60s
If triggering over the Russ does not function, press the
ENT key at the same time.
Accelerate / ENT
Yes
FULL THROT.
Acceleration detected, text FULL THROT. does not blink.
After 3 s cutoff speed : text THROT. OFF blinks.
Meas. value is displayed.
THROT. OFF
1.75 m-1
k1..10
After waiting for 5 seconds (Idle), you will receive the prompt
“FULL THROT”.
Push the accelerator pedal to the floor quickly and without
"jolting" and hold it there until the prompt "RELEASE"
appears.
Idle speed
further
rev-up
Evaluation routine decides, whether the further rev-up
is necessary.
After a short evaluation period, the result of the first measurement
appears.
DRIFT ERROR measurement in the purging phase
The evaluation is different for category A vehicles and category B
vehicles.
NO
PLEASE WAIT ...
PURGE
Drift ok ?
( -0.2.....+0.2 )
DRIFT FAULT
DRIFT
0.30 m -1
No
● Category A vehicles
Yes
Evaluation
o.k.
No
At least 3 measurement rev-ups are carried out.
ENT
If all measured values are < 2.00 m-¹, then no further evaluation
is carried out and the measurement is deemed passed.
Yes
EGA
PASSED
EGA
NOT PASSED
ENT
RESULT
PRINT
ENT
Report is
printed out
>
RESULT
<
ENT
Result Menu
SHOW
>
RESULT
<
CURVE
ENT
>
ENT
RESULT
<
QUIT
ENT
CURVE
k1
Result display
ESC
>
ENT
ESC
Back to the main menu
If not all measured values are < 2.00 m-¹, the mean value of the
last 3 measurements is calculated. The lowest turbidity factor of
these 3 measured values must be greater than or equal to 75%
of the mean value.
If the measurement is not valid, another measurement rev-up is
carried out. The new mean value of the last 3 measurements is
then calculated.
Up to a maximum of 6 measurement rev-ups are carried out.
Curve is printed out
If the maximum number of measurement rev-ups is reached, the
following rule applies:
If a turbidity value is < 75% of the mean value, this value is
rejected and the new mean value is calculated from the remaining
measured values. This will be repeated until no turbidity value is
< 75% of the mean value.
If the measurements are within the prescribed tolerance range,
“EGA PASSED” appears on the display. Confirm this by pressing
ENT.
14
● Category B vehicles
If the maximum number of measurement rev-ups is reached, the
following rule applies:
If a turbidity value is < 75% of the mean value, this value is
rejected and the new mean value is calculated from the remaining
measured values. This is repeated until no turbidity value is < 75%
of the mean value.
At least 4 measurement rev-ups are carried out.
If all measured values are < 2.00 m-¹, the mean value of the last
4 measurements is calculated. The lowest turbidity value of these
4 measured values must be greater than or equal to 75% of the
mean value.
If the measurement is not valid, another measurement rev-up is
carried out. The new mean value of the last 4 measurements is
then calculated.
Up to a maximum of 10 measurement rev-ups are carried out.
If the measurements are within the prescribed tolerance range,
“EGA PASSED” appears on the display.
Confirm this by pressing ENT.
The following options are then displayed:
-
Print out measurement result
Display measurement result
Print out curve
End test
3.5 Display measurement results
Result Display
k
AVERAGE VALUE >
1.34 m - 1
>
<
<
>
<
<
k
ENT
MEASURE 1
1.54 m - 1
>
>
<
<
>
<
<
k
ENT
AVERAGE VALUE
IDLE
780 /rpm
>
MEASURE 1 >
IDLE
780 /rpm
ENT
>
<
<
MEASURE 1 >
MAX
5570 /rpm
>
<
<
MEASURE 1 >
Tacc
1.21 s
>
<
<
MEASURE 1 >
Thold
3.03 s
ENT
ENT
MEASURE 2 >
IDLE
780 /rpm
>
<
<
MEASURE 2 >
MAX
5560 /rpm
>
<
<
MEASURE 2 >
Tacc
0.96 s
<
.....
<
k
>
<
<
MEASURE 2 >
Thold
2.76 s
MEASURE N
1.39 m - 1
ENT
.....
<
MEASURE N
MAX
5560 /rpm
.....
<
MEASURE N
Tacc
0.96 s
.....
<
MEASURE N
Thold
2.45 s
ENT
ENT
SHIFT ENT
MEASURE N
IDLE
780 /rpm
ENT
ENT
ENT
AVERAGE VALUE
>Thold
2.45 s
.....
ENT
ENT
AVERAGE VALUE
>Tacc
1.12 s
>
ENT
ENT
AVERAGE VALUE
>MAX
5560 /rpm
MEASURE 2
1.39 m - 1
ENT
SHIFT ENT
SHIFT ENT
SHIFT ENT
ENT
The function is quit at
any place by pressing
the ESC key.
ESC
END
In the menu “Result Display “, the mean values and all
measurements of the following parameters can be displayed:
You can toggle between the average value and the measured
values using the arrow keys z and v.
-
ENT can be used to move from one parameter to the next.
Turbidity value
Idle speed
Cutoff speed
Acceleration time
Hold time
ESC cancels the display of measured results.
15
4. The "Diagnosis" Menu
SELECTION ?
EGA-DIESEL>
SELECTION ?
<DIAGNOSIS>
SELECTION ?
<CONFIGURATION>
SELECTION ?
<TEST FUNCTIONS>
SELECTION ?
< SERVICE >
SELECTION ?
< CALIBRATION
ENT
DIAGNOSIS ?
CONT. MEASURE >
Program sequence depends on
system configuration.
DIAGNOSIS ?
< REV-UPS
ENT
ENT
OILTEMPERATURE
80.0 ° C
ENT
SPEED
788 /rpm
< PULSES 1 ..16 # >
SPEED
788 /rpm
< PULSES 1 ..16 # >
ENT
CUTOFF SPEED
START UP SLOWLY
ENT or
accelerate
ENT
SHIFT+ENT
SPEED
MAX.
Key ESC before meas. block:
Abortion after Main Menu
5050 /rpm
5050 /rpm
automatic connection
if max. value 2 s stable
CUTOFF SPEED
5050 /rpm
ENT
Key ESC after 1 measurement:
Abortion after Result Menu
IDLE
#
4
m -1
0.34
/rpm
870
ENT
5s
FULL THROT.
Accelerate
ENT
No
#
4
°C
120
FULL THROT.
hPa
1020
THROT. OFF
1.75 m-1
k1..16
#
RESULT
PRINT
Meas. value is stored
16 rev-ups ?
Yes
Yes
>
ENT
RESULT
<
CURVE
Text FULL THROT.blinks
Acceleration detected,
Text FULL THROT. not
blinking
after meas. time
Text THROT. OFF blinks
Meas. value is displayed
Throt. off
25 are stored
RESULT
<
SHOW
>
60 s
Remaining time runs
only if idle speed is
available
>
RESULT
<
QUIT
ENT
ENT
back to Main Menu
#
< 4
ENT
ENT
m -1
0.34
KURVE
<
k1 ... Kn
>
Curves SELECTION
only if rev-ups are
available
ENT
#
< 4
°C
120
ESC
16
/min
870 >
hPa
1020 >
ENT
Curve is printed out
No
In the "DIAGNOSIS" menu, you have the choice of two types of
measurement: "CONTINUOUS MEASUREMENT" and "FREE
ACCELERATION".
Use the cursor keys z and v to make your selection and
confirm it by pressing ENT.
4.1 Continuous measurement
Procedure:
- Connect the engine-speed sensor to the vehicle.
- Start the engine and if necessary warm it up.
- Insert the exhaust-gas probe into the exhaust pipe and make
sure it is seated securely.
Caution! Hot probe!
The exhaust-gas probe may still be very hot from being
used beforehand for testing a different vehicle.
You then select the number of pulses and cylinders (proceed
as described in the passage "Selecting the number of pulses
and cylinders" in section 3.3 "Engine preconditioning and
prechecks").
The current engine speed (RPM) is also displayed at the same
time.
After selecting, confirm the inputs by pressing ENT.
You can now carry out up to 25 measurement rev-ups at different
engine speeds (RPM).
Once the engine has reached the desired speed, press the # key
to store the measured value. The measurement is then stopped
by pressing ESC.
Using the cursor keys z and v , you can then display or print out
the measured values or end continuous measurement completely.
Confirm your selection by pressing ENT.
4.2 Free acceleration
This procedure is used to measure the exhaust-gas values, e.g.
when adjusting the engine. The k values are not evaluated and no
purging rev-ups are carried out.
A maximum of 16 measurement rev-ups can be carried out.
If you want to stop carrying out measurement rev-ups before you
reach 10 times, press ESC or ignore the "FULL THROTTLE"
prompt (i.e. do not rev up the engine); the program will then detect
time-out after a specified delay has elapsed.
At the end of the measurements, you can use the cursor keys
z and v to display or print out the measured values, print out
curves which show the opacity and engine-speed values plotted
against time, or end this type of measurement completely.
Confirm your selection by pressing ENT.
17
5. The "Configuration" Menu
5.1 Overview
The "CONFIGURATION" menu allows you to read out information
such as the software version and to enter or change settings such as
the date/time. You have the choice of the following submenu items
(see figure):
-
SW VERSION
LANGUAGE
DATE/TIME
REPORT HEADER
PRINTER
UNITS
Pressing ENT always returns you to the menu.
Important : Only when leaving the configuration by
pressing the ESC key the changes are accepted.
SELECTION ?
EGA-DIESEL >
SELECTION ?
< DIAGNOSIS >
SELECTION ?
<CONFIGURATION>
SELECTION ?
<TEST FUNKTIONS>
SELECTION ?
< SERVICE >
SELECTION ?
< CALIBRATION
ENT
ESC
CONFIGURATION ?
SW-VERSIONS >
CONFIGURATION ?
<
LANGUAGE >
ENT
ENT
VSM ESP
V1.00 15.04.98
ENT
LANGUAGE
GERMAN
< ENGLISH
CONFIGURATION ?
< DATE / TIME >
CONFIGURATION ?
< REPORT HEADING
ENT
VTS NUMBER
XXXXX
>
CONFIGURATION?
< PRINTER
>
CONFIGURATION ?
<
UNITS
ENT
ENT
PRINTER
< INTERN / PDR203 /
PDR212 /
IFACE PC/HOST >
UNIT OPACITY
< % / M-1 >
ENT
ENT
MTM LC R-128
V1g08 18.03.97
REPORT HEADING
7 * 24 CHARACTERS
ENT
RTM
V1a0 12.09.95
ENT
REPORT HEADING
7 * 24 CHARACTERS
ENT
1 LINE
XXXXX
ENT
ENT
ENT
DATE/TIME
SHOW >
ENT
DATE/TIME
11/09/95 18:53
7 LINE
XXXXX
ENT
VEHICLE PRINT ?
< WITHOUT / WITH >
ENT
ENT
DATE/TIME
11/09/95 18:" 53"
ENT
18
ENT
DATE/TIME
"11"/09/95 18:53
....
ENT
ENT
DEALER PRINT ?
< WITHOUT / WITH >
CUSTOMER PRINT ?
< WITHOUT / WITH >
---
DATE/TIME
< SET
SST PC / HOST
1200 BAUD >
< 2400 BAUD >
< 4800 BAUD >
< 9600 BAUD
ENT
ENT
ENT
5.2 Software versions
5.6 Printer
By pressing ENT, you can display three pieces of information
containing a number and date, one after the other:
In the "PRINTER" submenu, you can set the printer type and the
form of the report printout.
VSM Power-supply control module, with national code
PRINTER
INTERNAL or
MTM Motor Test Module (contained in the VSM)
PDR203
PDR212
IFACE PC/HOST
RTM Opacimeter
5.3 Language
In the "LANGUAGE" submenu, you can select the language
you want to work with using the z and v cursor keys and then
confirm your selection by pressing ENT. This setting is stored
permanently, i.e. it is not lost when the Measuring Instrument
is switched off.
Either the installed tape printer or the connected external printer
PDR 203 or PDR 212 will print.
The serial printer interface (SST) can also be configured for
communication with a PC (host).
PRINT DEALER?
YES
or
NO
The 7 x 24 characters described in section 5.5, "Report header",
which contain the test station (dealer’s) address can either be
printed or not.
5.4 Date and time
In the "DATE/TIME" submenu, you can choose between "DISPLAY" and "SET". In the first case, you cannot make any
changes; in the latter, you are switched to Edit mode (see section
2.3.2, "Input or Edit mode") and you can re-enter or change the
date and/or time. The field that can be changed flashes; pressing
ENT moves you to the next field. Pressing ESC either exits the
menu or displays the old setting if changes have been made.
PRINT CUSTOMER?
YES
or
NO
The 6 x 24 characters of customer identification (usually the
name and address) can either be printed in the test report or
not. If you select YES, you can enter this information during the
test procedure, but at no other time.
PRINT VEHICLE?
YES
or
NO
5.5 Report heading
The "REPORT HEADING" submenu contains 7 lines in which
enter the address of the test station.
The vehicle data (registration number, manufacturer, model
etc.) can either be printed in the test report or not. If you select
YES, you can enter this information during the test procedure,
but at no other time.
The details of the test station are then printed out automatically on
the report printouts.
5.7 Units
In the "UNITS" submenu, you can choose between two units of
measurement for the opacity values:
K value in:
Opacity value in:
m-1
%
or
This setting only affects what is displayed in the "TEST
FUNCTION OPACITY" menu.
19
6. The "Test Functions" Menu
6.1 Overview
The "TEST FUNCTIONS" menu enables you to use the system
like a simple measuring unit, i.e. without test procedures. The
following measurements are possible:
-
RPM
OIL TEMPERATURE
BATTERY VOLTAGE
PRINT
Pressing ENT always returns you to the menu.
SELECTION ?
<EGA DIESEL>
SELECTION ?
< DIAGNOSIS >
SELECTION ?
<CONFIGURATION>
SELECTION ?
<TEST FUNKTIONS>
SELECTION ?
< SERVICE >
SELECTION ?
<CALIBRATION>
ENT
Test menu
TEST FUNCTION ?
< RPM >
TEST FUNCTION ?
< OIL TEMPERATURE >
TEST FUNKTION ?
<VOLT-BATTERY>
ENT
TEST FUNCTION ?
< PRINT
ENT
OIL TEMPERATURE
25.1 °C
VOLT-BATTERY
12.4 V
ENT
ENT
ENT
PRINTER
PLEASE WAIT ..
ENT
or after printout
ENT
dependend on the last
setting
ENT
Speed 4000 /rpm
IMPULSE 1 # >
Speed 1000 /min
< IMPULSE 4 # >
ENT
....
ENT
Speed 250 /rpm
< IMPULSE 56.2 #
ENT
#
Speed - - - - /rpm
56_
IMPULSE
ATTENTION:
pressing the key # an input field is opened for additional
impulse numbers (only entry of class1).
With the ESC key back to the Main Menu
6.2 Engine speed (RPM)
6.4 Battery voltage
The engine speed (RPM) is displayed continuously. Using the
cursor keys z and v , you can select the number of pulses of the
engine-speed sensor depending upon the engine to be tested.
The battery voltage is displayed continuously in volts (V).
6.5 Print
6.3 Oil temperature
The temperature is displayed continuously in °C.
20
A test print containing the date, time and all printable characters
is printed.
7. The "Service" Menu
The submenu accessible from the "SERVICE" can only be
reached by entering a code. Only authorised After-Sales Service
staff can access this submenu.
8. The "Calibration" Menu
8.1 Overview
The "CALIBRATION" menu allows you to read information such
as the calibration date and to check and change settings such as
the CRC check. You can choose from the following submenu
items (see also figure entitled "CALIBRATION MENU").
-
CALIBRATION DATE
CALIBRATION MEASUREMENT
CHECK (linearity check)
CRC CHECK
SELECTION ?
EGA-DIESEL >
SELECTION ?
< DIAGNOSIS >
SELECTION ?
<CONFIGURATION>
SELECTION ?
<TEST FUNKTIONS>
SELECTION ?
< SERVICE >
SELECTION ?
< CALIBRATION
ENT
CALIBRATION
< CALIB. DATE >
CALIBRATION
<CALIB. MEASURE>
ENT
CALIB. DATE
SHOW
>
ENT
CALIBRATION
< LINEARITY >
ENT
CALIB. DATE
< SET >
ENT
ENT
PLEASE WAIT ..
ZERO ADJUSTMENT
CALIB. DATE
<
DELETE
CALIBRATION
< CRC-CHECK
ENT
PLEASE WAIT ..
ZERO ADJUSTMENT
CRC-CHECK
_
4 numbers input
ENT
ENT
CALIB. DATE
13.12.98
RTM-FEHLER: 2020
JUSTIERSCHALTER?
CRC-CHECK
7895->$BC $0E27
TEST PIN IN
CALIBRATION SLOT
ENT
ENT
ENT
OK ?
No
No
ROUTINE CHECK
DEFECTIVE
LINEARITY
OK.
FILTER CLEAN ?
ENT
ENT
#0 ARE STORED
N
0,0 %
Save meas. value with the key #
max. 10
#
#1 ARE STORED
N
0,0 %
Unit as in configuration
ESC
RESULT
SHOW
>
RESULT
< PRINT
ENT
Meas. value
printout
ENT
>
RESULT
<
QUIT
ENT
RESULT
<N2
0,0 % >
ENT
21
8.2 Calibration date
9. Error Messages
The "Calibration date" submenu gives the choice between
"DISPLAY", "SET", and "DELETE". In the first case, the last
calibration date is displayed and cannot be changed. The other
two options are only for authorised staff (e.g. the staff of the
calibration agency). In both cases, an error message is
displayed.
If an error arises when switching on during a test procedure or for
some other reason (e.g. calibration is necessary), it is displayed
by means of 2 pieces of information.
RTM error: 2020
Command presently not available. (Adjustment switch?)
The following table lists the individual errors with number, error
text and remedy if it can be performed by the user. In all other
cases, please contact After-Sales Service. This also applies
to error numbers that are not listed in the table.
ENT returns you to the submenu.
The calibration date is stored in the RTM. To calibrate the
system, the calibration seal must be broken and the calibration
switch in the RTM must be pressed. After calibration has been
completed, the calibration switch must be reset and a new seal
attached.
After the RTM opacimeter has been calibrated, the procedure
must be concluded with the menu item "Set calibration date".
- Error number:
- Error text:
4-digit number in the 1st line
normally moving-letter display
2000 Transmitter / receiver
dirty
Clean transmitter and
receiver
2001 Measured value rise is
too small
Clean trasmitter and
receiver
2002 Supply voltage fault
2003 Purging-air curtain error
Check power supply
cables
After-Sales Service
2004 Check required
Inform calibrating agency
2005 EPROM checksum wrong
After-Sales Service
2006 EPROM checksum wrong
After-Sales Service
2009 Too much light on receiver
After-Sales Service
2010 Valve faulty
After-Sales Service
2011 Exhaust-gas temperature
sensor faulty
After-Sales Service
2012 Measuring-chamber
Temperature sensor faulty
After-Sales-Service
2013 D/A converter faulty
After-Sales Service
2020 Command presently not
available
After-Sales Service
2030 Transmission fault
Switch unit off and back on
again
8.3 Calibration measurement
The RTM is balanced (zero-adjusted) etc. and then continuously
displays the opacity in % and m-1.
This measurement is performed with the measuring chamber
closed and without exhaust-gas temperature compensation.
8.4 Check
The RTM is balanced (zero-adjusted) etc. first. The user then sees
the following prompt:
*** Please insert test pen into calibrating plug-in socket.
Confirm by pressing ENT.
If an error is found during the linearity check, the following
message and question to the user are displayed:
*** Routine check fault. Filter been cleaned ?
If the linearity check is run through successfully, OK is displayed.
In both cases, pressing ENT returns you to the "Calibration
check" menu.
8.5 CRC check
This function is solely for use by the staff of the calibration agency
when checking the integrity of the system.
The user reaches an input field in which the cursor is visible. As
soon as the user has entered 4 digits, the associated checksum
appears. ENT returns you to the submenu.
22
10. Maintenance
The measured opacity value must be between 45 % and 55 % or
1.40 m-1 and 1.80 m-1. If a measured value is displayed that is not
within this tolerance, the RTM opacimeter must be serviced inhouse (see Operating Instructions RTM 430 AT-PR UBF 956/1,
Part Number 1 689 979 651).
After servicing, the check using the calibrating pen must be
repeated.
If servicing does not lead to the desired effect, contact your
Bosch After-Sales Service representative.
10.1 Checking display accuracy
- Starting from the Start mask
SELECTION ?
z EGA DIESEL v
- Press the v key 5 times.
The display displays:
10.2 Maintaining the calibrating pen
SELECTION ?
CALIBRATION
Remove any dust deposits on the calibrating pen using a bellowstype lens brush (as used for cleaning camera lens).
! Under NO circumstances use compressed air, because this
would damage the calibrating pen.
- Press ENT.
- Press the v key 2 times.
The display displays:
Calibration
CALIBRATION MEASUREMENT v
- Press ENT.
The display displays:
PLEASE WAIT...
ZERO ADJUSTMENT
After approx. 1 minute, the display displays:
#0
N
STORED
0.0 %
- Insert the calibrating pen into the calibrating plug-in socket of
the receiver end (on the underside of the unit).
H
BOSC
96P
4595
The display displays the following text (example):
OPACITY
50.8x %
1.63x m-1
23
EAM 3.011 - S20
Robert Bosch GmbH
Geschäftsbereich KH
Produktbereich Prüftechnik
Postfach 1129
D 73201 Plochingen
1 689 981 666 KH-PR UBF 957/2 En (08.12.98) Printed in the Federal Republic of Germany - Imprimé en République Fédérale d'Allemagne par Robert Bosch GmbH
Emissions-Analyse-Meßgerät
0 684 103 120