Download User Manual
Transcript
User Manual 4.2A-68351-E05 Centro-Matic Injector SL-1 Page 2 of 5 Injector No. 81713, No. 81713A & No. 81770-1 thru 81770-6 Fig. III Completion of the lubricating phase. As piston (4) completes its stroke, it pushes the slide valve piston (6) past the passage, cutting off further admission of lubricant to the passage. The discharge from chamber (a) of the preset amount of lubricant to the outlet is completed; piston and slide valve remain in this position until lubricant pressure in the supply line is vented (relieved) at the pump. Fig. IV Pressure relief. After completion of the lubricating phase, the supply line (lubricant line between pump and injector) must be relieved from pressure. The pressure at injector inlet (P1) must drop below 41 bar. The re-charge with lubricant will be initiated at a pressure of ~ 41 bar, permitting the compressed spring (5) to release. The spring moves the slide valve to closed position. This opens the port from the measuring chamber and permits the lubricant to be transferred from the top of the piston (4) to the discharge chamber (a). After the preset amount of lubricant is shifted from chamber (b) to chamber (a) and the pressure is vented, the injector returns to its normal (rest) position (Fig. I). Note: Injector SL-1 is a so-called ‘direct’ single-line metering device. The injector lubricates under pressure applied by the pump to the injector piston (4). The spring of the injector is only for re-charging purposes. Injector output adjustment: ⇒ See Section 5 ‘Operation’. Technical Data Injector type Part number Output range Output adjustment Operating pressure )4 Series SL-1 81770 - * Injectors with manifold )1 81713 Single unit injector w. thread )2 81713A Replacement injector 0,131-1,31 cm3 Setting by adjusting screw, min. to max. = 8 turns )3 minimum normal maximum 128 bar 173 bar 240 bar Vent pressure < 41 bar Steel, Seals : FKM TMIN TMAX - 26° C + 176° C Constr. materials Amb. temperature (constr. materials) Connections: Manifold 2 connections of 3/8“ NPTF female Injector Outlet: 1/8“ NPTF female Note: )1 Character - * of part number stands for substitution by number of injectors mounted on manifold: - 1, - 2, - 3, - 4, - 5, -6. )2 Single unit injector not illustrated. Injector inlet: 3/8“ NPTF male. )3 Attention: Check output if Adjusting Screw is adjusted to less than ½ turn from minimum. )4 ‘normal’ = recommended operating pressure. During pause time, after completion of the lubrication cycle, a pressure relief below 41 bar must follow. Also note: When used together with injectors type SL-32 & SL33 in a system, the pressure relief must be < 13 bar. Dimensions Assy. Unit Manifold -1 No. 1 2 6 5 8 -2 No. 1 1 9 6 2 -3 No. 1 1 9 6 3 -4 No. 1 1 9 6 4 -5 No. 1 1 9 6 5 -6 No. 2 4 6 9 6 5 * Manifold with 1 mtg. hole Dim. A * * 32 mm 64 mm 95 mm 127 mm Dim. B 64 mm 76 mm 108 mm 140 mm 171 mm 203 mm 4. Erection & Installation CAUTION Warning Never exceed the maximum working pressure of the Centro-Matic system. Do not carry out any assembly or disassembly works when the system is pressurized or pump/machine are in operation. Before using synthetic lubricants, check compatibility with the construction materials of injectors and other system components. Required tools Ring & Open end wrenches of inch-size series are required for the installation of injectors. Mounting of injectors The injectors have two outlets; one outlet must be be closed by the fitting supplied with. The outlet for connecting the feed line has a female thread of 1/8“ NPTF. If the lube point (bearing) to be connected requires more than 1,31 cm3 of lubricant per lube cycle, the outlets of two or more injectors can be externally linked by a connector tube for combined discharge of lubricant; one connector tube is required for each injector connection. The injector manifolds have a female thread of 3/8“ NPTF at both ends. Order connectors separately if required. The manifolds have mounting holes; see figure above. • Injectors can be mounted in any position. Mount injector in a position which permits access for output adjustment and visual function control of the injector. • Location of injectors ⇒ See drawing & instructions of the machine manufacturer. • Allocation of injector/lubricating point ⇒ See drawing & instructions of the machine manufacturer. Subject to change LINCOLN GmbH & Co. KG ∗ Postfach 1263 ∗ D-69183 Walldorf ∗ F a x + ( 4 9 ) 6 2 2 7 3 3 2 5 9 ∗ T e l + ( 4 9 ) 6 2 2 7 3 3 0