Download Installation Manual
Transcript
SMA Solar Technology AG Event no. Message 7508 External fan fault Replace fan Troubleshooting Cause and corrective measures The fan is clogged or defective. The inverter may reduce its power output due to overheating. The inverter continues feeding into the electricity grid. Corrective measures: • Clean the fan 7701 ... 7703 8001 • Replace the fan Self diagnosis Internal device fault. The inverter disconnects from the electricity Interference device grid. Corrective measures: • Contact the SMA Service Line (see Section 15 "Contact" (page 91)). Derating occurred The power supplied by the inverter has been reduced to below nominal power for more than 10 minutes due to overheating. Corrective measures: If this event occurs frequently: • Ensure sufficient ventilation. 8101 ... 8104 Comm. disturbed • Check the heat dissipation (see Section 9.2 "Checking Heat Dissipation" (page 61)). A fault has occurred in the internal communication of the inverter. The inverter continues feeding into the electricity grid. Corrective measures: 8801 ... 8803 No display • Contact the SMA Service Line (see Section 15 "Contact" (page 91)). The display is blank. The inverter continues feeding into the electricity grid. This error can have the following causes: • The ambient temperature is so low that the display disconnects to protect itself. • The inverter cannot identify the display type. • No display is connected or the connection is defective. Corrective measures: • Wait until the temperature has risen above ‒25°C. 9002 Inst. code invalid • Contact the SMA Service Line (see Section 15 "Contact" (page 91)). The SMA Grid Guard code entered (personal installer password) is not valid. Corrective measures: • Enter a valid SMA Grid Guard code. Installation Manual SB25-30TLST-21-IA-en-12 73