Download Operating Instructions Emissions Analysis Measuring Instrument
Transcript
Operating Instructions Emissions Analysis Measuring Instrument EAM 3.011 - S20 Program description 1 Before starting up and operating the unit, always read through the operating instructions and particularly the safety instructions thoroughly. In this way, you can avoid any uncertainties with respect to use of the unit, thus ensuring your own safety and preventing damage occurring to the unit. All work on the engine, as well as the connection of testers in the engine area and on the ignition system, must be performed only when the engine is not running and the ignition is switched off. Bosch - Test Technology Certified Quality-Management-Systems according to DIN EN ISO 9001 by: Reg. Nr.: 4066-01 Reg. Nr.: Z-1037-17 Licencing agreements By using this program, you agree to be bound by the following terms and conditions: UK MOT approved for vehicles category A and B 1. Copyright: This software and data is the property of Robert Bosch GmbH or her suppliers and is protected with respect to duplication by copyright laws, international agreements and other national legal provisions. No part of this data and software may be duplicated or sold and such action is a punishable offence; should these conditions be contravened, Robert Bosch GmbH shall reserve the right to prosecute and to claim damages. For your nearest UK Service point please contact: 2. Liability: Robert Bosch Ltd P.O.Box 98, Broadwater Park North Orbital Road Denham, Uxbridge Middlesex. UB9 5HJ All data in this program are based as far as possible on manufacturers’ and importers’ specifications. Robert Bosch GmbH shall accept no liability for the accuracy and completeness of this software and data, nor for any damage caused by faulty software and data. In all cases, the extent of liability of Robert Bosch GmbH shall be limited to the actual amount the customer has paid for this product. This disclaimer of liability shall not apply to damage caused willfully or through gross negligence on the part of Robert Bosch GmbH. Tel.: 01895 838 888 Fax: 01895 838 349 (C) Copyright 1994 Robert Bosch GmbH All rights reserved. 2 Contents: Instructions for your personal safety and for the protection of equipment/vehicle components 1. 1.1 1.2 1.3 1.4 1.5 1.6 Page 4 1.7 General Information Application Who it is made for Guarantee Description of the unit Operating the RTM 430 Opacimeter Publication entitled "Connecting Test Systems to the Vehicle" Definitions of terms 2. 2.1 2.2 2.3 2.4 2.5 2.6 2.7 The Basics The display What the keys mean Program control RPM measurement Program and menu overview The sequence charts Overview of the exhaust-gas test 7 7 7 7 8 10 10 10 3. 3.1 3.2 3.3 3.4 3.5 The EGA Diesel (Diesel exhaust-gas analysis test) Vehicle and customer identification Setpoint input and measuring parameters Engine preconditioning and prechecks Rev-up measurement Display measurement results 11 11 12 13 14 15 4. 4.1 4.2 The "Diagnosis" Menu Continuous measurement Free acceleration 16 17 17 5. 5.1 5.2 5.3 5.4 5.5 5.6 5.7 The "Configuration" Menu Overview Software versions Language Date and time Report heading Printer Units 18 18 19 19 19 19 19 19 6. 6.1 6.2 6.3 6.4 6.5 The "Test Functions" Menu Overview Engine speed (RPM) Oil temperature Battery voltage Print 20 20 20 20 20 20 7. The "Service" Menu 21 8. 8.1 8.2 8.3 8.4 8.5 The "Calibration" Menu Overview Calibration date Calibration measurement Check CRC check 21 21 22 22 22 22 9. Error Messages 22 10. Maintenance 10.1 Checking display accuracy 10.2 Maintaining the calibrating pen 6 6 6 6 6 6 6 6 23 23 23 3 Instructions for your personal safety and for the protection of equipment/vehicle components Mains voltages Danger of acid burning in the respiratory system High voltage Hazardous voltages occur in both the lighting system and the electrical system of a motor vehicle. If contact is made with live parts (e.g. with the ignition coil), there is a risk of electric shock from flashover voltages caused by damaged insulation (e.g. ignition cables which have been attacked by martens). This applies to both the primary side and the secondary side of the ignition system, to the cable harness and the plug connections, to the lighting systems (Litronic) and to the tester connections. When exhaust gas measurements are taken, the sampling hoses which are used release a highly caustic gas (hydrogen fluoride) that can cause acid burning in the respiratory system when heated to temperatures in excess of 250 °C (482 °F) or in the event of fire. Safety precautions: - All testers must be connected to properly grounded, shockproof sockets. - Testers must always be connected using the power cables supplied with them. - All extension cables must be fitted with shock-proof contacts. - Any cables with damaged insulation must be replaced (e.g. power or ignition cables). - Connect testers to the lighting system and switch them on before connecting them to the vehicle. - Connect testers to the engine ground or to the battery (B-) before switching on the ignition. - Always switch off the ignition before performing any work on the electrical system of the vehicle. The term "work" includes connecting testers, replacing parts of the ignition system, removing assemblies (e.g. generators), connecting assemblies to a test bench, etc. - Wherever possible, tests and settings should always be carried out with the ignition switched off and the engine stationary. - If tests or settings are carried out with the ignition switched on or the engine running, care must be taken not to touch any live parts. This applies to all the connecting cables of the testers as well as to the connections of any assemblies at the test bench. - Test connections must always be made using suitable connectors (e.g. Set of Test Cables 1 687 011 208 or vehicle-specific adapter cables). - Make sure that all test connections are properly plugged in and secure. - Never open the casing of the screen. - Always wear gloves made of neoprene or PVC when removing combustion residues. Safety precautions: - Consult a doctor immediately after inhaling! - Neutralize any residues left after a fire with a calcium hydroxide solution. This produces non-toxic calcium fluoride, which can be washed away. Danger of acid burning Acids and alkalis can cause severe burning on unprotected skin. Hydrogen fluoride forms hydrofluoric acid in combination with moisture (water). The condensate which accumulates in the sampling hose and in the condensate container likewise contains acid. When replacing the O2 sensor, it should be remembered that it contains alkali. Safety precautions: - Rinse any affected parts of the skin immediately in water, then consult a doctor! - The O2 sensor is a hazardous waste and must be disposed accordingly. Bosch technical equipment suppliers are able to dispose of the sensors O2 in the appropriate manner. If liquid crystal escapes from a damaged liquid crystal display, it is imperative to avoid direct contact between the liquid and the skin, as well as inhalation or swallowing! Safety precautions: - Wash the skin and clothing thoroughly with soap and water if it comes into contact with liquid crystal. - Consult a doctor immediately after inhaling or swallowing liquid crystal. 4 Instructions for your personal safety and for the protection of equipment/vehicle components Danger of asphyxiation Car exhaust fumes contain carbon monoxide (CO) - a colorless, odorless gas. If inhaled, carbon monoxide causes an oxygen deficiency in the body. Extreme caution is therefore essential when working in a pit, as some of the components of the exhaust gas are heavier than air and settle at the bottom of the pit. Caution is also necessary when working on LPG-driven vehicles. Safety precautions: - Always ensure effective ventilation and suction (especially when working in a pit). - Always switch on and connect the suction plant in a closed area. Danger of burning When working on a hot engine, there is a risk of injury from burning if such components as the exhaust gas manifold, the turbocharger, the Lambda sensor, etc. are touched or if parts of the body come too close to them. These components may be heated to temperatures of several hundred degrees Celsius. Depending on the duration of the exhaust gas measurements, the sampling probe of the exhaust gas measuring instrument may also become extremely hot. Safety precautions: - Always wear protective clothing, e.g. gloves. - Allow the engine to cool down first (this also applies to auxiliary heating systems). - Keep the tester connecting cables well away from all hot parts. - Do not leave the engine running any longer than necessary for the test or setting. Danger of injury Noise Danger of crushing If the vehicle is not prevented from rolling away, there is a danger of people being crushed against a workbench, for example. Both running and stationary engines have rotating and moving parts (e.g. belt drives) which may cause injuries to fingers and arms. A special hazard is presented by electrically driven fans, in that they may be switched on without warning while the engine is stationary and the ignition is switched off. There is a danger of tripping over the protruding rollers, the connecting cables and the power cable of the test system. Do not place heavy objects on or lean on the sensor holder, because there is a danger of it breaking and falling on your feet. Noise levels in excess of 70 dB(A) can occur when measurements are carried out on a vehicle, especially at high engine speeds. Damage to hearing may result if human beings are exposed to noise at such levels over an extended period of time. Safety precautions: - If necessary, noise protection facilities must be provided by the owner at all workplaces in the vicinity of the testing area. - If necessary, suitable personal noise protection facilities must be used by the operator. Safety precautions: - Take steps to prevent the vehicle from rolling away while it is being tested. Select the park position if the vehicle has an automatic transmission and apply the handbrake or lock the wheels with chocks (wedges). - Keep well away from rotating/moving parts while the engine is running. - When working on or in the vicinity of electrically driven fans, allow the engine to cool down first, then disconnect the plug of the fan motor. - Keep the tester connecting cables well away from all rotating parts. - Lock the brakes on the test system trolley so that it cannot roll away. - Lay the connecting cables in such a way that no-one can trip over them. - Do not place heavy objects on or lean on the sensor holder. 5 1. General Information 1.7 Definitions of terms 1.1 Application Effective measuring length: - The effective measuring length is the light segment through which the smoke passes. It has a length of 430 mm. The determined measured values are converted as a function of the length of the measuring chamber. The Emissions Analysis Measuring Instrument (EAM) is used for measuring the emissions (of smoke) from diesel-engined vehicles. 1.2 Who it is made for The Emissions Analysis Measuring Instrument has been built for trained, expert personnel in the automotive sector. In order to ensure your own safety and to prevent damage to the equipment as a result of improper use, please read the information in these Operating Instructions carefully. 1.3 Guarantee Never carry out any modifications to our products. Furthermore, KH-PR products must only be used in conjunction with genuine accessories. Non-compliance shall render all terms of the guarantee void. Despite having taken the utmost of care while programming, compiling and checking we cannot guarantee for the accuracy of the operating software (SystemSoft). 1.4 Description of the unit The design, operation and method of connecting the unit to the vehicle can be found in the separate Operating Instructions. Emissions Analysis Measuring Instrument Description of the Unit IA4-UBF 957/1 1 689 981 664 1.5 Operating the RTM 430 Opacimeter A basic description of the RTM 430 opacimeter covering its design, operating instructions, maintenance, technical data and scope of delivery, is contained in the RTM 430 Operating Instructions manual supplied: Opacimeter RTM 430 IA4-UBF 956/1 1 689 979 651 1.6 Publication entitled "Connecting Test Systems to the Vehicle" Useful information concerning the connecting of test systems and their sensors can be found in the following publication: Connecting Test Systems to the Vehicle KH-PR UBF 550/1 En 6 1 689 979 625 Absorption coefficient (k factor) [m-1] - The absorption coefficient is a measure of the amount of light absorbed by the soot, white smoke and blue smoke related to 1 m light segment. Therefore, this coefficient is independent of the used unit. 2. The Basics - Letters keys 2.1 The display A-Z The display consists of a 2-line LCD with 16 characters per line. This means that a number of words must be abbreviated. Long instructions are displayed as moving-letter displays that repeatedly run across the screen. The display is backlit and this function can be switched on and off by means of the key combination SHIFT + I. SHIFT + <Key with yellow lettering> Key combination for entering the special yellow character - Special function keys # For storing measured values (for continuous measurement and checking only). SHIFT + I Key combination for switching the backlighting on and off. 2.2 What the keys mean - The cursor keys are used for selecting options in menus (Standard mode) or for moving the cursor (Edit mode). v z Menu selection or move cursor one character to the right. Menu selection or move cursor one character to the left. Keys for entering letters SHIFT + ENT Key combination for "one step back" 2.3 Program control 2.3.1 The Program or Operation mode - Confirmation key ENT Confirming menu selection or input, or progressing through the test program. - Cancel key ESC For the most part, control of the program consists simply of confirming the test steps specified. This is done using the top keys on the hand-held control unit. If there are several menu items or selection options to choose from, this is indicated by means of selection arrows < and > in the 2nd line. In such cases, the left menu can be selected using the z and v cursor key sand the right menu or another setting option using the or DEL key. Cancel the current program step and return to the main menu. 2.3.2 Input or Edit mode - Delete key DEL Values or texts that can be changed can be changed in Input mode. There are 2 possibilities: Menu selection to the right like v (Standard) or deletes the character to the left of the cursor (Edit mode). - The type of input is identified by the flashing cursor on the left of the input field. Characters can be entered directly. - Shift key SHIFT Switches over to the second level of key assignments (input of the yellow characters). Shift only applies to the next character. ● The content of the field flashes; inputs have already been made - In this case, the entry can be overwritten directly. When the first character is entered, the old entry is deleted completely and the new character you have entered appears together with the cursor. - Space bar SPACE ● The field is empty; no input has been made so far Inserts a blank. - You want to delete, add to or change the old entry. The cursor is not yet visible. - Number keys 0-9 Keys for entering numbers • Decimal point DEL Deletes the entry and the cursor appears on the left. z The cursor appears under the 1st character and this can be overwritten. v The cursor appears after the least character and characters can be added. 7 As soon as the cursor is visible, you are in Input or Edit mode and are able to move the cursor by means of the cursor keys in order to change individual characters. The keys have the following meaning: z v DEL ESC Move cursor one character to the left. Move cursor one character to the right. Deletes the character to the left of the cursor and the remaining characters are shifted to the left. Rejects the changes and displays the old content again as a flashing display. The cursor disappears. 2.4 RPM measurement The engine and ignition must always be switched off before any work is carried out on the ignition system. Before performing RPM measurement (engine-speed measurement), always connect the B- clamp of the battery connecting cable (B+/B-) to vehicle earth. Preparing the measuring point: - The clearance between the clip-on sensor and the next bend in the tubing must be at least 10 mm. - Clean the clamping point in a straight section of the injection tubing using sandpaper. - The metal at the clamping point must be bare and must be totally smooth (no dents etc.). Remove the insulation from around insulated injection tubing. Connecting to the vehicle: - Determine the diameter of the injection tubing and select an appropriate clip-on sensor. The standard clip-on sensor KG6 (6 mm) is enclosed. If the car in question has injection tubes with a different diameter, your can order appropriate clip-on sensors (available as special accessories). - Connect the clip-on sensor to the connecting cable (blade receptacle). i Only ever connect one engine-speed sensor. The system automatically selects the engine-speed sensor connected. - Connect the black clamp of the connecting cable to vehicle earth. Set the number of pulses and cylinders in accordance with the source used for picking up the engine speed (RPM). ! Only use a clip-on sensor that matches the diameter of the injection tubing. 2.4.1 The clip-on sensor ● Measuring point i Clip-on sensors are wearing parts. ! The points listed below must always be observed when handling clip-on sensors, so that damage to the foil in the clipon sensor and therefore failures can be avoided and the service life of the pickup can be extended. A >10 mm B - The clip-on sensor must not be rotated after being clamped with the securing clip. - Only use a clip-on sensor that matches the diameter of the injection tubing. If the diameter of the clip-on sensor is too large, it is not possible to measure the engine speed (RPM). If the diameter of the clip-on is too small, the pickup may be irreparably damaged. - Never use emery paper or other tools to clean the clip-on sensor. Connecting to the Emission Analysis Measuring Instrument: - Connect the clip-on sensor connecting cable to plug-in socket 2 of the Emission Analysis Measuring Instrument (see Description of the unit). - Connect the Emission Analysis Measuring Instrument (plugin socket 1, see Description of the unit) to vehicle earth using clamp B- of the battery connecting cable (B+/B-) in order to achieve equipotential bonding during RPM measurement (engine-speed measurement). 8 459331/1P - The clamping point must be perfectly smooth. If the injection tubing is too thin, clamp the clip to the next metal part available. i The clip-on sensor must not be rotated around the injection tubing after being clamped. The clip-on sensor must be clamped onto the injection tubing in such a way that it does not make contact with any other components (wires, hoses, engine etc.). - Clamp the clip-on sensor onto the cleaned section of injection tubing as shown in the figure. When making the connection, injection tubing level A must flush with the the switching surface (level B) of the clip-on sensor. ● Number of pulses The number of pulses used for RPM measurement (engine-speed measurement) using a clip-on sensor depends upon the type of engine. The number of pulses must be set accordingly: - with a 4-stroke engine, 1 pulse - with a 2-stroke engine, 2 pulses 2.4.4 RPM measurement (engine-speed measurement) by means of alternator residual ripple (battery connecting cable B+/B) The battery connecting cable (B+/B-) is used to measure the engine speed (RPM) of compression-ignition (diesel) engines by means of the vehicle electrical system. ● Functional description 2.4.2 The TDC sensor ● Measuring point If the vehicle manufacturer has installed a TDC sensor in the vehicle or there is a hole provided for fixing the workshop TDC sensor to be used, RPM measurement (engine-speed measurement) can be carried out using this sensor. The engine speed (RPM) is measured by evaluating the residual ripple of the alternator output voltage. This signal is, however, superimposed by interference. To be able to detect the useful signal amongst this interference, an adaptation phase of approx. 15 to 30 seconds is required before the measurement phase. ● Measuring procedure - Connect the vehicle-specific TDC-sensor connecting cable to plug-in socket 3 of the Emission Analysis Measuring Instrument (see Description of the unit) and to the vehicle. ● Number of marks The number of pulses used for RPM measurement (engine-speed measurement) using a TDC sensor depends upon the type of TDC-sensor system. You must know how many pins or notches there per 360° rotation of the crankshaft. - Switch off the engine. - Using the battery connecting cable (B+/B-), connect the VSM (plug-in socket 1, see Description of the unit) to the vehicle battery. The battery connecting cable is protected against polarity reversal. i When working on a 24-V vehicle electrical system, connect to 24V! Do not connect the VSM just to one of the 2 batteries. The voltage range is from 9 to 32 V. When working on a vehicle with a number of independent batteries (e.g. a camping bus), connect the battery connecting cable (B+/B-) to the battery that is charged directly by the vehicle alternator. - Set the number of cylinders accordingly. 2.4.3 The RIV sensor ● Measuring point - Connect the RIV sensor to the injection pump. - Connect the connecting cable of the RIV sensor to plug-in socket 2 of the Emission Analysis Measuring Instrument instead of the clip-on sensor connecting cable (see Description of the unit). - Start the engine and accelerate briefly so that the charge indicator lamp in the vehicle goes out. i Switch on the vehicle lights and if fitted the rear heated window. Switch off the blower and other consumers. - Leave the engine running at idle speed. - The engine speed (RPM) measured can be checked in the "Engine preconditioning and prechecks" test step. ● Number of pulses The number of pulses used for RPM measurement (engine-speed measurement) using an RIV sensor depends upon the type of engine. The number of pulses must be set accordingly: - for 4-stroke engines: pulse number 1 - for 2-stroke engines: pulse number 2 The engine speed (RPM) measured is displayed after approx. 15 to 30 seconds. i If RPM measurement (engine-speed measurement) does not result in a value being displayed, first check whether the polarity of the connections is correct. You can now perform a test rev-up. i The engine must be at normal operating temperature! When performing the test rev-up, watch the breakaway speed. If the breakaway speed displayed is plausible and stable,the engine speed (RPM) measured by means of the alternator’s residual ripple is correct. If not, you must choose a different method of measuring the engine speed (RPM). 9 2.5 Program and menu overview 2.6 The sequence charts When you switch on the Emission Analysis Measuring Instrument (EAM), the software first of all carries out a self-test. Afterwards, the main menu appears containing 6 menu items (selection options) that are selected using the cursor keys z and v and confirmed by pressing the ENT key. The sequence charts illustrated below show you the respective texts displayed on the hand-held control unit in rectangular boxes with two lines of text, single-lined boxes, as they are displayed in uppercase letters on the display. - The keys you need to press to move forwards and backwards in the sequence or to change or make inputs are marked by arrows in the text. EGA Diesel (Diesel exhaust-gas analysis test) Diagnosis Configuration Test functions Service Calibration Lozenges, branching symbols etc. indicate program-internal sequences and decisions as specified either by the user or by statutory regulations. 2.7 Overview of the exhaust-gas test Self test VSM The basic test sequence is shown in the following figure: AUTOM. Download TDM firmware Main Menu AUTOM. SELECTION ? < EGA-DIESEL > RTM and TDM self-tests. In case of malfunction, show cause AUTOM. ENT SELECTION EGA DIESEL DIAGNOSIS CONFIGURATION TEST FUNCTIONS SERVICE CALIBRATION Vehicle Identification DIAGNOSIS EGA DIESEL C O N FIGURATION CONT. MEASURE REV-UPS SW-VERSIONS LANGUAGE DATE/TIME REPORT HEADING PRINTER UNITS TEST FUNCTIONS RPM OIL TEMPERATURE VOLT-BATTERY PRINT Rated value input and measured parameters Key ESC before measuring block : Abortion after Main Menu CODE xxxx SERVICE CALIBRATION CALIB. DATE CALIB. MEASURE LINEARITY CRC-CHECK IFACE PC/HOST IFACE TDM Key ESC after 1 measurement: Abortion after Result Menu IFACE RTM IFACE GAM DISK PRINTER INTERN PRINTER EXTERN DTL-KEYS DTL-DISPLAY SYSTEM_e.VSD Each of these menu items is described in a separate section. Most of the menu items offer a submenu that contains further selection options. Vehicle conditioning, CUTOFF SPEED measurement Measurement rev-ups The test procedures and setting/selection options are described below in detail with the aid of sequence charts. Result Display 10 3. The EGA Diesel (Diesel exhaust-gas analysis test) By pressing SHIFT + ENT, you can return to the previous input field; pressing repeatedly brings you back to the main menu. However, if you change the registration number, the program assumes that you are dealing with a new customer and automatically deletes all previous data. 3.1 Vehicle and customer identification This menu is where you enter data for identifying the vehicle and customer. This data is then printed out together with the test result. Old The report printout contains the data last entered. It is not possible to make any changes. from Main Menu EGA Diesel Vehicle and customer identification IDENTIFICATION? WITHOUT in configuration PRINTER ON/OFF IDENTIFICATION? NEW > > IDENTIFICATION? < OLD ENT VEHICLE IDENTIFICATION Yes VEH. LIC. PLATE ENT new veh. lic. plate? Yes delete old data SHIFT+ENT VEHICLE MAKE _ SHIFT+ENT ENT No VEHICLE MODEL _ SHIFT+ENT ENT VEHICLE TYPE _ SHIFT+ENT ENT ENT MILEAGE _ ENT Customer IDENTIFICATION Yes CUSTOMER 6 * 24 CHARACTERS ENT 1 LINE _ No ENT ----6 LINE _ ENT ENT There are three options for vehicle/customer identification: None The report printout contains no details about the vehicle and customer. New The report printout contains the data that you input during the following procedures. Old customer data is not deleted; it is displayed and can be altered (see section 2.3.2, Input or Edit mode). By pressing ENT, you confirm an input and move on to the next input field. 11 3.2 Setpoint input and measuring parameters 3.2.1 Selecting vehicle category Each exhaust-gas analysis test requires setpoints and measuring parameters. This data must be input into the exhaust-gas measuring system as reference values, so that the measured values can be compared and evaluated. Using the arrow keys z and v, select vehicle category A or category B. This data can be procured either direct from the vehicle manufacturer or importer, or purchased from institutes or publishing houses that compile the data from various vehicle manufacturers. This data can be entered manually into the relevant input fields. 3 to 6 measurement rev-ups are performed for category A vehicles. 4 to 10 measurement rev-ups are performed for category B vehicles. By pressing ENT, you confirm an input and move on to the next input field. 3.2.2 Selecting engine type from vehicle and customer identification In this input field, you must select the engine type “ASPIRATED” or “TURBOCHARGED” using the arrow keys z and v. There are different limit values in the standard at this point for the respective categories. These are used correspondingly to evaluate the EGA. Rated value input and measured parameters By pressing ENT, you confirm the engine type selected and move on to the next input field. 3.2.3 Selecting the probe to be used The emission probe used must be selected with the arrow keys z and v. Probe 1 with a 10mm diameter or probe 2 with a 16mm diameter. VEHICLE ? CATEGORY A > VEHICLE ? < CATEGORY B ENT ENT ENGINE ? ASPIRATED > ENT PROBE ? 1 (10 mm) ENT ENGINE ? < TURBOCHARGED ENT > PROBE ? < 2 (16 mm) ENT for idle speed and cutoff speed measurement 12 By pressing ENT, you confirm the probe type selected and move on to the next input field. - Adjust the immersion depth of the oil-temperature sensor to match that of the oil dipstick (see figure). 3.3 Engine preconditioning and prechecks from rated value input and measured parameters Program sequence depends on system configuration. Engine conditioning Idle speed Cutoff speed measurement COMPLY WITH TEST CONDITIONS. ENT OILTEMPERATURE (60-90) 88.0 °C ENT only possible with category A and oil temperature more than 60 °C ENT REMOVE OILTEMP. PROBE 90 ENT only possible with category A and oil temperature less than 60 °C ENT SPEED 788 /rpm PULSES 1 #> SPEED 788 /rpm < PULSES 2 #> ENT ...... P 94 45 SPEED 788 /rpm < PULSES 25.5 # # ENT SPEED PULSES - - - - /rpm 25.5 ENT is possible if no speed is measured, then triggering in RTM to follow. - Insert the oil-temperature sensor instead of the oil dipstick. Speed > 0 No - The engine-oil temperature is displayed. SHIFT+ENT Yes SPEED RESTZEIT - Remove the oil-temperature sensor (ENT only possible with category A and oil temperature less than 60 °C). 788 /rpm 10 s IDLE-SPEED 780/rpm ENT ACCELERATE STEP BY STEP SHIFT+ENT SHIFT+ENT ● Selecting the number of pulses and cylinders HOLD CUTOFF SPEED FOR 3 s ENT or accelerate SPEED MAX. 5050 /rpm ------ /rpm CUTOFF SPEED 5050 /rpm SHIFT+ENT ENT CUTOFF SPEED OK > CUTOFF SPEED NOT OK > ENT To measure the engine speed (RPM), you must select the correct number of pulses and cylinders to match the engine being tested. This enables the rotational speed of the engine-speed sensor connected to be identified. For details, see section 2.4, RPM measurement (engine-speed measurement). Before performing RPM measurement (engine-speed measurement), always connect the B- clamp of the battery connecting cable (B+/B-) to vehicle earth. ENT EGA NOT PASSED ENT for measurement rev-ups for Result Menu Use the arrow keys z/v to select the number of pulses or cylinders 1, 2, 3, 4, 5, 6, 8, 10, 12, 16, 288. You can freely edit the number of pulses by pressing the # key After the message “COMPLY WITH TEST CONDITIONS” and acknowledgement with ENT, you will see a prompt in the display requiring you to enter the oil temperature. - Confirm the number of pulses by pressing ENT. - Enter the oil temperature and confirm it by pressing ENT. ● Measuring the breakaway speed With category A and oil temperature more than 60 °C it is possible to skip oil temperature input by pressing ENT. This measuring step is not obligatory and can be skipped by pressing ENT. ● Bringing the engine up to normal operating temperature Starting from idle speed, accelerate the engine carefully up to breakaway speed. ! If the engine is not brought up to the specified operating temperature, there is a danger of it being damaged by carrying out the exhaust-gas analysis test. Apart from that, all the measured values subsequently gained may possibly be incorrect. To check that the engine temperature has reached the specified value, use the oil-temperature sensor to measure the oil temperature (prescribed only for category A vehicles). - Connect the oil-temperature sensor to plug-in socket 5 of the VSM. ! To avoid damaging the engine, accelerate the engine slowly up to breakaway speed. If the max. tolerance is exceeded, abort the procedure immediately! The breakaway speed is now measured over a period of 3 seconds and a mean value is calculated. If the breakaway speed is o.k., confirm it by pressing ENT. The rev-up measurement is then started automatically. If the breakaway speed is not o.k., confirm this by pressing the cursor keys z and v , and then press ENT. The message "EXHAUST-GAS ANALYSIS TEST NOT PASSED" appears in the display. 13 The prompt “INSERT PROBE” will be displayed before the measurement rev-ups. 3.4 Rev-up measurement from engine conditioning and precheck Caution! Hot probe! The exhaust-gas probe may still be very hot from being used beforehand for testing a different vehicle. Measurement rev-ups Insert the exhaust-gas probe into the exhaust pipe and make sure that it is seated securely. Then confirm the prompt by pressing ENT. INSERT PROBE ENT The following information is displayed: Category A : 3 - 6 rev-ups Category B : 4 - 10 rev-ups MEASUREMENT REVUPS TO FOLLOW .... ENT "PURGING AND MEASUREMENT REV-UPS WILL FOLLOW". PLEASE WAIT... ZERO ADJUSTMENT Press ENT. next measurement IDLE 5s If necessary, zero adjustment will be carried out. FULL THROT Text FULL THROT. blinks 60s If triggering over the Russ does not function, press the ENT key at the same time. Accelerate / ENT Yes FULL THROT. Acceleration detected, text FULL THROT. does not blink. After 3 s cutoff speed : text THROT. OFF blinks. Meas. value is displayed. THROT. OFF 1.75 m-1 k1..10 After waiting for 5 seconds (Idle), you will receive the prompt “FULL THROT”. Push the accelerator pedal to the floor quickly and without "jolting" and hold it there until the prompt "RELEASE" appears. Idle speed further rev-up Evaluation routine decides, whether the further rev-up is necessary. After a short evaluation period, the result of the first measurement appears. DRIFT ERROR measurement in the purging phase The evaluation is different for category A vehicles and category B vehicles. NO PLEASE WAIT ... PURGE Drift ok ? ( -0.2.....+0.2 ) DRIFT FAULT DRIFT 0.30 m -1 No ● Category A vehicles Yes Evaluation o.k. No At least 3 measurement rev-ups are carried out. ENT If all measured values are < 2.00 m-¹, then no further evaluation is carried out and the measurement is deemed passed. Yes EGA PASSED EGA NOT PASSED ENT RESULT PRINT ENT Report is printed out > RESULT < ENT Result Menu SHOW > RESULT < CURVE ENT > ENT RESULT < QUIT ENT CURVE k1 Result display ESC > ENT ESC Back to the main menu If not all measured values are < 2.00 m-¹, the mean value of the last 3 measurements is calculated. The lowest turbidity factor of these 3 measured values must be greater than or equal to 75% of the mean value. If the measurement is not valid, another measurement rev-up is carried out. The new mean value of the last 3 measurements is then calculated. Up to a maximum of 6 measurement rev-ups are carried out. Curve is printed out If the maximum number of measurement rev-ups is reached, the following rule applies: If a turbidity value is < 75% of the mean value, this value is rejected and the new mean value is calculated from the remaining measured values. This will be repeated until no turbidity value is < 75% of the mean value. If the measurements are within the prescribed tolerance range, “EGA PASSED” appears on the display. Confirm this by pressing ENT. 14 ● Category B vehicles If the maximum number of measurement rev-ups is reached, the following rule applies: If a turbidity value is < 75% of the mean value, this value is rejected and the new mean value is calculated from the remaining measured values. This is repeated until no turbidity value is < 75% of the mean value. At least 4 measurement rev-ups are carried out. If all measured values are < 2.00 m-¹, the mean value of the last 4 measurements is calculated. The lowest turbidity value of these 4 measured values must be greater than or equal to 75% of the mean value. If the measurement is not valid, another measurement rev-up is carried out. The new mean value of the last 4 measurements is then calculated. Up to a maximum of 10 measurement rev-ups are carried out. If the measurements are within the prescribed tolerance range, “EGA PASSED” appears on the display. Confirm this by pressing ENT. The following options are then displayed: - Print out measurement result Display measurement result Print out curve End test 3.5 Display measurement results Result Display k AVERAGE VALUE > 1.34 m - 1 > < < > < < k ENT MEASURE 1 1.54 m - 1 > > < < > < < k ENT AVERAGE VALUE IDLE 780 /rpm > MEASURE 1 > IDLE 780 /rpm ENT > < < MEASURE 1 > MAX 5570 /rpm > < < MEASURE 1 > Tacc 1.21 s > < < MEASURE 1 > Thold 3.03 s ENT ENT MEASURE 2 > IDLE 780 /rpm > < < MEASURE 2 > MAX 5560 /rpm > < < MEASURE 2 > Tacc 0.96 s < ..... < k > < < MEASURE 2 > Thold 2.76 s MEASURE N 1.39 m - 1 ENT ..... < MEASURE N MAX 5560 /rpm ..... < MEASURE N Tacc 0.96 s ..... < MEASURE N Thold 2.45 s ENT ENT SHIFT ENT MEASURE N IDLE 780 /rpm ENT ENT ENT AVERAGE VALUE >Thold 2.45 s ..... ENT ENT AVERAGE VALUE >Tacc 1.12 s > ENT ENT AVERAGE VALUE >MAX 5560 /rpm MEASURE 2 1.39 m - 1 ENT SHIFT ENT SHIFT ENT SHIFT ENT ENT The function is quit at any place by pressing the ESC key. ESC END In the menu “Result Display “, the mean values and all measurements of the following parameters can be displayed: You can toggle between the average value and the measured values using the arrow keys z and v. - ENT can be used to move from one parameter to the next. Turbidity value Idle speed Cutoff speed Acceleration time Hold time ESC cancels the display of measured results. 15 4. The "Diagnosis" Menu SELECTION ? EGA-DIESEL> SELECTION ? <DIAGNOSIS> SELECTION ? <CONFIGURATION> SELECTION ? <TEST FUNCTIONS> SELECTION ? < SERVICE > SELECTION ? < CALIBRATION ENT DIAGNOSIS ? CONT. MEASURE > Program sequence depends on system configuration. DIAGNOSIS ? < REV-UPS ENT ENT OILTEMPERATURE 80.0 ° C ENT SPEED 788 /rpm < PULSES 1 ..16 # > SPEED 788 /rpm < PULSES 1 ..16 # > ENT CUTOFF SPEED START UP SLOWLY ENT or accelerate ENT SHIFT+ENT SPEED MAX. Key ESC before meas. block: Abortion after Main Menu 5050 /rpm 5050 /rpm automatic connection if max. value 2 s stable CUTOFF SPEED 5050 /rpm ENT Key ESC after 1 measurement: Abortion after Result Menu IDLE # 4 m -1 0.34 /rpm 870 ENT 5s FULL THROT. Accelerate ENT No # 4 °C 120 FULL THROT. hPa 1020 THROT. OFF 1.75 m-1 k1..16 # RESULT PRINT Meas. value is stored 16 rev-ups ? Yes Yes > ENT RESULT < CURVE Text FULL THROT.blinks Acceleration detected, Text FULL THROT. not blinking after meas. time Text THROT. OFF blinks Meas. value is displayed Throt. off 25 are stored RESULT < SHOW > 60 s Remaining time runs only if idle speed is available > RESULT < QUIT ENT ENT back to Main Menu # < 4 ENT ENT m -1 0.34 KURVE < k1 ... Kn > Curves SELECTION only if rev-ups are available ENT # < 4 °C 120 ESC 16 /min 870 > hPa 1020 > ENT Curve is printed out No In the "DIAGNOSIS" menu, you have the choice of two types of measurement: "CONTINUOUS MEASUREMENT" and "FREE ACCELERATION". Use the cursor keys z and v to make your selection and confirm it by pressing ENT. 4.1 Continuous measurement Procedure: - Connect the engine-speed sensor to the vehicle. - Start the engine and if necessary warm it up. - Insert the exhaust-gas probe into the exhaust pipe and make sure it is seated securely. Caution! Hot probe! The exhaust-gas probe may still be very hot from being used beforehand for testing a different vehicle. You then select the number of pulses and cylinders (proceed as described in the passage "Selecting the number of pulses and cylinders" in section 3.3 "Engine preconditioning and prechecks"). The current engine speed (RPM) is also displayed at the same time. After selecting, confirm the inputs by pressing ENT. You can now carry out up to 25 measurement rev-ups at different engine speeds (RPM). Once the engine has reached the desired speed, press the # key to store the measured value. The measurement is then stopped by pressing ESC. Using the cursor keys z and v , you can then display or print out the measured values or end continuous measurement completely. Confirm your selection by pressing ENT. 4.2 Free acceleration This procedure is used to measure the exhaust-gas values, e.g. when adjusting the engine. The k values are not evaluated and no purging rev-ups are carried out. A maximum of 16 measurement rev-ups can be carried out. If you want to stop carrying out measurement rev-ups before you reach 10 times, press ESC or ignore the "FULL THROTTLE" prompt (i.e. do not rev up the engine); the program will then detect time-out after a specified delay has elapsed. At the end of the measurements, you can use the cursor keys z and v to display or print out the measured values, print out curves which show the opacity and engine-speed values plotted against time, or end this type of measurement completely. Confirm your selection by pressing ENT. 17 5. The "Configuration" Menu 5.1 Overview The "CONFIGURATION" menu allows you to read out information such as the software version and to enter or change settings such as the date/time. You have the choice of the following submenu items (see figure): - SW VERSION LANGUAGE DATE/TIME REPORT HEADER PRINTER UNITS Pressing ENT always returns you to the menu. Important : Only when leaving the configuration by pressing the ESC key the changes are accepted. SELECTION ? EGA-DIESEL > SELECTION ? < DIAGNOSIS > SELECTION ? <CONFIGURATION> SELECTION ? <TEST FUNKTIONS> SELECTION ? < SERVICE > SELECTION ? < CALIBRATION ENT ESC CONFIGURATION ? SW-VERSIONS > CONFIGURATION ? < LANGUAGE > ENT ENT VSM ESP V1.00 15.04.98 ENT LANGUAGE GERMAN < ENGLISH CONFIGURATION ? < DATE / TIME > CONFIGURATION ? < REPORT HEADING ENT VTS NUMBER XXXXX > CONFIGURATION? < PRINTER > CONFIGURATION ? < UNITS ENT ENT PRINTER < INTERN / PDR203 / PDR212 / IFACE PC/HOST > UNIT OPACITY < % / M-1 > ENT ENT MTM LC R-128 V1g08 18.03.97 REPORT HEADING 7 * 24 CHARACTERS ENT RTM V1a0 12.09.95 ENT REPORT HEADING 7 * 24 CHARACTERS ENT 1 LINE XXXXX ENT ENT ENT DATE/TIME SHOW > ENT DATE/TIME 11/09/95 18:53 7 LINE XXXXX ENT VEHICLE PRINT ? < WITHOUT / WITH > ENT ENT DATE/TIME 11/09/95 18:" 53" ENT 18 ENT DATE/TIME "11"/09/95 18:53 .... ENT ENT DEALER PRINT ? < WITHOUT / WITH > CUSTOMER PRINT ? < WITHOUT / WITH > --- DATE/TIME < SET SST PC / HOST 1200 BAUD > < 2400 BAUD > < 4800 BAUD > < 9600 BAUD ENT ENT ENT 5.2 Software versions 5.6 Printer By pressing ENT, you can display three pieces of information containing a number and date, one after the other: In the "PRINTER" submenu, you can set the printer type and the form of the report printout. VSM Power-supply control module, with national code PRINTER INTERNAL or MTM Motor Test Module (contained in the VSM) PDR203 PDR212 IFACE PC/HOST RTM Opacimeter 5.3 Language In the "LANGUAGE" submenu, you can select the language you want to work with using the z and v cursor keys and then confirm your selection by pressing ENT. This setting is stored permanently, i.e. it is not lost when the Measuring Instrument is switched off. Either the installed tape printer or the connected external printer PDR 203 or PDR 212 will print. The serial printer interface (SST) can also be configured for communication with a PC (host). PRINT DEALER? YES or NO The 7 x 24 characters described in section 5.5, "Report header", which contain the test station (dealer’s) address can either be printed or not. 5.4 Date and time In the "DATE/TIME" submenu, you can choose between "DISPLAY" and "SET". In the first case, you cannot make any changes; in the latter, you are switched to Edit mode (see section 2.3.2, "Input or Edit mode") and you can re-enter or change the date and/or time. The field that can be changed flashes; pressing ENT moves you to the next field. Pressing ESC either exits the menu or displays the old setting if changes have been made. PRINT CUSTOMER? YES or NO The 6 x 24 characters of customer identification (usually the name and address) can either be printed in the test report or not. If you select YES, you can enter this information during the test procedure, but at no other time. PRINT VEHICLE? YES or NO 5.5 Report heading The "REPORT HEADING" submenu contains 7 lines in which enter the address of the test station. The vehicle data (registration number, manufacturer, model etc.) can either be printed in the test report or not. If you select YES, you can enter this information during the test procedure, but at no other time. The details of the test station are then printed out automatically on the report printouts. 5.7 Units In the "UNITS" submenu, you can choose between two units of measurement for the opacity values: K value in: Opacity value in: m-1 % or This setting only affects what is displayed in the "TEST FUNCTION OPACITY" menu. 19 6. The "Test Functions" Menu 6.1 Overview The "TEST FUNCTIONS" menu enables you to use the system like a simple measuring unit, i.e. without test procedures. The following measurements are possible: - RPM OIL TEMPERATURE BATTERY VOLTAGE PRINT Pressing ENT always returns you to the menu. SELECTION ? <EGA DIESEL> SELECTION ? < DIAGNOSIS > SELECTION ? <CONFIGURATION> SELECTION ? <TEST FUNKTIONS> SELECTION ? < SERVICE > SELECTION ? <CALIBRATION> ENT Test menu TEST FUNCTION ? < RPM > TEST FUNCTION ? < OIL TEMPERATURE > TEST FUNKTION ? <VOLT-BATTERY> ENT TEST FUNCTION ? < PRINT ENT OIL TEMPERATURE 25.1 °C VOLT-BATTERY 12.4 V ENT ENT ENT PRINTER PLEASE WAIT .. ENT or after printout ENT dependend on the last setting ENT Speed 4000 /rpm IMPULSE 1 # > Speed 1000 /min < IMPULSE 4 # > ENT .... ENT Speed 250 /rpm < IMPULSE 56.2 # ENT # Speed - - - - /rpm 56_ IMPULSE ATTENTION: pressing the key # an input field is opened for additional impulse numbers (only entry of class1). With the ESC key back to the Main Menu 6.2 Engine speed (RPM) 6.4 Battery voltage The engine speed (RPM) is displayed continuously. Using the cursor keys z and v , you can select the number of pulses of the engine-speed sensor depending upon the engine to be tested. The battery voltage is displayed continuously in volts (V). 6.5 Print 6.3 Oil temperature The temperature is displayed continuously in °C. 20 A test print containing the date, time and all printable characters is printed. 7. The "Service" Menu The submenu accessible from the "SERVICE" can only be reached by entering a code. Only authorised After-Sales Service staff can access this submenu. 8. The "Calibration" Menu 8.1 Overview The "CALIBRATION" menu allows you to read information such as the calibration date and to check and change settings such as the CRC check. You can choose from the following submenu items (see also figure entitled "CALIBRATION MENU"). - CALIBRATION DATE CALIBRATION MEASUREMENT CHECK (linearity check) CRC CHECK SELECTION ? EGA-DIESEL > SELECTION ? < DIAGNOSIS > SELECTION ? <CONFIGURATION> SELECTION ? <TEST FUNKTIONS> SELECTION ? < SERVICE > SELECTION ? < CALIBRATION ENT CALIBRATION < CALIB. DATE > CALIBRATION <CALIB. MEASURE> ENT CALIB. DATE SHOW > ENT CALIBRATION < LINEARITY > ENT CALIB. DATE < SET > ENT ENT PLEASE WAIT .. ZERO ADJUSTMENT CALIB. DATE < DELETE CALIBRATION < CRC-CHECK ENT PLEASE WAIT .. ZERO ADJUSTMENT CRC-CHECK _ 4 numbers input ENT ENT CALIB. DATE 13.12.98 RTM-FEHLER: 2020 JUSTIERSCHALTER? CRC-CHECK 7895->$BC $0E27 TEST PIN IN CALIBRATION SLOT ENT ENT ENT OK ? No No ROUTINE CHECK DEFECTIVE LINEARITY OK. FILTER CLEAN ? ENT ENT #0 ARE STORED N 0,0 % Save meas. value with the key # max. 10 # #1 ARE STORED N 0,0 % Unit as in configuration ESC RESULT SHOW > RESULT < PRINT ENT Meas. value printout ENT > RESULT < QUIT ENT RESULT <N2 0,0 % > ENT 21 8.2 Calibration date 9. Error Messages The "Calibration date" submenu gives the choice between "DISPLAY", "SET", and "DELETE". In the first case, the last calibration date is displayed and cannot be changed. The other two options are only for authorised staff (e.g. the staff of the calibration agency). In both cases, an error message is displayed. If an error arises when switching on during a test procedure or for some other reason (e.g. calibration is necessary), it is displayed by means of 2 pieces of information. RTM error: 2020 Command presently not available. (Adjustment switch?) The following table lists the individual errors with number, error text and remedy if it can be performed by the user. In all other cases, please contact After-Sales Service. This also applies to error numbers that are not listed in the table. ENT returns you to the submenu. The calibration date is stored in the RTM. To calibrate the system, the calibration seal must be broken and the calibration switch in the RTM must be pressed. After calibration has been completed, the calibration switch must be reset and a new seal attached. After the RTM opacimeter has been calibrated, the procedure must be concluded with the menu item "Set calibration date". - Error number: - Error text: 4-digit number in the 1st line normally moving-letter display 2000 Transmitter / receiver dirty Clean transmitter and receiver 2001 Measured value rise is too small Clean trasmitter and receiver 2002 Supply voltage fault 2003 Purging-air curtain error Check power supply cables After-Sales Service 2004 Check required Inform calibrating agency 2005 EPROM checksum wrong After-Sales Service 2006 EPROM checksum wrong After-Sales Service 2009 Too much light on receiver After-Sales Service 2010 Valve faulty After-Sales Service 2011 Exhaust-gas temperature sensor faulty After-Sales Service 2012 Measuring-chamber Temperature sensor faulty After-Sales-Service 2013 D/A converter faulty After-Sales Service 2020 Command presently not available After-Sales Service 2030 Transmission fault Switch unit off and back on again 8.3 Calibration measurement The RTM is balanced (zero-adjusted) etc. and then continuously displays the opacity in % and m-1. This measurement is performed with the measuring chamber closed and without exhaust-gas temperature compensation. 8.4 Check The RTM is balanced (zero-adjusted) etc. first. The user then sees the following prompt: *** Please insert test pen into calibrating plug-in socket. Confirm by pressing ENT. If an error is found during the linearity check, the following message and question to the user are displayed: *** Routine check fault. Filter been cleaned ? If the linearity check is run through successfully, OK is displayed. In both cases, pressing ENT returns you to the "Calibration check" menu. 8.5 CRC check This function is solely for use by the staff of the calibration agency when checking the integrity of the system. The user reaches an input field in which the cursor is visible. As soon as the user has entered 4 digits, the associated checksum appears. ENT returns you to the submenu. 22 10. Maintenance The measured opacity value must be between 45 % and 55 % or 1.40 m-1 and 1.80 m-1. If a measured value is displayed that is not within this tolerance, the RTM opacimeter must be serviced inhouse (see Operating Instructions RTM 430 AT-PR UBF 956/1, Part Number 1 689 979 651). After servicing, the check using the calibrating pen must be repeated. If servicing does not lead to the desired effect, contact your Bosch After-Sales Service representative. 10.1 Checking display accuracy - Starting from the Start mask SELECTION ? z EGA DIESEL v - Press the v key 5 times. The display displays: 10.2 Maintaining the calibrating pen SELECTION ? CALIBRATION Remove any dust deposits on the calibrating pen using a bellowstype lens brush (as used for cleaning camera lens). ! Under NO circumstances use compressed air, because this would damage the calibrating pen. - Press ENT. - Press the v key 2 times. The display displays: Calibration CALIBRATION MEASUREMENT v - Press ENT. The display displays: PLEASE WAIT... ZERO ADJUSTMENT After approx. 1 minute, the display displays: #0 N STORED 0.0 % - Insert the calibrating pen into the calibrating plug-in socket of the receiver end (on the underside of the unit). H BOSC 96P 4595 The display displays the following text (example): OPACITY 50.8x % 1.63x m-1 23 EAM 3.011 - S20 Robert Bosch GmbH Geschäftsbereich KH Produktbereich Prüftechnik Postfach 1129 D 73201 Plochingen 1 689 981 666 KH-PR UBF 957/2 En (08.12.98) Printed in the Federal Republic of Germany - Imprimé en République Fédérale d'Allemagne par Robert Bosch GmbH Emissions-Analyse-Meßgerät 0 684 103 120