Download Installation Manual

Transcript
PowerRouter • Solar battery • Installation manual
4 Installation
EN
CAUTION
Do not connect a single solar panel string to both solar panel string terminals in series (figure 6).
i
The PowerRouter PR30SB models only have one solar panel string input.
i
To prevent static charge we advice to ground the supporting frame of your solar panels. Read the
instructions of the manufacturer.
4.6
Connect the batteries
1.
Install a Battery Disconnect Switch (2-pole isolation) between the PowerRouter and the batteries
(figure 11).
2.
Install a fuse (300 A slow-blow) in series with the positive battery cable. It must be installed on a fixed
surface, as close as possible to the battery (figure 7).
3.
Strip approximately 25 mm of insulation from the cable.
4.
Insert the cable into the terminal of the PowerRouter (red to the positive terminal, black to the
negative terminal).
5.
Tighten the cable connection with a torque between 15 Nm and 20 Nm.
6.
Use cable lug (eyelet terminal) on the other end of the battery cable.
DANGER
Use battery cables with a cross sectional area of 70 mm2 to 95 mm2 and a maximum length of 2.5 m
per cable.
WARNING
Batteries must be located in designated battery charging areas, and must comply with the local
requirements. This is because of the dangers of hydrogen gas and battery acid.
WARNING
Do not smoke or bring open flames near hydrogen gas.
CAUTION
Miswiring can cause damage to the PowerRouter. Read the label on the battery.