Download Operating Instructions Electronic crane scale

Transcript
Regular service:
Every 3 months or
in any case after
12,500 weighings
ƒ
ƒ
ƒ
Check all dimensions, see checklist chapter 10.2
Check shackle or loop for wear, such as for example, plastic
deformation, mechanical damage (unevenness), notches,
grooves, cracks, corrosion, damage to thread and distortions.
Check the fit of the safety latch on the hook, also check it for
defects and make sure that it operates correctly
When weighing using the large construction: check that the
splint and nut on the shackle are not loose
If a dimension should be below the permissible deviation from
the original dimension (see checklist, chapter 10.2) or if there
are other discrepancies, the scale must be repaired immediately
by trained experts (KERN Service). Do not repair it yourself
under any circumstances.
Take the scale out of operation immediately!
ƒ
All repairs and replacement parts must be documented by the
service partner (see list, chapter 11.2).
Every 12 months or
in any case after
50,000 weighings
ƒ
The extended service must be carried out by trained experts
(KERN Service). In this general inspection, all load-carrying
parts must be checked for cracks using magnetic powder
Every 5 years or in
any case after
250,000 weighings
ƒ
All load-carrying parts must be replaced by trained experts
(KERN Service).
ƒ
Replace the crane scale completely
Every 10 years or in
any case after
500,000 weighings
Note
When checking for wear, pay attention to the following descriptions (chapter 10.2).
62
HTS-BA-e-1024